08202000 International Plumbing Code ORDINANCE NO. 820 AN ORDINANCE ADOPTING THE INTERAMTIONAL PLUMBING CODE, 2000 EDITION; PROVIDING FOR THE ADOPTION OF LOCAL AMENDMENTS THERETO; PROVIDING FOR RECORDING OF SUCH CODE AS A PUBLIC RECORD; PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF ALL ORDINANCES; PROVIDING A SEVER~ABILITY CLAUSE; PROVIDING A SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN PAMPHLET FORM; PROVIDING FOR PUBLICATION IN THE OFFICIAL NEWSPAPER; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, The City of Southlake, Texas is a borne rule city acting under its charter adopted by the electorate pursuant to Article XI, Section 5 of the Texas Constitution and Chapter 9 of the Local Cox eminent Code; and WHEREAS, City Council of the City of Southlake deems it necessary to adopt this ordinance governing requirements for the installation and maintenance of plumbing systems including requirements for materials, in order to protect the health, safety and welfare of the citizens of the City of Southlakc. NOW. THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OFSOUTHLAKE, TEXAS: SECTION I That the International Plumbing Code, 2000 Edition, published by The International Code Councik Inc., is hereby adopted as the Plumbing Code of the Cily of Southlake, except for plumbing systems otherwise regulated under the International Residential Code for One- and Two- Family Dwellings as adopted. A true and correct copy of this Code is attached to this ordinance as Exhibit SECTION 2 That the 2000 International Plumbing Code, as adopted herein, is hereby amended as provided in Exhibit "B" incorporated herein and attached hereto for all purposes of this ordinance. Thc CitI of Southlake may from time to time determine that additional local modifications to the 2(1(10 lnlcmational Plumbing Code are necessaD, and appropriale to meet the unique construction needs of the City of Southlake. To effectuate these modifications, the City council shall enact individual ordinances amending this ordinance fully setting forth the change to be made in the code. Tine amendments shall be consolidated as Exhibit "B" to this ordinance. SECTION 3 Yhe material contained in Exhibits "A" and "B"_to tlnis ordinance shall not be included in the tbrmal municipal codification of ordinances, but shall be maintained as a public record in the office of the City SecretaU, and will be available for public inspection and copsdng during regular business hours. SECTION 4 This ordinance shall be cumulative of all provisions of ordinances of the City of Southlake, Texas, except where the provisions of this ordinance are in direct conflict with the provisions of such ordinances, in '~x hich event thc conflicting provisions of such ordinances are hereby repealed. SECTION 5 It is hereby declared to be the intention of the City Council that the phrases, clauses, sentences, paragraphs and sections of this ordinance are severable, and if any pt~rase, clause, sentence, paragraph or section of this ordinance shall be declared unconstitutional by the valid jud~nnent or decree of any court of competent jurisdiction, such unconstitutionality shall not affect any of the remaining phrases, clauses, sentences, para~aphs and sections of this ordinance, since the same would have been enacted by the City council without lhe incorporation in this ordinance of any such unconstitutional phrase, clause, sentence, paragraph or section, it is not the intention of this ordinance to conl'lict in any way with tlne Plumbing License Law of Texas. SECTION 6 Any person, firm or corporation who violates, disobeys, omits, neglects or refuses to comply with or x~ ho resists the enforcement of any of the provisions of this ordinance shall be fined not more than Two Thousand Dollars (S2~000.00) for all violations involving zoning, fire safety or public health and sanitation, including dmnping or refuse, and shall be fined not more than five hundred dollars ($500) for all other violations of this ordinance. Each day that a violation is permitted to exist shall conslilute a separate ofi'ense. SECTION 7 All rights and remedies of the City of Southlake are expressly saved as to any and all x iolations of the prox isions of any ordinances affecting the installation and maintenance of systems which have accrued at the thne of the effective date of this ordinance; and, as to such accrued x iolations and all pending litigation, both civil and criminal, whether pending in court or not, under such ordinances, same shall not be affected by this ordinance buy may be prosecuted until final disposition by the courts. SECTION 8 The City Secreta~ of the City of Southlake is hereby authorized to publish this ordinance in book or pamphlet fom~ for general distribution among the public, and the operative provisions of this ordinance as so published shall be admissible in evidence in all courts without further proof than the production thereof. SECTION 9 Thc Cit5 SecretaD' of the City of Southlake is hereby directed to publish in the official newspaper of the City of Southlake, the caption, penalty clause, publication clause and effective date 3 ot'this ordinance one time within ten days after passage of this ordinance, as required by Section 3.13 of the Charier of'the City of South ake SECTION 10 This ordinance shall be in Full force and effect from and after its passage and publication as rcquired by lax~. and il is so ordained. ('ITY SECRETARY %~,, '~ ...... T / Passed And Approved On Second Reading On This ~ Day Of ~01. CITY SECRETARY . LEGAL~. ~ ,, APPR~YED AS TO FORM AND ' ~Y" ....... " -'" Oil) Attorney Date: 4 EXHIBIT "B" Amendments to the 2000 International Plumbing Code **Table of Contents, Chapter 7, Section 714; change to read as follows: Section 714 Enqineered C, emput~mzed Drainage Design .............. 60 **Section 102.8; change to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 13 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where the requirements of reference standards or manufacturer's installation instructions do not conform to minimum provisions of this code, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the ICC Electrical Code shall mean the Electrical Code as adopted. **Section 30506.1; change to read as follows: 305.6.1 Sewer depth ~,,i~,~i .......... +~..~+ ...... , ,,. ,..;,,-,+ ......... ,~; ..... ~h~,,~ ..11wv¼'~ ~ '~ ,,,,, ,.,,,.,,, r'~inlr'~, ,m cf rn..,~,k.~r] in.~k~o (r'r~m\ ~,-.i,-.,., ~i,.iok.~,4., ,,~, ,v.~ ~,.~...."""'~'~ at tho ,.v.,,.~"i-+ .... ~ Building sewers shall be a minimum of 12 inches (304 mm) below grade. **Section 310,4; delete. **Sections 312,9,1 and 312.9.2; change to read as follows: 312.9.1 Inspections. Annual inspections shall be made of all backflow prevention assemblies and air gaps to determine whether they are operable. (See Ordinance No. 699, Cross Connection Control Policy.) 312.9.2 Testing. Reduced pressure principle backflow preventer assemblies, double check-valve assemblies, double-detector check valve assemblies and pressure vacuum 5 breaker assemblies shall be tested at the time of installation, immediately after repairs or relocation and at least annually. The testing procedure shall be performed in accordance with applicable local provisions. (See Ordinance No. 699, Cross Connection Control Policy.) In the absence of local provisions, the owner is responsible to ensure that testinq is done in accordance with one of the following standards: (list of standards unchanged} **Section 314.2.1; modify second sentence to read as follows: 314.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Condensate shall discharqe into the sanitary sewer if sewer is available. It shall not dischar§e in a publicly exposed area such as into a street, alley, sidewalk or other areas so as to cause a nuisance. **Section 314.2.2; add a second paragraph to read as foflows: Condensate waste pipes from air-coolinq coils may be sized in accordance with equipment capacity as follows: Equipment Capacity in tons of refriqeration Up to 20 tons Over 20 to 40 tons Over 40 to 90 tons Over 90 to 125 tons Over 125 to 250 tons Minimum Condensate Pipe Inside Diameter 3/4 inch 1 inch 1 1/4 inch 1 ½ inch 2 inch The size of condensate waste pipes may be for one unit or a combination of units, or as recommended by the manufacturer. The capacity of waste pipes assumes a 1~8- inch-per-foot slope, with the pipe running three-quarters full. **Section 314.2.3; add item #4 to read as follows: 4. Discharqe, as noted, shall be to a conspicuous point of disposal to alert occupants in the event of a stoppa.qe of the drain. **Section 401.1; add a sentence to read as follows: The provisions of this Chapter are meant to work in coordination with the provisions of the Buildinq Code. Should any conflicts arise between the two chapters, the Code Official shall determine which provision applies. **Section 403.1; change to read as foflows: 403.1 Minimum number of fixtures. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number as follows: 1. Assembly Occupancies: At least one drinkinq fountain shall be provided at each floor level in an approved location. Exception: A drinkinq fountain need not be provided in a drinkinq or dininq establishment. 2. Groups A, B, F, H, I, M and S Occupancies: Buildinqs or portions thereof where persons are employed shall be provided with at least one water closet for each sex except as provided for in Section 403.2. 3. Group E Occupancies: Shall be provided with fixtures as shown in Table 403.1. 4. Group R Occupancies: Shall be provided with fixtures as shown in Table 403.1. It is recommended, but not required, that the minimum number of fixtures provided also comply with the number shown in Table 403.1. Types of occupancies not shown in Table 403.1 shall be considered individually by the code official. The number of occupants shall be determined by the International Building Code. Occupancy classification shall be determined in accordance with the International Building Code. **Add Section 403.1.2 to read as foflows: 403.1.2 Finish material. Finish materials shall comply with Section 1209 of the/ntemationa/ Buildinq Code. **Section 404.2; change to read as follows: 404.2 Unisex toilet and bathing rooms. In assembly and mercantile occupancies, an accessible unisex toilet room shall be provided where an aggregate of six or more male or female water closets are required provided. In buildings of mixed occupancy, only those water closets... {remainder of section unchanged} .... **Section 405,6; delete. **Section 409.2; change to read as follows: 409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected against backflow by an air gap or backflow preventer in accordance with Section 608. **Section 410.1; change to read as follows: 410.1 Approval. Drinking fountains shall conform to ASME Al12.19.1, ASME Al12.19.2 or ASME Al12.19.9, and water coolers shall conform to ARI 1010. Wherc watcr is se,'¥ed hq Exception: A drinkinq fountain need not be provided in a drinkinq or dininq establishment. **Section 412.4; change to read as follows: location ...... Floor drains 412.4 Required - D,,h~;,-, .... shall be installed in the followinq areas. % In public coin-operated laundries and in the central washing facilities of multiple family dwellings, the rooms containing the automatic clothes washers shall be provided with floor drains located to readily drain the entire floor area. Suc ......... shall have a m;,.; ....... +1,~* ........ +;'~" of "~'+ ~'"" *ha"* 3 ;"'-~'~"- ~7~ ,~,~ ;,. ,4;..~,~,+~,. 2. Commercial kitchens. (In lieu of floor drains in commercial kitchens, the code official may accept floor sinks.) **Section 413.4; change to read as follows: 413.4 Water supply required. All food waste grinders shall be provided with a supply of cold water. The water supply shall be protected aRainst backflow by an air qap or with the installation of a backflow preventer in accordance with Section 608. **Add Section 417.7 to read as follows: 417.7 Test for shower receptors. Shower receptors shall be tested for water tiqhtness by fillinfl with water to the level of the rouflh threshold. The drain shall be pluq,qed in a manner so that both sides of pans shall be subiected to the test at the point where it is clamped to the drain. **Section 419.3; change to read as follows: 419.3 Surrounding material. Wall and floor space to a point 2 feet (610 mm) in front of a urinal lip and 4 feet (1219 mm) above the floor and at least 2 feet (610 mm) to each side of the urinal shall be waterproofed with a smooth, readily cleanable, hard, nonabsorbent material. **Add Section 502.5.1 to read as follows: 8 502.5.1 Electrical requirements. A lighting fixture controlled by a switch located at the required passageway openinq and a receptacle outlet shall be provided at or near the equipment location in accordance with the electrical code. **Add Section 502.7 to read as foflows: 502.7 Water heaters above ground or floor. When the attic, roof, mezzanine or platform on which a water heater is installed is more than eight (8) feet (2438 mm) above the ground or floor level, it shall be made accessible by a stairway or permanent ladder fastened to the buildinq. If the building does not have an equipment room to install a permanent ladder on the wall, or ceilinq space to provide a pull down stairway, then the option to install a readily accessible and identified solenoid type shut off switch shall be used. The switch shall shut off power and gas if applicable as well as the water supply. The switch needs to be under the heater and clearly labeled so that the buildinq occupants can shut it off while waitinq on maintenance personnel. 502.7.1 Whenever the mezzanine or platform is not adequately lighted or access to a receptacle outlet is not obtainable from the main level, li.qhtinq and a receptacle outlet shall be provided in accordance with Section 502.5.1. **Section 504.6. f; change to read as follows: 504.6.1 Discharge. The relief valve shall discharge throuqh full size piping to a safe place of disposal such as the41ee~, outside the building- or an indirect waste receptor. The discharge pipe shall not have any trapped sections and shall have a visible air gap or air gap fitting located in the same room as the water heater. The discharge shall be installed in a manner that does not cause personal injury to occupants in the immediate area or structural damage to the building. The end of the discharqe pipe shall not be threaded. The discharqe pipe shall not discharqe into the pan required in Section 504.7. When discharqinq outside the buildinq, the point of discharge shall be with the end of the pipe not more than two (2) feet (610 mm) nor less than six (6) inches (152 mm) above the qround or the floor level of the area receivinq the discharge and pointinq downward. **Section 505.1; change to read as follows: 505,1 Unfired vessel insulation, Unfired hot water storage tanks shall be insulated so that heat loss is limited as specified in Section 504, International Enerqy Conservation Code. {delete remainder of section} **Add Section 506, 506.1 to read as follows: SECTION 506 COMBUSTION AIR AND VENTILATION 506.1. Combustion air and ventilation. Combustion air and ventilation for fuel burninq water heaters, other than pas-fired, shall be in accordance with the International Mechanical Code. Combustion air and ventilation for pas-fired water heaters shall be in accordance with the International Fuel Gas Code. **Add Section 604.4.1 to read as follows: 604.4.1 State maximum flow rate. Where the State mandated maximum flow rate is more restrictive than those of this section, the State flow rate shall take precedence. **Tables 605.4 and 605.5; delete "Polybutylene (PB) plastic pipe and tubing". **Section 606.1; delete items fl~l, 5 and 6. **Section 606,2; items #1 and 2 change to read as follows: On the fixture supply to each plumbing fixture._ in "*~'"-~.,,v, +~',, ,_,, ..... v,,v and *'""...~ ¢'~';',_,,,,,] .... .~, ,..'~ Exception: Tub and shower valves. 2. On the water supply pipe to each sillcock when subject to freezinp. **Section 607.2.1; change to read as follows: 607.2.1 Piping insulation. Piping in required return circulation systems shall be insulated a~s required in Section 504, International Enerqy Conservation Code. {delete remainder of section) **Section 608.1; change to read as follows: 608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to prevent contamination from nonpotable liquids, solids or gases being introduced into the potable water supply through cross-connections or any other piping connections to the system. Back flow preventer applications shall conform to applicable local requlations, Table 608.1, ex. opt and as specifically stated in Sections 608.2 through LO 608.16.9. **Section 608.17; change to read as follows: 608.17 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with applicable local re~iulations. In the absence of other local re~qulations, installation shall be in accordance with Sections 608.17.1 through 608.17.8. **Section 708.3.4; change to read as follows: 708.3.4 Upper terminal Basc cf stack. Each horizontal drain shall be provided with a cleanout at its upper terminal ,~, ''~ ...... ~ okoU ~ ...... ;,~..,~ .., ~k.. ~. .... ~ -'""~- ..... ~'~ or Exception: Cleanouts may be omitted on a horizontal drain less that five (5) feet (1524 mm) in lenpth unless such line is servinq sinks or urinals. **Add Section 712.5 to read as follows: 712.5 Dual Pump System. All sumps shall be automatically discharqed and, when in any "public use" occupancy where the sump serves more than 10 fixture units, shall be provided with dual pumps or electors arranqed to function independently in case of overload or mechanical failure. For storm drainaqe sumps and pumpin~q systems, see Section 1113, **Section 714, 714.1; change to read as follows: SECTION 714 ENGINEERED ~3M~T~R~Z~D DRAINAGE DESIGN 714.1 Design of drainage system. The sizing requirements for plumbing drainage systems shall be determined by approved ~ design methods. **Section 802.1.1; delete the exception. **Section 802.4; add a sentence to read as follows: No standpipe shall be installed below the ground. **Section 904.1; changed to read as follows: 904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least six (6) inches (152 mm) above the roof, except that where a roof is to be used for any purpose other than weather protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. **Section 912.1; change to read as follows: 912.1 Type of fixture. A combination drain and vent system shall not serve fixtures other than floor drains, standpipes, sinks andqavatecies indirect waste receptors. Combination drain and vent systems shall not receive the discharge of a food waste grinder. **Section 912.2; change to read as follows: 912.2 installation. The only vertical pipe of a combination drain and vent system shall be the connection between the fixture drain of a..,,o~"",,., ....... ~ .., standpipe, and the horizontal combination drain and vent pipe. The maximum vertical distance shall be 8 feet (2438 mm). **Section 1002.10; delete. **Section 1106.1; change to read as follows: 1106.1 General. The size of the vertical conductors and leader, building storm drains, building storm sewers, and any horizontal branches of such drains or sewers shall be based ' ~; .....!!06 ~ ar"~ on six (6) inches per hour the 4 O0 ..... ~' .... ~" rainfall rate ~'-'~""*~"~ ~n, .~., v **Section 1107.3; change to read as follows: 1107.3 Sizing of secondary drains. Secondary (emergency) roof drain system shall be sized in accordance with Section 1106 ~-~o'~'~ '-" ~-~ ~'~;"~'~" .-~+-' ~ ..... ~-;'-~- ~-'- "'~; .... .... fnr'n lo oi~n¢-I in T-~KI~o !4nh '~ 44nn '~ .,,.,~ 4!06 6 b)'*'''' Scuppers shall be sized to prevent the depth of pending water... {remainder of section unchanged.~ .... END OF AMENDMENTS. L2 INVOICE Star-Telegram Customer ID: CTT57 400 W.7th Street Tnv^ice Number: 209002371 FORT WORTH,TX 76102 (817)390-7761 rn.VOi^4.' Date: 12/21/01 Federal Tax ID 22-3148254 Ter!.'F: Net due in 21 days Due Date: 12/31/01 Bill To: POI Number: CITY OF SOUTHLAKE 1400 MAIN ST Order Number: 20900237 STE 440 Soles Rep: 073 SOUTHLAKE, TX 76092-7604 Deserintion: CITY OF SOUTHLA Publication Date: 12/21/01 Lo ititatilntillcation Col Depth Lina—e MU Rate Amount CITY OF SOUTHLAKE,TEXAS 2000 I3580 1 80 LINE $486.40 CITY OF SOUTHLAKE, TEXAS ($421.60) Sales Discount 2000 International Plumbing Code ' ORDINANCE NO. 820 AN• ORDINANCE ADOPTING THE IN- T E R N A T I O N A L 2000 PLUMBINw EDITION_; . 't Amount' $64.80 2000 PROVIDING FOR THE ADOPTION OF LOCAL AMEND- MENTS THERETO; PROVIDING FOR RECORDING OF SUCH CODE AS A PUBLIC RECORD,- D O PROVIDING THAT THIS ORDINANCE �� SHALL BE CUMU- LATIVE OF ALL ORDINANCES; PROVIDING A SEV- ERABILITY CLAUSE; PROVIDING A SAV- INGS CLAUSE; PROVIDING FOR ^ PUBLICATION IN PROVIDING FOFROR . PUBLICATION IN THE ST ATE OF TEX) THE OFFICIAL y Count of Tarrant PROVIDING AN EF-i Y FECTIVE DATE. SECTION 6 Any person, firm or Before me,a Notary raTerdisobeys omits,County and State,this a personally appeared C ity Holland, 3i and Legal Coordinator for the Star-Telegran neglects sly w refuses fog-Telegram, Inc. at F t or , in Tarrant County axas; and v n ,after being duly sworn,did depose and say that resists the enforce-of an advertisement a u ished in the above r e a r or he Ii ted dates: ment of any of the - provisions of this or- dinance shall be fined not more than Two Signed u Thousand Dollars ($2,000.00) for all vi- SUBSCAIBED AND S, olations involvmgE,THIS Wednesday, December 26,s20 zoning, fire safety o� Y public health and , / dumping including' �--�/ • and steal refund NotaryPublic l/�� and shall be fined not more that five hundred dollars ($500) for all r �, _ __ ____ _ other violations of this VICKI L.WASON ordinance. Each day �i that a violation is permitted to exist shall MY COMMISSION EXPIRES constitute a separate PASSED AND AP- or E'' AUGUST 28,2004 Thank You For CIItTE COITC ILTOF �.. SOUTHLAKE, ON THS THE 18th DAY OF DE- MAYORE RIC2K 01 S. ATTEST: SANDRA L. LEGRAND CITY SECRETARY Remit To: Star APPFORMVEE. AS L TO LEN Customer ID: CIT57 TAYLOR JR., CITY P.O. ATTORNEY✓ Customer Name: CITY OF SOUTHLAKE FORT WORTH, TX 76101-2051 Invoice Number: 20900237: Invoice Amount: S64.80 PO Number: Amount Enclosed: ::n I INVOICE Star-Telegram Customer ID: CIT57 400 W.7th Street Invoice Number: 208124621 FORT WORTH,TX 76102 (817)390-7761 Invoice Date: 11/30/01 Federal Tax ID 22-3148254 Terms: Net due in 21 days Due Date: 11/30/01 Bill To: PO Number: CITY OF SOUTHLAKE 1400 MAIN ST Order Number: 20812462 STE 440 Sales Rep: 073 SOUTHLAKE, TX 76092-7604 Description: CITY OF SOUTHLA Publication Date: 11/30/01 .f ::.;::+. ::.:....:.:.......... .......:...... : i . ............................. ::::::::.a:...:.fr:...;.....:>`.. :. of tF ��if : .. :: 9 .: : /. �CITY OF SOUTHLAKE,TEXAS NOTIC 13580 1 57 57 LINE $6.08 $346.56 Sales Discount 1 N81 ems ($300.39) CIven to all Into arsons the it tY I ou oft • outhlhlake,Texas,w II be holding a public hearing durin the regularp city council Net Amount: $46.17 meeting to b18, 2hel001 at 7:00 P.m. The meeting will be held In the City Council Chambers of Town Hall, 1400 Main Street, ppSouthlake, hearinggpwillo beoheld re ardrng the follow- Pluumig.International ORDINANCE NO. AN ORDINANCE ADOPTING THE IN- TERNATIONAL PLUMBING CODE, 2000 EDITION• PROVIDING FT MEN • TUC ADOPTION F THE STATE OF- TB TH RET County of Tarra TPROVIDING THAT SHALL BEDI CUMU- LATIVELL Before me, a No, N A C E SL 3Sid County and State,thi personally appeared ChristyHolland Bid and Legal Coordinator PROVIDING ANEV;- g for the Star-Telel ERABILITY CLA J E; Star-Telegram, Inc. at F rt or , in Tarrant County,Texas; and ho, after being duly sworn,did de ose and sayi PROVIDING A V- PINGS CLAQS ng of an advertisemen w p lisbed in the above n m pa r on the isted dates: PROVIDING F PUBLICATION IN PAMMPHLET FORK pROVIDING FOrn Signed PUUEEBBLIGATION �/I�N� SUBSCRIBED AN NEWSPAPERFIAND ME,THIS Monday, December 03 2001- FECTIV ING AN EF Y: // N76Yik _� andre L. DATE. Sx SecretaeGrand / // cityCity of Southlake, Notary Public Texas .r,.p r O 4•.; VICKI L.WASON MY COMMISSION EXPIRES '"F----ietf AUGUST 28,2004 Thank You For Your Payment Remit To: Star-Telegram Customer ID: CIT57 P.O. Box 901051 Customer Name: CITY OF SOUTHLAKE FORT WORTH, TX 76101-2051 Invoice Number: 208124621 Invoice Amount: $46.17 PO Number: Amount Enclosed: $ I