Item 4IM E M O R A N D U M May 9, 2012 To: Honorable Mayor and City Council From: Shana Yelverton – City Manager Subject: Ordinance No. 1032: Water System Master Plan Action Requested: Consider approval for first reading of the proposed Southlake 2030 Water System Master Plan. Background Information: The Southlake 2030 Plan is the city’s guide to determine the community’s goals, aspirations and resource allocations. The Southlake 2030 Plan consists of multiple elements; the Water, Waste Water, Storm Water Plan is one of these elements. The Southlake 2030 Water, Waste Water, Storm Water Committee has finished its work on the Water component of this plan and has made the recommendation that City Council consider approval of the three components (1: Water; 2: Waste Water; 3: Storm Water) separately. The Water System Master Plan is a comprehensive analysis and plan for the city’s water distribution, storage, facility improvements and construction. It is intended to guide future water utility decisions. The plan projects the city’s ultimate water demand based on build-out of the city and prioritizes capital improvements needed to meet the water demand. The City of Southlake contracted with Neel-Schaffer/Cheatham & Associates to develop the Water, Waste Water, Storm Water Master Plan. Existing documents such as previous plans, system maps and construction documents were utilized as a basis for the Water System Master Plan update. Neel- Schaffer/Cheatham & Associates also met with Southlake officials and staff and performed limited site visits to verify data and better understand the priorities of the City of Southlake. Existing population and growth data from the North Central Texas Council of Government (NCTCOG) was also used, along with data from previous engineering studies, reports and designs performed for the City. This City of Southlake Water System Master Plan was performed on several separate elements of the system and the results are presented in the report. Major elements of the study included Water Demand Projection, Water Supply, Storage, Pump Stations, Distribution System, Recommended System Improvements, and Exhibits/System Maps. In addition to prioritizing the short and long term needs of the city, the plan also identifies significant projects currently under construction such as a 20” distribution line along Hwy 114 and a 30” supply line into the T.W. King Pump Station. The 20” line will be completed in Spring of 2012 and the 30” line is scheduled for completion in Spring of 2013. The City of Southlake has implemented water conservation measures including public education and mandatory water use restrictions. A more comprehensive water conservation plan is recommended to include consideration of a water reuse program. Financial Considerations: Adopting the plan in FY 2012, provides staff and Council the ability to use the plan as a guide for funding recommendations for FY 2013 and to move forward next fiscal year on the development of the water conservation plan. Strategic Link: The Water System Master Plan relates to all focus areas of the strategy map. Citizen Input/ Board Review: All meetings of the Southlake 2030 Water, Waste Water, Storm Water Committee are open to the public. The committee held two (2) public meetings stth (February 1 and March 19, 2012) to discuss, review, and develop water system recommendations. In addition, a SPIN meeting was held April 23, 2013 for the Water System Master Plan. The SPIN summary report is included as Attachment “C”. Planning & Zoning Commission: May 3, 2012; Approved as presented (7-0). Legal Review: None. Alternatives: Recommend modifications to the proposed Water System Master Plan or move forward with the Water System Master Plan as presented. Attachments: (A) Ordinance 1032 (B)Southlake 2030 Water System Master Plan (C)SPIN Meeting Summary Report ORDINANCE NO. 1032 AN ORDINANCE ADOPTING THE WATER SYSTEM MASTER PLAN AS AN ELEMENT OF THE SOUTHLAKE 2030 PLAN, WHEREAS, a Home Rule Charter of the City of Southlake, Texas, was approved by the voters in a duly called Charter election on April 4, 1987; and, WHEREAS, comprehensive plan elements every four years, WHEREAS , the City Council recognizes that the Water System Master Plan is an element of the Southlake 2030 Plan, WHEREAS , the City Council has determined that the Water System Master Plan complies with the Southlake 2030 Vision, Goals, & Objectives, WHEREAS, the City Council has deemed that the Water System Master Plan has been formulated with adequate public input, WHEREAS, the City Council has deemed that the recommendations in the Water System Master Plan development of the City, WHEREAS, the City Council has determined it is in the best interest of the provision of potable water for city residents and businesses, NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS, THAT: Section 1. All of the findings in the preamble are found to be true and correct and the City Council hereby incorporates said findings into the body of this ordinance as if copied in its entirety. Section 2 . 1Water System Master Plan of the Southlake 2030 Plan. Section 3 . The different elements of the Comprehensive Master Plan, as adopted and amended by the City Council from time to time, shall be kept on file in the office of the City Secretary of the City of Southlake, along with a copy of the ordinance and minute order of the Council so adopting or approving the same. Any existing element of the Comprehensive Master Plan which has been heretofore adopted by the City Council shall remain in full force until amended by the City Council as provided herein. Section 4 . This ordinance shall be cumulative of all provisions of ordinances of the City of Southlake, Texas, except where the provisions of this ordinance are in direct conflict with the provisions of such ordinances, in which event the conflicting provisions of such ordinances are hereby repealed. Section 5. It is hereby declared to be the intention of the City Council that the phrases, clauses, sentences, paragraphs and sections of this ordinance are severable, and if any phrase, clause, sentence, paragraph or section of this ordinance shall be declared unconstitutional by the valid judgment or decree of any court of competent jurisdiction, such unconstitutionality shall not affect any of the remaining phrases, clauses, sentences, paragraphs and sections of this ordinance, since the same would have been enacted by the City Council without the incorporation in this ordinance of any such unconstitutional phrase, clause, sentence, paragraph or section. Section 6. The City Secretary of the City of Southlake is hereby authorized to publish this ordinance in book or pamphlet form for general distribution among the public, and the operative provisions of this ordinance as so published shall be admissible in evidence in all courts without further proof than the production thereof. Section 7. This ordinance shall be in full force and effect from and after its passage and publication as required by law, and it is so ordained. PASSED AND APPROVED on the 1st reading the _____day of _____, 2012. __________________________ MAYOR ATTEST: __________________________ CITY SECRETARY PASSED AND APPROVED on the 2nd reading the _____ day of ______, 2012. _________________________ MAYOR ATTEST: __________________________ CITY SECRETARY APPROVED AS TO FORM AND LEGALITY: _________________________________ CITY ATTORNEY DATE:___________________________ ADOPTED:_______________________ EFFECTIVE:______________________ CITY OF SOUTHLAKE WATER SYSTEM MASTER PLAN 2012 A Study of SUPPLY DISTRIBUTION SYSTEM STORAGE PUMPING PREPARED BY: TBPE Firm 2697 2233 AVENUE J, SUITE 107 ARLINGTON, TEXAS 76006 (817) 548-0696 TABLE OF CONTENTS TOPIC PAGE Executive Summary 1. Background and History ......................................................................................................... 1 2. Population Analysis / Water Demand Projection .................................................................. 4 Population Residential Growth Population and Water Demands Residential/Non-Residential Projected Residential / Non-Residential Build Out 3. Supply, Conservation and Reuse .......................................................................................... 7 4. Ultimate Storage Requirements ........................................................................................... 10 Total Ground Storage Required Total Elevated Storage Required 5. Booster Pump Stations ......................................................................................................... 15 Interim Pumping Conditions Future Pumping Conditions 6. Water Distribution System Analysis ..................................................................................... 24 Domestic/Non-Residential Requirements Fire Flow Requirements Distribution System Maps 7. Recommended System Improvements ............................................................................... 28 Tables: Table 2.1 Historical Water System Demand Summary Table 2.2 Water System Demand Summary Table 4.1 Ground Storage Recommendation Table 4.2 Elevated Storage Requirements Table 4.3 Existing Elevated and Total Storage – TCEQ Requirements Table 4.4 Proposed Build-out Elevated and Total Storage – TCEQ Requirements Table 4.5 Total Water Storage Capacity Table 5.1 Pump Station Total Operating Firm Capacity Table 5.2 Existing Pump Station Capacity – TCEQ Requirements Table 5.3 Ultimate Pump Station Capacity – TCEQ Requirements Table 5.4 Ultimate Required Pump Station Capacities Table 5.5 Pump Station Capacity Requirements Summary Table 6.1 High and Low Pressure Plane Demand Summary Table 7.1 Capital Improvement Plan Projects Table 7.2 Projects Probable Cost Summary Figures: Figure 5.1 Existing Pearson Road Booster Pump Station Pumping Arrangement Figure 5.2 Existing T.W. King Booster Pump Station Pumping Arrangement Figure 5.3 Ultimate Pearson Road Booster Pump Station Pumping Arrangement Figure 5.4 Ultimate T.W. King Booster Pump Station Pumping Arrangement Figure 5.5 Pumping Requirements for Pearson Road Pump Station – High Pressure Plane Figure 5.6 Pumping Requirements for Pearson Road Pump Station – Low Pressure Plane Figure 5.7 Pumping Requirements for T.W. King Pump Station – Low Pressure Plane Figure 5.8 Total System Pumping Requirements – Low and High Pressure Planes Exhibits: Exhibit 1.1 Capital Improvements Plan Exhibit 1.2 Year 2012 – Pressure Contours and Fire Flow Exhibit 1.3 Year 2015 – Pressure Contours and Fire Flow Exhibit 1.4 Year 2020 – Pressure Contours and Fire Flow Exhibit 1.5 Build-out Pressure Contours and Fire Flow Exhibit 1.6 Ultimate (Build-out) System Map Appendix: Southlake 2030 Water Matrix Executive Summary The City of Southlake contracted with Neel-Schaffer/Cheatham & Associates to develop Master Plan Updates which are being used in the development of the Southlake 2030 Plan – Water, Wastewater and Stormwater. We utilize existing documents such as previous plans, system maps and construction documents as a basis for the Water System Master Plan Update. Neel- Schaffer/Cheatham & Associates also met with Southlake officials and staff and performed limited site visits to verify data and better understand the priorities of the City of Southlake. Existing population and growth data from the North Central Texas Council of Government (NCTCOG) was also used, along with data from previous engineering studies, reports and designs performed for the City. This City of Southlake Water System Master Plan was performed on several separate elements of the system and the results are presented in this report. Major elements of the study included Water Demand Projection, Water Supply, Storage, Pump Stations, Distribution System, Recommended System Improvements, and Exhibits/System Maps. Based on population projections from the NCTCOG, total water demand is expected to increase from a peak day demand of 26.94 million gallons per day (MGD) in 2012 to a peak day demand of 34.22 MGD at Ultimate Build-out of the City of Southlake in the year 2025 and beyond. Water supply and pumping capacity recommendations are based on these peak day projections. Based on industry standards and Southlake historical data, we assume a Peak Hour Demand of 2.0 times the peak day demand. Analyses and recommendations for the distribution system and elevated storage are based on the peak hour demand, since these elements of the system must meet the peak hour demand even if it exceeds the supply and pumping capacity. The modeling and analysis that Neel-Schaffer/Cheatham performed, indicated several areas that need immediate improvements and also longer term needs based on future growth. Significant projects currently under construction are a 20” distribution line along Hwy 114 and a 30” supply line into the T.W. King Pump Station. The 20” line will be completed in the Spring of 2012 and the 30” line is scheduled for completion in the Spring of 2013. Other needed capital projects have been prioritized as Tier 1, Tier 2, and Tier 3 projects. The highest priority projects (Tier 1) identified are shown below: Install pressure reducing valves to allow emergency water flow between the higher and lower pressure planes of the water system. Add an additional 5 million gallon ground storage tank and two additional 5 MGD pumps at the T.W. King Pump Station to pump water supplied by the new 30” supply line. Upgrade existing pumps at the Pearson Road Pump Station to increase capacity in the Higher Pressure Plane. Add a 16” distribution line from the Pearson Road Pump Station to Johnson Road. Longer term projects include looping of key distribution lines, an additional 1.5 million gallon elevated storage tank and additional water supply, such as adding pumps at the Caylor Tank in Fort Worth. Detailed recommendations are included in Section 7.0. The City of Southlake has implemented water conservation measures including public education and mandatory water use restrictions. A more comprehensive water conservation plan is recommended to include consideration of a water reuse program. The first phase, information gathering, has begun to evaluate future water supply options. These options include additional pumps at the Caylor Tank in Fort Worth, alternate water supply sources, and the potential for water reuse options. CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 1.0: Background and History In 2010, the City contracted with Cheatham & Associates to provide Water and Wastewater System Master Plan Updates. The purpose for the updates is to assist the City’s 2030 Master Plan Committee by identifying and prioritizing infrastructure that will require improvements to meet the projected growth anticipated by the year 2030. The City of Southlake incorporated in approximately 1956 as a rural sparsely developed bedroom community. At that time, residents were dependent on wells as their sole water supply source. By 1985, the City had grown to a population of approximately 5,000 people. The City had four water wells, including 2 Trinity Sand and 2 Paluxy Sand. There was one 500,000 gallon elevated tank and two 300,000 gallon ground storage tanks. Since the total capacity of the four wells was 1.3 million gallons per day (MGD), it was apparent that the City needed a surface water supply to provide for future growth. In addition, the two Trinity Wells were high in minerals and salts, which made the water undesirable to the customers. When Grapevine Lake was constructed in 1955, the water rights were granted to the City of Dallas, Park Cities, and the City of Grapevine. Since the City of Southlake had no water rights to Grapevine Lake and had no other available raw water sources, the construction of a treatment plant was not an option. Therefore, the City officials began to explore other potential sources for the City’s long-term supply. These sources included the Trinity River Authority (TRA), the City of Grapevine, and the City of Fort Worth. The Trinity River Authority (TRA) has a treatment plant serving a number of cities in the area including Grapevine and Colleyville and was contacted as a potential supply source. However, due to the high combined cost of purchasing water from TRA and constructing the necessary supply lines to connect onto the system, City of Southlake officials decided against pursuing TRA as a source of supply. Another option was obtaining water from the City of Grapevine, which operates a plant to treat raw water from Grapevine Lake. However, this allocation of water from the lake to the City of Grapevine was not large enough to satisfy Grapevine’s own water demands, 1 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 necessitating the purchase of additional water from the TRA. Due to this shortage, the City of Grapevine could not supply water to the City of Southlake. The final option involved obtaining water from the City of Fort Worth. After considering several factors, including an abundant supply of water from the City of Fort Worth and the relatively close proximity of a supply connection, City officials chose this option as the supply source for the City of Southlake. A 5.0 million gallon (MG) ground storage tank belonging to the City of Fort Worth is located just west of S.H. 377 on Alta Vista Road, which is on the west side of Keller. Therefore, it was necessary to construct the supply line through Keller. The cost of this supply line was shared between the City of Southlake and the City of Keller in a joint venture agreement. This new supply line resulted in the City of Keller constructing a ground storage tank and pumping station north of F.M. 1709, on Pearson Lane, to serve the eastern portion of their city. A pumping station was built at the Alta Vista ground storage tank, and a 36” and 30” supply line was constructed through Keller along F.M. 1709, and connected to the Keller storage tanks on North Pearson and the City of Southlake’s system at Pearson Road and F.M. 1709. The total capacity of this line is 20 MGD, 10 MGD for Keller and 10 MGD for Southlake. The line and pump station at Alta Vista have been in operation since 1986. Originally, it pumped water directly into the 1.5 MG elevated tank on North White Chapel, and a 0.5 MG elevated tank at Bicentennial Park. From 1986 to the present, several additions have been made to the City’s distribution system allowing the City to keep pace with the residential and commercial growth, including additional pumps at Alta Vista. In 1996, The City constructed a 5.0 MG ground storage tank and booster pump station at Pearson Road and F.M. 1709. This allowed the Alta Vista pumps to discharge into a ground storage tank, rather than the elevated tanks. As a result, additional water could be delivered to the City of Southlake. The water was then pumped into the system and into the elevated tanks from the Pearson Road Facility. A second 1.5 MG elevated storage tank was constructed at Bicentennial Park in 1989, and the 0.5 MG elevated storage tank, which was at the park, was moved to the Florence Road Site. This tank relocation intentionally set a higher overflow elevation than the other elevated tanks in the city, which created an “upper pressure plane”. This hydraulic grade change was necessary to serve the west central portion of the City, since it is at a much higher elevation than the remainder of town. Next, a third 1.5 MG elevated storage tank 2 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 was constructed in 1998 at the Miron Site along F.M. 1709, west of the Woodland Heights subdivision. This tank boosts the pressure in the eastern portion of town, and provides better fire protection to this vicinity. And finally, in 2006 the City replaced the existing 0.5 MG elevated tank at the Florence Road site with a 1.5 MG elevated tank to serve the upper pressure plane. The City of Fort Worth has a ground storage tank west of Keller known as the Caylor Tank. The cities of Southlake and Keller jointly constructed a 42” water line from the Caylor Tank through Keller, which is connected to the Pearson Road facilities of both cities. This supply line provides a second source of supply to both cities from Fort Worth. Currently the water flows by gravity in the 42” line from the Caylor site to the Pearson Road tanks of Keller and Southlake with a total capacity of 29 MGD. In 1998, a 5.0 MG ground storage tank and pump station was built on T.W. King Road, North of S.H. 114. This facility will serve as a future second delivery point of water supply from the City of Fort Worth. 3 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 2.0: Population Analysis / Water Demand Projections Data Source In 2007, City officials updated the water and wastewater impact fees based upon the most recent land use and population projections adopted by the City Planning Department (2025). The planning staff subsequently, published a report containing a water and wastewater plan conforming to these expected projections for the City of Southlake’s water and wastewater service area. The Service area only includes the City limits since there is no extra-territorial jurisdiction (ETJ) area to be annexed or served by the City of Southlake. The City is currently in the process of updating the Future Land Use Map (2030). These Land Use and Population Projections shown below are a result of this recent updating of the 2007 Impact Fee Study. Residential Growth Population, housing and acre estimates can be derived from the land use study for three periods of time: 1) Current as of October 1, 2009. The current population is estimated to be 26,650 people. This represents approximately 77.96% of the ultimate population and the ultimate water and wastewater requirements for the residential sector, which is the predominate land use projected for Southlake. 2) Growth for the ten-year period from 2012 to 2020. The growth for the ten-year period is estimated to be 5,000 people. This means that 14.62% of the ultimate residential sector utility demands will be added in the ten-year period. When added to the existing residential base, 92.56% of the water demands from the residential sector are estimated to be made by the end of the ten-year period 3) Ultimate capacity or growth for the City to 2025 and beyond. The ultimate population estimate is 34,188 people. The remaining population, 2,538 or 7.42% of the ultimate utility demand from the residential sector, is projected to occur between 2020 and 2025. 4 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Population and Water Demands As stated above, the City of Southlake year 2009 population has been estimated to be 26,650 by the North Central Texas Council of Governments (NCTCOG). Using the 2025 Land Use Assumptions Report the system build-out population is projected at 34,188. To review the projected water demands the following sources were used: The City of Southlake’s water production data and the historical water use data over the last five years indicates an increasing trend in the per capita water usage. This trend is principally due to increased use of irrigation systems. The results of the last five years of consumption data Table 2.1 and the projected per capita use are illustrated in . Based upon the historical increase in per capita water usage, it is recommended that the average day per capita water demand of 385 gallons per capita day (GPCD) be used for the projection of future water demands. Table 2.1 Historical Water System Demand Summary Water Demands (MGD) Estimated Demand YearPopulationAverage Day Peak Day Peak Hour* Factor GPCD 2005 21,519 6.251 15.646 31.292 2.503 290 2006 25,654 11.014 20.049 40.098 1.820 429 2007 25,700 6.749 16.334 32.668 2.420 263 2008 26,100 8.525 25.390 50.780 2.978 327 2009 26,650 8.139 19.799 39.598 2.433 305 2010 26,650 8.494 18.322 36.644 2.157 319 2011 26,650 12.210 21.925 43.850 1.796 458 * Peak Hour Estimated Based upon Peak Day Multiplied by 2.0. As shown in 2009 the system wide population was 26,650, and the per capita water usage was an average day water demand of 8.454 MGD or 317 GPCD. The water distribution system needs to be capable of supplying the peak day demands with the supply coming from Fort Worth. A peak hour to peak day ratio of 2.0 was selected for the water system analysis for the City of Southlake. The distribution system will typically supply the peak hour demand using the pumping facilities in combination with the elevated storage tanks. The method shown above was used to compute the average day, peak day and peak demands for the years 2015, 2020 and ultimate (2025). 5 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 2.2 Water System Demand Summary AveragePeakPeak Day Day Hour Year Population Demand Demand Demand (MGD) (MGD) (MGD) 2012 26,91710.3626.9453.89 2015 29,24511.2629.2758.54 2020 31,71712.2131.7563.50 Ultimate 34,18813.1634.2268.44 Projected Residential and Non-Residential Build-Out / Ultimate Demand Table 2.2 As shown in , the projected population of Southlake at build-out is 34,188 persons. The water system must serve this population, as well as the non-residential development. It is projected that the residential and non-residential build out will occur in approximately 15 years or 2025. Growth rates in water consumption are assumed to be the same for the residential and non-residential sectors. While the overall growth rate of the non-residential sector will likely be higher, this sector also has a great conservation potential as it includes large water users. The peak day demand is a factor of 2.6 times the average day, and the peak hour demand is 2.0 times the peak day. 6 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 3.0: Supply, Conservation, and Reuse Supply The City of Southlake currently receives its water supply from the City of Fort Worth through two pipelines. Up to 10 MGD is pumped through a 30” and 36” pipeline from the Alta Vista Tank in Fort Worth to the Pearson Road Pump Station in Southlake. Water flows by gravity through a 42” pipeline from the Caylor Tank in Fort Worth to the Pearson Road Pump Station in Southlake. A 30” supply line is under construction from this 42” line at the intersection of Florence Road and Pearson Road, through the Town of Westlake to the existing T.W. King Pump Station in Southlake. As part of the negotiations with Westlake, Southlake agreed to give Westlake 2 MGD capacity from the 30” line. Based on the negotiated agreements between the cities, the 42” and 30” lines will provide Keller with 7 MGD, Westlake with 2 MGD, and Southlake with 20 MGD. This new 30” line will allow the T.W. King Pump Station to contribute over 40% of the peak demand with the result being less water needed from the Pearson Road Pump Station. With the 10 MGD capacity in the 30”/36” line from Alta Vista and the 20 MGD capacity in the 42” and 30” lines from Caylor, the existing total supply capacity for the City of Southlake is 30 MGD. An 8” emergency interconnection exists with the City of Grapevine for emergency use only, in the event of failure of one of the systems. Increasing this to a 12” emergency interconnection and adding a second 8” emergency interconnection are planned to help with emergency fire flow in the event of system failure. As shown in this report, the future build-out peak day demand is projected to be 34.22 MGD. To meet successive peak day demands, the City mustneeds to evaluate alternatives due to increase water the supply shortfall. Additional study is needed to evaluate these alternatives, which may include the following: Construct a pump station at the existing Fort Worth Caylor Tank Site to increase the supply capacity from Fort Worth by approximately 65 MGD (assuming Keller takes an additional 2 MGD). Evaluate alternative supplies that may be available such as The Trinity River Authority (TRA) or Upper Trinity Regional Water District. This would provide the City with a secondary supply source and would provide a supply redundancy. 7 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Evaluate options for reuse infrastructure that would reuse wastewater plant effluent for large water users such as irrigation for parks, golf courses, and large commercial/industrial users. Water reuse options could include partnership with a wastewater plant operator such as the TRA Denton Creek Wastewater Plant and would be part of a citywide water conservation plan. Evaluate alternatives and timing of a combination of 2 or more of the above mentioned alternatives, that would provide the most feasible overall solution for the City. The first phase of this study, data gathering and development of alternatives is underway, and future phases will include concept design, cost estimates and comparison of alternatives. Conservation With the limits on potable water supplies for municipal services, increasing, Southlake and other local governments have enacted conservation measures to reduce per capita demands. Such conservation programs have focused on education, low water use fixtures/landscaping, alternative water supplies, modified rate schedules and irrigation audits. Water systems that have seen success in reducing their demands have used a combination all these aspects tailored to their community. Education programs have varied from simple mail outs, to active programs promoting low demand irrigation, low volume fixtures, and on-going school programs. Some programs have been tied to city ordinances where days and hours of irrigation are limited and customers not following such requirements receive focused attention. The landscaping community is also promoting the use of native vegetation which is more tolerant to seasonal precipitation variations and more resistant to native pests and diseases. Low water use ordinances are becoming increasingly common in the U.S. Many home improvement stores provide as part of their inventory various low and no flow fixtures along with irrigation controls to limit use in the event of rainfall. Low water use landscaping has gained popularity where new developments or new construction is required to use such systems. Reduction in water impact fees may be used to entice such construction. Many of these ordinances are also passed with new tiered utility rate structure that encourages lower water use or provides a lower cost by using an alternative water supply. Southlake’s water consumption is heavily dominated by residential water use, followed by commercial use. Industrial water use is not a major component of the city’s demand. 8 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 During the summer months, demand is heavily impacted by irrigation uses. The irrigation uses during the Summer months can account for approximately 60% of the total water demand. With the trend toward needing to reduce the city’s overall water consumption, the community must find ways to decrease its water consumption wherever and whenever possible. As a recommendation of the 2030 Water Plan, the Committee would recommend that staff undertake the development of an overall Water Conservation Master Plan. The Committee envisions that this plan would provide the following information: 1. An analysis of the community’s demographics as it relates to the use of potable water; 2. Estimate the effectiveness of recent water conservation and drought contingency measures; and, 3. Develop a 10-year plan for effective water conservation measures that could be used to reduce the consumption of potable water based upon the city’s specific demographics through the implementation of water conservation measures. Reuse and Alternative Water Supply Perhaps the single program that directly reduces per capita usage is alternative water supply for irrigation. Extensive programs throughout the U.S. have been developed that provide reuse water back to customers. In many instances this water is provided free or at a reduced cost versus potable water rates. Initial programs in the U.S. have utilized treated wastewater meeting what has been deemed “public access” standards. This level of treatment, which requires wastewater to be filtered and treated with enhanced disinfection, is acceptable for irrigation. Water reuse also requires pumping and distribution systems back to the customers. Frequently, with the existing customers and subdivisions, the cost to provide the distribution network is prohibitive. Many reuse system have focused on new development areas such that the infrastructure can be added as the new subdivisions come on line. Secondly, major existing water users such as golf courses, parks and schools can be more effectively retrofitted if planned in conjunction with new development areas. 9 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 4.0: Ultimate Storage Requirements The following section summarizes an evaluation of the storage requirements for the City based on criteria used by the industry. These criteria are typically more stringent than TCEQ requirements and take into consideration additional factors including operational flexibility and fire protection. Total Ground Storage Required: The City has two 5 million gallon tanks at the Pearson Road site, and one 5 million gallon tank at T.W. King. The two tanks at Pearson are adequate to provide storage to meet approximately one-third of the ultimate peak day demands of 34.22 MGD. The one 5 million gallon tank at the T.W. King facility can meet approximately 15 percent the peak day demands; however a second tank is planned in the future. Once this second tank at the T.W. King site is on line, the City would have 20 million gallons of water in ground storage plus 7.5 million gallons of elevated storage for a total of 27.50 million gallons. This would allow the City to operate for approximately 19 hours without any additional supply if an emergency situation rendered the supply unavailable. (14 hours based on ground storage only.) The recommended amount of ground storage is the equivalent of 12 hours of the Table 4.1 maximum day demand. displays the existing and proposed ground storage capacities with the amount of drain time available to meet peak day demands. With the proposed additional 5.0 MGD ground storage at the T.W. King Pump Station, there will be 14 hours of the maximum day demand at ultimate build-out. 10 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 4.1 Ground Storage Recommendation Total Hours of Existing and MaximumExistingTotalProposedHours of Day GroundGroundGroundGround Storage DemandStorage Storage Storage with Proposed (1) (MGD) (MG) Available(MG) Improvements* 2012 26.9415.0 13.4 15.0 13.4 2015 29.2715.0 12.3 15.0 12.3 (2) 2020 31.7515.0 11.3 20.0 15.1 Ultimate 34.2215.0 10.5 20.0 14.0 (1) Hours of drain time available under maximum day demands (2) Includes additional 5.0 MGD at T.W. King Total Elevated Storage Required: The design criteria used to analyze existing elevated storage tank capacity is the ability to provide adequate storage for peak hour demands plus emergency storage for fire protection. It is typically assumed that half of the elevated storage tank capacity is used to meet peak hourly demands in excess of the peak day rate (equalization volume), while the other half of the tank is used for fire protection and emergency conditions (fire/emergency volume). According to the Insurance Services Office (ISO), the maximum fire flow a municipality is required to provide is 3,500 gpm for a 3-hour duration. While typical residential and commercial fire flow requirements are 1,000 gpm and 1,500 gpm, respectively, some industrial fire flows can approach the 3,000 to 3,500 gpm range or greater. Therefore, for the elevated storage requirement a fire flow requirement of 3,500 gpm for a 3-hour duration was selected. Table 4.2 provides a summary of the elevated storage requirements using two criteria. Criteria 1 represents twice the required equalization volume, while Criteria 2 represents the equalization volume plus the fire/emergency volume. The upper pressure plane is proposed to have 2486 connections at build-out. This is approximately 20 percent of the total number of connections for the entire city (12,432). Therefore, the build-out peak day of the upper pressure plane is approximately 20 percent of 34.22 MGD or 6.84 MGD. Similarly, the peak day of the lower pressure plane is projected to be 27.38 MGD at build- out. 11 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 4.2 Elevated Storage Requirements Proposed Upper Pressure Plane Criteria 1 Criteria 2 Build-out Peak Day Demand (MGD) 6.84 6.84 Build-out Peak Hour Demand (MGD) 13.68 13.68 40% of Peak Hour Demand (MGD) 5.47 5.47 (1) Required Equalization Volume (MG) 0.68 0.68 (2) Required Fire Volume (MG) N/A 0.63 (3)(4) Required Total Volume (MG) 1.37 1.31 Minimum Required (MG) 1.37 Proposed Lower Pressure Plane Criteria 1 Criteria 2 Build-out Peak Day Demand (MGD) 27.38 27.38 Build-out Peak Hour Demand (MGD) 54.76 54.76 40% of Peak Hour Demand (MGD) 21.90 21.90 (1) Required Equalization Volume (MG) 2.74 2.74 (2) Required Fire Volume (MG) N/A 0.63 (3)(4) Required Total Volume (MG) 5.48 3.37 Minimum Required (MG) 5.48 (1) The volume required to meet 40% of the peak hour demand for a duration of 3 hours (2) The volume required to meet a 3,500 gpm fire flow for 3 hours (3) Twice the required equalization volume (4) Required equalization volume plus the required fire flow Based on the calculations and a peak hour factor of 2.0, a fourth 1.5 million gallon elevated tank on the low pressure plane at the T.W. King elevated tank site will be required. The City currently owns this site, which is north of the existing T.W. King Pump station site. It is recommended that the City’s Water System Master Plan be reviewed and updated every two to three years, to determine if additional storage tanks are necessary to provide service to the projected water demands, based upon any changes in the land use and growth patterns of the City. Four pressure reducing valves we recommended at the boundary between the higher and lower pressure plane to provide additional fire flow by allowing water to automatically flow across this boundary under emergency conditions. The criteria established by the State Board of Insurance (Key Rate Schedule) requires a ground storage tank capable of holding a capacity based upon 130 gallons per capita for a 24-hour period or 4.44 million gallons of ground storage for 34,188 persons and an 12 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 elevated storage capable of holding a 10-hour supply. Elevated storage capable of holding a 10-hour supply of water yields 1.85 million gallons of elevated storage. Therefore, the City’s existing ground and elevated storage tanks more than meet the requirements of The State Board of Insurance. Table 4.3 and Table 4.4 The following summarize the existing elevated and total storage requirements based on TCEQ criteria: Table 4.3 Existing Elevated and Total Storage - TCEQ Requirements Total Storage (MG) Elevated Storage (MG) Pressure ExistingTCEQExcess of TCEQExcess of PlaneConnections Existing* MinimumTCEQ ExistingMinimumTCEQ Lower 7,710 17.00 1.54 16.61 4.50 0.77 4.11 Upper 1,965 4.00 0.39 3.64 1.50 0.20 1.14 Total 9,675 21.0 1.94 20.25 6.00 0.97 5.25 * Pearson ground storage 7.5 MG lower, 2.5 MG upper Table 4.4 The following is a summary of the proposed build-out elevated and total storage requirements based on TCEQ criteria: Table 4.4 Proposed Build-out Elevated and Total Storage - TCEQ Requirements Total Storage (MG) Elevated Storage (MG) Estimated ExistingExisting Pressure Build-outandTCEQExcess of andTCEQExcess of PlaneConnections Proposed* MinimumTCEQ ProposedMinimumTCEQ Lower 9,946 22.00 1.99 20.01 6.00 0.99 5.01 Upper 2,486 5.50 0.50 5.00 1.50 0.25 1.25 Total 12,432 27.50 2.49 25.01 7.50 1.24 6.26 *Pearson ground storage 7.5 MG lower, 2.5 MG upper 13 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 4.5 The following illustrates the size and location of existing and proposed storage tanks. Table 4.5 Total Water Storage Capacity Location TypeSize (MG) Existing Elevated 1.50 Dove Road at White Chapel Elevated 1.50 Bicentennial Park Elevated 1.50 Miron Site Elevated 1.50 Florence Site (Upper Pressure Plane) Ground 5.00 T.W. King Site Ground *10.00 Pearson Site Sub Total (Existing Storage) 21.00 Future T.W. King Site (Lower Pressure Plane) Elevated 1.50 T.W. King Site Ground 5.00 Sub Total (Future Storage) 6.50 TOTAL STORAGE (Build-out) 27.50 *7.5 MG Lower, 2.5 MG Upper 14 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 5.0: Booster Pump Stations Interim Pumping Conditions The City of Southlake currently has two pump stations. One is located at F.M. 1709 and Pearson Lane, which is the City boundary on the west. The second pumping station is on T.W. King Road just north of S.H. 114. This station is also situated on the west City limit line. The Pearson Road pumping station site has two 5.0 million gallon ground storage tanks in place, and the T.W. King location has one existing 5.0 million gallon tank with a provision for a second 5.0 MG tank in the future. Due to the interim supply conditions mentioned in the previous section, the City has been using the T.W. King pump station on a limited basis during the past two years. This is accomplished by pumping water through the distribution system, to the T.W. King storage tank, during the off peak periods at night. The tank fills each night during summer months and the pump station pumps into the system during the peak time demands to assist in meeting the system peak day demands. Therefore, both pump stations are used for the peak periods in summer months. This process has enabled the City to keep pace with the increased demand over the last two years. However, with continued City growth, the T.W. King Pump station facility must be capable of contributing more to the future system demands. Once the new 30” supply line is in place, and is capable of filling the T.W. King tank from the Fort Worth supply, both pump stations will be available for continuous operation. Construction of this line is scheduled for completion in the spring of 2013. Until then, the City will only be able to use the T.W. King facility on a limited basis. This places a strain upon the system during summer months, and does not allow for any interruption of the Pearson Road facility, without possibly resulting in a water shortage situation. The City implemented a pump maintenance rotation program in 2007. Based upon run times of the pumps, the pumps will be reconditioned approximately every 5 years. Future Pumping Conditions Table 2.2, On it was determined that the ultimate peak hour demand will be approximately 68.44 MGD. This demand must be met from a combination of pumping and supply from elevated storage. The peak day demand at build-out was shown to be 34.22 MGD. The pump stations should be capable of supplying 1.25 times the peak day demand or 42.78 MGD, with one pump out of service at each station. Additional peak hour flow will be 15 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 provided by the elevated tanks. Of this amount (42.78 MGD), 25.25 MGD should be supplied by the Pearson Road pump station, and 17.53 MGD from the T.W. King Pump Station. This is based upon the water flow projections for the T.W. King and Pearson Road Pumping Stations. The projections indicate that 41 percent of the build-out peak day be supplied by the T.W. King Pump Station, and 59 percent of the build-out peak day be supplied by the Pearson Road Pump Station. Therefore the flow to be supplied at the Pearson Road Pump Station is 42.78 MGD x 59 percent = 25.25 MGD. The Pearson Road Pump Station serves both the high pressure plane and the low pressure plane. The ultimate system peak hour demand to be furnished by the Pearson Road station is 25.25 MGD. The ultimate build-out of the upper pressure plane is estimated to be 2486 connections, or 20 percent of the estimated total City build-out connections of 12,432. Therefore the peak hour demand on this station for the upper pressure plane is 20 percent of 42.78 MGD or 8.55 MGD. A flow of 8.55 MGD is required by the high pressure plane and 16.70 MGD by the low plane at the Pearson Road Station. This pump station was constructed in 1996, and currently has three pumps for the high pressure plane, and four pumps for the low pressure plane. The required pumping capacity at build-out is 17.53 MGD all on the lower plane. The T.W. King facility only serves the low pressure plane. The required pumping capacity at build-out is 17.53 MGD all on the lower plane. This station currently has three pumps. 16 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Tables 5.1, 5.2, 5.3 and 5.4 The following illustrate the existing pump station firm capacities, TCEQ requirements, and ultimate pumping capacity. Table 5.1 **Pump Station Total Rated *Operating Operating Firm YearCapacity Capacity Capacity GPMGPMMGD Pearson BPS – Upper Pressure Plane Pump 1 2250 2360 6.80 Pump 2 2250 2360 Pump 3 2250 2360 Pearson BPS – Lower Pressure Plane Pump 1 3474 4600 Pump 2 3474 4600 19.90 Pump 3 3474 4600 Pump 4 3474 4600 T.W. King - Lower Pressure Plane Pump 1 3474 4350 12.50 Pump 2 3474 4350 Pump 3 3474 4350 39.20 Total Pumping Capacity * Operating Capacity: Pumping capacity while operating against system pressure. **Total Operating Capacity: Capacity with largest pump out of service and operating against system pressure. Table 5.2 Existing Pump Station Capacity - TCEQ Requirements Ék«——ÆY¢Üù¡ ¼Ç ±`†Æ•kÔ ɔk”ZІêІ£”б`††£”ÐÜêëk« ɱª£ªª†Ã£ª¢Üù¡¢Ð±´£ªª†Ã£ª¡¼£†±—ÆY¢¼£†±¡ Ô±©»®éôéïðìòëðëèìíîòìðêòêê Ë°°»®ïôçêëïòëðéêíêòèðïòéð TCEQ Requirement: 0.60 GPM/Connection 17 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 5.3 Ultimate Pump Station Capacity - TCEQ Requirements Ék«——ÆY¢Üù¡ ¼Ç †Ã«†±`†Æ•kÔ ɔk”kñ£k†Â†£”б`††£”ÐÜêëk« ɱª£ªª†Ã£ª¢Üù¡¢Ð±´£ªª†Ã£ª¡¼£†±—ÆY¢¼£†±¡ Ô±©»®çôçìêêòððìëîíìòîíèòëç Ë°°»®îôìèêïòëðêðíèòëëîòïë Table 5.4 Ultimate Required Pump Station Capacities Additional Ultimate Capacity Existing Operating Pressure Plane Capacity Required Required MGD Capacity (MGD) (MGD) Pearson Upper 8,55 6.80 1.75 Pearson Lower 16.70 19.90 0 T.W. King Lower 17.53 12.50 5.02 Total 42.78* 39.20 6.77 *Total ultimate pumping capacity is 1.25 times the peak day demand from Table 2.2 Table 5.5 As shown in , the Pearson Road pumping station’s low plane pumps have an existing pumping capacity of 19.90 MGD. The build-out requirement for the lower pressure plane is 19.90 MGD. Therefore the existing pumps are adequate for build-out. The existing high pressure plane pumps at the Pearson Road facility must be upgraded in the future. Currently, there are three pumps with an operating capacity of 6.80 MGD. In the year 2015, each of the two low capacity pumps need to be replaced with higher capacity pumps resulting in an operating capacity of 8.55 MGD to the high pressure plane. This will provide the high pressure plane with 100% of the ultimate requirement of 8.55 MGD. Table 5.5 also indicates the pumping requirements for the T.W. King Pump Station. As shown, the existing pump operating capacity is 12.50 MGD. Two additional pumps will be needed in the future to obtain an ultimate operating capacity of 17.51 MGD. 18 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 5.5 Pump Station Capacity Requirements Summary Required Additional Total PumpAvailable Capacity Pump YearCapacity* Capacity Required Capacity Improvement MGD MGD MGD MGD Pearson BPS - Higher Pressure Plane 2012 6.74 6.80 06.80 Change out impellers upsize motors and electrical 2015 7.22 6.80 0.428.55increase from 6.08 MGD to 8.55 MGD 2020 7.72 8.55 08.55 Build-out 8.55 8.55 08.55 Pearson BPS - Lower Pressure Plane 2012 14.44 19.90 019.90 2015 14.07 19.90 019.90 2020 15.05 19.90 019.90 Build-out 16.68 19.90 019.90 T.W. King - Lower Pressure Plane 2012 12.50 12.50 012.50 Add one or two 5.0 MGD pumps 2015 14.79 12.50 2.2918.79 2020 15.82 18.79 018.79 Build-out 17.55 18.79 018.79 Total Both Pump Stations – Both Pressure Planes 2012 33.68 39.20 039.20 2015 36.08 39.20 2.7147.24 2020 38.59 47.24 047.24 Build-out 42.78 47.24 047.24 *Required pump capacity is 1.25 times the water system demand from Table 3.2, split between the two pump stations and two pressure planes. Each pumping station is currently providing service to the water system. Both stations were designed so that additional pumps could be added, as required, to enable the pumping capacity to meet or exceed the system demands. 19 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Figure 5.1 The following illustrates the existing pumping equipment at the Pearson Road pump station. Upper Pressure Plane 6.80 MGD Total Capacity against system pressure (2 Pumps Operating) Existing ExistingExisting 2250 gpmEmpty Spare 2250 gpm2250 gpm PumpSlot PumpPump 19.90 MGD Total Capacity against system pressure (3 Pumps Operating) Low Pressure Plane ExsitingExsitingExsitingExsiting 3474 gpm3474 gpm3474 gpm3474 gpm PumpPumpPumpPump Figure 5.1:Existing Pearson Road Booster Pump Station Pumping Arrangement Figure 5.2 The following illustrates the existing pumping equipment at the T.W. King Booster pump station. Empty SpareEmpty SpareEmpty SpareEmpty Spare SlotSlotSlotSlot 12.50 MGD Total Capacity against system pressure (2 Pumps Operating) ExistingExistingExisting Empty Spare 3474 gpm3474 gpm3474 gpm Slot PumpPumpPump Figure 5.2:T.W. King Booster Pump Station Pumping Arrangement 20 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Figure 5.3 The following illustrates the ultimate pumping equipment at the Pearson Road pump station. Upper Pressure Plane 8.55 MGD Total Capacity against system pressure (2 Pumps Operating) FutureFutureFuture Empty Spare 3800 gpm3800 gpm3800 gpm Slot PumpPumpPump 19.90 MGD Total Capacity against system pressure (3 Pumps Operating) Low Pressure Plane ExsitingExsitingExsitingExsiting 3474 gpm3474 gpm3474 gpm3474 gpm PumpPumpPumpPump Figure 5.3:Ultimate Pearson Road Booster Pump Station Pumping Arrangement Figure 5.4 The following illustrates the ultimate pumping equipment at the T.W. King Booster pump station Future Empty SpareEmpty SpareEmpty Spare 3474 gpm SlotSlotSlot Pump 18.79 MGD Total Capacity against system pressure (3 Pumps Operating) FutureExistingExistingExisting 3474 gpm3474 gpm3474 gpm3474 gpm PumpPumpPumpPump Figure 5.4:T.W. King Booster Pump Station Pumping Arrangement 21 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 14 12 10 Upsize Pumps to 8.55 8 MGD 6 4 2 0 201020122014201620182020202220242026202820302032 Year System Demand CurvePump Capacity Figure 5.5: Pumping Requirements for Pearson Road Station High Pressure Plane 25 20 15 10 5 0 201020122014201620182020202220242026202820302032 Year System Demand CurvePump Capacity Figure 5.6: Pumping Requirements for Pearson Road Station Low Pressure Plane 22 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 20 18 Add 2-5 MGD Pumps 16 14 12 10 8 6 4 2 0 201020122014201620182020202220242026202820302032 Year System Demand CurvePump Capacity Figure 5.7: Pumping Requirements for T.W. King Station Low Pressure Plane 50 45 40 35 30 25 20 15 10 5 0 201020122014201620182020202220242026202820302032 Year Cumulative System Demand CurveCumulative Pump Capacity Pump Capacity - Pearson (High Plane)Pump Capacity - Pearson (Low Plane) Pump Capacity - T.W. King Figure 5.8: Cumulative System Pumping Requirements Low and High Pressure Plane 23 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 6.0: Water Distribution System Analysis Domestic/Non-Residential Requirements The City’s water system was analyzed for the 2012, 2015, 2020, and ultimate water demands (2025). This analysis was performed on a computer using the program WaterCAD version by Bentley Systems, Inc. software. Due to variations in the terrain and ground elevations throughout the City, the City’s water system is split into two pressure planes. The majority of the City is served by the low pressure plane, which is governed by the elevated storage tanks with an overflow elevation of 801 feet. The remainder of the City is served by the high pressure plane with an overflow elevation of 860 feet. The model analysis can be structured to simulate any water demand on the system. If the results indicate that there is adequate water pressure throughout the entire system, it is assumed that the distribution system, which is either in place at the time, or is proposed in the future, is adequate for that situation. The worst situation for analysis is the peak hour condition. If the system can meet the peak hour flows, it can also meet any situation, which may occur from a water system demand standpoint. The model analysis results produce the pressures throughout the system. The goal of the analysis is to determine if the system can maintain a minimum pressure of 35 PSI, while providing the system with the peak hour demands. If however, the analysis indicates inadequate pressure anywhere in the system, some improvement to the system will be required. Additional lines are added which are indicated on the ultimate system plan, until the repeated analysis indicates that the low pressure situation has been corrected. This process results in recommended lines, which will be required prior to that particular frame of time. Simulating the water demands of the 2012 peak hour with the existing distribution system was the initial model run. A similar analysis was made of the peak hour demands for the high and low pressure plane systems for 2012, 2015, 2020, and 2025 conditions. This Table 6.1. analysis was based upon the following system demands in This analysis 24 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 indicates the need for additional water lines and looping of existing lines in the distribution system. Table 6.1 High and Low Pressure Plane Demand Summary Water Demands Water Demands (Peak Day)(Peak Hour) Low High Low High Pressure Pressure Pressure Pressure YearPlane Plane Total Plane Plane Total 2012 21.55 5.39 26.94 43.11 10.78 53.89 2015 23.39 5.89 29.27 46.77 11.77 58.54 2020 25.38 6.37 31.75 50.74 12.76 63.50 Ultimate 27.38 6.84 34.22 54.68 13.76 68.44 Fire Flow Requirements The determination of the amount of Minimum Fire Flow Required (MFFR), or the minimum flow rate necessary to provide sufficient water for fire protection, is dependent on many factors which may vary throughout the City limits. Some factors that may affect the MFFR include the following: Type of Construction (Noncombustible, Fire Resistive, etc.) Distance between Structures Square Footage of Structure Occupancy Classification (manufacturing, non-manufacturing, etc.) Sprinkled or Non-sprinkled Structures There are several methods that have been developed by different agencies and institutions to determine the MFFR for a particular facility. These methods consist of a MFFR formula to represent the dependent factors mentioned above, as well as others not listed. From a water system planning prospective, it would be very difficult to determine the MFFR for all locations throughout the City for both the existing and future developments. Even if this information was available, there most likely will be several areas throughout the city that would not be economically feasible to provide the MFFR solely from the city’s water distribution system. At these locations, the owner(s) of the future development must provide additional fire protection facilities, such as interior sprinkler facilities, and/or private booster pumps to obtain the MFFR. In water system planning, the Public Works Department, Fire department, and City Engineers should work together to mutually agree 25 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 on a MFFR that not only adequately provides fire protection, but also is economically feasible. For the purposes of this water system study, we have determined the MFFR to be 1750 (GPM), and a minimum pressure of 20 PSI. Furthermore, we made other assumptions necessary for the fire flow analysis. These assumptions are as follows: 1. Booster Pumps Active with Largest Pump Out-of-Service 2. Elevated Storage Tanks Approximately One-Half Full 3. Minimum Residual Pressure at Fire Flow Location = 20 (PSI) 4. Minimum Residual Pressure for System = 20 (PSI) 5. Fire Flow analysis during peak hour demand We developed a computer model of the City’s water system and with these assumptions, analyzed the amount of fire flow available at water line intersection points or junction nodes throughout the system. We performed this analysis on the existing system, as well as the water system for 2015, 2020, and 2025 or (Ultimate build-out). We then compared the results of the computer model for each of these years to the previously determined MFFR. This comparison indicated several existing dead end lines that we recommend be upgraded to a minimum size of 8” diameter. In addition, there are a few locations where we recommend the construction of new water lines to provide a “looped” system necessary to obtain the MFFR. We also recommend pressure reducing valves (PRVs) be installed at four locations between the high and low pressure planes. This will allow water to flow from the low plane to the high plane if the pressure in the high plane becomes lower than the pressure in the low plane during an emergency situation. This results in vastly improved fire flow capacity in the high plane, since the low plane pumps and elevated tanks will now be able to contribute during a fire flow event. In addition, the valves may also allow for the upper plane to contribute to the lower plane under certain pressure Exhibits 1.2 and 1.3 conditions. illustrate the improvement in fire flow protection that the PRV valves will provide. Distribution System Maps The City’s distribution system has been analyzed to determine what will be required from a water distribution standpoint to provide adequate service to the potential water customers. Exhibits 1.2 through 1.5 In the appendix there are , which illustrate the distribution lines required for the years 2012, 2015, 2020, and build-out. It was determined in the system analysis that these additional lines will be necessary to meet minimum system pressures and to provide fire protection. 26 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Each map in the exhibits is color coded to indicate the lines and sizes, which should be in place prior to the year indicated on the map. The City staff can use these maps for planning purposes to budget for future water projects. It is recommended that the water system model and analysis be updated every year to assure that new information regarding upcoming development has not changed the need for new lines from the previous studies. Also, if a new development, being commercial, industrial, or residential is proposing to be constructed, the additional water system improvements should be added to the computer model to determine the amount of domestic and fire flow available at the proposed project location. The fire flow information should only be furnished to a developer or owner with the understanding that the fire flow results are not guaranteed, and it is the responsibility of the owner and the fire protection designer to determine the facilities required in order to provide adequate fire protection for a particular project. 27 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 SECTION 7.0: Recommended System Improvements The City of Southlake has implemented mandatory water use restrictions and conservation measures, including public education. Development of additional conservation measures is recommended. The City has begun information gathering, on water reuse and additional supply alternatives. A second phase of study of these options is recommended. The City routinely monitors disinfection of water in the distribution system. Chloramine injection could be an option if this monitoring indicates disinfection problems in the future. Consideration will be given to property purchases when property becomes available in strategic locations for future water system improvements. Consideration should be given to additional emergency interconnections with adjacent water systems such as Trophy Club near T. W. King Road and Keller near Davis Boulevard. These emergency interconnects would likely require an amendment to the existing water supply agreement with the City of Fort Worth. Table 7.1 The following is a summary of the additional lines, pumps, and storage facilities, which will be required in the future based upon the current land use plans and growth trends of the City of Southlake. Any changes in those plans should result in a new analysis of the water system. Table 7.1 Capital Improvement Plan Projects Tier 1 (1-3 years) Project 8"12"16"20"Pumps / No. WL WL WL WL Valves Storage Description (FT) (FT) (FT) (FT) PRV Valves between the Upper / Lower pressure 1 4 - PRVs planes Along N. Pearson from Booster Station to 2 2390 Johnson Road Along SH 114 from Town Center to N. White 3 8580 Chapel Blvd. (Under Construction) 4 2@3474GPM 5.0 MG T.W. King Low Pressure Plane Pumps / Storage Impellar / 5 Motors Pearson - High Pressure Plane Pumps 8580 2390 Total Capital Improvement Plan Projects Tier 2 (3 4-6 years) 6 1.5 MG New 1.5 MG Elevated at T.W. King Site 28 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 7 1680 Along SH 114 from Reserve St to S. Carroll 8 4350 Along SH 114 from Briarwood Dr. to N. Carroll 9 3640 Along SH 114 from Highland to White Chapel 10 505 Loop System from IHOP to Bank St. Capital Improvement Plan Projects (Continued): Tier 2 (3 4-6 years) 11 425 Loop System from Bent Wood to Ownby Lane Loop System from Fox Glen Ct. to Ravenaux Ct to 12 1070 Countryside Ct. Along Lonesome Dove Ave. / Burney Lane/ Lake 13 2263 Dr. Loop System along Bob Jones Rd. to Walnut 14 1462 Brooks 15 4845 Along E Highland from N Carroll to N Kimball Ave Along Union Church and Pearson Ln. from FM 16 5995 1938 to FM 1709 Along N. Peytonville from Concho Ct. to 17 2150 Southridge Lakes Pkwy Along Shady Oaks Dr. from W. Highland to W. 18 5170 Dove Along Randol Mill Ave. from Morgan to Roanoke 19 2645 Dove Rd. 20 2105 Along N. Carroll and Dove 21 1162 Along E. Continental Ave. to Breezeway Add pumps at Caylor Tank or other water supply/reuse options 6787 24072 Total Capital Improvement Plan Projects Tier 3 (6 7 to 18 years) Project 12"16"20"Pumps / No. 8" WL WL WL WL Valves Storage Description (FT) (FT) (FT) (FT) Loop System from S. White Chapel and White 22 2280 Chapel Ct. to Silverwood Cir. 23 1225 Loop System from Lorch Meadow Ct to Harbor Ct. 24 5100 Loop System from N. White Chapel to Brooks Ct. Loop System from Austin Oaks Dr to south side 25 3690 SH 114 Along SH 114 from N. White Chapel to W. Dove 26 3590 Rd 27 3900 Along SH 114 from White Chapel to W Dove St. Loop System W. Dove Rd. along SH 114 and 28 3680 Sam School Rd 15975 17160 0 Total Non-Capital Improvement Plan Projects 2067 Loop System from Ashleigh Ln. to S. Carroll Ave. Loop System from Chapel Downs to Lake Wood 4337 Dr. and SH 114 3450 Loop System SH 114 to Boulder Dr. 4635 Loop System from E. Highland to SH 114 14489 0 Total 29 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 Table 7.2 Project Number Project Name Project Costs TIER 1 PROJECTS 1 PRV Valves between the Upper / Lower pressure plans $134,400 2 16" WL along N. Pearson from Booster Station to Johnson Road $420,793 3 20" WL along SH 114 from Towne Center to N. White Chapel Blvd. $1,402,598 4 T.W. King Low Pressure Plane Pumps / Storage $4,858,560 5 Pearson - High Pressure Plane Pumps $336,000 TIER 1 COSTS $7,152,351 TIER 2 PROJECTS 6 1.5 MG Elevated at TW King Site $2,929,920 7 12" WL along SH 114 from Reserve to S. Carroll $167,274 8 12" WL along SH 114 from Briarwood Drive to N. Carroll $480,077 9 12" WL along SH 114 from E. Highland St. to White Chapel Blvd. $362,584 10 8" WL loop system from IHOP to Bank St. $45,790 11 8" WL loop system from Bent Wood to Ownby Lane $56,549 8" WL loop system from Fox Glen Ct. to Ravenaux Ct. to Countryside 12 Ct.$94,389 13 8" WL along Lonesome Dove Ave. / Burney Lane / Lake Dr. $301,106 14 8" WL loop system along Bob Jones Rd. to Walnut Brooks $182,203 15 12" WL along E. Highland from N. Carroll to N. Kimball Ave. $696,750 12" WL along Union Church and Pearson Lane from FM 1938 to FM 16 1709 $862,129 12" WL along N. Peytonville From Concho Ct. to Southridge Lakes 17 Parkway $309,187 18 12" WL along Shady Oaks Drive From Highland to W. Dove $743,487 19 12" WL along Randol Mill Ave. From Morgan to Roanoke Dove Rd. $380,372 20 12" WL along N. Carroll and Dove $302,716 21 12" WL along E. Continental Ave to Breezeway $167,105 Additional Supply (Caylor and/or TRA) TBD TIER 2 COSTS $8,081,639 TIER 3 PROJECTS 8" WL loop system from S. White Chapel and White Chapel Ct. to 22 Silverwood Ct. $210,228 23 8" WL loop system from Lorch Meadow Ct. to Harbor Ct. $110,074 24 8" WL loop system from N. White Chapel to Brooks Ct. $691,085 25 8" WL loop system from Austin Oaks Dr. to south side SH 114 $569,426 30 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 TIER 3 PROJECTS (Continued): 26 20" WL along SH 114 from N. White Chapel to W. Dove Rd. $581,347 27 12" WL along SH 114 from White Chapel to Dove St. $383,040 8" WL loop system from W. Dove Rd. along SH 114 and Sam School 28 Rd. $321,243 TIER 3 COSTS $2,866,443 Total CIP Cost $18,100,433 NON-CAPITAL IMPROVEMENT PLAN PROJECTS 1A 8" WL loop system from Ashley Lane to S. Carroll Ave. $177,795 8" WL loop system from Chapel Downs to Lake Wood Dr. and SH 2A114 $551,803 3A 8" WL loop system from SH 114 to Boulder Dr. $474,970 4A 8" WL loop system from E. Highland to SH 114 $666,550 Total Non-CIP Cost $1,871,118 Total CIP and Non CIP Cost $19,971,551 31 CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 APPENDIX 32 Û¨¸·¾·¬ ïòï Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ Ý¿°·¬¿´ ׳°®±ª»³»²¬­ д¿² Ú´±©»® Ó±«²¼ ËÌ Û¨·­¬·²¹ Û´»ª¿¬»¼ ͬ±®¿¹» þ÷ Û¨·­¬·²¹ Ù®±«²¼ ͬ±®¿¹» ËÌ ïì Û¨·­¬·²¹ Ы³° ͬ¿¬·±² êùù F ŠЮ»­­«®» λ¼«½·²¹ Ê¿´ª» ÿá Ù®¿°»ª·²» Ô¿µ» ÞÑÞ ÖÑÒÛÍ ÎÜ Ì®±°¸§ Ý´«¾ ê Ю±°±­»¼ îðïðóîðïë ׳°®±ª»³»²¬­ Û¯«»­¬®·¿² Ü® ÌòÉò Û´»ª¿¬»¼ Ì¿²µ Ю±°±­»¼ îðïêóîðîð ׳°®±ª»³»²¬­ïó ïòë ÓÙ Û´»ª¿¬»¼ Ì¿²µ Í×ÔÊÛÎ ÍÐËÎ ÝÌ Û¨·­¬·²¹ É¿¬»®´·²»­ îì ÌòÉò Õ·²¹ Ы³° ͬ¿¬·±² Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® îó ëòð ÓÙÜ Ð«³°­ ïó ëòð ÓÙÜ Ì¿²µ ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ ï ó ëòð ÓÙ ÙÍÌ ß¼¼·¬·±²¿´ ï ó ëòð ÓÙ ÙÍÌ èùù ì ËÌ F Å Þ´«»­¬»³ Ü® îùù ÐÛÒ×ÒÍËÔß ÝÌ îí ïí ÉØ×ÌÛ É×ÒÙ ÝÌ êùù É»­¬´¿µ» ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ îè ÚÎÛÛÓßÒ ÝÌ ÑÙÑÔÔßÔß ÝÌ ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ Ó×ÜÜÔÛ Ü±ª» α¿¼ ïòë ÓÙ ÛÌ ÍÝØÑÑÔ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÛÓÛÎßÔÜ Ý×Î ËÌ ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» þ÷ ïèùù É ÜÑÊÛ ÎÜ îð êùù èùù ÎÑÞ×Ò ÔÒ ïç ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ îê ïè ÐØÛßÍßÒÌ ÔÒ ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ îé èùù ÔßÒÌßÒß ÔßÎÕÍÐËÎ ÝÌ ÝÌ ÚÑÈ ÙÔÛÒÒ ÎßÊÛÒßËÈ ïî ÝÌ í ÖßÝÕ Üò ÖÑØÒÍÑÒ ç ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÔßÒÜÍ ÛÒÜÝÌ ÝÌ ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ ÿá ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÝßÎÎÑÔÔ ï ×ÒÌÛÎÓÛÜ×ßÌÛ ïë ÍÝØÑÑÔ Îß×ÒÌÎÛÛ ÜÎ Õ»´´»® ÇÛßÎÙß×Ò ÝÌ ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÍÝØÑÑÔÍÝØÑÑÔ ïé ÉÑÑÜÞÎÑÑÕ ÔÒ ÌÛÒ ÞßÎ ÝÌ ï ÞÎßÆÑÍ ÜÎ è é ÿá ÔÔßÒÑ ÝÌ ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ïï Þ®»©»® α¿¼ ÛÌ êùù Ѫ»®º´±© Û´»ª¿¬·±² ã èêðù ËÌ ËÌ ÚÛÜÛÎßÔ ÉßÇ þ÷ ÓßÔÌÑÒ ÔÒ Þ·½»²¬»²²·¿´ п®µ ïòë ÓÙ ÛÌ í ËÌ ÓÛÍÏË×ÌÛ ÝÌ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù þ÷ ÞÔÊÜ îë ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ èùù ×Î×ÑÒ ÝÌ êùù êùù êùù êùù ØßÇ ÓÛßÜÑÉ ÇÑÎÕÍØ×ÎÛ ÙßÔÔßÒÌ ÝÌ ÝÌ êùù ï êùù êùù êùù ÉßÌÌÍ ÝÌ êùù ÝÌ ÿá ÖÑØÒÍÑÒ ÎÜÚòÓò ïéðç êùù êùù êùù ÚÔÑÎÛÒÝÛ ï êùù л¿®­±² α¿¼ ÞÐÍ ÍØÛÚÚ×ÛÔÜ êùù ÛÔÛÓò êùù ÝÌ ÍÝØÑÑÔ êùù ËÌ îðïë ÝßÎÎÑÔÔ Ó·®±² ïòë ÓÙ ÛÌ êùù þ÷ ÍÛÒ×ÑÎ Ø×ÙØ èùù íóíèðð ÙÐÓ Ð«³°­ Ѫ»®º´±© Û´»ª¿¬·±² ã èðïù ÍÝØÑÑÔ èùù î ÜÑÊÛÎ ÐÔ ÿá ÝÌÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ èùù ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÜÎ êùù ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ èùù ÛÊÛÎÉÑÑÜ ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ î ó ëòð ÓÙ ÙÍÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ ïð êùù ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ èùù ÝÌ ë ÌËËÌ F ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ Å êùù ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ êùù Ôß ÐßÔÑÓß ÝÌ ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌÍ×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ èùù îî ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ êùù ÝÌ Ý×Î ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ êùù Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ èùù îï êùù ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÝÌ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ êùù ÝÌ ïîùù ÐßÎÕ ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ïê ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ k ÝÌ ÝÌ êùù ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÝÎÛÛÕÉÑÑÜ ÝÌ êùù ðïôðððîôððð ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­Ä½·°ïò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ Û¨¸·¾·¬ ïòî Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ ÿø îðïî л¿µ ر«® ÿøÿø Ú´±©»® Ó±«²¼ Ю»­­«®» ݱ²¬±«®­ ¿²¼ Ú·®» Ú´±© ÿø ÿø Ú·®» º´±© ¿ª¿·´¿¾´» ä ïôéëð ÙÐÓ à îð °­· ÿø êùù Û¨·­¬·²¹ Û´»ª¿¬»¼ ͬ±®¿¹» ËÌ Ù®¿°»ª·²» Ô¿µ» þ÷ ÿø ÞÑÞ ÖÑÒÛÍ ÎÜ Ì®±°¸§ Ý´«¾ Û¨·­¬·²¹ Ù®±«²¼ ͬ±®¿¹» ÿø ÌË Û¯«»­¬®·¿² Ü® Û¨·­¬·²¹ Ы³° ͬ¿¬·±² F Å Í×ÔÊÛÎ ÍÐËÎ ÝÌ Û¨·­¬·²¹ É¿¬»®´·²»­ Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® ÌòÉò Õ·²¹ Ы³° ͬ¿¬·±² Ю»­­«®» ݱ²¬±«® äã íë ÐÍ×̱¬¿´ Ý¿°¿½·¬§ ã ïêòéð ÓÙÜ ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ Ú·®³ Ý¿°¿½·¬§ ã èòíë ÓÙÜ Ð®»­­«®» ݱ²¬±«® íê ó êð ÐÍ× ï ó ëòð ÓÙ ÙÍÌ Ð®»­­«®» ݱ²¬±«® êï ó èð ÐÍ× èùù ËÌ F ŠЮ»­­«®» ݱ²¬±«® èï ó ïðð ÐÍ× ÿ ø Ю»­­«®» ݱ²¬±«® ïðï ó ïëð ÐÍ× ÿø Þ´«»­¬»³ Ü®ÿø ÿøÿ ø ÿø îùù ÿø ÿø ÿ ø ÿøÿø ÿø ÿø ÐÛÒ×ÒÍËÔß ÿø ÝÌ ÿø ÿø ÿø ÿøÿø ÿøÿø ÉØ×ÌÛ É×ÒÙ ÝÌ ÿø ÿ êùù ø ÿø ÿø ÿø É»­¬´¿µ» ÿø ÿ ø ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ ÿ ø ÿø ÚÎÛÛÓßÒ ÝÌ ÿø ÑÙÑÔÔßÔß ÝÌ ÿø ÿø ÿø ÿø ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ ÿø Ó×ÜÜÔÛ Ü±ª» α¿¼ ïòë ÓÙ ÛÌ ÍÝØÑÑÔ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÛÓÛÎßÔÜ Ý×Î ËÌ ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» þ÷ ïèùù ÿ øÿ øÿ ø ÿ ø É ÜÑÊÛ ÎÜ ÿø ÿø ÿø êùù ÿøÿø ÿø èùù ÎÑÞ×Ò ÔÒ ÿ ø ÿø ÿø ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ ÿø ÿÿø ø ÿ øÿø ÿø ÿøÿø ÿø ÐØÛßÍßÒÌ ÔÒ ÿø ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ÿø ÿ ø ÿø ÿø ÿøÿø èùù ÿø ÿø ÔßÒÌßÒß ÿøÿø ÿ ÔßÎÕÍÐËÎ ø ÿø ÝÌ ÝÌ ÿ ø ÿ ø ÿø ÿø ÿ ø ÚÑÈ ÙÔÛÒÒ ÿø ÿø ÿø ÿø ÿø ÎßÊÛÒßËÈ ÝÌ ÿø ÿøÿÿ øø ÿ ÿøø ÿø ÿøÿÿø ø ÿø ÿø ÿø ÿø ÿø ÿø ÿø ÖßÝÕ Üò ÖÑØÒÍÑÒ ÿ ø ÿø ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÿø ÿø ÔßÒÜÍ ÛÒÜÝÌ ÿ ø ÝÌ ÿÿø ø ÿø ÿø ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÿøÿ ø ÝßÎÎÑÔÔ ÿø ÿÿø ø×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿ ø ÿø ÿø Îß×ÒÌÎÛÛ ÜÎ Õ»´´»®ÿø ÿø ÇÛßÎÙß×Ò ÝÌ ÿ øÿø ÿø ÿø ÿø ÿø ÿø ÿøÿ ø ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÿø ÍÝØÑÑÔÍÝØÑÑÔ ÿÿø ø ÿø ÿø ÿ øÿ ø ÉÑÑÜÞÎÑÑÕ ÔÒ ÿø ÿøÿø ÿø ÿ ø ÿø ÌÛÒ ÞßÎ ÿø ÝÌ ÿø ÿø ÿø ÿø ÞÎßÆÑÍ ÜÎ ÿø ÿø ÿøÿø ÿø ÿø ÿø ÿøÿø ÿø ÿø ÔÔßÒÑ ÝÌ ÿø ÿøÿø ÿø êùù ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÿø ÿø ÿ ÿø ø ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÿøÿø ÿø Þ®»©»® α¿¼ ÛÌ ÿøÿøÿø ÿø êùù ÿ ÿøø ÿ ø Ѫ»®º´±© Û´»ª¿¬·±² ã èêðù ÿøÿø ÿø ÿø ËÌ ËÌ ÿø ÿø ÿ ø ÿø ÚÛÜÛÎßÔ ÉßÇ ÿ ÿøø ÿ ø ÿø þ÷ ÿø ÿø ÓßÔÌÑÒ ÔÒ ÿøÿø Þ·½»²¬»²²·¿´ п®µ ïòë ÓÙ ÛÌ ËÌ ÓÛÍÏË×ÌÛ ÝÌ ÿ ø Ѫ»®º´±© Û´»ª¿¬·±² ã èðïù ÿøÿÿø øÿø þ÷ ÿ ÿÿøøÿø ø ÿø ÿø ÞÔÊÜ êùù ÿ ø ÿø ÿøÿøÿøÿ ÿøø ÿÿøÿ øø ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ ÿø ÿø ÿø èùù ×Î×ÑÒ ÿøÿ øÿø ÿø ÝÌ ÿøÿø êùù êùù ÿø êùù ÿøÿ ø ØßÇ ÓÛßÜÑÉ ÿø êùù ÿø ÇÑÎÕÍØ×ÎÛ ÿø ÙßÔÔßÒÌ ÝÌ ÝÌ ÿ ø ÿø êùù ÿø ÿø ÿø êùù êùù ÿ ø ÿø ÿø êùù ÿøÿø ÉßÌÌÍ ÝÌ êùù ÿø ÝÌ ÿøÿøÿÿøÿÿøÿøÿÿÿÿø øøøøøÿø ÖÑØÒÍÑÒ ÎÜ ÚòÓò ïéðç êùù л¿®­±² α¿¼ ÞÐÍ êùù êùù ÚÔÑÎÛÒÝÛ ÿø êùù Ë°°»®ÍØÛÚÚ×ÛÔÜ êùù ÛÔÛÓò êùù ÝÌ ÿø ̱¬¿´ Ý¿°¿½·¬§ ã çòðí ÓÙÜ ÍÝØÑÑÔ êùù ËÌ ÿø ÝßÎÎÑÔÔ Ú·®³ Ý¿°¿½·¬§ ã êòðî ÓÙÜ Ó·®±² ïòë ÓÙ ÛÌ êùù ÿø þ÷ ÍÛÒ×ÑÎ Ø×ÙØ èùù ÿ ø Ѫ»®º´±© Û´»ª¿¬·±² ã èðïù ÿø ÍÝØÑÑÔ èùù ÜÑÊÛÎ Ô±©»®ÐÔ ÿø ÿøÿÿø ÝÌÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ èùù ø ÿ øÿø ̱¬¿´ Ý¿°¿½·¬§ ã îéòîî ÓÙÜ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿø Ú·®³ Ý¿°¿½·¬§ ã îðòìï ÓÙÜ ÜÎ ÿÿÿ øøø ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ èùù ÛÊÛÎÉÑÑÜ ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ ÿø î ó ëòð ÓÙ ÙÍÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ êùù ÿø ÿø ÿ ø ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ èùù ÝÌ ÿøÿø ÿø ÿ ËÌËÌ ø F ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ Å ÿø êùù ÿø ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ êùù ÿøÿø Ôß ÐßÔÑÓß ÝÌ ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌ Í×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ èùù ÿø ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ êùù ÝÌ Ý×Î ÿø ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ êùù Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ êùù ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÝÌ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ êùù ÝÌ ïîùù ÐßÎÕ ÿø ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ ÿø k ÝÌ ÿ ø ÝÌ ÿø êùù ÿø ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÿø ÝÎÛÛÕÉÑÑÜ ÝÌ êùù ðïôðððîôððð ÿø ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­Äîðïðó°ò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ Û¨¸·¾·¬ ïòí Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ ÿ ø îðïë л¿µ ر«® ÿÿ øø Ú´±©»® Ó±«²¼ Ю»­­«®» ݱ²¬±«®­ ¿²¼ Ú·®» Ú´±©ÿø ÿø ÿ ø ÿ ø ÿø êùù ÿ ø Ú·®» º´±© ¿ª¿·´¿¾´» ä ïôéëð ÙÐÓ à îð °­· ÿø ÿø Û¨·­¬·²¹ Û´»ª¿¬»¼ ͬ±®¿¹» ËÌ ÿøÿø ÿ ø ÞÑÞ ÖÑÒÛÍ ÎÜ Ù®¿°»ª·²» Ô¿µ» ÿ ø þ÷ Ì®±°¸§ Ý´«¾ ÌòÉò Õ·²¹ Û´»ª¿¬»¼ Ì¿²µ Í·¬» ÿ ø ïóïòë ÓÙ Û´»ª¿¬»¼ Ì¿²µ Û¨·­¬·²¹ Ù®±«²¼ ͬ±®¿¹» Û¯«»­¬®·¿² Ü® ËÌ Í×ÔÊÛÎ ÍÐËÎ Û¨·­¬·²¹ Ы³° ͬ¿¬·±² ÝÌ F Å Û¨·­¬·²¹ É¿¬»®´·²»­ Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® ÌòÉò Õ·²¹ Ы³° ͬ¿¬·±² ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ Ð®»­­«®» ݱ²¬±«® äã íë ÐÍ×̱¬¿´ Ý¿°¿½·¬§ ã ïéòëï ÓÙÜ ï ó ëòð ÓÙ ÙÍÌ Ð®»­­«®» ݱ²¬±«® íê ó êð ÐÍ× ß¼¼·¬·±²¿´ ï ó ëòð ÓÙ ÙÍÌ èùù Ю»­­«®» ݱ²¬±«® êï ó èð ÐÍ× ËÌ F ŠЮ»­­«®» ݱ²¬±«® èï ó ïðð ÐÍ× ÿø ÿø Ю»­­«®» ݱ²¬±«® ïðï ó ïëð ÐÍ× Þ´«»­¬»³ Ü®ÿ ø ÿ øÿø ÿø îùù ÿø ÿø ÿø ÿÿ øø ÿø ÿ ø ÐÛÒ×ÒÍËÔß ÿø ÝÌ ÿ ø ÿø ÿ ø ÿÿ øø ÿÿ øø ÉØ×ÌÛ É×ÒÙ ÝÌ ÿ ø ÿø ÿ ø ÿ ø ÿ ø É»­¬´¿µ» ÿ ø ÿø ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ ÿø ÿ ø ÚÎÛÛÓßÒ ÝÌ ÿø ÑÙÑÔÔßÔß ÝÌ ÿø ÿø ÿ ø ÿø ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ ÿø Ó×ÜÜÔÛ Ü±ª» α¿¼ ïòë ÓÙ ÛÌ ÍÝØÑÑÔ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÛÓÛÎßÔÜ Ý×Î ËÌ ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» þ÷ ïèùù É ÜÑÊÛ ÎÜ ÿø ÎÑÞ×Ò ÔÒ ÿø ÿ ø ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ ÿ ø ÿ ÿøø ÿ øÿ øÿ ø ÿ ø ÿ ø ÐØÛßÍßÒÌ ÔÒ ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ÿø ÿø ÿ ø èùù ÿø ÔßÒÌßÒß ÿ ø ÔßÎÕÍÐËÎ ÿø ÿø ÝÌ ÝÌ ÿø ÿ ø ÚÑÈ ÙÔÛÒÒ ÿø ÿ ø ÎßÊÛÒßËÈ ÝÌ ÿøÿ ÿøø ÿøÿ ø ÖßÝÕ Üò ÖÑØÒÍÑÒ ÿ ø ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÿ ø ÔßÒÜÍ ÛÒÜÝÌ ÝÌ ÿø ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ S Þ ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÝßÎÎÑÔÔ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿø Îß×ÒÌÎÛÛ ÜÎ Õ»´´»® ÿ ÇÛßÎÙß×Ò ÝÌ ø ÿøÿø ÿ ø ÿ øÿø ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÿ ÍÝØÑÑÔÍÝØÑÑÔ ø ÿ ø ÿø ÉÑÑÜÞÎÑÑÕ ÔÒ ÿøÿ ø ÌÛÒ ÞßÎ ÿø ÝÌ ÿø ÿ ø ÞÎßÆÑÍ ÜÎ êùù ÿø ÿ ø ÿø S Þ ÔÔßÒÑ ÝÌ ÿø ÿ ø ÿ ø êùù ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÿø ÿø ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÿ ø Þ®»©»® α¿¼ ÛÌ ÿø êùù Ѫ»®º´±© Û´»ª¿¬·±² ã èêðù ÿø ÿø ËÌ èùù ËÌ ÿ ø ÿø ÿ ÚÛÜÛÎßÔ ÉßÇ øÿø èùù þ÷ ÓßÔÌÑÒ ÔÒ Þ·½»²¬»²²·¿´ п®µ ïòë ÓÙ ÛÌ ËÌ ÓÛÍÏË×ÌÛ ÝÌ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù þ÷ ÿø ÞÔÊÜ êùù ÿ ø ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ èùù ×Î×ÑÒ ÝÌ ÿ ø êùù ÿ êùù ø êùù ØßÇ ÓÛßÜÑÉ ÿÿø ÇÑÎÕÍØ×ÎÛ ø ÙßÔÔßÒÌ ÝÌ ÝÌ êùù ÿø ÿø êùùêùùêùù ÿ ø êùù èùù ÿ ø ÉßÌÌÍ ÝÌ êùù ÝÌ S Þ ÖÑØÒÍÑÒ ÎÜ ÚòÓò ïéðç êùù êùù êùù ÚÔÑÎÛÒÝÛ êùù л¿®­±² α¿¼ ÞÐÍ ÍØÛÚÚ×ÛÔÜ êùù ÛÔÛÓò êùù ÝÌ ÍÝØÑÑÔ êùù ÌË ÝßÎÎÑÔÔ Ë°°»® Ó·®±² ïòë ÓÙ ÛÌ êùù þ÷ ÍÛÒ×ÑÎ Ø×ÙØ èùù ̱¬¿´ Ý¿°¿½·¬§ ã èòëë ÓÙÜ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÍÝØÑÑÔ èùù ÜÑÊÛÎ ÐÔ Þ S ÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ èùù ÝÌ Ô±©»® ÿ ø ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿø êùù ̱¬¿´ Ý¿°¿½·¬§ ã ïçòçð ÓÙÜ ÜÎ êùù ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ èùù ÛÊÛÎÉÑÑÜ ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ ÿ ø î ó ëòð ÓÙ ÙÍÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ ÿ ø ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ èùù ÝÌ ÿ ø ËÌ ÿø F ËÌ ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ Å êùù êùù ÿø ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ ÿÿø Ôß ÐßÔÑÓß ÝÌ ø ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌÍ×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ èùù ÿ ø ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ êùù ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ êùù ÝÌ Ý×Î ÿ ø ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ êùù Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ êùù ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÝÌÛÔÛÓÛÒÌßÎÇ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ êùù ÝÌ ïîùù ÐßÎÕ ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ ÿ ø k ÝÌ ÿø ÝÌ êùù ÿ ø ÿ ø ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÿ ø ÝÎÛÛÕÉÑÑÜ ÝÌ êùù ÿ ø ÿø ðïôðððîôððð ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­Äîðïëó°ò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ Û¨¸·¾·¬ ïòì Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ ÿ ø îðîð л¿µ ر«® ÿÿ øø Ú´±©»® Ó±«²¼ Ю»­­«®» ݱ²¬±«®­ ¿²¼ Ú·®» Ú´±© ÿø ÿ ø ÿø Ú·®» º´±© ¿ª¿·´¿¾´» ä ïôéëð ÙÐÓ à îð °­· ÿ ø êùù ÿ ø ÌË Û¨·­¬·²¹ Û´»ª¿¬»¼ ͬ±®¿¹» þ÷ ÿ Ù®¿°»ª·²» Ô¿µ» ø ÿ ø ÞÑÞ ÖÑÒÛÍ ÎÜ ÿ ø Û¨·­¬·²¹ Ù®±«²¼ ͬ±®¿¹»Ì®±°¸§ Ý´«¾ ÌË ÿ ø Û¯«»­¬®·¿² Ü® Û¨·­¬·²¹ Ы³° ͬ¿¬·±² ÌòÉò Õ·²¹ Û´»ª¿¬»¼ Ì¿²µ Í·¬» F Å Í×ÔÊÛÎ ÍÐËÎ ïóïòë ÓÙ Û´»ª¿¬»¼ Ì¿²µ ÝÌ Û¨·­¬·²¹ É¿¬»®´·²»­ Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® Ю»­­«®» ݱ²¬±«® äã íë ÐÍ× ÌòÉò Õ·²¹ Ы³° ͬ¿¬·±² ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ Ì±¬¿´ Ý¿°¿½·¬§ ã ïéòëï ÓÙÜ Ð®»­­«®» ݱ²¬±«® íê ó êð ÐÍ× ï ó ëòð ÓÙ ÙÍÌ ß¼¼·¬·±²¿´ ï ó ëòð ÓÙ ÙÍÌ Ð®»­­«®» ݱ²¬±«® êï ó èð ÐÍ× èùù ËÌ F ŠЮ»­­«®» ݱ²¬±«® èï ó ïðð ÐÍ× ÿø Ю»­­«®» ݱ²¬±«® ïðï ó ïëð ÐÍ× ÿø Þ´«»­¬»³ Ü®ÿ ø ÿ øÿø ÿø îùù ÿø ÿø ÿø ÿ ø ÐÛÒ×ÒÍËÔß ÿø ÝÌ ÿ ø ÿø ÿ ø ÿ ø ÿ ø ÉØ×ÌÛ É×ÒÙ ÝÌ êùù É»­¬´¿µ» ÿø ÿø ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ ÿø ÿ ø ÚÎÛÛÓßÒ ÝÌ ÿø ÑÙÑÔÔßÔß ÝÌ ÿø ÿø ÿø ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ ÿø Ó×ÜÜÔÛ Ü±ª» α¿¼ ïòë ÓÙ ÛÌ ÍÝØÑÑÔ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÛÓÛÎßÔÜ Ý×Î ËÌ ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» þ÷ ïèùù É ÜÑÊÛ ÎÜ ÿ ø êùù èùù ÎÑÞ×Ò ÔÒ ÿø ÿø ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ ÿ ø ÿ ÿøø ÿøÿ øÿ ø ÿ ø ÿ ø ÐØÛßÍßÒÌ ÔÒ ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ÿ ø ÿø èùù ÔßÒÌßÒß ÿ ø ÔßÎÕÍÐËÎ ÿø ÿø ÝÌ ÝÌ ÿ ø ÚÑÈ ÙÔÛÒÒ ÿø ÿ ø ÎßÊÛÒßËÈ ÝÌ ÿøÿ ÿøø ÿøÿ ø ÖßÝÕ Üò ÖÑØÒÍÑÒ ÿø ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÿ ø ÔßÒÜÍ ÛÒÜÝÌ ÝÌ ÿ ø ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ S Þ ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÝßÎÎÑÔÔ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿø Îß×ÒÌÎÛÛ ÜÎ Õ»´´»® ÿ ÇÛßÎÙß×Ò ÝÌ ø ÿøÿø ÿ ø ÿ øÿø ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÿ ÍÝØÑÑÔÍÝØÑÑÔ ø ÿ ø ÿø ÉÑÑÜÞÎÑÑÕ ÔÒ ÿøÿ ø ÌÛÒ ÞßÎ ÿø ÝÌ ÿ ø ÿ ø ÞÎßÆÑÍ ÜÎ ÿø ÿ ø ÿ ø S Þ ÔÔßÒÑ ÝÌ ÿ øÿ ø ÿ ø êùù ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÿ ø ÿø ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÿ ø Þ®»©»® α¿¼ ÛÌ ÿø êùù Ѫ»®º´±© Û´»ª¿¬·±² ã èêðù ÿø ÿø ËÌ ËÌ ÿ ø ÿø ÿ ÚÛÜÛÎßÔ ÉßÇ øÿø þ÷ ÓßÔÌÑÒ ÔÒ Þ·½»²¬»²²·¿´ п®µ ïòë ÓÙ ÛÌ ËÌ ÓÛÍÏË×ÌÛ ÝÌ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù þ÷ ÿ ø ÞÔÊÜ êùù ÿ ø ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ èùù ×Î×ÑÒ ÝÌ ÿ ø êùù êùù ÿ êùù ø ØßÇ ÓÛßÜÑÉ ÿ êùù ÿø ø ÇÑÎÕÍØ×ÎÛ ÙßÔÔßÒÌ ÝÌ ÝÌ êùù ÿø ÿø êùù êùù ÿ ø êùù ÿ ø ÉßÌÌÍ ÝÌ êùù ÝÌ S Þ ÖÑØÒÍÑÒ ÎÜ ÚòÓò ïéðç êùù êùù êùù ÚÔÑÎÛÒÝÛ êùù л¿®­±² α¿¼ ÞÐÍ ÍØÛÚÚ×ÛÔÜ êùù ÛÔÛÓò êùù ÝÌ ÍÝØÑÑÔ êùù ËÌ ÝßÎÎÑÔÔ Ë°°»® Ó·®±² ïòë ÓÙ ÛÌ êùù þ÷ ÍÛÒ×ÑÎ Ø×ÙØ èùù ̱¬¿´ Ý¿°¿½·¬§ ã èòëë ÓÙÜ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÍÝØÑÑÔ èùù ÜÑÊÛÎ ÐÔ Þ S ÝÌÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ èùù Ô±©»® ÿ ø ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿ ø ̱¬¿´ Ý¿°¿½·¬§ ã ïçòçð ÓÙÜ ÜÎ ÿø êùù ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ èùù ÛÊÛÎÉÑÑÜ ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ ÿ ø î ó ëòð ÓÙ ÙÍÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ êùù ÿø ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ èùù ÝÌ ÿ ø ËÌËÌ ÿø F ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ Å êùù ÿø ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ êùù ÿÿø Ôß ÐßÔÑÓß ÝÌ ø ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌ Í×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ èùù ÿ ø ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ êùù ÝÌ Ý×Î ÿ ø ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ êùù Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ êùù ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÝÌ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ êùù ÝÌ ïîùù ÐßÎÕ ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ ÿø k ÝÌ ÿø ÝÌ êùù ÿø ÿ ø ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÿ ø ÝÎÛÛÕÉÑÑÜ ÝÌ êùù ÿ ø ðïôðððîôððð ÿø ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­Äîðîðó°ò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ Û¨¸·¾·¬ ïòë Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ ÿ ø Þ«·´¼±«¬ л¿µ ر«® ÿÿ øø Ú´±©»® Ó±«²¼ Ю»­­«®» ݱ²¬±«®­ ¿²¼ Ú·®» Ú´±© ÿø ÿ ø ÿø Ú·®» º´±© ¿ª¿·´¿¾´» ä ïôéëð ÙÐÓ à îð °­·êùù ÿøÿ ø Û¨·­¬·²¹ Û´»ª¿¬»¼ ͬ±®¿¹» ÌË ÿ Ù®¿°»ª·²» Ô¿µ» ø þ÷ÿ øÿ ø ÞÑÞ ÖÑÒÛÍ ÎÜ ÿ ø Ì®±°¸§ Ý´«¾ ÿ ø Û¨·­¬·²¹ Ù®±«²¼ ͬ±®¿¹» ÌË Û¯«»­¬®·¿² Ü® ÌòÉò Õ·²¹ Û´»ª¿¬»¼ Ì¿²µ ïòë Û´»ª¿¬»¼ ͬ±®¿¹» Ì¿²µ Û¨·­¬·²¹ Ы³° ͬ¿¬·±² F Å Í×ÔÊÛÎ ÍÐËÎ ÝÌ Û¨·­¬·²¹ É¿¬»®´·²»­ Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® ÌòÉò Õ·²¹ Ы³° ͬ¿¬·±² ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ Ð®»­­«®» ݱ²¬±«® äã íë ÐÍ× Ì±¬¿´ Ý¿°¿½·¬§ ã ïéòëï ÓÙÜ Ð®»­­«®» ݱ²¬±«® íê ó êð ÐÍ× ï ó ëòð ÓÙ ÙÍÌ ß¼¼·¬·±²¿´ ï ó ëòð ÓÙ ÙÍÌ Ð®»­­«®» ݱ²¬±«® êï ó èð ÐÍ×èùù ËÌ F ŠЮ»­­«®» ݱ²¬±«® èï ó ïðð ÐÍ× ÿø ÿø Ю»­­«®» ݱ²¬±«® ïðï ó ïëð ÐÍ× Þ´«»­¬»³ Ü®ÿ ø ÿ øÿø ÿø îùù ÿø ÿø ÿø ÿÿ øø ÿø ÿ ø ÐÛÒ×ÒÍËÔß ÿø ÝÌ ÿ ø ÿø ÿ ø ÿÿ øø ÿ ø ÉØ×ÌÛ É×ÒÙ ÝÌ êùù É»­¬´¿µ» ÿø ÿø ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ ÿø ÿ ø ÚÎÛÛÓßÒ ÝÌ ÿø ÑÙÑÔÔßÔß ÝÌ ÿø ÿø ÿø ÿ ø ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ ÿø Ó×ÜÜÔÛ Ü±ª» α¿¼ ïòë ÓÙ ÛÌ ÍÝØÑÑÔ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÛÓÛÎßÔÜ Ý×Î ËÌ ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» þ÷ ïèùù É ÜÑÊÛ ÎÜ ÿ ø êùù èùù ÎÑÞ×Ò ÔÒ ÿø ÿø ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ ÿ ø ÿ ÿøø ÿøÿ øÿ ø ÿ ø ÿ ø ÐØÛßÍßÒÌ ÔÒ ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ÿ ø ÿø ÿ ø èùù ÿø ÔßÒÌßÒß ÿ ø ÔßÎÕÍÐËÎ ÿø ÿø ÝÌ ÝÌ ÿ ø ÿø ÿ ø ÚÑÈ ÙÔÛÒÒ ÿø ÿ ø ÎßÊÛÒßËÈ ÝÌ ÿøÿ ÿøø ÿøÿ ø ÖßÝÕ Üò ÖÑØÒÍÑÒ ÿø ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÿ ø ÔßÒÜÍ ÛÒÜÝÌ ÝÌ ÿ ø ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ S Þ ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÝßÎÎÑÔÔ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿø Îß×ÒÌÎÛÛ ÜÎ Õ»´´»® ÿ ÇÛßÎÙß×Ò ÝÌ ø ÿøÿø ÿ ø ÿ øÿø ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÿ ÍÝØÑÑÔÍÝØÑÑÔ ø ÿ ø ÿø ÉÑÑÜÞÎÑÑÕ ÔÒ ÿøÿ ø ÌÛÒ ÞßÎ ÿø ÝÌ ÿ ø ÿ ø ÞÎßÆÑÍ ÜÎ ÿø ÿ ø ÿ ø S Þ ÔÔßÒÑ ÝÌ ÿ øÿ ø ÿ ø êùù ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÿ ø ÿø ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÿ ø Þ®»©»® α¿¼ ÛÌ ÿø êùù Ѫ»®º´±© Û´»ª¿¬·±² ã èêðù ÿø ÿø ËÌ ËÌ ÿ ø ÿø ÿ ÚÛÜÛÎßÔ ÉßÇ øÿø þ÷ ÓßÔÌÑÒ ÔÒ Þ·½»²¬»²²·¿´ п®µ ïòë ÓÙ ÛÌ ËÌ ÓÛÍÏË×ÌÛ ÝÌ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù þ÷ ÿ ø ÞÔÊÜ êùù ÿ ø ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ èùù ×Î×ÑÒ ÝÌ ÿ ø êùù êùù ÿ êùù ø ØßÇ ÓÛßÜÑÉ ÿ êùù ÿø ø ÇÑÎÕÍØ×ÎÛ ÙßÔÔßÒÌ ÝÌ ÝÌ êùù ÿø ÿø êùù êùù ÿ ø êùù ÿ ø ÉßÌÌÍ ÝÌ êùù ÝÌ S Þ ÖÑØÒÍÑÒ ÎÜ ÚòÓò ïéðç êë êùù êùù êùù ÚÔÑÎÛÒÝÛ êùù л¿®­±² α¿¼ ÞÐÍ ÍØÛÚÚ×ÛÔÜ êùù ÛÔÛÓò êùù ÝÌ ÍÝØÑÑÔ êùù ËÌ ÝßÎÎÑÔÔ Ë°°»® Ó·®±² ïòë ÓÙ ÛÌ êùù þ÷ ÍÛÒ×ÑÎ Ø×ÙØ èùù ̱¬¿´ Ý¿°¿½·¬§ ã èòëë ÓÙÜ Ñª»®º´±© Û´»ª¿¬·±² ã èðïù ÍÝØÑÑÔ èùù ÜÑÊÛÎ ÐÔ Þ S ÝÌÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ èùù Ô±©»® ÿ ø ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÿ ø ̱¬¿´ Ý¿°¿½·¬§ ã ïçòçð ÓÙÜ ÜÎ ÿø êùù ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ èùù ÛÊÛÎÉÑÑÜ ÿ ø ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ ÿ ø î ó ëòð ÓÙ ÙÍÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ êùù ÿø ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ èùù ÝÌ ÿ ø ËÌËÌ ÿø F ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ Å êùù ÿø ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ êùù ÿÿø Ôß ÐßÔÑÓß ÝÌ ø ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌ Í×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ èùù ÿ ø ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ êùù ÝÌ Ý×Î ÿ ø ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ êùù Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ êùù ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÝÌ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ êùù ÝÌ ïîùù ÐßÎÕ ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ k ÿø ÝÌ ÿø ÝÌ êùù ÿø ÿ ø ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÿ ø ÝÎÛÛÕÉÑÑÜ ÝÌ êùù ÿ ø ðïôðððîôððð ÿø ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­ÄÞÑó°ò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ Û¨¸·¾·¬ ïòê Ý·¬§ ±º ͱ«¬¸´¿µ» É¿¬»® ͧ­¬»³ ß²¿´§­·­ Ë´¬·³¿¬» ͧ­¬»³ Ó¿° Ú´±©»® Ó±«²¼ îþ É¿¬»® Ô·²» êþ É¿¬»® Ô·²» èþ É¿¬»® Ô·²» Ù®¿°»ª·²» Ô¿µ» ïîþ É¿¬»® Ô·²» ÞÑÞ ÖÑÒÛÍ ÎÜ Ì®±°¸§ Ý´«¾ Û¯«»­¬®·¿² Ü® îðþ É¿¬»® Ô·²» Í×ÔÊÛÎ ÍÐËÎ ÝÌ îìþ É¿¬»® Ô·²» Ë°°»® Ю»­­«®» д¿²» пª·´·±² Ü® ÝÔßÎ×ÜÛÒ ÎßÒÝØ ÎÜ Þ´«»­¬»³ Ü® ÐÛÒ×ÒÍËÔß ÝÌ ÉØ×ÌÛ É×ÒÙ ÝÌ É»­¬´¿µ» ÙÎßÊÛÔ Ý×Î ÍÉÛÛÌ ÍÌ ÚÎÛÛÓßÒ ÝÌ ÑÙÑÔÔßÔß ÝÌ ÌßÇÔÑÎ ÍÌ ÝßÎÎÑÔÔ Ó×ÜÜÔÛ ÍÝØÑÑÔ ÛÓÛÎßÔÜ Ý×Î ÛßÍÌ ÜÑÊÛ ÎÜ Ù®¿°»ª·²» É ÜÑÊÛ ÎÜ ÎÑÞ×Ò ÔÒ ÓÑÝÕ×ÒÙÞ×ÎÜ ÔÒ ÐØÛßÍßÒÌ ÔÒ ÜÛÔ ÓßÎ ÜÎ ÍßÜÜÔÛÝÎÛÛÕ ÜÎ øÐÊÌ÷ ÔßÒÌßÒß ÔßÎÕÍÐËÎ ÝÌ ÝÌ ÚÑÈ ÙÔÛÒÒ ÎßÊÛÒßËÈ ÝÌ ÖßÝÕ Üò ÖÑØÒÍÑÒ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ ÔßÒÜÍ ÛÒÜÝÌ ÝÌ ÛßÍÌ Ø×ÙØÔßÒÜ ÍÌ ÉÛÍÌ Ø×ÙØÔßÒÜ ÍÌ ÝßÎÎÑÔÔ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ Îß×ÒÌÎÛÛ ÜÎ Õ»´´»® ÇÛßÎÙß×Ò ÝÌ ÜËÎØßÓ ÝßÎÎÑÔÔ ÍßÒ ßËÙËÍÌ×ÒÛ ÛÔÛÓÛÒÌßÎÇØ×ÙØ ÍÝØÑÑÔÍÝØÑÑÔ ÉÑÑÜÞÎÑÑÕ ÔÒ ÌÛÒ ÞßÎ ÝÌ ÞÎßÆÑÍ ÜÎ ÔÔßÒÑ ÝÌ ÎÛÜÉ×ÒÙ ÜÎ ÙÔÛÒ ÝÑÊÛ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÔÑÊÛ ØÛÒÎÇ ÝÌ ÚÛÜÛÎßÔ ÉßÇ ÓßÔÌÑÒ ÔÒ ÓÛÍÏË×ÌÛ ÝÌ ÞÔÊÜ ÝØ×ÍËÓ ÌÎÔ ÕÒ×ÙØÌ ÝÌ ×Î×ÑÒ ÝÌ ØßÇ ÓÛßÜÑÉ ÇÑÎÕÍØ×ÎÛ ÙßÔÔßÒÌ ÝÌ ÝÌ ÉßÌÌÍ ÝÌ ÝÌ ÖÑØÒÍÑÒ ÎÜ ÚòÓò ïéðç ÚÔÑÎÛÒÝÛ ÍØÛÚÚ×ÛÔÜ ÛÔÛÓò ÝÌ ÍÝØÑÑÔ ÝßÎÎÑÔÔ ÍÛÒ×ÑÎ Ø×ÙØ ÍÝØÑÑÔ ÜÑÊÛÎ ÐÔ ÝÌÝÔÛÞËÎÒÛ ÛËÞßÒÕÍ ×ÒÌÛÎÓÛÜ×ßÌÛ ÍÝØÑÑÔ ÜÎ ÙÎßÇ ÔÒ ÝÔßÇÌÑÒ ÝÌ ÛÊÛÎÉÑÑÜ ÙÛÑÎÙÛ ÜßÉÍÑÒ ÝÌ Ó×ÜÜÔÛ ÍÝØÑÑÔ ÖÑÎÜßÒ ÜÎ ÐßÎÕ ÐÔßÝÛ ÝÌ ÞÑßÎÜÉßÔÕÐßÎÕ ÐÔßÝÛ ÝÌ ÌØÑÓßÍ ÖßÝÕÍÑÒÓÛÎÔÑÌ ÜÎ ÝÌÝßÎÎ×ßÙÛ ÉßÇ ÍÏËßÎÛ ÝÌ ÜßÎÌÓÑËÌØ ÜÎÉ×ÒÜÓÛÎÛ ÝÌ Ý×ÍÜ Ôß ÐßÔÑÓß ÝÌ ÊÛÎÍß×ÔÔÛÍ ×ÎÑÒÝÔßÜ ÝÌ Í×ÔÊÛÎÉÑÑÜ Ý×Î ÜÎ ÍØÑÎÛÝÎÛÍÌ ÝÌ ÚßÝ×Ô×ÌÇ ÝÌ ÝÌ ÝÌ ÐÎ×ÒÝÛÌÑÒ ÊÛÎÜËÒ Ê×ÒÑ ÞÔßÒÝ ÐßÎÕ ÜÎ ÝÌ Ý×Î ÓÛÎÎ×ÓßÝ ÝÌ ÓÛßÜÑÉ ÝÌÉßÇ Ê×ÒÑ ÎÑÍÍÑ ÞßÇÑË Ê×ÍÌß ÝÌ ÍÌÑÒÛÉÑÑÜ ÝÌ ÑÔÜ ËÒ×ÑÒÝØßÎÜÑÒÒßÇ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÝÌ ÝÌ ÍÝØÑÑÔ ÌÛÎÍÐÎËÝÛ ÝÌ ÝÌ ÐßÎÕ ËÒ×ÑÒ ÝØËÎÝØ ÛßÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÉÛÍÌ ÝÑÒÌ×ÒÛÒÌßÔ ÞÔÊÜ ÓÑÒÌÙÑÓÛÎÇ Ê×ÝÕÍÞËÎÙÓÑÒÌÙÑÓÛÎÇ ÔÒ ÝÌ ÞßÎÔÑÉ ÝÌ ÝßÎÎÑÔÔÞÛÒÜ ÝÌ ÛÔÛÓÛÒÌßÎÇ ÍÝØÑÑÔ Õ×ÎÕÝßÔÜÇ ÒÛÔÍÑÒÝÌ ÝÌ k ÝÌ ÝÌ ÞÛÒÌÔÛÇ ÝÎÑÍÍ×ÒÙ ÝÎÛÛÕÉÑÑÜ ÝÌ ðïôðððîôððð ݱ´´»§ª·´´» ͽ¿´» ·² Ú»»¬ °æÄ­±«¬¸´¿µ»ÄïçíìĽ·ª·´Ä»¨¸·¾·¬­Ä«´¬·³¿¬»ïò³¨¼ Ю»°¿®»¼æ Ó¿®½¸ô îðïî Ò±®¬¸ η½¸´¿²¼ Ø·´´­ CITY OF SOUTHLAKE - WATER SYSTEM ANALYSIS 2012 APPENDIX 32 SPIN MEETING REPORT CASE NO. Ordinance No. 1032 PROJECT NAME: Water System Master Plan SPIN DISTRICT: Citywide MEETING DATE: April 23, 2012; 6:00 PM MEETING LOCATION: 1400 Main Street, Southlake, TX Training Rooms 3A 3B TOTAL ATTENDANCE: Fourteen (14) SPIN REPRESENTATIVE(S) PRESENT: None CONSULTANTS PRESENT: Derek Cheatham & Nelson Lucius; Neel Schaffer, Cheatham & Associates STAFF PRESENT: Bob Price, Director of Public Works; Ken Baker, Director of Planning & Development Services; Gordon Mayer, Deputy Director of Public Works and City Engineer; Steve Anderson, Civil Engineer; and, Lorrie Fletcher, Planner I STAFF CONTACT: Lorrie Fletcher, Planner I, (817)748-8069; lfletcher@ci.southlake.tx.us EXECUTIVE SUMMARY Details The Southlake 2030 Water, Waste Water & Storm Water Committee has finished its work on the water element of this plan and has made the recommendation that City Council consider approval of the three elements (1: water; 2: waste water and 3: storm water) separately. As such the water element has been completed and is ready for formal approval. Adopting the plan in FY 2012 provides staff and City Council the ability to use the plan as a guide for funding recommendations for FY 2013 and move forward next fiscal year on the development of the water conservation plan. The following is a summary of recommendations presented at SPIN: Pressure reducing valves Connection from Pearson Pump Station to Johnson Road T.W. King pump station upgrades Pearson Rd. pump station upgrades Tier II and Tier III projects QUESTIONS / CONCERNS Do the green lines just serve Southlake? No, through cooperation agreements, it is shared with Keller and Westlake Î ition on private wells? Support or resistance? Currently, private wells are allowed. Deep wells can be expensive. We have seen Î the aquifer get depleted which has caused some issues. Ground water is not currently regulated for irrigation purposes. The County has registration requirements in place for drilling wells. No restrictions in Southlake at this time. Will Southlake consider promotions or tax incentives? Not currently water re-use may become a viable source for irrigation. Î If your pressure is low, what would that mean? Sometimes pressure is lowered by extended use of the elevated tanks; land Î elevation changes can also cause pressure changes. We can test for low pressure problems. How is it that we went into water restrictions before Keller if we share the same line? Î such a short period of time. This caused the elevated tanks to empty faster. The When will that project be completed? We anticipate completion by February 2013. Î Southlake sits on Lake Grapevine; what significance does that have? None we do not have rights to Lake Grapevine. University & Highland Park Î W Yes, we have 90 days to comply with any water conservation Ft. Worth enacts. Î Is enforcement a part of this conservation plan? What we are hoping is that residents will modify their behavior. The intent is not Î Smart Use. What about incentive plans? We have discussed a tier grade structure use more, pay more. Î Has the city considered balance between supply and growth? Yes, Î may not happen for 20 years. We do not anticipate a short-fall that warrants limiting development. The Land Use Plan dictates maximum residential and commercial. We have a good idea of what we will have at build-out. The Land Use Plan is completed first and dictates all other comprehensive plans. I remember talk a while ago about a large supply line at the city northern border.. is that still happening? Not that Im aware of possibly the one coming down Hwy 377. Westlake at one Î time discussed a plan. Its been a while.. about 20 years ago. Î SPIN Meeting Reports are general observations of SPIN Meetings by City staff and SPIN Representatives. The report is neither verbatim nor official meeting minutes; rather it serves to inform elected and appointed officials, City staff, and the public of the issues and questions raised by residents and the general responses made. Responses as summarized in this report should not be taken as guarantees by the applicant. Interested parties are strongly encouraged to follow the case through the Planning and Zoning Commission and final action by City Council.