Loading...
Item 6C Department of Planning & Development Services S T A F F R E P O R T March 27, 2012 CASE NO: ZA12-003 PROJECT: Site Plan for Lot 3R2R, Block 1, Timarron Golf Course EXECUTIVE SUMMARY: CCI Architects, on behalf of the Timarron Golf Club, is requesting approval of a Site Plan for the addition of 1,896 square feet of terraced dining area to the existing country club facility on Lot 3R2R, Block 1, Timarron Golf Course, being approximately 8.5 acres located at 1400 Byron Nelson Parkway. SPIN #9 DETAILS: CCI Architects is requesting approval of a Site Plan for the addition of 1,896 square feet to the existing country club building facility. The majority of this floor area will be to the main floor terrace dining area consisting of approximately 1,503 square feet. The lower level will add approximately 393 square feet of storage area under the new terraced dining area. All portions of the addition will match the existing materials on the building consisting of natural stone, stucco, wood fascia and synthetic slate roof shingles. These additions are also a part of some interior alterations the country club is doing in the existing building to the lounge, ballroom and restrooms. ACTION NEEDED: 1) Conduct Public Hearing 2) Consider Site Plan Approval Request ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information – Link to PowerPoint Presentation (D) Site Plan Review Summary No. 2, dated March 16, 2012 (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses (G) Full Size Plans (for Commission and Council Members Only) STAFF CONTACT: Dennis Killough (817) 748-8072 Daniel Cortez (817) 748-8070 Case No. ZA12-003 BACKGROUND INFORMATION OWNER: Timarron Golf Club APPLICANT: CCI Architects PROPERTY SITUATION: 1400 Byron Nelson Pkwy. LEGAL DESCRIPTION: Lot 3R2R, Block 1, Timarron Golf Course LAND USE CATEGORY: Medium Density Residential CURRENT ZONING: “R-PUD” Residential Planned Unit Development Zoning District SOUTHLAKE 2030 PLAN: Southeast Sector Plan Under the Southlake 2030 Southeast Sector Plan, a component of the Consolidated Land Use Plan, recommends for the country club to be changed from Mixed Use to Medium Density Residential so any undesired uses for the property would not be permitted. Consolidated Future Land Use Plan The approved Consolidated Future Land Use Plan changed the designation of the country club from Mixed Use to Medium Density Residential based on the recommendation of the Southeast Sector Plan. CITIZEN INPUT: A SPIN meeting was held on February 27, 2012 at Town Hall. The SPIN report for this meeting is under Attachment “C” of this staff report. PLANNING & ZONING COMMISSION: March 22, 2012; The Planning and Zoning Commission recommended approval (6-0) subject to the findings in the Staff Report dated March 16, 2012. STAFF COMMENTS: Attached isSite Plan Review Summary No. 2, dated March 16, 2012. N:\Community Development\MEMO\2012 Cases\003 - SP - Timarron Country Club\Staff Report Case No. Attachment A ZA12-003 Page 1 Case No. Attachment B ZA12-003 Page 1 Plans and Support Information Area of addition Case No. Attachment C ZA12-003 Page 1 Case No. Attachment C ZA12-003 Page 2 Elevations Case No. Attachment C ZA12-003 Page 3 Case No. Attachment C ZA12-003 Page 4 Case No. Attachment C ZA12-003 Page 5 SITE PLAN REVIEW SUMMARY Case No.: ZA12-003 Review No.: Two Date of Review: 03/16/12 Site PlanTimarron Country Club Project Name: – APPLICANT: Timarron Country Club ARCHITECT: CCI Travis Arbogast Patrick Hazard 1400 Byron Nelson Pkwy 100 Decker Dr., Suite 140 Southlake, TX 76092 Irving, TX 75062 Phone: 817-481-7529 Phone: 971-253-3583 Fax: 817-421-8485 Fax: 972-259-9664 CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 01/03/12 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DANIEL CORTEZ AT (817) 748-8070. Informational Planning Department Comments 1. The use of synthetic products (e.g., EIFS – exterior insulation and finish systems, Hardy plank, or other materials of similar characteristics) shall not be considered a masonry material. 2. Stucco or plaster shall only be allowed when applied using a 3-step process over diamond metal lath mesh to a 7/8th inch thickness or by other processes producing comparable cement stucco finish with equal or greater strength and durability specifications. Public Works/Engineering Review Alex Ayala, P.E. Civil Engineer (817) 748-8274 GENERAL COMMENTS: * Use the City of Southlake GPS monuments whenever possible. DRAINAGE COMMENTS: 1. Show the Base Flood Elevations (BFE) of the floodplain. 2. A Floodplain Development Permit will need to be filed with the City. * The discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance # 605. INFORMATIONAL COMMENTS: * Submit 4 copies of the civil construction plans (22” x 34” full size sheets) and a completed Construction Plan Checklist as part of the first submittal for review directly to the Public Works Administration Department. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website. http://www.cityofsouthlake.com/PublicWorks/engineeringdesign.asp * A ROW permit shall be obtained from the Public Works Operations Department (817) 748- 8082 to connect to the City’s sewer, water or storm sewer system. * A separate bond will be required for the Maintenance Bond and bound only unto the City of Southlake for a period of two years for all development projects. The Maintenance Bond cannot be tied to the Performance and Payment Bond in any way. Case No. Attachment D ZA12-003 Page 1 * Any hazardous waste being discharged must be pretreated, Ordinance No. 836. * This review is preliminary. Additional requirements may be necessary with the review of construction plans. Informational Comments * No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. * All mechanical equipment must be screened of view right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. * All lighting must comply with the Lighting Ordinance No. 693, as amended. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. * Denotes Informational Comment Case No. Attachment D ZA12-003 Page 2 Surrounding Property Owners Timarron Country Club SPO # Owner Zoning Land Use Acreage Response Jordan, Heidi Etvir John D RPUD Medium Density Residential 0.34 NR 1. Nauman, Scott A Etux Kimberly RPUD Medium Density Residential 0.35 NR 2. Paranandi, Srinivas Etux Lata RPUD Medium Density Residential 0.34 NR 3. Medium Density Residential, 100- Timarron Owners Assn Inc RPUD 5.90 NR 4. Year Flood Plain Buchholtz, Walter RPUD Medium Density Residential 0.90 NR 5. Mixed Use, Medium Density Timarron Golf Club Inc RPUD 8.72 NR 6. Residential, 100-Year Flood Plain Medium Density Residential, 100- Timarron Golf Club Inc RPUD 66.60 NR 7. Year Flood Plain Westerra Timarron Lp RPUD 100-Year Flood Plain 0.43 NR 8. Smith, Kevin Etux Stephanie RPUD Medium Density Residential 0.98 NR 9. Ellis, Gregory L Etux Tangie RPUD Medium Density Residential 0.75 NR 10. Pennington, Brent Etux Harriet RPUD Medium Density Residential 0.70 NR 11. Medium Density Residential, 100- Martin, Russell D RPUD 1.18 NR 12. Year Flood Plain Medium Density Residential, 100- Timarron Golf Club Inc RPUD 3.62 NR 13. Year Flood Plain Nabily, Nick F Etux Sonya S RPUD Medium Density Residential 0.35 NR 14. Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Fourteen (14) Responses Received: None (0) Case No. Attachment E ZA12-003 Page 1 Property Owner Responses None Case No. Attachment F ZA12-003 Page 1