Item 6ACITY OF
S0UTHLA1<,.,E
Department of Planning & Development Services
STAFF REPORT
July 30, 2014
CASE NO: ZA14-057
PROJECT: Site Plan for Lakeside Presbyterian Church Expansion
EXECUTIVE
SUMMARY: On behalf of Lakeside Presbyterian Church, Nationwide Construction is requesting
approval of a Site Plan for Lakeside Presbyterian Church to add an approximately
17,382 square foot expansion to the existing church on property described as Lot 13R,
J. G. Allen No. 18 Addition, an addition to the City of Southlake, Tarrant County, Texas
and located at 2701 W. Southlake Blvd., Southlake, Texas. Current Zoning: "CS"
Community Service District. SPIN Neighborhood # 11.
REQUEST
DETAILS: The applicant is requesting approval of a Site Plan for Lakeside Presbyterian Church to
add an approximately 17,382 square foot two-story expansion to the rear of the
existing church to enlarge the chapel and to create classroom space. Only the first
level of the expansion will be finished out initially.
The Driveway Ordinance requires a deceleration lane to be installed if the right turn
ingress volume exceeds 150 vehicles since the design hour occurs on a Sunday. The
applicant has submitted a letter of obligation agreeing to install the deceleration lane
with the finish out of the second floor of the expansion at some point in the future
(included in Attachment D of this report).
VARIANCE
REQUEST: A variance is requested to the horizontal articulation requirement in Zoning Ordinance
No. 480, Section 43.13.a.4, as amended, to allow the horizontal articulation on the
south side of the building as it is shown on the elevations.
ACTION NEEDED: 1) Conduct a public hearing
2) Consider approval of a Site Plan
ATTACHMENTS: (A) Background Information
(B) Vicinity Map
(C) SPIN Meeting Report dated March 25, 2014
(D) Plans and Support Information — Link to PowerPoint Presentation
(E) Site Plan Review Summary No. 2, dated July 11, 2014
(F) Surrounding Property Owners Map and Responses
(G) Full Size Plans (for Commission and Council Members Only)
STAFF CONTACT: Ken Baker (817)748-8067
Case No.
ZA14-057
Richard Schell (817)748-8602
Case No.
ZA14-057
C�I4►IkIEll
let»1[67e1k1116
1:1:t9] Ell :4Wail QQN**�
PROPERTY
DESCRIPTION
wetkI1X -1zKolel1*101Zvi
CURRENT ZONING:
BACKGROUND INFORMATION
Lakeside Presbyterian Church
Nationwide Construction
%Mill RTWTA RM i1 F HTM y hla
Lot 13R, J. G. Allen No. 18 Addition
111171C•115TS10111171P
"CS" Community Service District
HISTORY: - A Zoning Change and Concept Plan (ZA94-118) from "AG" Agricultural
District to "CS" Community Service District was approved by City Council on
December 6, 1994.
- A Site Plan (ZA05-035) for Lakeside Presbyterian Church was approved by
City Council on June 7, 2005.
- A Plat Showing (ZA05-089) for Lot 13, J. G. Allen No. 18 Addition was filed
December 9, 2005.
- An Amended Plat (ZA08-090) for Lot 13R, J. G. Allen No. 18 Addition was
filed on September 19, 2008.
- A Site Plan to add 28 parking spaces was approved June 19, 2012.
PATHWAYS PLAN: The 2030 Pathways Plan shows an existing 8' multi -use trail along W.
Southlake Blvd.
TREE PRESERVATION: The Tree Preservation Plan shows 78% of the existing canopy to be preserved
and 60% is required to be preserved.
TRANSPORTATION
ASSESSMENT: A Traffic Impact Analysis (TIA) was submitted for the project and a hard copy is
included in the packet. The conclusions from the TIA and the Lee Engineering
review of the TIA are included in Attachment D of this report. The applicant has
provided a letter agreeing to install a deceleration lane on E. Southlake Blvd.
with the finish out of the second floor of the expansion in the future.
CITIZEN INPUT/
BOARD REVIEW: A SPIN meeting for this project was held March 25, 2014. The report from that
meeting is included as Attachment C of this report.
PLANNING AND ZONING
COMMISSION ACTION: July 17, 2014; Approved (6-0) noting the applicant's willingness to provide a
deceleration lane at the time of the second floor finish out prior to a Certificate
of Occupancy being issued with a further note that depending on TxDOT
approval, the deceleration lane may be something that the applicant talks to
the City about further and also noting the applicant has provided to us two
letters dated July 17, 2014 identifying that letter of obligation to construct the
deceleration lane and further noting the applicant's willingness to modify the
longer July 17, 2014 letter to strike the words "need a permit to finish out the
second floor" in the second paragraph and replace those words with "being
Case No. Attachment A
ZA14-057 Page 1
issued a second Certificate of Occupancy" and further noting the motion is
subject to the staff report dated July 11, 2014, further subject to the Site Plan
Review Summary No. 2, dated July 11, 2014 and noting specifically approval of
the variance request in the staff report dated July 11, 2014.
STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated July 11, 2014.
Case No. Attachment A
ZA14-057 Page 2
Vicinity Map
Lakeside Presbyterian Church
N N
128 127 N
N
124 123
N �
120 119 N
w
116 0 115 r U V a
o�0
U
112of 111 0 o o
o WLL
o
W � �
108 >107 ,Zg19
y530
0 2608 2680
104 103 � gLV� 2417
0 o z6zo SOUVI-AK
g651 0 2501 2501C
L
2900 2840 2820 2501 0
A
2419
709 0
zaol
2815
2835
1 2951
0
2621 N wo
a
2910 N
2906 2631
2914
� N O
Oh
29 15
N
3�OQ o
Oh 410
^
o C)
� W
.1p1 705 d 707 711
3110 Z �S 2440 2420
31p0 0
2445 2435
N
W F,
.1
s ZA14-057
Site Plan
0 500 1,000 2,000
Feet
Case No. Attachment B
ZA14-057 Page 1
JUSOUTHLAKE
SPIN MEETING REPORT
CASE NO. Project submittal pending
PROJECT NAME: Lakeside Presbyterian Church
2701 W. Southlake Boulevard
SPIN DISTRICT: SPIN # 11
MEETING DATE: March 25, 2014-1 6:00 PM
MEETING LOCATION: 1400 Main Street, Southlake, TX
City Council Chambers
TOTAL ATTENDANCE: Eighteen (18)
• SPIN REPRESENTATIVE(S) PRESENT: Vic Awtry #7, Monique Schill #11, and Matt
Schire
• APPLICANT(S) PRESENTING: Devon Parsons
• STAFF PRESENT: Patty Moos, Planner I
STAFF CONTACT: Pending
EXECUTIVE SUMMARY
Property Situation
• The property is located at 2701 W. Southlake Boulevard.
Development Details
• Enlarge the church sanctuary from 226 seats to 422 seats
• Build a 2-story 10,447 sf classroom building
• Add additional 68 parking spaces for a total of 167 spaces to an existing c
Site Plan
:hurch.
Case No. Attachment C
ZA14-057 Page 1
View South
View Southwest
View Northeast
Case No. Attachment C
ZA14-057 Page 1
View Northwest
View Southeast
QUESTIONS ICONCERNS
How can someone contact you for questions? Devon Parsons at
DParsons@nationwideconstruction.us
Meeting presentation ended at 6:05 pm
SPIN Meeting Reports are general observations of SPIN Meetings by City staff and SPIN Representatives The report is neither verbatim nor official
meeting minutes, rather it serves to inform elected and appointed officials, City staff, and the public of the issues and questions raised by residents and
the general responses made. Responses as summarized in this report should not be taken as guarantees by the applicant. Interested parties are
strongly encouraged to follow the case through the Planning and Zoning Commission and final action by City Council_
Case No. Attachment C
ZA14-057 Page 1
OVERALL SITE PLAN
Case No. Attachment D
ZA14-057 Page 1
i
I
I
I
i
I
r'
I I
I I
I
I ,
I v I
I I
I ml I
I I
10� I
1 of I
I- I
I of I
I z I II
1
1
I I
I I i II
1 I
1 1 1 I
I 1 I I
1 I 1 I
1 '
1 111
1 '
I '
1 11
I I II
I I 11
I II
I I 11
I I 11
I I II
1 II
I I II
I I II
1 1 II
I I I I
I 1 I I
I 1 11
I I,
I j I I
I
I I II
I I II
I I II
I I
I I II
I II• II
� ill
ENLARGED SITE PLAN
�p��p�'BUFFERY��
I
NOD
II 1
f — im-O" -� r
FIRE LANE
O
1
A
, I
„
i
® I I
I I
II
I I
I I
I
I
II
I
I
I I
I
Ij
I I
I I
I I
9 II
QI I
I
7� I II
I
/ I I
I
Ij
I
/ I I
I
Ij
I I
I I
II
I 1
I
I I
I
11
1 I
I I
II
I I
I I
II
I
I I
I
II
1
I I
I
I I
Case No. Attachment D
ZA14-057 Page 2
TRAFFIC IMPACT ANALYSIS SUMMARY
CONCLUSIONS
The proposed expansion to Lakeside Presbyterian Church is expected to increase entering right -
turn trips before church and exiting right -turn trips after church. With existing conditions, the
level of service before and after church is LOS B for the northbound approach, and LOS A for
the intersection as a whole. This level of service is not expected to change after the proposed
expansion is complete.
This study also considered the necessity of adding more storage length to the site's driveway,
and adding a right -turn deceleration lane to handle the added traffic. According to the City of
Southlake's driveway ordinance, neither of these improvements would be required. In the case
of the right -turn deceleration lane, the Southlake driveway ordinance states that such a lane
may be needed but is not required.
Since the study was based on full build -out and church's unfinished space will not be
immediately utilized, the need for a right -turn deceleration lane can be considered at a later
date. Even with full build -out the right -turn deceleration lane may not be needed since data
was collected in the summer when the church doesn't have Sunday school classes and only has
one church service. During the school year, the inbound trips will be spread out over the
Sunday school and church service times. When the church utilizes the un-finished space a study
may be done based on the actual attendance to determine if a right turn lane is needed at that
point in time.
Case No. Attachment D
ZA14-057 Page 3
LEE ENGINEERING REVIEW OF TRAFFIC IMPACT ANALYSIS
3030 LBJ FREEWAY
j SUITE 1660
DALLAS, TX 75234
972-248-3006
www.LoeEngineering.com
7LEF. Encmvvinc
July 10, 2014
Steven Anderson, P.E.
City of Southlake
1400 Main Street, Suite 320
Southlake, Texas 76092
Re: Lakeside Presbyterian Church Traffic Assessment Study Review
Dear Mr. Anderson:
Per your request, we have reviewed the traffic study for the proposed expansion of Lakeside
Presbyterian Church prepared by Savant Group and dated June 30, 2014.
The proposed development consists of the expansion and construction of an existing Church located
along Southlake Boulevard (FM 1709) east of Watermere.
Our review comments are numbered for ease of reference and the numbering does not imply any
ranking. We have divided our comments into two categories - Informational Comments are those that
require no action by the city or the applicant. Action Comments are those that require a response or
action by the City or applicant. We offer the following comments on the submitted traffic impact
analysis.
INFORMATIONAL COMMENTS (REQUIRE NO ACTION BY CITY OR APPLICANT,)
1. The existing development is 6800 square feet according to the site plan.
2. The existing site driveway is on Southlake Boulevard east of Watermere Boulevard.
3. Based on traffic counts collected as part of this study the existing site generates 62 inbound
movements during the entering peak hour on a Sunday prior to services and 63 exiting
movements during the exiting peak hour after services.
4. According to the study, the existing count volumes were concentrated at a single Sunday
service. During the summer, this church does not operate Sunday school or multiple services
as they do during the school year.
ACTION COMMENTS (REQUIRE RESPONSE OR ACTION BY CITY OR APPLICANT
5. Based on information presented in the study there is a discrepancy in the size of the expansion,
making assessment of the study and site difficult.
o On Page 1 of the study it states that the existing building is 6,811 square feet and the
proposed expansion will add 10,683 square feet to the existing building, bringing the
total size to 24,305 square feet. The total size does not represent the summation of
the existing and expanded land use. The sum total would be 6,811+10,683= 17,494.
Case No. Attachment D
ZA14-057 Page 4
o Page 1 states the total expansion includes 10,459 square feet of unfinished space.
This is roughly equal to the entire expansion.
o The Site Plan appearing in the appendix has two figures depicting the site, one showing
an expansion of 10,409 square feet and one showing an expansion of 9,302 square
feet.
o The size of the proposed expansion is unclear based on the conflicting data presented
in the text and site plans included in the study. Please clarify the size of the expansion.
6. The trip generation data in table 3 and discussed on Page 5 is unclear in the methodology
used to generate the additional traffic anticipated from the expansion. The future traffic
volumes generated by the site do not appear to be generated usingthe existingtrip generation
rate based on counts; nor on the ITE trip generation rates.
o Based on the existing ratio of 62 inbound trips to 6,811 square feet one could expect
approximately 221 inbound trips with 24,305 square feet if a linear relationship is
assumed.
o ITE Trip generation for a 24,305 square foot church would generate a slightly higher
number of inbound trips than the estimate included in the study.
o Please clarify the calculation methodology used to arrive at the future traffic volumes
for the site.
7. The site parking layout shown in the site plan has a stub out in the southwest corner of the
property that appears suitable for serving additional future buildings on the site. If additional
buildings are planned on the site, their sizes and uses should be included in the study.
8. The study states that the need for a right turn deceleration lane can be considered at a later
date once the Church's unfinished space has been fully utilized. The need for the deceleration
lane should be determined now as part of the regular development process unless a
mechanism is developed to allow for the site to be re-evaluated and if required, a turn -lane
constructed by the applicant outside the traditional development process.
o The City of Southlake Driveway ordinance states that a right -turn deceleration lane on
arterials shall be provided if the number of right -turns exceeds 150 during the Sunday
design hour. The ordinance states that if the speed limit is exceeds 40 mph that a
deceleration lane may be required if the Sunday design hour volume exceeds 100
right -turns.
o Based on the projected right -turn traffic volumes included in the study (132), the
number of parking spaces (167), the potential for weekday evening events, and
additional future expansion possibilities on the site, we recommend that the City
pursue the installation of a deceleration lane at this driveway.
If you have any questions, please contact me at (972) 248-3006. We appreciate the opportunity to
provide these services and are available to address any additional comments or concerns.
Sincerely, _
John P. Denholm III, P.E., PTOE
Lee Engineering
TBPE Firm F-450
Case No. Attachment D
ZA14-057 Page 5
LAKESIDE PRESBYTERIAN CHURCH
(Presbyterian Cfturcfi in,4merica
"From Him and Through Him and To Him are all things"
July 18, 2014
City of Southlake Planning and Zoning:
Lakeside Presbyterian Church is petitioning the City of Southlake for a building
permit to expand its sanctuary and add two stories of classrooms to the south
side of Lakeside's building at 2701 West Southlake Blvd. Lakeside intends to
split the construction into two phases. The first phase will expand the sanctuary
and finish out the first floor of classrooms. The second phase will finish the sec-
ond floor of classrooms.
A traffic impact analysis indicated that Lakeside will need a deceleration lane on
Southlake Boulevard once phase two is complete. We have met with Public
Works about when we would need to install the deceleration lane. Public Works
suggested that they believed that Lakeside would not be issued a second Certifi-
cate of Occupancy, which made Public Works inclined to require Lakeside to in-
stall the lane now. PW's concern was that it could not require that of us in the
future since we would not need a permit to complete phase 2.
Lakeside would like to wait until phase 2 to install the deceleration lane and is
requesting a variance from PW's recommendation that we install the lane during
phase 1. To address PW's concern we would like to propose that, upon TxDOT
approval, Lakeside guarantees that it will finish the deceleration lane during
phase 2. If it meets with your approval, Lakeside proposes to execute and pro-
vide to the City of Southlake the attached Letter of Obligation which requires
Lakeside or any other entity that may acquire our property to complete the decel-
eration lane upon the completion of phase 2. We are prepared to execute this
Letter of Obligation upon approval of our variance request by P&Z and the City
Council.
We would be happy to discuss this with you or answer any questions.
Robert J. Mackey Rev. David Boxerman
Building Chairman Senior Pastor
2701 W. Southlake Blvd.
Southlake, TX 76092
www.LakesidePCA.org
817-431-0151
Rev. David Boxerman
Case No. Attachment D
ZA14-057 Page 6
LAKESIDE PRESBYTERIAN CHURCH
Presbyterian Church in America
"From Him and Through Him and To Him are all things"
July 18, 2014
To; City of Southlake
From: Lakeside Presbyterian Church
Subject: Letter of Obligation to construct a deceleration lane
Lakeside Presbyterian Church (LPCA) located at 2701 W. Southlake Blvd. in
Southlake, Texas, guarantees to the City of Southlake that, upon TxDOT approval,
a deceleration lane will be constructed at the aforementioned property, no later
than the completion of the finish out of the second floor of the Sunday School
addition being brought to the Planning and Zoning Board on this the 17th day of
July, 2014. LPCA also guarantees if this property is acquired by another entity,
that this obligation will be part of any sales agreement.
Robert J. Mackey
Building Chairman
Rev. David Boxermanf
Senior Pastor
2701 W. Southlake Blvd.
Southlake, TX 76092
www.LakesidePCA.org
817-431-0151
Rev. David Boxerman
Case No. Attachment D
ZA14-057 Page 7
SITE PLAN REVIEW SUMMARY
Review No.: Three
Project Name: Site Plan — Lakeside Presbyterian Church
APPLICANT: Gina McLean
Nationwide Construction
2151 N. Holland Rd.
Phone: (817) 473-0484
E-mail: gmclean@nationwideconstruction.us
Date of Review: 07/10/14
OWNER: Bob Mackey
Lakeside Presbyterian Church
2701 W. Southlake Blvd.
Southlake, TX 76092
Phone:
E-mail: bobmackey70@verizon.net
CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON
07/09/14 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY
MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY
COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT
RICHARD SCHELL AT (817) 748-8602.
Please make the following changes with regard to easements:
a. Show and label the easements on the Site Plan, Utility Plan and Landscape Plan as they
are shown on the recorded plat.
b. The utility easement for the water line on the plat shows to connect to the property to the
west and not the property to the south. Provide utility easements to match proposed
improvements on the Plat Revision to be processed.
A Plat Revision must be process and recorded with the County to abandon the utility easement
and to dedicate any additional easements that are required prior to issuance of a building permit.
3. The Driveway Ordinance requires a deceleration lane to be installed if the right turn ingress
volume exceeds 150 vehicles if the design hour occurs on a Sunday The applicant has submitted
a letter agreeing to install the deceleration lane with the finish out of the second floor of the
expansion at some point in the future (included in Attachment D of this report).
4. The building is subject to all requirements in Zoning Ordinance No. 480, Section 43.13 Residential
Adjacency Standards. A variance has been requested to allow the horizontal articulation on the
south side of the building as shown on the elevation.
5. Provide fire lanes in compliance with the City Fire Code. Show and label the fire lane width and
any curve radii. Also label any radius of any curbs adjacent to the fire lane. The minimum inside
curve radii allowed for fire lanes is 30 feet.
Tree Conservation/Landscape Review
E-mail: kmartin@ci.southlake.tx.us
Keith Martin
Landscape Administrator
Phone: (817) 748-8229
Case No. Attachment E
ZA14-057 Page 1
II:7Ell N1111156197ki1;.1Ell Wli%IEel kiWe] ►Y,ILY,lEll ki III &I
The Tree Preservation Plan shows 78% of the existing canopy to be preserved and 60% is required to
be preserved.
Please be aware that all existing trees shown to be preserved on the City Council approved Tree
Conservation Plan must be preserved and protected during all phases and construction of the
development. Alteration or removal of any of the existing trees shown to be preserved on the approved
Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved
by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities,
structures grading, and any other structure proposed to be constructed do not conflict with existing
trees intended to be preserved.
LANDSCAPE COMMENTS:
All parking lot landscape islands must contain at least the minimum of one (1) canopy tree with the
remaining area consisting of shrubs, ornamental grasses, ground cover, seasonal color, or a
combination of these plant materials. If a light pole is located within the island it may contain two (2)
accent trees in place of the required canopy tree. Parking lot landscaping does count toward interior
landscape planting requirements.
Indicates informational comment.
# Indicates required items comment.
Fire Department Review
Kelly Clements
Assistant Fire Marshal
Phone: (817) 748-8671
E-mail: klements@ci.southlake.tx.us
CrlEll kIEllMA Wd9]►Yil►YilEll kIII &I
An automatic fire sprinkler system will be required for all commercial structures in excess of 6,000
square feet, with coverage extended into the attic if comprised of combustible construction. (per
2009 I.F.C. Sec. 903.3.1.3 as amended) Also, all exterior building projections over 48 inches that
are comprised of combustible construction must be covered with proper sprinkler protection.
Each building is required to be equipped with an automatic fire alarm system that complies with
the requirements of NFPA 72 and the 2012 International Fire Code with the City of Southlake
amendments. (Alarm requirements will be based on an A-3 occupancy classification)
All air handlers in excess of 2000 cubic feet per minute air movement shall have a duct smoke
detector installed on the return side of the unit. Upon activation of the detector, it shall send an
alarm signal to the fire alarm panel and also shut down the air handler unit. If the units are located
above ceiling tile, remote reset switches must be installed below the duct detector location.
A complete set of plans for the fire sprinkler system and fire alarm system shall be submitted to
Reed Fire Protection for review and approval at 14135 Midway Road in Addison, Texas 75001.
Business phone is 214-638-7599.
FIRE LANE COMMENTS:
Fire apparatus access needs to be an all-weather surface, asphalt or concrete, a minimum of 24
feet wide with 6 inch red striping that contains 4 inch white lettering that states "FIRE LANE NO
Case No. Attachment E
ZA14-057 Page 2
PARKING" every 25 feet, and able to support the imposed loads of fire apparatus. (A minimum of
80,000 pounds GVW)
Provide fire lanes in compliance with the City Fire Code. Show and label the fire lane width and
any curve radii. Also label any radius of any curbs adjacent to the fire lane. The minimum inside
curve radii allowed for fire lanes is 30 feet.
IaIN;a:VillQ 0Ak1111111156191LY,I►YilEll kIII &I
A fire hydrant shall be within 100 feet of the Fire Department Connection.
General Informational Comments
A SPIN meeting was held March 25, 2014.
No review of proposed signs is intended with this site plan. A separate building permit is required
prior to construction of any signs.
All mechanical equipment must be screened of view from right-of-ways and residential properties
in accordance with the Zoning Ordinance No. 480, as amended.
All lighting must comply with the Lighting Ordinance No. 693, as amended.
All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment
Control Ordinance No. 946, as amended.
Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay
Zones.
The applicant should be aware that prior to issuance of a building permit a Plat must be processed
and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan,
and building plans, must be submitted for approval and all required fees must be paid. This may
include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer
Impact and Tap Fees, and related Permit Fees.
Denotes Informational Comment
Case No. Attachment E
ZA14-057 Page 3
z
112 � 111
0_
108 > 107
2920 2900 J 2840 20
?0 3110 100 2817p9
F.M
HLAKE BLVD 2815
2115
3001 2951
3055
3061
2910
3065
2906
^ 2914 ory /
a®
SURROUNDING PROPERTY OWNERS
Lakeside Presbyterian Church
--u-, i-- m- i--- -x
> p ti350 ,5R5
o W 1a
p19
2530 2
2808 2580
� vp 2411
W S THLAKEg�'
2651 2501 2501C
2501 2419
N 2621
2631
O
410
m J
1p� 705 Q 707 711 2390 2360
's 2440 2420
2445 2435 2425
2395 2365
1
Bonola Family Ltd Prtnshp
• •
SF1-A
LandUse
2608 W Southlake Blvd
Acreage•
1.78
•
NR
2
Hall, Jerry
SF1-A
W Southlake Blvd
1.54
F
3
Hall, Jerry
SF1-A
175 Jellico Cir
1.82
F
4
Hall, Jerry G
SF1-A
102 Jellico Cir
1.24
NR
5
Southlake Watermark Holding Lp
SP2
2801 W Southlake Blvd
1.57
NR
6
Wiesman, E I
AG
W Southlake Blvd
13.18
NR
7
Lakeside Presbyteran Church
CS
2701 W Southlake Blvd
7.43
NR
8
Wsb Southlake Owner Vi Lp
SP2
101 Watermere Dr
3.14
NR
9
Southlake Watermark Holding Lp
SP2
201 Watermere Dr
2.95
NR
10
Smyth, Henry C Etux Monica
SP2
300 Watermere Dr
8.90
NR
11
Smyth, Henry C Etux Monica
SP2
300 Watermere Dr
6.37
NR
12
Smyth, Henry C Etux Monica
SP2
300 Watermere Dr
-
NR
13
Crosser, Larry Etux Karen
SP2
302 Watermere Dr
-
F
14
Woodard, Carl D & Ruby K
SP2
304 Watermere Dr
-
NR
15
Herdman, Louise B
SP2
306 Watermere Dr
-
NR
16
Roberts, David Etux Sheryl
SP2
308 Watermere Dr
-
NR
17
Jones, Don L Etux Dorothy H
SP2
310 Watermere Dr
-
NR
18
Twining, John D Etux Lynn
SP2
312 Watermere Dr
-
NR
19
Sisco, William T Etux Mary E
SP2
314 Watermere Dr
-
NR
20
Bonner, Michael E Etux Janet K
SP2
316 Watermere Dr
-
NR
21
Block, Daniel Etux Sharon
SP2
318 Watermere Dr
-
NR
22
Johnston, Richard Etux Matalyn
SP2
320 Watermere Dr
-
NR
23
Wilson, Dwight L Etux Barbara
SP2
322 Watermere Dr
-
NR
24
Feazell, Samuel Etux Pamela
SP2
324 Watermere Dr
-
NR
25
R & P Nevada Trust
SP2
326 Watermere Dr
-
NR
26
Wilson, Helen Z
SP2
328 Watermere Dr
-
NR
Case No. Attachment F
ZA14-057 Page 1
27
Standbridge, Peter T Etux Jean
SP2
330 Watermere Dr
-
NR
28
Rattarree, Lloyd W Jr Etux G G
SP2
332 Watermere Dr
-
NR
29
Holley, Shirley C
SP2
336 Watermere Dr
-
NR
30
Brian, Adrian Etux Florence
SP2
338 Watermere Dr
-
NR
31
Wileman, Walter Etux Mary
SP2
340 Watermere Dr
-
NR
32
Pendley, J Evelyn
SP2
301 Watermere Dr # 101
-
NR
33
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 102
-
NR
34
Forgan, David W Etux Shirley D
SP2
301 Watermere Dr # 103
-
NR
35
Ger/Dar Llc
SP2
301 Watermere Dr # 104
-
NR
36
Coffey, Howard J & Patricia B
SP2
301 Watermere Dr # 105
-
NR
37
Schmidt, R M
SP2
301 Watermere Dr # 106
-
NR
38
Parr, Jay C & Margene
SP2
301 Watermere Dr # 107
-
NR
39
Schultz, Blanche
SP2
301 Watermere Dr # 108
-
NR
40
Fry, Gloria J
SP2
301 Watermere Dr# 109
-
NR
41
Southlake Watermark Holding Lp
SP2
301 Watermere Dr# 201
-
NR
42
Boehme, Jack Etux Verla
SP2
301 Watermere Dr # 202
-
NR
43
Gill, Lucille K Irrev Trust
SP2
301 Watermere Dr # 203
-
NR
44
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 204
-
NR
45
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 205
-
NR
46
Irby, Earline D
SP2
301 Watermere Dr# 206
-
NR
47
Katen, Luella M Trust
SP2
301 Watermere Dr # 207
-
NR
48
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 208
-
NR
49
Miller, Jimmy P Etux Rosamond
SP2
301 Watermere Dr # 209
-
NR
50
Dickson, Sharon E
SP2
301 Watermere Dr # 210
-
NR
51
Goad, Doris J
SP2
301 Watermere Dr # 211
-
NR
52
Southlake Watermark Holdings L
SP2
301 Watermere Dr# 212
-
NR
53
Webb, L G
SP2
301 Watermere Dr # 213
-
NR
54
Frame, Lucile
SP2
301 Watermere Dr # 301
-
NR
55
Hottenstein, Mary Jo
SP2
301 Watermere Dr # 215
-
NR
56
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 216
-
NR
57
Scott, Bernard Est & Virginia
SP2
301 Watermere Dr # 217
-
NR
58
Jacobs, Wanda S
SP2
301 Watermere Dr # 218
-
NR
59
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 219
-
NR
60
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 220
-
NR
61
Robertson, Lula Marie
SP2
301 Watermere Dr# 221
-
NR
62
Mullelly, Virginia M
SP2
301 Watermere Dr # 222
-
NR
63
Flynn, Joan E Tr
SP2
301 Watermere Dr # 301
-
F
64
Schultz, Marilyn L
SP2
301 Watermere Dr# 302
-
NR
65
Southlake Watermark Holding Lp
SP2
301 Watermere Dr# 303
-
NR
66
Miller, Fred J Jr Etux Betty
SP2
301 Watermere Dr # 304
-
NR
67
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 305
-
NR
68
Johnson, Gladys M
SP2
301 Watermere Dr # 306
-
NR
69
Hubbs, Patricia Lee
SP2
301 Watermere Dr# 307
-
NR
70
Elm, Mary Jo
SP2
301 Watermere Dr # 308
-
NR
71
Schmidt, Frederick R Etux M G
SP2
301 Watermere Dr# 309
-
NR
72
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 310
-
NR
73
Draper, Janith D
SP2
301 Watermere Dr # 311
-
NR
74
Smith, Royal D
SP2
301 Watermere Dr # 312
-
NR
75
Hoffman, R A & L A Alexander
SP2
301 Watermere Dr # 313
-
NR
76
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 314
-
NR
77
Kohm, Allan Etux Marcia
SP2
301 Watermere Dr # 315
-
NR
78
Marvel, Mary C
SP2
301 Watermere Dr # 316
NR
79
Thomas, William G
SP2
301 Watermere Dr # 317
-
NR
80
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 318
-
NR
81
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 319
-
NR
Case No. Attachment F
ZA14-057 Page 2
82
Eason, Larry D & Lequita Eason
SP2
301 Watermere Dr # 320
-
NR
83
Mayfield, Scott & Toni Etal
SP2
301 Watermere Dr # 321
-
NR
84
Morris, Peggy Lee
SP2
301 Watermere Dr # 322
-
NR
85
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 401
-
NR
86
Cary, Lois
SP2
301 Watermere Dr # 402
-
NR
87
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 403
-
NR
88
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 404
-
NR
89
Ferney, Stephen J Etux Sandra
SP2
301 Watermere Dr # 405
-
NR
90
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 406
-
NR
91
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 407
-
NR
92
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 408
-
NR
93
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 409
-
NR
94
Smith, Eleanor J
SP2
301 Watermere Dr # 410
-
NR
95
Summers, John P & Wanda J
SP2
301 Watermere Dr # 411
-
NR
96
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 412
-
NR
97
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 413
-
NR
98
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 414
-
NR
99
Edwards, John III Etux Barbara
SP2
301 Watermere Dr # 415
-
NR
100
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 416
-
NR
101
Jeffery, Keith A & Stella Tr
SP2
301 Watermere Dr # 417
-
NR
102
Roxburgh, Greta M
SP2
301 Watermere Dr # 418
-
NR
103
Southlake Watermark Holding Lp
SP2
301 Watermere Dr # 419
-
NR
104
Wells, Richard M Etux Marilyn
SP2
301 Watermere Dr # 420
-
NR
105
Mock 5656 Llc
SP2
301 Watermere Dr # 421
-
NR
106
Keene, Leona C
SP2
301 Watermere Dr # 422
-
NR
107
Southlake Watermark Holding Lp
SP2
301 Watermere Dr
-
NR
108
Golson, Robert B Etux Toni M
SP2
334 Watermere Dr
-
NR
109
Southlake Watermark Holding Lp
SP2
2801 W Southlake Blvd
-
NR
110
Wsb Southlake Owner Vi Lp
SP2
101 Watermere Dr
-
NR
111
Southlake Watermark Holding Lp
SP2
200 Watermere Dr
-
NR
112
Arnold, Edward L Etux Nancy D
SP2
325 Watermere Dr
-
NR
113
Barnes, James R Etux Judy
SP2
327 Watermere Dr
-
NR
114
Murray, Roy L Etux Carol J
SP2
329 Watermere Dr
-
NR
115
Sivas, Patricia A
SP2
331 Watermere Dr
-
NR
116
Baum, Evelyn
SP2
333 Watermere Dr
-
NR
117
Moranville, Ronald Etux Janet
SP2
335 Watermere Dr
-
NR
118
East Village Holdings Llc
SP2
381 Watermere Dr
-
NR
119
Fukunaga, Gen & Cindy F
SP2
383 Watermere Dr
-
NR
120
Phelps Marital Trust
SP2
385 Watermere Dr
-
NR
121
Southlake Watermark Holding Lp
SP2
339 Watermere Dr
-
NR
122
Southlake Watermark Holding Lp
SP2
341 Watermere Dr
-
NR
123
Southlake Watermark Holding Lp
SP2
343 Watermere Dr
-
NR
124
East Village Holdings Llc
SP2
387 Watermere Dr
-
NR
125
East Village Holdings Llc
SP2
389 Watermere Dr
-
NR
126
Vikram Capital Ltd
SP2
2815 W Southlake Blvd
-
NR
127
Southlake Watermark Holding Lp
SP2
201 Watermere Dr
-
NR
128
Southlake Watermark Holding Lp
SP2
501 Watermere Dr
-
NR
129
Southlake Watermark Holding Lp
SP2
151 Watermere Dr
-
NR
Responses: F: In Favor O: Opposed To U: Undecided
NR: No Response
Case No.
ZA14-057
Attachment F
Page 3
Notices Sent:
Responses Received
One hundred twenty-nine (129)
Three (3) — Attached
Case No. Attachment F
ZA14-057 Page 4
Notification Response Form
ZA14-057
meeting Date' July 17, 2014 at 0 30 PM
Hall, Jerry
Po Box 0$2006
l-ort Worth 7x 76182
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING,
Being the owner(s) of the property so noted above, are hereby
in favor of apposed to undecided about
6rcle or underline one)
the proposed Site Plan rererenced above.
Space for comments regarding your position;
r�1i.+t��J� r.y rasa-i���E.�a•.n�-_�.� a�.�
Signature'
Efate: Z �_
Additional Signature: r ..... date:
Printed Narne(s). e-f
Mum $A pmpprty ma-v (s) whase names) are pfirdeh at fDp. Otherwrs� e f rr.# mP Plinninp DcpagmeM. One farm per piuparly.
Phone Number (optional):
Case No. Attachment F
ZA14-057 Page 5
Notification Response Form
ZA14-057
Meeting Date: July 17, 2014 at 6:30 PM
Flynn, Joan E Tr
301 Watermere ❑r Apt 301
Southlake Tx 76092
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING.
Being the owner(s) of the property so noted above; are hereby
in favor of opposed to undecided about
(circle or underline one)
the proposed Site Plan referenced above.
Space for comments regarding your position:
Signature:
Additional Signature:
❑ate_ ' /7
Date:
Printed Name(s): J,- 4,Q i+1
Must be property owner(s) whose narne(s) are prir.ted at top. 4DtfteNvise contact the Pin nning Department. One forth per property.
Phone Number (optional):
Case No. Attachment F
ZA14-057 Page 6
Notification Response Form
ZA14-057
Meeting Date: July 17, 2014 at 6:30 PM
Crosser, Larry Etux Karen
302 Watermere Dr
Southlake Tx 76092
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING.
Being the owner(s) of the property so noted above, are hereby
in favor of , opposed to undecided about
(circle or underline one)
the proposed Site Plan referenced above.
Space for comments regarding your position:
Sign ture: --U Date: _
Additional Signature: Date:
Printed Name(s):
Must be property owner(s) wh
Phone Number (optional):
at top. Otherwise contact the Planning Department. One form per property.
Case No. Attachment F
ZA14-057 Page 7