Item 6H, 6I and 6J
Legends of Southlake
APPLICANT: Brown Company
REQUEST: Approval of Zoning Change and Concept Plan, a Site Plan for Lots 1 and 2, and a Preliminary Plat for Legends of Southlake for the development of six (6) office/warehouse buildings
LOCATION: 2301 Crooked Lane
ZA13-108 / ZA13-109 / ZA13-110
Cases
6H. Zoning Change and Site Plan for Legends
6I. Site plan for lots 1 & 2
6J. Preliminary Plat
Aerial View
South Kimball Ave.
CISD Eubanks Intermediate School and Dawson Middle School.
Dragon Stadium
Crooked Lane
Legends of Southlake
Previously Approved Concept Plan
Previously Approved Conceptual Elevations
Summary Data Chart
6H. Concept Plan
Development Regulations:
This property shall be subject to the development regulations for the “I-1” Light Industrial District, and all other applicable regulations with the following exceptions:
Parking agreements will be in place prior to permitting to satisfy the combined parking requirements for the development.
To facilitate a contiguous development, buffer yards will not be required along internal boundary lines.
Street width requirement reduced to 31’ from curb back to curb back to reduce concrete, add turf area and eliminate on-street parking. Propose to fire lane the entire 30’ of drive.
Reduced front yard setback to 25’ to provide flexibility in the orientation of buildings.
Allow for Dean Way as a public street to dead-end at CISD property. In lieu of a round-a-bout a dedicated and permanent emergency access and common access easement will be platted in
the drive aisles east of lot 6 and north of lots 5 and 6 to create a fire access loop. Dean Way will be gated at the property line of CISD and will be equipped with Knox Box access for
emergency access. All gate access will be under the ontrol of Southlake Public Safety and CISD only. It is anticipated that the gate will remain closed to ingress and egress by the public
with the exception of event and game days at Dragon Stadium.
6H. Tree Conservation
6H. Overall Landscape Plan
6H. Building Materials
6I. Site Plan – Lot 1
6I. Building One Elevations
West Elevation
East Elevation
North Elevation
South Elevation
6I. Lot 1 Landscape Plan
6I. Site Plan – Lot 2
6I. Building Two Elevations
West Elevation
East Elevation
North Elevation
South Elevation
6I. Lot 2 Landscape Plan
6J. Preliminary Plat
Variances
A
B
C
D
E
F
G
Dead End Street
Intersection Distance
100-feet required
63-feet provided
November 21, 2013 (ZA13-108):
Approved (5-0) granting the requested variances to stacking depth and dead end streets and subject to Concept Plan Review Summary No. 2, dated November 15, 2013 and the staff report
dated November 15, 2013, also noting the applicants agreement to place an 8-foot masonry fence along the boundary line with the Kaposta’s and noting the applicants willingness to provide
the specific type of masonry fence prior to going to City Council.
PLANNING & ZONING COMMISSION
December 3, 2013 (ZA13-108):
Approved (6-0) to the submittal of the building rendition presented to council this evening and granting the variance to dead end streets Section 5.03 of the subdivision ordinance, the
variance to the stacking depth and driveway spacing as presented.
CITY COUNCIL