0695ORDINANCE N0.695
AN ORDINANCE ADOPTING THE INTERNATIONAL PLUMBING CODE, 1997
EDITION; PROVIDING FOR THE ADOPTION OF LOCAL AMENDMENTS
THERETO; PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF
ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING A
SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN PAMPHLET FORM;
PROVIDING FOR PUBLICATION IN THE OFFICIAL NEWSPAPER; AND
PROVIDING AN EFFECTIVE DATE.
WHEREAS, The City of Southlake, Texas is a home rule city
acting under its charter adopted by the electorate pursuant to
Article XI, Section 5 of the Texas Constitution and Chapter 9 of
the Local Government Code; and
WHEREAS, City Council of the City of Southtake deems it
necessary to adopt this ordinance governing requirements for the
installation and maintenance of any plumbing and gas piping systems
including requirements for materials, in order to protect the
health, safety and welfare of the citizens of the City of
Southlake.
NOW, THEREFORE,
OF SOUTHLAKE, TEXAS:
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY
SECTION 1
That the International Plumbing Code, 1997 Edition, published
by %he international Code Council, Inc., is hereby adopted as the
Plumbing Code of the City of Southlake. A true and correct copy of
this Code is attached to this ordinance as Exhibit "A."
SECTION 2
That the 1997 International Plumbing Code, as adopted herein,
is hereby amended as provided in Exhibit "B" incorporated herein
and attached hereto for all purposes of this ordinance. The City of
Southlake may from time to time determine that additional local
modifications to the 1997 International Plumbing Code are necessary
and appropriate to meet the unique construction needs of the City
of Southlake. To effectuate these modifications, the City council
shall enact individual ordinances amending this ordinance fully
setting forth the change to be made in the code. The amendments
shall be consolidated as Exhibit "B" to this ordinance.
SECTION 3
The material contained in Exhibit "A" to this ordinance shall
be maintained as a public record in the office of the City
Secretary. These exhibits will be available for public inspection
and copying during regular business hours.
SECTION 4
This ordinance shall be cumulative of all provisions of
ordinances of the City of Southlake, Texas, except where the
provisions 0f this ordinance are in direct conflict with the
provisions of such ordinances, in which event the conflicting
provisions of such ordinances are hereby repealed.
2
SECTION 5
It is hereby declared to be the intention of the City Council
that the phrases, clauses, sentences, paragraphs and sections of
this ordinance are severable, and if any phrase, clause, sentence,
paragraph or section of this ordinance shall be declared
unconstitutional by the valid judgment or decree of any court of
competent jurisdiction, such unconstitutionality shall not affect
any of the remaining phrases, clauses, sentences, paragraphs and
sections of this ordinance,
by the City council without
any such unconstitutional
section.
since the same would have been enacted
the incorporation in this ordinance of
phrase, clause, sentence, paragraph or
SECTION 6
Any person, firm or corporation who violates, disobeys, omits,
neglects or refuses to comply with or who resists the enforcement
of any of the provisions of this ordinance shall be fined not more
than Two Thousand Dollars ($2,000.00) for each offense.
that a violation is permitted to exist shall constitute
offense.
SECTION 7
Each day
a separate
Ail rights and remedies of the City of Southlake are expressly
saved as to any and all violations of the provisions of any
3
ordinances affecting the installation and maintenance of plumbing
and gas systems which have accrued at the time of the effective
date of this ordinance; and, as to such accrued violations and all
pending litigation, both civil and criminal, whether pending in
court or not, under such ordinances, same shall not be affected by
this ordinance buy may be prosecuted until final disposition by the
courts·
SECTION 8
The City Secretary of the City of Southlake is hereby
authorized to publish this ordinance in book or pamphlet form for
general distribution among the public, and the operative provisions
of this ordinance as so published shall be admissible in evidence
in all courts without further proof than the production thereof.
SECTION 9
The City Secretary of the City of Southlake is hereby directed
to publish the proposed ordinance or its caption and penalty
together with a notice setting out the time and place for a public
hearing thereon at least ten (10) days before the second reading of
this ordnance, and if this ordinance provides for the imposition of
any penalty, fine or forfeiture for any violation of any of its
provisions, then the City Secretary shall additionally publish this
4
ordinance in the official City newspaper one time within ten days
after passage of this ordinance, as required by Section 3.13 of the
Charter of the City of Southlake.
SECTION 10
This ordinance shall be in full force and effect from and
after its passage and publication as required by law, and it is so
ordained.
OF
PASSED AND APPROVED ON FIRST READING ON TI{IS
7 DAY
MAYOR
CITY SECRETARY
AND APPROVED ON SECOND READING ON TI{IS
· 1998.
\\\~BIlIIIIIIIi;I
~ ~.... ..... ?%.
MAYOR
DAY OF
CITY SECRETARY
5
APPROVED AS TO FORM AND LEGALITY:
C~y At ~orney ,/
C:~WPDOCS~ORDIANC.plb
EXHIBIT ~B"
Amendments to the
1997 International Plumbing Code
**Table of Contents, Chapter 7, Section 714; changed to read as follows:
Section 714 Engineered,~,~,,n~,~L~,,,~,-,~'-' ....... -'--~ Drainage Design .................... 59
**Chapter 1, Administration: add introductory note to read as follows:
Note: The administrative vrovisions of the Administrative Code as adopted by this jurisdiction shall
take precedence over this chapter.
**Section 202; the definition of "Code Official" is changed and new definitions are added to read as
follows:
BUILDING CODE. Buildine Code shall mean the Building Code as adopted by this iurisdiction.
('ODE OFFICIAL. The officer or other designated authority charged with the administration and
enforcement of this code, or a duly authorized representative. For the purpose of this code. the Code
Official shall be the Building Official.
ELECTRICAL CODE. Electrical Code shall mean the National Electrical Code as adopted bv this
jurisdiction. For the purpose of this code, all references to NFPA 70 shall be assumed to mean the
97 IPC 6 of 1 11/20/97
6
Electrical Code as defined herein.
FIRE PREVENTION CODE (FIRE CODE}. Fire Prevention Code shall mean the Fire Code as adorned
by this iufisdiction.
MECHANICAL CODE. Mechanical Code shall mean the International Mechanical CodeTM as adopted
by this Jurisdiction.
PLUMBING CODE. Plumbine'Code shall mean this code as adopted bv this jurisdictigp.
**Section 305.6.1; changed to read as follows:
305.6.1 Sewer depth. Ir~..:l~ll .......... 1. ............ ~2 .............
shall be a minimum of 12 inches 004 mm) below grade.
**Section 305. 9; changed to read as follows:
305.9 Protection of components of plumbing system. Components of a plumbing system installed
within 3 feet along alleyways, driveways, parking garages or other locations in a manner in which they
would be exposed to damage shall be recessed into the wall or other~vise protected in an approved manner.
**Section 310. 4; delete.
**Section 312. 9; changed to read as follows:
312.9 Inspection and testing of backflow prevention assemblies. Inspections shall be made of all
backflow prevention assemblies to determine whether they are operable.
Reduced pressure principle backtl0w preventer assemblies, double check-valve assemblies, double-
detector check-valve assemblies and pressure vacuum breaker assemblies shall be tested. Testin~ shall be
done in accordance with applicable local provisions.
11/20/97
97 IPC 7 of 1
7
**Section 401.4; added to read as follows:
401.4 Conflict with other codes. Chapter 4 is intended to provide enforceable euidelines for the plumbiiat,
desiener/installer. Should there be any conflict between this Chapter and the Building Code. the Building
Code shall take precedence.
**Section 403.1; changed to read as follows:
403.1 Minimum number of f'Lxtures. Plumbing fixtures shall be provided for the type of occupancy and
in the minimum number as required by Chapter 29 of the Buildine CQde. As a recommended but not
required alternate to the minimum number of plumbing, fixturessee o,,,~L .... ,, in Table 403.1 of this code or
Al~r~endix Char)ter 29 of the Building Code ~r ...... c ......... : ...... ~. ....:_ -r.~L.i- Atto 1 _1._1,
**Sections 403.2; 403.4; 403.5; and 403.6; delete.
**Section 404.3.1.2; add a second paragraph to read as follows:
Flush controls shall be hand operated or automatic. Hand ooerated controls for flushometers shall be
mounted 44 in ( l 120 mm) maximum above the floor on the wide side of the toilet.
REASON: To meet ADA requirements.
**Section 405.3.1: change to read as follows:
405.3.1 Water closets, lavatories and bidets. A water closet, lavatory or bidet shall not be set closer than
15 inches [351 mm) from its center to any side wail, partition, vanity or other obstruction, or closer than
30 inches (762 nun) center-to-center between toilets or adjacent fixtures. There shall be at least -1-8 2--4
inches (457 609 mm) clearance in front of the water closet or bidet to any wall, fixture or door. Water
closet compartments shall not be less than 30 inches (762 mm) wide and 60 inches (1524 mm) deep. There
shall be at least 1-8 2_~4 inches (457 609 mm~ clearance in front ofa lavato~' to any wall, fixture or door (3cc
97 rPC 8 of 1 11/20/97
**Section 405.6; delete.
**Section 409.2; change to read as follows:
409.2 Water connection. The water supply to a commercial dishwashing machine shall be protected
against backflow by an air gap or backfiow preventer in accordance with Section 608.
**Section 410.1; change to read as follows:
410.1 Approval. Drinking fountains shall conform to ASME A112.19.1, Al 12.19.2 or A1 t2.19.9, and
water coolers shall conform to APl 1010 ntt. .......... : ...... .~: .................. ~.___ L_..,_~ .......
Exception: A drinkina fountain need not be provided in a drinking or dining
establishment.
* *Section 412. 4; changed to read as folio ws:
412.4 Required location and construction. Floor drains shall be installed in the following areas.
1. In public coin-operated laundries and in the central washing facilities of multiple family
dwellings, the rooms containing the automatic clothes washers shall be provided with floor drains
d dily dr i th ti fl ~"~' ~-~:-~ ~'-' ~' ...... :-: ........ ' ........... :~-
Toilet rooms containim, two (2~ or more water closets or a combination of one (1) water
closet and one (II urinal, excevt in a dwelling trait. The floor shall slope toward the floor drains.
3. Commercial kitchens. (In lieu of floor drains in commercial kitchens, the code official may
accept floor sinks.)
**Section 413.4; changed to read as follows:
413.4 Water supply required. All food waste grinders shall be provided with a supply of cold water.
The water supply shall be protected against backflow bv an air gay or with the installation of a backflow
preventer in accordance with Section 608.
11/20/97
"9 of
97 IPC
9
**Section 417.5; changed to read as follows:
417.5 Shower floors or receptors. Floor surfaces shall be constructed of impervious, noncorrosive,
nonabsorbent and waterproof materials.
Thresholds shall be a minimum of 2 inches (51 mm) and a maximum of 9 inches (229 mm). measured fi.om
tot~ of the drain to top of threshold or dam. Thresholds shall be of sufficient width to accommod. ,a~¢ a
minimum twenty-two (22~ inch (559 mm~ d99L
Excention: Showers desiened to comply with CABO/ANSI A 117.1.
**Section 417.5.2; changed to read as follows:
417.5,2 Pans. Floors under shower compartments, except where prefabricated receptors have been
provided, shall be lined and made water tight by the provision of suitable shower pans of approved
material. Floors under pan liners shall be sloped 1/4 inch ver foot to the shower drain. Such pans shall
~urn up on ali sides at least 2 inches (51 mm) above the finished threshold level and shall extend outward
over the threshold and fastened to the outside of the threshold jamb. Pans shall be securely fastened to the
waste outlet at the seepage entrance, making a water-tight joint between the pan and the outlet.
Exception: Floor surfaces under shower heads provided for rinsing laid directly on the ground axe
not required to comply with this section.
**Section 41 7. 7; added to read as follows:
417.7 Test for shower receptors. Shower receptors shall be tested for ~vater tightness by filling with
water to the level of the rough threshold. The drain shall be plueeed in a manner so that both sides of pans
shall be subjected to the test at the point where it is clamped to the drain.
**Section 419.4; delete.
**Section 501.2; changed to read as follows:
501.2 %Vater heater as space heater. A
a ....; .......,1~, , ......... , ..... c ~aa,F (71'C-k. The potability of the water shall be maintained
97 IPC 10 of 1 11/20/97
10
throughout the system.
**Section 502. 5.1; added to read as folio ws:
502.5.1 Electrical requirements. A lighting fixture controlled bv a switch located at the required
passageway openinc, and a receptacle outlet shall be provided at or near the equipment location ill
accordance with the electrical code.
**Section 502. 6; added to read as follows:
502.6 Water heaters above eround or floor. When the attic, roof. mez7~mine or platform in which a
water heater is installed is more than eight (83 feet (2438 mm) above the ~ound or floor level, it shall be
made accessible bv a stairway or permanent ladder fastened to the building.
**Section 504. 7.1; changed to read as follows:
504.7.1 Discharge. The discharge from the relief valve shall be piped full-size separately to the outside
of the building with the end of the pipe not more than two (2/feet (610 mm) nor less than six (61 inches
(152 mm~ above the eround or the floor level of the area receivine the discharge and pointing downward;
or to an indirect waste receptor located inside the building In arcaa -'"-:
appro'~x~mem, v~ The discharge shall be installed in a manner that does not cause personal injury or
property damage and that is readily observable by the building occupants. The discharge from a relief
valve shall not be trapped. The diameter of the discharge piping shall not be less than the diameter of the
relief valve outlet. The discharge pipe shall be installed so as to drain by gravity flow and 3,".all tcrrninatc
...... ~---:--,, .......... ~.__ ~ :_~t.A_ ,, ~ __~ ~,_ ..... ~-~ "~-- The e d of the discharge pipe shall not
be threaded.
**Section 504. 7.2; delete.
**Section 505. l; delete.
9~ IPC 11 of 1 11/2Q/97
11
~*Section 506; added to read as follows:
506. Combustion air and ventilation. Combustion air and ventilation shall be provided as required in
Charter 7. Chapter 8 and Section 1002 of the Mechanical Code as adovted.
**Section 604.4.1; added to read as follows:
604.4.1 State maximum flow rate. Where the State mandated maximum flow rate is more resistiv~ than
those of this section, the State flow rate shall take precedence,
**Tables 605.4 and 605.5; delete "Polybutylene (PB) plastic pipe and tubing".
**Section 606.1; delete items #4, 5 and 6.
**Section 606.2; items #1 and 2 changed to read as follows:
On the fixture supply to each plumbing fixture. :-
On the ~vater supply pipe to each sillcock ~t to freezing.
**Section 607.2.1; delete.
**Section 607.4; change to read as follows:
607.4 Hot water supply to fixtures. The hot water supply to any fixture ,~,~ ...... ~ ..........shall be
installed on the left side of the fixture.
**Section 608.1; changed to read as follows:
97 tpc 12 of 1 11/20/97
12
608.1 General. A potable water supply system shall be designed, installed and maintained in such a
manner so as to prevent contamination fi.om nonpotable liquids, solids or gases being introduced into the
potable water supply through cross-connections or any other piping connections to the system. Back flow
preventer applications shall conform to applicable local revulations. In the absence of other local
reeulations, backflow preventer annlications shall conform to Table 608.1.
**Section 608.17; changed to read as follows:
608.17 Protection of individual water supplies. An individual water supply shall be located and
constructed so as to be safeguarded against contamination in accordance with anplicable local reeulations.
In the absence of other local regulations, installation shall be in accordance with Sections 608.17.1 through
608.17.8.
**Section 702.3; changed to read as follows:
702.3 Building sewer pipe. Building sewer pipe shall conform to one of the standards listed in Table
702.2 70~..~.
**Section 708.3.4; changed to read as follows:
708.3.4 Unper terminal Base-of--s4a~. Each horizontal drain shall be provided with a cleanout at its
uDDer terminal A ~' ........ L_,, t_ ...... :~-~ _. +~.~ ~- .... e ___t. ........... :, _._
Excention: Cleanouts may be omitted on a horizontal drain less that five (5) feet
(1524 mm) in length unless such line is serving sinks or urinals.
**Section 712.5; added to read as follows:
712.5 Dual Pump System. All sumps shall be automatically discharged and. when in any "public use"
occuvancv where the sump serves more than 10 fixture units, shall be provided with dual pumps or eiectors
arranged to function independently in case of overload or mechanical failure. (For storm drainaee, see
Section I 111.)
97 IPc 13 of 1 11/20/97
13
**Section 714.1; changed to read as follows:
~ "'~'""~'"*'~"'""~'" DRAINAGE
......... DESIGN
714.1 Design of drainage system. The sizing requirements for plumbing drainage systems shall be
determined by approved ~ design methods.
**Section 802.1.1; delete the exception.
**Section 802.4; change to read as follows:
802.4 Standpipes. Standpipes shall be individually trapped. Standpipes shall extend a minimum of 18
inches (457 mm) and a maximum of 42 inches (1066 mm) above the trap. Access shall be provided to all
standpipe traps and drains for rodding. No standpipe shall be installed below the floor.
**Section 904.1; changed to read as follows:
904.1 Roof extension. All open vent pipes that extend through a roof shall be terminated at least six
inches ( 152 mm) above the roof, except that where a roof is to be used for any purpose other than weather
protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof.
**Section 904.5; changed to read as follows:
904.5 Location of vent terminal. An open vent terminal from a drainage system shall not be located
directly beneath any door, openable window, or other air intake opening of the building or of an adjacent
building, and any such vent terminal shall not be within I 0 feet (3048 mm) horizontally of such an opening
unless it is at least ~ 3_ feet (510 915 mm) above the top of such opening.
**Section 912.1; changed to read as follows:
912.1 Type of fixture. A combination drain and vent system shall not serve fixtures other than floor
............... or ~n&rect waste receptors.
drains, standpipes, =-"- a'~d ' ....... :-- ' '
11/20/97
97 IPC 14 o'E-' 1
14
**Section 912.2; changed to read as follows:
912.2 Installation. The only vertical pipe ora combination drain and vent system shall be the connection
between the fixture drain ofa ~ standpipe, and the horizontal combination drain and vent
pipe. The maximum vertical distance shall be 8 feet (2438 mm).
**Section 1002.1 O; delete.
**Section 1106.1; changed to read as follows:
1106.1 General. The size of the vertical conductors and leader, building storm drains, building storm
sewers, and any horizontal branches of such drains or sewers shall be based on ~the
' "" ..... '-~'--'-' rainfall
**Section 1201.2; changed to read as follows:
1201.2 Fuel Piping Systems. All fuel piping systems shall be sized, installed, tested and placed in
operation in accordance with the requirements of the Mechanical Code~,,,~; ............... ,,-,,,,,,,,' ,,~ ~,.~,,,,~,,"-- '- ...... '
Cede~, Chapter 13, Fuel Gas Piping,_,--or For reference only. an unamended version of Chapter 1,3 of
the International Mechanical CodeTM is reprinted as Appendix G of this code.
**Chapter 13; deleted.
END
97 rpc 15 of 1 11/~o/97
15
Star-Telegram FED. I.D. NO. 22-3148254
AD ORDER NO. 12483829
400 W.SEVENTH STREET•FORT WORTH,TEXAS 76102 ACCOUNT NO. C I T 5 7
'"E STATE OF TEXAS
inty of Tarrant
Before me, a Notary Public in and for said County and State, this day
personally appeared TAMMIE BRYANT Billing Specialist for the
Star-Telegram, published by the Star-Telegram Inc. at Fort Worth, in Tarrant County, Texas; and
who, after being duly sworn, did depose and say that the following clipping of an advertisement was
published in the above named paper on the following dates:
DATE AD ORDER NO. DESCRIPTION AD SIZE TOTAL INCH!LINE RATE AMOUNT
—. _.
•
2/20ME 12483829 NOTICE OF PUBLIC I358 1x 53L 53 . 79 41 . 87
NOTICE OF PUBLIC ❑2/20-02/2❑
HEARING
Notice is hereby given to all in-
terested persons that the
City Council of the City Coun-
cil of the City of Southlake, - - -- ---- --will be holding a public hear-
ing during the Regular City
Council meeting to be held
on March 3, 1998 at 6:00
p.m., in the City Council - -
Chambers of City Hall 667
North Carroll Avenue,South-
lake,Texas.
Purpose of the hearing is to ---- - - -- --------
consider the second reading
I of the following ordinance.
ORDINANCE NO.695
'AN ORDINANCE ADOPTING
THE INTERNATIONAL
PLUMBING CODE 1997 EDI •
-
TION• PROVIDING FOR THE
ADOPTION OF LOCAL
'MENDMENTS THERETO;
ROVIDING THAT THIS ORDI-
IANCE SHALL BE CUMULA- S
IVE OF ALL ORDINANCES; i
.-ROVIDING A SEVERABILITY
CLAUSE;PROVIDING A SAV-
` INGS CLAUSE PROVIDING SWORN TO BEFORE ME, THIS THE 23th DAY OF FEBRUARY 1998
FOR PUBLICATION IN PAM- ,
FET FORM PROVIDING
FOR PUBLICATION IN THE OFFICIAL -
NEWSPAPER;AND Y p�`��
PROVIDING AN EFFECTIVE �Ig".-NoI,� Notary Public i
DATE. ' •••.. 4 RHONDA R. GOKE
SECTION 6
COMMI
Any person, firm or corpora- j�• �'�
tion who violates, disobeys, a , /\ ;,,4 SStON EXPIRES
omits, neglects or refuses ty r TARRANT COUNTY,TEXAS
to comply with or who re- 4,,- �••• •,A.i SEPTEMBER 8, 1999
sists the enforcement of any ! '
of the provisions of this ordi-
nance shall be fined not
more than Two Thousand
Dollars (52,000.00) for ORIGINAL INVOICE AND RECONCILE WITH MONTHLY STATEMENT. THANK YOU!
each offense.Each day that ,
a violation is permitted to ex-
ist shall constitute a sepa- TEAR ALONG THIS PERFORATION AND RETURN THE LOWER PORTION WITH YOUR PAYMENT----j
_ ' rate offense.
I/s/Sandra L.LeGrand,
City Secretary
City of Southlake
star-Telegram
REMIT TO: 400 W.SEVENTH ST. •FORT WORTH,TEXAS 76102
ACCOUNT AMOUNT
12483829 NUMBER CIT57 DUE 41 . 87
•
PAGE 1 OF IF ANY QUESTIONS, PLEASE CALL(817)390-7885
CITY OF SOUTHLAKE 1
667 N CARROLL AVE PLEASE PAY
SOUTHLAKE , TX 76092-9595 THIS AMOUNT 41 . 87
PLEASE WRITE IN AMOUNT ENCLOSED
Star-Telegram t CU. I.U. !NIL). LL J 1413L04
AD ORDER NO. 12567662
400 W.SEVENTH STREET•FORT WORTH,TEXAS 76102 ACCOUNT NO.
CIT57
THE STATE OF TEXAS
runty of Tarrant
Before me, a Notary Publi in and for said County and State, this day
personally appeared _ \ �m� \ e Ct� Billing Specialist for the
Star-Telegram, published by the Star-Telegram Inc. at Fort Worth, in Tarrant County, Texas; and
who, after being duly sworn, did depose and say that the following clipping of an advertisement was
published in the above named paper on the following dates:
1 DATE AD ORDER NO. DESCRIPTION AD SIZE INCH TOTAL
NTOTAL RATE AMOUNT
3/06ME 12567662 ORDINANCE NO . 69 I358 lx 46L 46 QUOTE 37 . 26
AN
ORDINA CENO.6A95ING 03/06-03/06
THE INTERNATIONAL
PLUMBING CODE 1997 EDI-
TION. PROVIDING FOR THE - - - - -
ADOPTION OF LOCAL
AMENDMENTS THERETO;
PROVIDING THAT THIS ORDI-
NANCE SHALL BE CUMULA-
TIVE OF ALL ORDINANCES;"
PROVIDING A SEVERABILITY
N EGS CLAUSCLAUS PROVIDPROVIDING
FOR PUBLICATION IN PAM-
PHLETFOR PUBLICATIONIN
FORM,' PROVIDING
OIDTHE
OFFICIAL NEWSPAPER;AND
PROVIDING AN EFFECTIVE
DATE.
SECTION 6
Any person, firm or corpora-i ,
tion who ctss, r refuses
omits, neglects or refuses
' to comply with or who re-
sists the enforcement of any Q
of the provisions of this ordi-
nance shall be fined not
more than Two Thousand
Dollars 1S2,000.001 for.
Sl each offense.Each day that)WORN TO THIS THE \ DAY OFi�Q _�``
a violation is permitted to ex-
r t shallofconstitute a sepa- _piiv P.. r RRONDA R. GOKE 1 rate offense. . ",4
PASSED AND APPROVED i"�` �:., COMMISSION EXPIRES Notary Public —n t5 Yl - < —
THIS THE 3RD DAY OF i'. ' ''�ti
ti
REGULAR 9 CITYDU COUNCIL,,,,,%, \ •
"^i
MEETING OF THE CITY OF �tgtf• '•.+rj SEPTEMBER 8,-1999
SOUTHLAKE,TEXAS. ry`E`;•N I', TARRANT COUNTY,TEXAS
/s/Rick Stacy,Mayor
/s/ATTEST:
/s/Sandraty L.
LeGrand,
APPROVED AS TO FORM:
F /s/ty.AornTaylor,Jr., JRIGINAL INVOICE AND RECONCILE WITH MONTHLY STATEMENT. THANK YOU!
Cey
A.--TEAR ALONG THIS PERFORATION AND RETURN THE LOWER PORTION WITH YOUR PAYMENT�„
OFFICE OF
Star-Telegram ��i, sECR T Y
REMIT TO: II* 400 W.SEVENTH ST. •FORT WORTH,TEXAS 76102\
ACCOUNT AMOUNT
12567662 NUMBER CIT57 DUE 37 .26
PAGE 1 Op IF ANY QUESTIONS, PLEASE CALL(817)390-7885
CITY OF SOUTHLAKE (PLEASE PAY
667 N CARROLL AVE THIS AMOUNT1
SOUTHLAKE , TX 76092-9595 37 . 26
PLEASE WRITE IN AMOUNT ENCLOSED