Item 6J13 CITY OF SOUTHLAKE Department of Planning & Development Services STAFF REPORT October 9, 2013 CASE NO: ZA13-089 PROJECT: Trinity Partners Professional Office Building EXECUTIVE SUMMARY: REQUEST DETAILS: Trinity Partners Commercial Real Estate is requesting approval of a Site Plan for the purpose of constructing two new single story office buildings in two development phases on property located at 450 N. Kimball Avenue, Southlake, Texas. SPIN Neighborhood # 4. Trinity Partners Commercial Real Estate is requesting approval of a Site Plan for the purpose of constructing two new single story office buildings in two development phases. The parent Tract is currently unplatted, however, there is a two -lot plat showing application being processed (ZA13-090) concurrently. Lot 4 is planned to be constructed first with a 3,212 square foot single story office building. Lot 3 is being conceptually planned and will require a revised site plan approval prior to construction. The following is the proposed site data summary chart provided by the applicant: SITE DATA sj-"ARY CHART LOT 3 LOT 4 r4LMSER Cr- LOTS 1 LOT I LOT LAND USE DE8IGNAT]CN PROFESSIONAL OFFICE PROFESSIONAL OFFICE €XIBTNG ZONING 114LIGNT MDUSTRIAL 11-LIGHT KXZTRIAL PROF'CeFp L15F5SSI OFF1C 981ONA CFFI GRO89 ACREAGE 098 AGRE51I5,498 SOFT. 0.40 ACRE91r1222 SOFT. NE7 ACREAGE 036 AC1PE91E.A98 SOFT. 0A0 ACRE&M222 SQFT. TOTAL 5UILDM6 AREA BOW SQFT. f-OTAL A W-OFFICE LEE 3 12 SQFT.fTOTAL A/CJ-OFFICE USE a 212 SQFT. (PORCH) a 215 SOFT, 3272 SOFT. (TOTAL) 9421 60FL (TOTAL) PERCENTAGE OF IBLOG, COVERAGE 21% COVERAGE 20% 00VFRAGE Z<WARE FOOTAGE BY LVW 3 50 SOFT. (TOT AIC) 12 fTOTA AICJ OPEN SPAU AREA 1 8l b $GtT, PERGESJTAGE pF OPEN $PACE 41% 35% PERCENTAGL OF OUTSIDE 670RAC-Z 0% 0% MAXIM I HEIGHT OF STRUCTURE 1 STORY 1 STORY eZ'-9' BUILDING HEIC44T7 R€QUIR€D FARKW. S SPACES . V300 FOR 200 SOFT. & SPACES * V300 FOR 2$12 SOFT, TOTAL PARSMG REWIRED IS SPACES REGIUIRED 16 SPACES F;zLQUIRED PARKING PROVIDED B SPACES - 2 SHApEG FACTS LOT 4 19 SPACES - 2 SHAMP FROM LOT 3 REQUIRED LOADING SPAO€S 0 SPACES 0 SPACES PROVIPED LOADING SPACES 0 SPACES 0 SPACES 1MPERVIOU6 COVERAGE MAX 85% COVERAGE/ MJ14 S.QFT, 851 COVERAGE/ 14k39 S.RFT. IMPERVIGUS COVERAGE 532.CO1+LRAGE/8231 SOFT. V3%COVEAAGLIII214 5QFT. Variance: Tree Preservation Ordinance No. 585, as amended, requires at least 70% minimum existing tree cover be preserved. There is a single 24" Oak tree shown in the future connecting driveway extending through Lot 3. Case No. ZA 13-089 ACTION NEEDED: ATTACHMENTS: STAFF CONTACT Case No. ZA 13-089 1) Conduct Public Hearing 2) Consider approval of a Site Plan (A) Background Information (B) Vicinity Map (C) Plans and Support Information — LINK TO PRESENTATION (D) Site Plan Review Summary No. 2, dated September 27, 2013 (E) Surrounding Property Owners Map & Responses (F) Full Size Plans (for Commission and Council Members Only) Dennis Killough (817) 748-8072 Lorrie Fletcher (817) 748-8069 OWNER: BACKGROUND INFORMATION Bo-Fam Investments, LTD APPLICANT: Trinity Partners Commercial Real Estate PROPERTY SITUATION: 450 N. Kimball Avenue LEGAL DESCRIPTION: Tract 3A1, T. Mahan Survey, Abstract No. 1049 LAND USE CATEGORY: Mixed Use CURRENT ZONING: "I-1" Light Industrial District HISTORY: The current 1-1 zoning was placed on the property with the adoption of the Zoning Map in 1989. There is no other development history on this property and remains vacant today. CITIZEN INPUT: The SPIN Neighborhood # 4 liaison determined that a SPIN meeting for this project was not necessary. SOUTHLAKE 2030 PLAN: Consolidated Land Use Plan Under the Southlake 2030 Consolidated Land Use Plan the subject property is designated as Mixed Use. The subject property has been designated as Mixed Use since 1993. Typically, the Mixed Use designation is intended for medium- to higher -intensity office buildings, hotels, commercial activities, retail centers, and residential uses. Nuisance -free, wholly enclosed light manufacturing and assembly uses that have no outdoor storage are permitted if designed to be compatible with adjacent uses. TRANSPORTATION ASSESSMENT: North Kimball Avenue in this location is classified as an "88' A4D," or a 4-lane divided arterial with 88' of right of way. Turn lanes may be necessary at key intersections and the design speed is 35-40 mph. Typically no on -street parking is permitted. Case No. ZA 13-062 Attachment A Page 1 Existing Area Road Network and Conditions * Based on the 2013 City of Southlake Traffic Count Report Traffic Impact General Office Building (710) 1 3,212 1 35 5 4 1 * Vehicle Trips Per Day * AM -In, AM -Out, PM -In and PM -Out are peak hour generators on a weekday * Based on the ITE: Trip Generation Manual, 7" Edition TREE PRESERVATION: The tree protection plan shows zero existing trees on proposed Lot 4 resulting in no trees affected during construction of that phase. An existing 24" oak tree is shown within the future fire lane for Lot 3. Tree mitigation will be addressed at time of site plan for Lot 3. P&Z COMMISSION: October 3, 2013; Approved (6-0) subject to Site Plan Review Summary No. 2, dated September 27, 2013 and the Staff Report dated September 27, 2013. STAFF COMMENTS: Attached is Site Plan Review Summary No. 2, dated September 27, 2013. The applicant does not expect to construct the dumpster enclosure and associated drive shown on the site plan for Lot 4 at this time as the generation of trash from this project is insufficient to justify the need for a dumpster. Republic Services does offer a curb side pickup service for commercial buildings with smaller amounts of trash. The applicant will, however, have a cross use, access and construction agreement with Lot 3 should the dumpster become necessary in the future. Lot 3 is being conceptually planned with this application and will require a revised site plan approval prior to construction. Case No. Attachment A ZA13-062 Page 1 Vicinity Map Trinity Professional Office Building jo Cn a V NNrr ui L0 LO a 'a A W --Ain � [V � 14 1 A Cef Q fD I C� g R aLLLI a � s :000 ccy 2100 2110 2120 2150 S.H. 114 292 ZA13-989 J�\ Site Plan 0 315 630 2300 O co IT 4 91 1,230 � Feet Case No. ZA 13-089 Attachment B Page 1 Plans and Support Information kallL 1� ? $all�6 0 1ia M Ali � l g m ' 71�v, r RRgg 3 IN q� P 5 ILA Case No. Attachment C ZA13-089 Page 1 M. J. WRIGHT & A5sA"ETMAIL* I0-CITIES BLVD., STE. ALAN� HILLS TX 7616268.5555 F:817.268.5555 MJW@MJWRIGHT.COM Date: August 26, 2013 From: Nathan E. Hallmark, Project Manager M. J. Wright & Associates, Inc. Reference: Trinity Partners Commercial Real Estate Office Building Site Plan Submittal - City of Southlake, Tarrant County, Texas, Written -Narrative M. J. Wright and Associates, Inc. in conjunction. with Trinity Partners Commercial Real Estate are proposing a 3,212 square foot office building, to he occupied by Trinity Partners Commercial Real Estate, to be constructed on lot 4, T. Mahan No. 1049 Addition. The property is located on North Kimball Avenue just north of State Highway.114 and west of Kimball Avenue. The building conforms to the uses as designated under the current zoning I (light industrial), therefore no zoning change is being requested at this time. There are no variances being requested at this time for this proposed project. The building's exterior fagade is being proposed to be a combination of stone and wood siding to conform to the masonry requirements set forth by the city ordinances. The overall design of the facade and floor plan also conform to the articulation requirements as set forth by the city ordinances. If you have any questions, comments, or concerns please feel free to contact us at any time for assistance. 1" Sincerely, Nathan E. Hallmark, Project Manager M. J. Wright & Associates, Inc. 8233 Mid -Cities Boulevard, Suite "A" North Richland Hills, Texas 76182 Phone (817) 268-5555 Fax (817) 268-5558 Case No. Attachment C ZA13-089 Page 2 Building Elevations 4.rmrfw. Wr4 EAST ELEVATION E ARTICU-AV Q146a AM M0.lGr FW� m.Fr P�R'lLId�LITIGE lYILMlk flM.EGi PCCIli!'r yp yoRrN�blLL '�4 A 9E' ir: [f Pf�ARAi.�et ^ems M+'!Ee !E'TQEl0. Y,]q] Snd�EN9 E FH I• "M rC� g P.NFf V wta i t�t�,ia i icon MASONRY TABLE .<.® rw-Fw.. ILEST ELEVATION t ARTICOLATICN ID146RAM W IOR. M. f9/r+1F r Don-�1. M'r ] i i, r. f W Wl .d. SOH dO➢m?! 1N INR. Y ]pf.H M0.lGT •,••E: m PAIn1t1lm rll^IE!lIGiA1 tJTICE �NLG- ] eartxPr'- !Wti ElOCRIFrICM. �MLXLV fp, �LCF ] 1 a xrt4 ohiE a IK�F]l4r�pl. O�PrE*OER �i. Pp] c.i![�VlEIE IWiCO Case No. Attachment C ZA13-089 Page 3 MASONRY TABLE uu — naepur. wow. .ren. oay. .0 eor. e.. eon.w. n.mrre. x�n+euv. w. uvr. aee eorrrm.. n6orc. 67d la MASCNRY TABLE w*uw. v. war. wen �o.r. w. ecw,.w SOUTH ELEVATI SOUTH ELI=VATION a_,AFRTICULATIOH DIAGRAM LOT 9 A A. T, Mq�yW >.q. IvaE /DDITILN PR R T MAM- 7FUM pARMR6 PRdRW&44L 7= eurtAw. FFh^JECT K'1pA' A•.u.E 4Er+AL DEBGR�W T. MWw[ N0.1M9 AVD"WK Ll9 a DAT! GP rR6rA1L4T10Ni ElrTlJ'!�R b, S61f c,� WlER IAl9•@C] Case No. ZA 13-089 Attachment C Page 4 SITE PLAN / CONCEPT PLAN REVIEW SUMMARY Case No.: ZA13-089 Review No.: Two Date of Review: 09/27/13 Project Name: Site Plan —Trinity Professional Office Building (proposed on Lot 4, T. Mahan No. 1049 Addition) APPLICANT: Trinity Partners Commercial Real Estate Brad Bowen, Managing Partner PO Box 96011 Phone: 214-693-7424 ARCHITECT: M.J. Wright & Associates, Inc. Michael J. Wriaht (Main Contact Phone: 817-268-5555 Email: brad@trinitypartnerstexas.com Email: mjw@mjwright.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 09/16/13 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT LORRIE FLETCHER AT Ifletchera-ci.southlake.tx.us / (817) 748-8069 or DENNIS KILLOUGH AT dkillouahaci.southlake.tx.us / (817) 748-8072. The proposed future development and removal of the one (1) existing tree on Lot 3 will result in non-compliance with Tree Preservation Ordinance No. 585, as amended. Please provide a letter requesting a variance to the Tree Preservation Ordinance. 2. The information provided on the Bufferyard Summary Chart is incorrect. The north bufferyard required is a 10 foot `D'. The number of some of the provided/required plantings is incorrect and inconsistent with what is shown on the Landscape Plan. Provide corrections. 3. Show bufferyard labels on the site plan. 4. The Site Data Summary states an incorrect maximum allowed impervious coverage of 85%. The "I-1" Light Industrial zoning district allows for a maximum impervious coverage of 80%. 5. A revised site plan approved by City Council following a recommendation by the Planning & Zoning Commission will be required prior to a building permit being issued for Lot 3. 6. The recording instrument for off -site access easement shall be provided prior to permitting. 7. Provide an executed and filed copy of the cross access reciprocal parking agreement prior to permitting. This agreement should also address the shared use of trash enclosure. Tree Conservation/Landscape Review E-mail: kmartin@ci.southlake.tx.us Keith Martin Landscape Administrator Phone: (817) 748-8229 Case No. ZA13-089 Review No. One Dated: September 3, 2013 Number of Pages: 2 Case No. Attachment D ZA13-089 Page 1 Project Name: Spec Office Building for Trinity Partners (Site Plan) Contact: Keith Martin Phone: (817) 748-8229 Fax: (817) 748-8077 The following comments are based on the review of plans received on August 26, 2013 . Comments designated with a number may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z or City Council. It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. --------------------------------------------------------------------------- --------------------------------------------------------------------------- TREE CONSERVATION COMMENTS: There is one (1) existing 24" Post Oak tree on the property (proposed Lot 3) and it is located within the proposed parking lot area of the future office building. The tree is proposed to be removed. The applicant will need a variance for the removal of 100% of the existing trees from the property. LANDSCAPE AND BUFFERYARD COMMENTS: Please label all bufferyards on the Site Plan and Landscape Plan. 2. The east bufferyard adjacent to N. Kimball Avenue is required to be a 10' — D type bufferyard instead of a 10' — E as provided. Please correct the bufferyard type and associated plant material quantities. 3. There is no bufferyard provided along the west property boundary line. The west and north bufferyards are required to be a 10' — D type bufferyard. Please provide the required 10' - D type bufferyards adjacent to the west and north property boundary lines. 4. The south bufferyard is required to be a 10' — F1 type bufferyard instead of a 5' — A as proposed. Please correct the south bufferyard to reflect the minimum of a 10' — F1 bufferyard as required. 4. The parking lot landscape island within the parking spaces facing N. Kimball is less than 12' wide. All parking lot landscape islands are required to be a minimum of 12' wide from back -of - curb to back -of -curb. 5. Show the location of the proposed monument sign on the Landscape Plan. 6. All parking planter islands in parking areas shall contain a minimum of one (1) canopy tree with the remaining area in shrubs, ground cover, ornamental grasses or seasonal color. No turf grass may be planted within parking lot landscape islands. Planter islands which have light poles for lighting the parking areas may substitute two (2) understory/accent trees for the required canopy tree. If there is a light pole proposed in the east parking island please reflect it on the landscape plan. 7. The development is proposed to be zoned 1-1 and the proposed interior landscape area and plant material calculations have been calculated for an 0-1 zoned property. The 1-1 interior landscape calculations are based on 20% of the total building footprint instead of 50% of the building footprint as for an 0-1 zoned property. You may want to change the interior landscape calculations and plant material to reflect the requirements of an 1-1 zoned property. Case No. Attachment D ZA13-089 Page 2 # Denotes required items. Denotes informational items. Public Works/Engineering Review Steve Anderson, P.E. , CFM Civil Engineer Phone: (817) 748-8101 E-mail: sanderson@ci.southlake.tx.us Case ZA13- Review 1 Dated 9/10/13 Number of No. 089 No. Pages: Project Name: Spec Office Bldg for Trinity Partners Contact: Steve Anderson, Civil Phone: (817) 748-8101 Fax: (817) 748-8077 Enaineer Email: sanderson@ci.southiake.tx.us The following comments are based on the 8/26/13 /t is the applicant's review of plans received on responsibility to contact the department representative shown above and make modifications as required by the comment. GENERAL COMMENTS: 1. Label utilities as "Public" or "Private". DRAINAGE COMMENTS: 1. Indicate whether storm lines will be Public or Private 2. Need to show that there is no adverse impact upstream or downstream from the additional runoff to the creek. WATER COMMENTS: 1. The water services cannot tie to the fire hydrant lead. The water service taps will need to tie to the existing 8-in water line. INFORMATIONAL COMMENTS: Submit 4 copies of the civil construction plans (22" X 34" full size sheets) and a completed Construction Plan Checklist as part of the first submittal for review directly to the Public Works Administration Department. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City's website. A ROW permit shall be obtained from the Public Works Operations Department (817) 748- 8082 to connect to the City's sewer, water or storm sewer system. Case No. Attachment D ZA13-089 Page 3 A Developer's Agreement will be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be acceptable to Public Works prior to placing the Developer's Agreement on the City Council agenda for consideration. A separate bond will be required for the Maintenance Bond and bound only unto the City of Southlake for a period of two years for all development projects. The Maintenance Bond cannot be tied to the Performance and Payment Bond in any way. Any hazardous waste being discharged must be pretreated Ordinance No. 836. Fire Department Review Kelly Clements Assistant Fire Marshal Phone: (817) 748-8671 E-mail: kclements@ci.southlake.tx.us Case No. ZA13-089 Review No. 1 Dated: 09-04-2013 Number of Pages: 1 Project Name: Trinity Partners Contact: Kelly Clements, Assistant Fire Marshal Phone: 817-748-8233 Fax: 817-748-8181 The following comments are based on the review of plans received on 0910312013. Comments may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. --------------------------------------------------------------------------- --------------------------------------------------------------------------- GENERAL COMMENTS: All commercial buildings are required to have Knox Box rapid entry systems installed. Boxes can be ordered at www.knoxbox.com or contact the Fire Marshal's Office. FIRE LANE COMMENTS: Fire apparatus access needs to be provided within 150 feet of all exterior portions of the perimeter of buildings on a "hose -lay" basis for un-sprinkled buildings. Fire apparatus access needs to be an all-weather surface, asphalt or concrete, 24 feet wide and able to support the imposed loads of fire apparatus. (A minimum of 80,000 pounds GVW) Fire lanes require a minimum 30 foot inside turn radius and a minimum 54 foot outside turn radius. (per 2009 I.F.C. Sec. 503.2.4) Fire lanes that are to be dead-end until the next phase of construction need to be provided with an approved turn -around for fire apparatus if the dead-end is more than 150 feet long. Case No. Attachment D ZA13-089 Page 4 FIRE HYDRANT COMMENTS: Hydrants to have Hydra-Storz connections with butterfly vanes on pumper outlet for five -inch diameter hose. Informational Comments: No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. All mechanical equipment must be screened of view right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. All lighting must comply with the Lighting Ordinance No. 693, as amended. All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and will require construction standards that meet requirements of the Airport Compatible Land Use Zoning Ordinance No. 479. All development must comply with the underlying 1-1 Light Industrial zoning district regulations and the Non -Residential Development Overlay Zone. See Zoning Ordinance No. 480, Sections 26 & 43. Development must comply with all requirements in Zoning Ordinance No. 480, Section 33.21, Building Color Standards for Non -Residential Buildings. The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. Denotes Informational Comment Case No. Attachment D ZA13-089 Page 5 11 Surrounding Property Owners 5 1 4 10 SPO Owner Zoning Land Use Acreage Response 1 Victron Stores Lp C3 Retail Commercial 0.89 NR 2 Sandco Holdings Lp SP2 Retail Commercial 0.54 NR 3 Texas Petro Corp III SP2 Retail Commercial 1.16 NR 4 Tate, John T SP2 Retail Commercial 0.92 NR 5 Mayse, Richard A SP2 Retail Commercial, Mixed Use 0.75 NR 6 Hagar, Stephen T AG Office Commercial, Retail Commercial 4.08 NR 7 Chamathil, Varghese AG Retail Commercial 1.67 NR Etux Sara 8 Ivester, Emory O Etux AG Office Commercial, Low Density 3.62 NR Marlene Residential 9 Jte Investments Ltd Etal 11 Mixed Use 0.68 NR Retail Commercial, Public/Semi-Public, 10 Nci Group Inc SP2 6.13 NR Mixed Use Retail Commercial, Public/Semi-Public, 11 Nci Group Inc SP2 9.33 NR Mixed Use Responses: F: In Favor Notices Sent: Responses Received: O: Opposed To U: Undecided Eleven (11) None NR: No Response Case No. ZA 13-089 Attachment E Page 1