Loading...
Item 7JCity of Southlake Department of Planning STAFF REPORT June 14, 2006 CASE NO: ZA06 -084 P ROJECT: Specific Use Permit for a Telecommunications Antenna — T- Mobile REQUEST: T- Mobile is requesting approval of a specific use permit for a telecommunications antenna and equipment cabinet on an existing pole at Carroll Senior High School. The purpose of the request is to add: 1) three (3) telecommunication antennas inside the existing pole; and 2) two (2) equipment cabinets on the ground within the existing tower compound. ACTION NEEDED: 1. Conduct public hearing 2. Consider specific use permit approval ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information (D) Site Plan Review Summary No. 1, dated June 2, 2006 (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses (G) Resolution No. 06 -038 (H) Full Size Plans (for Comnaissvion acrd Coimcil Members Only) STAFF CONTACT: Ken Baker (748 -8067) Dennis Killough (748 -8072) Case No. ZA 06 -084 BACKGROUND INFORMATION OWNER: APPLICANT: Carroll ISD T -Mobile PROPERTY SITUATION: 1501 W. Southlake Boulevard LEGAL DESCRIPTION: Lot IR, Block IR, Carroll High School Addition LAND USE CATEGORY: Public / Semi Public CURRENT ZONING: "S -P- P' Detailed Site Plan District HISTORY: -City Council approved a specific use permit for a new telecommunications tower of a flag pole structure type on May 17, 2005. P &Z ACTION: June 8, 2006; Approved (5 -0) subject to Site Plan Review Summary No. 1, dated June 2, 2006; as presented. STAFF COMMENTS: Attached is Site Plan Review Summary No. 1, dated June 2, 2006 N: Conuminitti Development MEMO 2006cases 06- 084SUP.doc Case No. Attachment A ZA 06 -084 Page 1 Vicinity Map Telecommunications Tower Case No. ZA 06 -084 NN Carroll Senior High School N Attachment B Page 1 1004 0 1000 2440 3404 Feet o � 00 I A b� �a I 'S" AND DESIGN TONER FOUNDATION BY OTHERS RECTION OR MOOIFlCAR AND FOUNDATION L BE MADE WTHOUT APPROVAL TRUGTURAL ENGINEER. B97E T -MOP RE TO PRONOE AIL TOWER STEEL & RF MATERIAL G.C. TO PR DE ANTENNA MOUNTS & RELATED HARDWARE. Q W J O IRA I 1 EA5= BUEDIRG W. KUTI -ILAKE BLVD. I ' n J EgSnNG I� U j PARKING AREA F —x —x —x-- EXISnNG C_� PARKINQ AREA ' VERIZON @ SENIOR HIGH - #164664A DA 2253 A J SOw'mSGa e �E BLV EXIIVX BUIONG NORTH �S GRAPIIC SCALE: i " =70' - - -- 70' 140' 210' V -1 11 R REA 7 L Q ` MIMI BUILDING EXISTNG ARK NG AREA L] � TRACK & REM 1 I. I. I� (E) IRE €5 E %ISBNG BRICK WALLED CGMPUJRD EXSTNG PARKING TENNIS 1.11T AREA �x BASEBALL FlF19 x x �X RFrfl M G1 4 PROJECT N0: DRAWN BY: R. N.ADLOCK CHECKED DY: J.M.G. 3 5/05/06 HNAL 2 4/46/04 HNAL PIARMH LOCAIICN 13/ 311 PH 0 3/15 /CE PREllMNARY Co i d 10 o$M1 J "& J gp 5MM L - � - -n IE VERIZON @ SENIOR HIGH - #164664A DA 2253 A ® ® SOw'mSGa e �E BLV XrZi n11E NORTH F. SITE FLAN GRAPIIC SCALE: i " =70' - - -- 70' 140' 210' V -1 2006 _.„,_nQ L - � - -n o � 00 i b � CfQ � NOS; T— MORIIE TO PROMDE ALL TDWER SIET]. h BF MATFRIN... QC. TO PROMDE ANTENNA MOUNTS @ RELATED HARDWARE. (2) 3'P 3URIM 3CN 4C PVC CONDUIT 11 ". IT. (E) COMMUNITY RACK W/ TELCO BOX TO NEW PPC UNIT (I) SO BURIED SCHAG PVC CONDUIT EUk YUYhH TOOK No (U(.A MtItH/UISBUNNtI:I AT (E) CCMMUNITY RACN NOTE: CC, TO PROMDE CONDUCTORS BROM TRANSFORMER TO Mc ER BASE NORTH 1 - m : j C \ I- 24 VIBE CAL BRIDGE - - iC�. �� i I I o� 31S I qQ BTS 2 \\\ ••. \v __ _.. a I I + \ NEW 4' NICE '- w — DRAAN BY: R. MAOLOCK 3 3/03/W RNAL 2 4(03 /OB HtE1'N- PIAIEOPoI LOCAiIUI N n NEW PFC UNIT VOUINTEU TO BRICK WALL NEW 12 WBE N W/ UNISTRUT Dol SAINC WFGIGHT BE CATS + \ NEW 4' NICE '- w (E) BRICK WAIL (E) TREES 7 — , -- _ / ACCESS BATE- d J 9 I ,1 - } B ,� NEW (2) BT,i CABINtIS -- - - ---- - -_— �— l F Ld- a., ✓d -:Ja ✓d _ — a T 7=7L _ I PROJECT Nb N n o � 00 I y A b � va ,� ANALYSIS AND DESIGN OF TOWER AND FOUNDATION BY OTHERS. NO ERECTION OR MODIFICATION OF TOWER AND FOUNDATION SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. EXIST. ANTENNAE IN CANISTER EX"MG SO' STREALTH POLE W/ NEW (3) QUAD ANiENNNS IN NEW CANISTER (T) ACT ANTENNA PER SECTOR SECTOR A. D' EN E' 1. ¢1- EECTDR B, T40 ® 51' RAD CENTER SEC- C, 2N0 W 5]' RAD CNTER 1.) TIIE SIZE, HEIGHT, ATE DIRECTION OF THE ANTENNA SHALL OF u STED TO .MEET SYSTEM REQUIREMENTS. 2.) CONTRACTOR SHALL VERIFY 'HEIGHT OF ANTENNA 'NIIH T- MOBILE RE DATA SHEET, 3.) CONTRACTOR SHALL V_RIFY TROUT AND DIRECTION OF MUO UISHES SL IF RF DATA SHEET. 4,) ALL ANTENNA AZIMUTH TO BE FROM TRUE NORTH. 10 B' HIGH BRICK SCREENING -` WALL \ _,_._._._._.J (E) TOP 0- STEEL (E) 90' 111tH STT_ALTR TONER (E) OUNOOR EOUIP ELEVAMN LOOKING NORTH _ NEW (FLTY RACK W/ PPG UNIT - NEW ITS CABINETS COAX CABLE IDENTIFICATION CONTRACTOR MUST PROVIDE EASY IDENTHCATION AND UNIFORM MARKING OF ANTENNA CABLING PER THE FUT I MIC .NCTION" 1, DOCAFIN: G SL BE MADE U51NG COLOR TAPE W/ 3" OF COVERAGE AFFIXED ATTIIREE PLACES ON — COAX CABLE RUN AS FOLLOWS: FIRST -ON THE COAX AT THE CONNECTOR NEAREST THE ANTENNA (WHERE THE COAX AND JUMPER ARE CONNECTED). SECOND - AT THE BASE OF THE TOWER STRUCTURE. (FOR TOWE25 ONLY). TTIRE - AT A POINT OUTSIDE THE ITS. (JUST PRIOR TO MGI' 2 DEC PTE WILL AVE H UP Tq TiREE LECTORS^ SECTORS SHAt- BE DESIGNATED A CLOCKWISE MANNER; 1.1 AtYHA EI 11 TO ZERO DEGREES ( NGRTH) TH- SETA AND GAMMA FOLLOW CLOCKWISE IN SEQUENCE. ALPHA SECTOR - RED BETA SECTOR - BLUE SEE SHEET C -5 GAMMA SECTOR - -1- 3. OMNI IDENTIFICATTON'. FOR GNM SITES, IPHCH NORMALLY CONSIST REF ANTFNNA, T 1 St CGEBTEO THAT THE GR1ENTAn qF THE OBSERVER ALSO BE THAT OF LOOKING IN A NORTHERLY COAX CABLE IDENTIFICATION CHART COAX BEND TABLE CABLE! ANDREW SIZE CABLE _ TYPE 9 MA1UF. MIN FEND _RADIUS HANGER ANDREW CA -. # CABLE TCIMAX CABLE SPACING VER. 1ANGER SPACING MAX H CO HANGER SPACING 1/2" LOF4 -50A 5" 206756 -1 1/2" - 4' -O 3' -0 7/B LDr5 -50A 10" 206756 -2 1/2" 4'-0" 3' -0" LDF7-50A 2C" 206756 -4 1/2" -0" 3' 0 "- 1/2' ( F5,74 -502 ( 1 -1/4" 206756 -1 1/2" _4' 4' -p " - 31 -E NOTE: PM /RF ENGINEER TO VERIFY 5 RUNS PER ANTENNA CURRENTLY (MAXIMLM 9 LINES, 3 LINES PER SECTOR) TOTAL COAX LENGTH: 765'± COAX GPEGHCARON TABLE ^\ AD 3 h M ¢ w LIAWN El R. MADLOCK CHECKED BY J.M.c. 3 5/05/06 RWI 2 4/05/05 MIN- PLATFORM LOCATION I 1 /N /N FINAL 0 3 T N PRHJMINARY O DL - R`P /D5 VERI?ON �P SOUTHIAKE SENIOR HIGH - #164654A DA-2253 -A EOUTI TX 70092 LL VN &ANTENNA DETNLS E� RECD MAY 2 6 2006 Z A 0 6- 0 8 4 w n COAXIAL CABLE TABLE SEC CDR CAI LE CABLE AZIMUTH LENGTH SIZE LOSSA TOTAL LOSS A 0' 85' 7/8" -_� 1.9 1.62 ON B 120• - -� 8 5' 7/8" 1.9 1.62 dB C 24 85' 7/8" 1 -9 1.62 GO 5 RUNS PER ANTENNA CURRENTLY (MAXIMLM 9 LINES, 3 LINES PER SECTOR) TOTAL COAX LENGTH: 765'± COAX GPEGHCARON TABLE ^\ AD 3 h M ¢ w LIAWN El R. MADLOCK CHECKED BY J.M.c. 3 5/05/06 RWI 2 4/05/05 MIN- PLATFORM LOCATION I 1 /N /N FINAL 0 3 T N PRHJMINARY O DL - R`P /D5 VERI?ON �P SOUTHIAKE SENIOR HIGH - #164654A DA-2253 -A EOUTI TX 70092 LL VN &ANTENNA DETNLS E� RECD MAY 2 6 2006 Z A 0 6- 0 8 4 w n SITE PLAN REVIEW SUMMARY Case No.: ZA06 -084 Review No.: One Date of Review: 6/02/06 Project Name: Site Plan for Telecommunications Tower SUP Carroll High School APPLICANT: T- Mobile 11830 Webb Chapel Rd, Suite 500 Dallas, TX 75234 Phone: (214) 523 -4100 Fax: (214) 523 -4101 OWNER: Carroll ISD Harry Ingalls 3051 Dove Rd. Grapevine, TX 76051 Phone: (817) 949 -8260 Fax: CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 5/22/06 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DENNIS KILLOUGH AT (817) 481 -2073. Show the parking stall intended for off - street parking. Label the dimensions of the parking space. One (1) all weather surface parking space shall be provided on each site. Informational Comments: * A fully corrected plan that includes all associated support plans /documents and conditions of approval is required before any ordinance or zoning verification letter publication or before acceptance of any other associated plans for review. Plans and documents must be reviewed and stamped "approved" by the Planning Department. * All development must comply with the City's Drainage Ordinance No. 605 and detain all post development run -off. After receiving the appropriate zoning approval, no tower, antenna, or other appurtenance shall be installed without first obtaining a building permit issued by the Building Official. * The applicant should be aware that the following issues must be addressed either prior to issuance of a building permit and /or during the operational period of the tower: a) All towers shall meet or exceed current standards and regulations of the FAA, the FCC, and any other agency of the federal or state government with the authority to regulate towers and antennas. If such standards and regulations are changed, then the owners of the towers and antennas governed by this ordinance shall bring such towers and antennas into compliance with such revised standards and regulations within six (6) months of the effective date of such standards and regulations, unless a more stringent compliance schedule is mandated by the controlling federal agency. Failure to bring towers and antennas into compliance with such Case No. ZA 06 -084 Attachment D Page 1 revised standards and regulations shall constitute grounds for the removal of the tower or antenna at the owner's expense. b) Applicants shall provide the city with certification of compliance with ANSI and IEEE Standards regarding human exposure to non - ionizing electromagnetic radiation ( "NIER" ). c) For antennas, towers and /or supporting structures which are to be located in residential neighborhoods and that are to be equipped with high intensity white lights, the applicant shall provide the city with certification from the FCC of EA approval. d) To ensure the structural integrity of towers, the owner of a tower shall ensure that the tower is constructed and maintained in compliance with standards contained in applicable local building codes ( "Uniform Building Codes, UBC ") and applicable standards for towers, published by the Electronics Industries Association Standard 222, ( "EIA- 222 ") "Structural Standards for Steel Antenna towers and Antenna Support Structures." e) A tower inspection report (based upon applicable UBC and EIA -222 standards) shall be prepared by an engineer licensed in the state of Texas and filed with the Building Official in accordance to the following schedule: a) monopoles - -at least once every ten (10) years; b) lattice towers - -at least once every (5) years; and c) guyed towers - -at least once every three (3) years. However, the Building Official may require an immediate inspection should an issue of safety be raised. f) If, upon inspection, the tower fails to comply with such codes and standards and constitutes a danger to persons or property, then upon notice being provided to the owner of the tower, the owner shall have thirty (30) days to bring such tower into compliance with such standards, unless the applicant can demonstrate a hardship and thus establish the need for additional time. If the owner fails to bring such tower into compliance within said thirty (3 0) days, the city shall remove such tower at the owner's expense. g) The applicant shall provide the city with a certificate of insurance, issued by an insurance company licensed to do business in the state of Texas indicating that the applicant carries comprehensive general liability insurance with limits of liability thereunder of not less than: bodily injury: $500,000 for injury to any one person and $1,000,000 for all injuries sustained by more than one person in any occurrence; property damage: $1,000,000 for damage as a result of any one accident. The applicant shall provide the city with a renewal certificate within then (10) business days of each renewal. Any insurance required to be provided by the applicant herein may be provided by a blanket insurance policy covering this property and other locations occupied by the applicant, provided such blanket insurance policy complies with all ofthe other requirements as to the type and amount of insurance required. The applicant may also fulfill the requirements under this section through a program of self - insurance, subject to approval by the city, which approval shall not be unreasonably withheld. If the applicant elects to self - insure, then the applicant shall furnish the city with a letter stating that there is a self - insurance program in effect that provides for the same, or greater, coverage than required ofthe applicant herein. The applicant agrees to furnish the city with certificate of insurance certifying that the applicant has in force and effect the above specified insurance. The certificate and renewal Case No. ZA 06 -084 Attachment D Page 2 certificates shall provide that insurance shall not be canceled or changed unless 30 days' prior written notice is just given to the city. h) Each backhaul provider shall be identified and have all necessary franchises, permits, and certificates. The identity of other providers who co- locate to the site and their backhaul providers shall be provided as well. i) No lettering, symbols, images, or trademarks large enough to be legible to occupants of vehicular traffic on any adjacent roadway shall be placed on, or affixed to, any part of a telecommunications tower, platform, antenna or ancillary structure. j) All construction shall comply with all ordinances of the city not in conflict with this section. k) In addition to the usual application fees for rezoning or specific use permit requests, the applicant shall reimburse the city the actual cost of professional services, provided by an engineer or other professional, which may be required to review the application and provide expertise. 1) If high voltage is necessary, signs shall be posted every 20' on any exterior fencing which state, "Danger- -High Voltage." The operator shall also post "No Trespassing" signs. m) Any signal interference complaints associated with telecommunications towers or related equipment shall be addressed in accordance with FCC rules and procedures. n) The owner of a tower and /or related telecommunications facilities shall notify the Building Official when the tower or other structures have ceased operating as part of a telecommunications system authorized by the FCC. Within six (6) months of the date the tower ceases to operate as part of an authorized telecommunications system, the tower must either be removed from the site, or a certificate of occupancy must be obtained to allow another permitted use of the tower. If within six (6) months, the owner fails to remove the tower or obtain proper authorization for the use of the tower, the Building Official shall revoke the certificate of occupancy for the tower and notify the city attorney to pursue enforcement remedies. o) Tower owner(s) shall bear all demolition costs. * The applicant should be aware that prior to issuance of a building permit a site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Perimeter Street Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. Case No. Attachment D ZA 06 -084 Page 3 Surrounding Property Owners Carroll Senior High School 0[ 7 O U7 24 1 22 23 L 21 20 1 19 WEST SOUTHLAKE BLVD 25 5 26 27 28 6 29 57 30 58 34 33 32 31 A 3 35 36 2 37 38 1 39 W 53 40 41 52 43 42 51 44 G S H �' 45 C 56 47 V54 48 46 � 18 17 16 15 14 13 12 11 10 9 8 49 L FT F= FFT 50 /� Owner Zoning Land Use Acreage 1. May, Clentis L & Wanda J S -P -2 Medium Density Residential 0.96 2. Akard, Larry W S -P -2 Medium Density Residential 0.96 3. May, Wanda Jean S -P -2 Medium Density Residential 1.91 4. Carroll ISD S -13-1 Medium Density Residential 55.03 5. Bradner Central Co C -2 Retail Commercial 2.6 6. Ott Real Estate Inv Ltd 0-1 Retail Commercial 1.349 7. Myers Meadow HOA R -PUD Medium Density Residential 4.964 8. Seitz, Kerry A & Suzanna J SF -20A Medium Density Residential 0.518 9. Swieter, Kenneth & Danielle SF -20A Medium Density Residential 0.461 10. Mamerow, Bernard S Jr & H SF -20A Medium Density Residential 0.459 11. Hammond, Robert D & Pamela SF -20A Medium Density Residential 0.459 12. Howell, Glenna Jinx SF -20A Medium Density Residential 0.459 13. Vassios, Michael T & Lisa J SF -20A Medium Density Residential 0.459 14. Little, Steven & Leigh SF -20A Medium Density Residential 0.459 Case No. Attachment E ZA 06 -084 Page 1 15. Vanyo, Carole L SF -20A Medium Density Residential 0.459 16. Robinson, Kenneth M SF -20A Medium Density Residential 0.046 17. Simcho, David M SF -20A Medium Density Residential 18. Rogers, Dennis P & Sheila C SF -20A Medium Density Residential 0.466 19. Southridge Lakes HOA C -3 Retail Commercial 3.182 20. Realty Income Texas Prop LP C -3 Retail Commercial 0.949 21. Southlake Blvd Presbyterian Ch CS Retail Commercial 5.165 22. Southlake Safeco Ltd C -3 Retail Commercial 1.234 23. Southlake 114 Investors C -3 Retail Commercial 0.782 24. 7- Eleven Inc C -3 Retail Commercial 0.918 25. Bologna, Anthony & Susan R -PUD Medium Density Residential 0.585 26. Nuese, David V & Sandra K R -PUD Medium Density Residential 0.353 27. Rabbani, Mahmood & Mahnaz R -PUD Medium Density Residential 0.435 28. Harless, William & Mary A R -PUD Medium Density Residential 0.393 29. Rodgers, Craig & Kathy R -PUD Medium Density Residential 0.387 30. Whitacre, Charles & Vaunda R -PUD Medium Density Residential 0.389 31. Jain, Anuj & Bhanu R -PUD Medium Density Residential 0.378 32. Kapich, Jack & Kelly R -PUD Medium Density Residential 0.346 33. Wendell, Barry & Jamie R -PUD Medium Density Residential 0.359 34. George, Daniel & Susan R -PUD Medium Density Residential 0.531 35. Lambeth, Jeffrey & Felicia R -PUD Medium Density Residential 0.565 36. Stelling, Richard & Jennifer R -PUD Medium Density Residential 0.403 37. Saeed, Quaiser & Samrin R -PUD Medium Density Residential 0.33 38. Griffeth, Suzanne R -PUD Medium Density Residential 0.445 39. Bruce Family Trust R -PUD Medium Density Residential 0.535 40. Williams, Richard & Patricia R -PUD Medium Density Residential 0.428 41. Palmer, Wilfred M R -PUD Medium Density Residential 0.371 42. Naughton, James S & Lela R -PUD Medium Density Residential 0.313 43. Dominici, James P & Maria R -PUD Medium Density Residential 0.522 44. Sivula, Antii & Kirsti R -PUD Medium Density Residential 0.556 45. Roberts, Sean F & Deena R R -PUD Medium Density Residential 0.594 46. Schafer, Thomas C R -PUD Medium Density Residential 0.352 47. Armstrong, Edward & Kathryn R -PUD Medium Density Residential 0.726 48. Finn, Robert E Jr & Tammy R -PUD Medium Density Residential 0.413 49. McGovern, Richard & Brenda R -PUD Medium Density Residential 0.328 50. Gilmore, Edward & Lagel S R -PUD Medium Density Residential 0.299 51. Tan, Simon & Jennie SF -20A Medium Density Residential 0.477 52. Park, Louis & Tina SF -20A Medium Density Residential 0.477 53. Lewandowski, Mark & Audra SF -20A Medium Density Residential 0.725 54. Grieco, Joseph & Nina SF -20A Medium Density Residential 0.523 55. Siegler, Steve & Andrea SF -20A Medium Density Residential 0.465 56. Southlake Woods LP SF -20A Medium Density Residential 57. Davis, Donald S -P -2 Medium Density Residential 1.0 58. Greenwood, Robert Curtis S -P -2 Medium Density Residential 0.98 Case No. ZA 06 -084 Attachment E Page 2 Surrounding Property Owner Responses T -Mobile Telecommunications Antenna — Carroll Senior High School Notices Sent: Fifty -Six (56) Responses Received: None (0) Case No. ZA 06 -084 Attachment F Page 1 RESOLUTION NO. 06 -038 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS, GRANTING A SPECIFIC USE PERMIT FOR TELECOMMUNICATIONS TOWERS, ANTENNAS, AND ANCILLARY BUILDINGS ON PROPERTY WITHIN THE CITY OF SOUTHLAKE, TEXAS, BEING LEGALLY DESCRIBED AS LOT 1R, BLOCK 1R, CARROLL HIGH SCHOOL ADDITION, MORE FULLY AND COMPLETELY DESCRIBED IN EXHIBIT "A", AND AS DEPICTED ON THE APPROVED CONCEPT PLAN ATTACHED HERETO AND INCORPORATED HEREIN AS EXHIBIT "B" AND PROVIDING AN EFFECTIVE DATE. WHEREAS, a Specific Use Permit for telecommunications towers, antennas, and ancillary buildings has been requested by a person or corporation having a proprietary interest in the property zoned as "S -P -1" Detailed Site Plan District; and, WHEREAS, in accordance with the requirements of Section 45.1 (3 1) and Section 45.8 of the City's Comprehensive Zoning Ordinance, the Planning and Zoning Commission and the City Council have given the requisite notices by publication and otherwise, and have afforded the persons interested and situated in the affected area and in the vicinity thereof, and, WHEREAS, the City Council does hereby find and determine that the granting of such Specific Use Permit is in the best interest of the public health, safety, morals and general welfare of the City. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: SECTION 1. A Specific Use Permit is hereby granted for the telecommunications towers, antennas, and ancillary buildings on the property being legally described as 1R, Block 1R, Carroll High School Addition, an addition to the City of Southlake, Tarrant County, Texas, according to the plat recorded in Cabinet `A', Slide s 6415 & 6416, Plat Records, Tarrant County, Texas, more fully and completely described in Exhibit "A ", and as depicted on the approved Concept Plan attached hereto and incorporated herein as Exhibit `B" and providing Case No. Attachment G ZA06 -084 Page 1 an effective date, subject to the provisions contained in the comprehensive zoning ordinance and the restrictions set forth herein. The following specific requirements and special conditions shall be applicable to the granting of this Specific Use Permit: 1. SECTION 2. This resolution shall become effective on the date of approval by the City Council. PASSED AND APPROVED THIS DAY OF , 2006. CITY OF SOUTHLAKE ATTEST: Lori Farwell, TRMC City Secretary IM Andy Wambsganss, Mayor Case No. Attachment G ZA06 -084 Page 2 EXHIBIT "A" Being legally described as 1R, Block 1R, Carroll High School Addition, an addition to the City of Southlake, Tarrant County, Texas, according to the plat recorded in Cabinet `A', Slide s 6415 & 6416, Plat Records, Tarrant County, Texas. Case No. ZA06 -084 Attachment G Page 3 o 0 c 00 . 1� b � va ,� � ANALY51S AND D =SIGN Of TOWER AND FWNDARCN BY OTHERS ND ERECTION OR NMIETCATION 0= TOWER AND EWNUATON SNALL RE MADE WITHWT ARRROVAE. Or STRUCTURAL ENGINEER. N07F' T- MDRIIF. TO RRONDE Al L TOWER STEEL & RF MATERIAL G.C. TO FRDMDE ANTENNA MWNT5 & RELATED HARDWARE. LZ N I W J Z T Ezlsrnc //��BU LONG //z, BUII➢INC i� m IAAQ(& FIEIU I u ( (E) TREES W. SQUTI LAKE DI-W. E %(STING EMD< WAIIFL f.INA _T �X RFr.En m Y Xq di PRO.EC' ND: DRAWN RY; R. N.AOLO_K CiECKED BY: .I.M.G 3 3,05/06 INNPL 2 "1 6 PRELIM- P LOC611W I 1AIIA (FINAL 0 3/11/:4 IPR l..lWY 6/805 I II I ', � DAGEEALL FlELO r I N OR TH E %(STING EMD< WAIIFL f.INA _T �X RFr.En m Y Xq di PRO.EC' ND: DRAWN RY; R. N.AOLO_K CiECKED BY: .I.M.G 3 3,05/06 INNPL 2 "1 6 PRELIM- P LOC611W I 1AIIA (FINAL 0 3/11/:4 IPR l..lWY 6/805 Z w H� H i I_ AREAING I� U I— VERTZON S0IITHLAKE. SENIOR HIGH - #164654A DA- 2253 -A ro KNI. G1 N OR TH F— RA siTE eLAn GR A('i i!C SCALE: i " -70' - - - -- !✓ ®1 a 70' 140' 210' O A Z w H� H i I_ AREAING I� U I— o 0 c 00 i b � NOS; T— MORIIE TO PROMDE ALL TDWER SIET]. h BF MATFRIN... QC. TO PROMDE ANTENNA MOUNTS @ RELATED HARDWARE. (2) 3'P 3URIM 3CN 4C PVC CONDUIT 11 ". IT. (E) COMMUNITY RACK W/ TELCO BOX TO NEW PPC UNIT (I) SO BURIED SCHAG PVC CONDUIT EUk YUYhH TOOK No (U(.A MtItH/UISBUNNtI:I AT (E) CCMMUNITY RACN NOTE: CC, TO PROMDE CONDUCTORS BROM TRANSFORMER TO Mc ER BASE NORTH -E ,/2 -1. m : j C \ I- 24 VIBE CAL BRIDGE - - iC�. �� i I I o� 31S I qQ BTS 2 \\\ ••. \v __ _.. a I I + \ NEW 4' NICE '- w — DRAAN BY: R. MAOLOCK 3 3/03/W RNAL 2 4(03 /OB HtE1'N- PIAIEOPoI LOCAiIUI "K4_1 NEW PFC UNIT VOUINTEU TO BRICK WALL NEW 12 WBE N W/ UNISTRUT Dol SAINC WFGIGHT BE CATS + \ NEW 4' NICE '- w (E) BRICK WAIL (E) TREES 7 — , -- _ / ACCESS BATE d - J 9 I ,1 - } B ,� NEW (2) BT,i CABINtIS -- - - ---- - -_— �— l F Ld- a., ✓d -:Ja ✓d _ — a T 7=7L _ I PROJECT Nb "K4_1 o 0 c 00 I A b � va ,� ANALYSIS AND DESIGN OF TOWER AND FOUNDATION BY OTHERS. NO ERECTION OR MODIFICATION OF TOWER AND FOUNDATION SHALL BE MADE WITHOUT APPROVAL OF STRUCTURAL ENGINEER. EXISTING ANTENNAE IN CANISTER EX"MG SO STREALTH POLE W/ NEW (3) QUAD ANiENNNS IN NEW CANISTER (T) ACT ANTENNA PER SECTOR SECTOR A. D' EN E' 1. ¢1- RECTOR B, T40 ® 51' RAD CENTER SEC- C, 2N0 W 5]' RAD CNTER 1.) TIC SIZE, HEIGHT, ATE DIRECTION OF THE ANTENNA SHALL OF u STED TO .MEET SYSTEM REQUIREMENTS. 2.) CONTRACTOR SHALL VERIFY 'HEIGHT OF ANTENNA 'NIIH T- MOBILE RE DATA SHEET, 3.) CONTRACTOR SHALL V_RIFY TROUT AND DIRECTION OF MUO UISHES SL IF RF DATA SHEET. 4,) ALL ANTENNA AZIMUTH TO BE FROM TRUE NORTH. 10 B' HIGH BRICK SCREENING -` WALL \ _,_._._._._.J (E) TOP 0- STEEL (E) 90' HIGH STEALTH TONER (E) OUNOOR EOUIP ELEVAMN LOOKING NORTH NEW UTUT RACK W/ PPG UNIT - NEW ITS CABINETS COAX CABLE IDENTIFICATION CONTRACTOR MUST PROVIDE EASY IDENTHCATION AND UNIFORM MARKING OF AN7NNA CABLING PER THE FUT I MIC .NCTION" 1, LOCATION. L BE MADE U51NG COLOR TAPE W/ 3" OF COVERAGE AFFIXED G IT 5 FIABE PLACES ON — COAX CABLE RUN AS FOLLOWS: FIRST -ON THE COAX AT THE CONNECTOR NEAP.EST THE ANTENNA (WHERE THE COAX AND JUMPER ARE CONNECTED). SECOND - AT THE BASE OF THE TOWER STRUCTURE. (FOR TOWE25 ONLY). THIRD - AT A POINT OUTSIDE THE ITS. (JUST PRIOR TO MGT' 2 DEC PTE WILL AVE H UP Tq TiREE EECTON SECTORS SHAL- BE DESIGNATED A CLOCKWISE MANNER; 1.1 AtYHA EI 11 TO ZERO DEGREES ( NGRTH) TH- SETA AND GAMMA FOLLOW CLOCKWISE IN SEQUENCE. ALPHA SECTOR - RED BETA SECTOR - BLUE SEE SHEET C -5 GAMMA CECTGR - -1- 3. OMNI IDENTIFICATTON'. FOR GNM SITES, IPHCH NORMALLY CONSIST REF ANTFNNA, T 1 St CGEBTEO THAT THE GR1ENTAn qF THE OBSERVER ALSO BE THAT OF LOOKING IN A NORTHERLY COAX CABLE IDENTIFICATION CHART COAX BEND TABLE CABLE! ANDREW SIZE CABLE _ TYPE 9 MA1UF. MIN FEND _RADIUS HANGER ANDREW CA -. # CABLE TCIMAX CABLE SPACING VER. 1ANGER SPACING MAX H CO HANGER SPACING 1/2" LOF4 -50A 5" 206756 -1 1/2" - 4' -O 3' -0 7/B LDr5 -50A 10" 206756 -2 1/2" 4'-0" 3' -0" LDF7-50A 2C" 206756 -4 1/2" -0" 3' 0 "- 1/2' ( F5,74 -502 ( 1 -1/4" 206756 -1 1/2" _4' 4' -p " - 31 -U NOTE: PM /RF ENGINEER TO VERIFY 5 RUNS PER ANTENNA CURRENTLY (MAXIMLM 9 LINES, 3 LINES PER SECTOR) TOTAL COAX LENGTH: 765'± COAX GPEGHCARON TABLE ^\ AD 3 h M ¢ w OIAWN El R. MADLOCK CHECKED BY J.M.c. 3 5/05/06 RWI 2 4/05/05 NIN-PUJfOFM LOCATION I 1 /N /N FINAL 0 3 l N PRIMMINARY O DL - R`P /D5 VERI?ON �P SOUTHIAKE SENIOR HIGH - #164654A DA-2253 -A SOUT —,TX 70092 LL VN &ANTENNA DETNLS E ® i ] RECD MAY 2 6 2006 Z A 0 6- 0 8 4 Mmil COAXIAL CABLE TABLE SEC CDR CAI LE CABLE AZIMUTH LENGTH SIZE LOSSI TOTAL LOSS A 0' 85' 7/8" -_� 1.9 1.62 ON B 120• - -� 8 5' 7/8" 1.9 1.62 dB C 24 85' 7/8" 1 -9 1.62 GO 5 RUNS PER ANTENNA CURRENTLY (MAXIMLM 9 LINES, 3 LINES PER SECTOR) TOTAL COAX LENGTH: 765'± COAX GPEGHCARON TABLE ^\ AD 3 h M ¢ w OIAWN El R. MADLOCK CHECKED BY J.M.c. 3 5/05/06 RWI 2 4/05/05 NIN-PUJfOFM LOCATION I 1 /N /N FINAL 0 3 l N PRIMMINARY O DL - R`P /D5 VERI?ON �P SOUTHIAKE SENIOR HIGH - #164654A DA-2253 -A SOUT —,TX 70092 LL VN &ANTENNA DETNLS E ® i ] RECD MAY 2 6 2006 Z A 0 6- 0 8 4 Mmil