Loading...
Item 6ECity of Southlake Department of Planning & Development Services S T A F F R E P O R T September 12, 2007 ZA07-085 CASE NO: Zoning Change and Concept Plan for Shady Oaks PROJECT: REQUEST: Terra Shady Oaks is requesting approval of a zoning change and concept plan from "AG" Agricultural District to "SF-20A" Single Family Residential District. The plan proposes the development of 136 single-family residential lots and 17open space lots on approximately 96.3 acres. The plan proposes the following: Gross Acreage 96.3 Ac. Net Acreage 82.3 Ac. Area of Open Space 8.7 Ac. (9.1%) Number of Residential Lots/Units 136 Gross Density 1.41 du/ac Net Density 1.65 du/ac The following variances are requested: 1) Allow a minimum 40’ ROW instead of a 50’ ROW for the local residential streets is requested. The collector street will remain at a minimum 60’ ROW. 2) Allow the collector street geometry as proposed having a minimum 210’ radius with no tangents. A minimum 400’ CL radius and minimum 50’ tangent lengths is required for 2 lane collector streets. 3) Allow minimum 20’ side yard setback adjacent to the street on corner lots rather than a full front yard setback of 35’. Lots included are Lots 1, 8, 10, Block 2; Lot 9, Block 3 4) Relief from the 125’ rear lot width requirement is requested on Lots 5, 6, 8-10, Block 1 and Lots 3, 11 and 12, Block 3. A fencing plan, streetscape exhibits and open space details are included in the presentation booklet provided with the full size plan set. Case No. ZA07-085 1. Conduct public hearing ACTION NEEDED: 2. Consider approval of second reading for zoning change and concept plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information Concept Plan Review Summary No. 5, dated September 12, 2007 (D) (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses (G) SPIN Meeting Summary Report (H) Ordinance No. 480-531 (I) Full Size Plans (for Commission and Council Members Only) STAFF CONTACT: Ken Baker (748-8067) Dennis Killough (748-8072) Case No. ZA07-085 BACKGROUND INFORMATION OWNER/APPLICANT: Terra Shady Oaks PROPERTY SITUATION: 820, 910, 1020 Shady Oaks Drive, 985, 1005, 1125 North Peytonville Avenue LEGAL DESCRIPTION: Tracts 11, 11C, 11C2, 11C2A, 11C7, 11D, 11D1, 11E, 11F, and a portion of Lot 2, situated in the T. Hood Survey, Abstract No. 706 LAND USE CATEGORY: Medium Density Residential CURRENT ZONING: “AG” Agricultural District REQUESTED ZONING: “SF-20A” Single Family Residential District HISTORY: There is no development history on this property. A home currently exists on the eastern half of the proposed subdivision and is planned to be removed. TRANSPORTATION Mobility &Master Thoroughfare Plan ASSESSMENT: The Master Thoroughfare Plan designates that N. Peytonville Avenue be a 2- lane, undivided collector street with 70 feet of right-of-way, that Shady Oaks Drive be a 2-lane, undivided collector street with 60 feet of right-of-way, and that there be a 2-lane, undivided collector street with 60 feet of right-of-way connecting N. Peytonville Avenue and Shady Oaks Drive. The appropriate amount of right-of-way is shown to be dedicated for both N. Peytonville Avenue and Shady Oaks Drive. The recommended collector street between N. Peytonville Avenue and Shady Oaks Drive has not been shown to provide a direct connection. The street has an intersection and a 90 degree turn as part of the design. Street Typology Recommendation: The street typology designation for these roadways is ‘Collector.’ The design priorities outlined in the plan for Collectors are:  Medium to low pedestrian orientation with multi-use trails on one or both sides of the street providing connectivity between neighborhoods and to non-residential uses.  Usually lacking in curb-gutter.  High level of resource protection with an emphasis on leaving the road as natural as possible by retaining any mature street trees along the roadway.  Limit intersection improvements to turn lanes and roundabouts where appropriate. Case No. Attachment A ZA07-085 Page 1  Narrow lane-widths conducive to lower-speed traffic.  Low access control due to existing nature of development along these corridors. Recommended Cross-Section for N. Peytonville Ave & Shady Oaks Dr. Existing Area Roadway Network The proposed development will have one (1) street intersecting with N. Peytonville Avenue and one (1) street intersecting with Shady Oaks Drive. N. Peytonville Avenue and Shady Oaks Drive are currently 2-lane undivided roadways without curb and gutter. The 2006 traffic counts for these roadways are presented in the following tables. May, 2006 traffic counts on N. Peytonville Ave (between Southridge Lakes & W. Dove St): 24hr 2,1162,219 North Bound (NB) () South Bound (SB) () NB 355170 Peak A.M. () Peak P.M. () 7:30 - 8:30 AM 4:15 - 5:15 PM SB 163346 Peak A.M. () Peak P.M. () 7:30 - 8:30 AM 5:00 - 6:00 PM May, 2006 traffic counts on Shady Oaks Dr (between F.M. 1709 & W. Highland St): 24hr 1,9111,687 North Bound (NB) () South Bound (SB) () NB 380212 Peak A.M. () Peak P.M. () 7:45 - 8:45 AM 4:45 - 5:45 PM SB 392206 Peak A.M. () Peak P.M. () 7:45 - 8:45 AM 4:45 - 5:45 PM Case No. Attachment A ZA07-085 Page 2 Traffic Impact Use # Lots Vtpd* AM-AM-PM-PM- IN OUT IN OUT Number of Single-Family 136 1,301 26 77 88 49 Residential Lots *Vehicle Trips Per Day **The AM/PM times represent the number of vehicle trips generated during the peak travel times on N. Peytonville Ave and Shady Oaks Dr. PATHWAYS MASTER PLAN: A 6-foot sidewalk is proposed along the east side of N. Peytonville Avenue on the Pathways Master Plan. An 8-foot multi-use trail is planned along the south side of the proposed collector street connecting N. Peytonville Avenue and Shady Oaks Drive. The trail has been provided along the street system designed with the development. WATER & SEWER: Water: A 12-inch water line currently exists along the west side of N. Peytonville Avenue and also along the east side of Shady Oaks Drive. Sewer: A 6-inch sanitary sewer line stub-out currently exists in the subdivision to the south. Also, a 6-inch sanitary sewer line exists on the east side of N. Peytonville Avenue just south of the limits of the proposed subdivision. DRAINAGE ANALYSIS: The northeast portion of the site generally drains to two proposed detention ponds. The north central portion generally drains to a proposed detention pond which would connect with the existing Coventry detention pond system. The southeastern portion generally drains to Shady Oaks Drive. The southwestern portion generally drains to an existing off-site drainage system. TREE PRESERVATION: See Tree Conservation Analysis in Attachment ‘D’ of this report. Environmental Resource Protection Recommendations SOUTHLAKE 2025: The Environmental Resource Protection (ERP) Plan recommends preserving trees whenever feasible. Specifically, the ERP map identifies a portion of this property as a priority area for preservation: Case No. Attachment A ZA07-085 Page 3 The applicant has shown the ERP preservation area on the Tree Conservation Plan and the majority of the trees in the preservation area will be saved. Across the entire site, the majority of the existing trees will be saved. Mobility & Master Thoroughfare Plan Recommendations The Mobility & Master Thoroughfare Plan calls for a 60 foot 2 lane east-west collector across this property. The applicant is proposing a residential street instead of the recommended collector. Staff recommends realigning the through street so as to minimize the number of residential lots fronting on it. P&Z ACTION: August 9, 2007; Approved to table until August 23, 2007. August 23, 2007; Approved (5-1) subject to Concept Plan Review Summary No. 3, dated August 17, 2007; granting the requested variances. COUNCIL ACTION: September 4, 2007; Approved first reading (7-0) subject to: Sidewalks tied in to exterior of the subdivision as presented by the o applicant Subject to developer’s presentation o Perimeter walls as presented o Last lot on Street A – transition for wall by next meeting o Connector street to be built with phase 2 o Interior fencing – wrought iron o Fencing on blk 7 lot 5, 6, 7 and all such lots by next meeting o Developer’s agreement details to be worked out between developer and o staff to be approved by Council Case No. Attachment A ZA07-085 Page 4 Granting requested variances (40’ ROW, geometric design standards, o side yard setback) Subject to Concept Plan review summary o STAFF COMMENTS: Attached is Concept Plan Review Summary No. 5, dated September 12, 2007. N:\Community Development\MEMO\2007cases\07-085ZCP.doc Case No. Attachment A ZA07-085 Page 5 Case No. Attachment B ZA07-085 Page 1 Concept Plan Case No. Attachment C ZA07-085 Page 1 Tree Conservation Plan Case No. Attachment C ZA07-085 Page 2 Tree Survey Case No. Attachment C ZA07-085 Page 3 Case No. Attachment C ZA07-085 Page 4 Case No. Attachment C ZA07-085 Page 5 Case No. Attachment C ZA07-085 Page 6 Case No. Attachment C ZA07-085 Page 7 Case No. Attachment C ZA07-085 Page 8 Case No. Attachment C ZA07-085 Page 9 Case No. Attachment C ZA07-085 Page 10 ZONING/CONCEPT PLAN REVIEW SUMMARY ZA 07-085Five09/12/07 Case No: Review No: Date of Review: Zoning /Concept Plan – Shady Oaks, 96.3 Acres in the T.M. Hood Survey Abstract No. Project Name: 706, Southlake Tarrant County, Texas APPLICANT: Phone: (817) 589-0000 Terra Shady Oaks, LP Phone: (817) 410-9201 PLANNER: Sage Group Phone: (972) 929-8443 ENGINEER: Deotte Engineering CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 09/11/07 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DENNIS KILLOUGH AT (817) 748-8072. 1.Provide easements for water, sewer and/or drainage in compliance with approved engineering & construction plans. (Variance requested, 2.Provide minimum rear lots lines of 125’ for lots adjacent to platted 1acre+ lots. for Lots 5,6, 8-10, Block 1 & Lots 3, 11 & 12, Block 3) 3.A minimum 35’ BL is required along all street fronts. A minimum 20’ BL is requested along the side (Variance requested for Lots 1, 8 & 10, Block 2 and Lot 9, Block 3) street of corner lots. 4.The following changes are needed with regard to ROW’s: a.A minimum 50’ ROW is required for local residential streets. A40’ ROW is proposed (Variance is requested) b.The collector street must meet the minimum geometric design standards of the subdivision ordinance. A minimum 400’ CL radius, 50’ tangent lengths is required for 2 lane collector (A variance is requested) streets. c.Label approximate centerline data. d.Label streets with a unique name for ease of identification. A, B, C ... can be used until actual names are developed. 5.Include the square footage or approximate acreage of open space in the data summary. Ensure that it is accurately represented. Also, the most eastern median area appears to be problematic with regard to maintenance and how close the two roads come together. Staff recommends redesigning. Case No. Attachment D ZA07-085 Page 1 The following should be informational comments only ============= ==================== * A fully corrected plan that includes all associated support plans/documents and conditions of approval is required before any ordinance or zoning verification letter publication or before acceptance of any other associated plans for review. Plans and documents must be reviewed and stamped “approved” by the Planning Department. * A minimum 60’ wide collector connecting Shady Oaks Drive and N. Peytonville Avenue is designated through this property. Street A, B & C provides for this connection. The developer and builders should be aware that driveways must comply with the Driveway Ordinance No. 634, as amended. As currently written, the minimum residential driveway spacing between residential driveway centerlines is 40 feet and the minimum spacing between the driveway centerlines and the nearest intersecting street ROW’s boundary is 50 feet. * All development must comply with the City’s Drainage Ordinance No. 605 and detain all post development run-off. * The Fire Department requires two physical points of emergency access or that all homes be installed with a fire sprinkler system for subdivisions having more than 30 lots. Although there are two planned points of access which complies with the subdivision ordinance, the phasing plan does not provide the two physical access points following construction of the first 30+ lots. The applicant has indicated in their attached letter that all homes are to have a fire sprinkler system. * On subsequent final plats, two intervisible boundary corners of the site must be geo-referenced by state plane coordinates in accordance with section 8.03(B) of the Subdivision Ordinance No. 483 upon submittal of the final plat, and, prior to acceptance of the subdivision by the City, a digital computer file of the subdivision must be provided in accordance with Section 8.04 of Ordinance No. 483. * A final plat must be approved and filed of record in the county and all required infrastructure be approved and accepted by the City prior to issuance of a building permit for construction. * Denotes Informational Comment Case No. Attachment D ZA07-085 Page 2 Case No Review No.Dated: Number of Pages: . 07-085 Four August 29, 2007 1 Project Name: Shady Oaks (Zoning Change/Concept Plan) ContactPhone:Fax: : Keith Martin (817) 748-8229 (817) 481-5713 =========================================================================== The following comments are based on the review of plans received on August 29, 2007 . Comments designated with a number may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z or City Council. It is the applicant’s responsibility to contact the department representative shown above and make modifications as required by the comment. =========================================================================== TREE CONSERVATION: 1. The Tree Conservation Plan shows the percentage of existing trees to be preserved instead of the percentage of existing tree canopy cover to be preserved. Since the existing trees within the east portion of the property are spaced more apart than the trees in the west portion of the property, it is better to provide the preservation information on a tree-to-tree basis. Only 8.12% percent of the existing trees on the development site are proposed to be removed for the full development of the subdivision. This percentage does not include the existing trees within the proposed right-of-way as allowed by Ordinance 585-C. 2 Most all of the existing trees on the property are large Post Oaks that have benefited from growing in a pasture like setting for many years. There are also some Blackjack Oaks, Pecan, American Elm, Sycamore, and Eastern Red Cedar. Street “A” cuts through a stand of scattered Post Oaks identified on the Southlake 2025 Plan as recommended to be preserved and the applicant is proposing to preserve a majority of the trees within large dividing medians and within open space adjacent to the right-of-way. Street “C” has been repositioned to avoid the stand of trees to the north of it and although Street “L” is proposed to be cut through the trees, less trees are proposed to be removed than when Street “C” was shown cutting through the trees. The applicant has also provided significantly more open space in locations where existing trees are located. This provides for the preservation more trees that provide benefits for the entire community. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. SIDEWALKS: 1. Although it is not required by ordinance, it is recommended that the sidewalks along the R.O.W. be repositioned at a minimum of 8’ from back of curb from the R.O.W. to allow sufficient space for planting street trees on each lot. Case No. Attachment D ZA07-085 Page 3 Case No. ZA07-085 Review No. 4 Dated: 8/29/07 Number of Pages: 2 Project Name: Shady Oaks -- Zoning Change & Concept Plan Contact: Cheryl Taylor, Civil Engineer Phone: (817) 748-8100 Fax: (817) 748-8077 Email: ctaylor@ci.southlake.tx.us The following comments are based on the review of plans received on 8/29/2007. It is the applicant’s responsibility to contact the department representative shown above and make modifications as required by the comment. GENERAL COMMENTS: 1.The Master Thoroughfare Plan shows a 60’ collector street between North Peytonville Avenue and Shady Oaks Drive. The proposed street through the Shady Oaks subdivision does not lay out like a collector street which would connect Peytonville Avenue and Shady Oaks Drive. Instead, the layout is of a local, residential street which would not allow collector functionality with so many residential lots fronting on it. 2.The proposed layout does not match the Master Thoroughfare Plan which shows a collector street that is aligned along the north side of the school tract. 3.The phasing lines indicate that the collector street will be constructed in phases. Recommend constructing entire collector street with the first phase of construction. 4. Typical street cross-sections should not be included on the preliminary plat. 5.Additional comments may be forthcoming with the review of the TIA for this development. 6. Provide all necessary easements for water, sanitary sewer and drainage. Easements shall be 15’ minimum and located on one lot – not centered on the property line. A minimum 20’ easement is required if both storm sewer and sanitary sewer will be located within the easement. Revise easements accordingly. * The 232’ offset from the proposed collector street to Woodbrook in Cross Timber Hills exceeds the City’s minimum requirement for an offset. * Sight distances will be required to conform to AASHTO guidelines on adjacent collectors and arterials. * Use the City of Southlake GPS monuments whenever possible. WATER AND SANITARY SEWER COMMENTS: 1.Provide a hydrant at the end of the water line at the southwest corner of the development rather than a blow off at the end of the line. 2.The feasibility of the connection of the proposed sanitary sewer to the existing 8” gravity line to the south will need to be further evaluated to determine if there is existing capacity downstream to handle the flows from this 96 acre development. * For single family residences, hydrants shall be spaced a maximum of 400 linear feet apart for unsprinklered and 600 linear feet for sprinklered residences. * Water and sanitary sewer lines cannot cross property lines without being in an easement or ROW (15’ minimum). * Water meters and fire hydrants shall be located in an easement or in the ROW. * Water and sanitary sewer lines shall be located in the parkway - not under pavement, except for crossings. * All water and sanitary sewer lines in easements or in the ROW must be constructed to City standards. Case No. Attachment D ZA07-085 Page 4 DRAINAGE COMMENTS: * Detention is not shown for the portion of the development south of the proposed collector street. The connection of the proposed storm sewer system to existing off-site systems will be further evaluated when the final engineering design and calculations are submitted. * The difference between pre and post development runoff shall be captured in the detention pond(s). The proposed detention ponds shall control the discharge of the 5, 10 and 100 year storm events. * Verify that the size, shape, and/or location of the detention pond, as depicted on the concept plan, will be adequate to meet the detention requirements. Any changes to the size, shape, and/or location of the proposed pond(s) may require a revision to the concept plan and may need to be approved by the Planning and Zoning Commission and the City Council. * This property drains into Critical Drainage Structures #7, 8, 10 and 20 and requires a fee to be paid prior to beginning construction. * The discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance # 605. INFORMATIONAL COMMENTS: * Submit civil construction plans (22” X 34” full size sheets) and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website. * A ROW permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City’s sewer, water or storm sewer system. * A Developer’s Agreement will be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be approved by Public Works prior to placing the Developer’s Agreement on the City Council agenda for consideration. * Any hazardous waste being discharged must be pretreated Ordinance No. 836. * This review is preliminary. Additional requirements may be necessary with the review of construction plans. *=Denotes informational comment. Case No. Attachment D ZA07-085 Page 5 COMPREHENSIVE PLAN REVIEW SUMMARY ZA07-085 & 086Two8/3/07 Case No: Review No.: Date of Review: Project: Shady Oaks Application Type: Zoning Change/Concept Plan and Preliminary Plat Contact: Jenny Crosby Phone: (817) 748-8195 Email: jcrosby@ci.southlake.tx.us Consolidated Land Use Plan Recommendations The underlying land use designation is Medium Density Residential and the optional land use designation is Rural Conservation. The proposed development is consistent with the Medium Density Residential designation. Environmental Resource Protection Recommendations The Environmental Resource Protection (ERP) Plan recommends preserving trees whenever feasible. Specifically, the ERP map identifies a portion of this property as a priority area for preservation: The applicant has shown the ERP preservation area on the Tree Conservation Plan and the majority of the trees in the preservation area will be saved. Across the entire site, the majority of the existing trees will be saved. However, staff recommends that the applicant consider the use of the Rural Conservation Subdivision (RCS) zoning district or R-PUD zoning district to preserve trees on the site. Case No. Attachment D ZA07-085 Page 6 Mobility & Master Thoroughfare Plan Recommendations The Mobility & Master Thoroughfare Plan calls for a 60 foot 2 lane east-west collector across this property. The applicant is proposing a residential street instead of the recommended collector. Staff recommends realigning the through street so as to minimize the number of residential lots fronting on it. Southlake Pathways Plan Recommendations An 8 foot east-west trail is required across this property, per the Pathways Plan. This trail is shown on the proposed plan on the north side of Street A, the west side of Street B, and the south side of Street C. A 6 foot sidewalk is required on the east side of Peytonville Avenue, per the Pathways Plan. This sidewalk is shown on the proposed plan. Sidewalks (4 foot minimum) are required on both sides of all streets per the Subdivision Ordinance. These sidewalks are shown on the proposed plan. Additional Comments If entry feature signs are proposed that do not comply with the city’s Sign Ordinance, a sign variance may be requested in conjunction with the zoning & concept plan request. Scaled and dimensioned sign drawings must be received a minimum of 3 weeks prior to the anticipated City Council meeting in order to be considered with the zoning & concept plan. If sign drawings are not provided, a sign variance may be requested at a later date. However, a completed sign variance application and non-refundable application fee ($250) will be required. L:\MEETINGS\DRC\REVIEWS\COMP PLAN\2007\ZA07-085 SHADY OAKS 2007-08-03.DOC Case No. Attachment D ZA07-085 Page 7 Surrounding Property Owners Shady Oaks SPO # Owner Zoning Land Use Acreage 1. Low Density Residential Whitt, Gary Etux Rhonda SF1-A 2.407 2. Low Density Residential Long, Gary C Etux Robin SF1-A 3.909 3. Low Density Residential Heath, Douglas A Etux Kathryn SF1-A 0.951 4. Low Density Residential Moody, Gloria SF1-A 1.023 5. Low Density Residential Dicesare, Diana L Etvir Jon W SF1-A 0.887 6. Low Density Residential Dunlap, W Gary Etux Barbara SF1-A 0.976 7. Low Density Residential Bales, David M SF1-A 0.986 8. Low Density Residential Anderson, Douglas R Etux Janet SF1-A 1.106 9. Low Density Residential McNeil, Charles A Etux Marta S SF1-A 1.034 10.Low Density Residential Shy, Perry Etux Linda SF1-A 0.941 11.Low Density Residential Berg, Nolan I Etux Tara L SF1-A 0.934 12.Medium Density Residential Devoe, David D SF20A 0.463 13.Medium Density Residential Brett, Brian E Etux Suzanne R SF20A 0.45 14.Medium Density Residential Condensa, Gary A SF20A 0.473 15.Medium Density Residential Hendricks, J C Etux Elizabeth SF20A 0.528 16.Medium Density Residential Modi, Elesh H Etux Sabrina SF20A 0.467 17.Medium Density Residential Riggs, Steven N & Teresa Belle SF20A 0.445 18.Medium Density Residential Clayton, Douglas & Alicia SF20A 0.452 Case No. Attachment E ZA07-085 Page 1 19.Medium Density Residential Perera, Rajeev C Etux Sumudu R SF20A 0.454 20.Medium Density Residential Kirby, Jeffrie C Etux Nancy C SF20A 0.456 21.Medium Density Residential Hixson, Charles O Etux Susan M SF20A 0.462 22.Medium Density Residential Strother, Joe P Etux Amy L SF20A 0.544 23.Medium Density Residential Longwell, Jerrold Etux Joyce SF20A 0.455 24.Medium Density Residential Shafi, Shaid Etux Ayesha SF20A 0.457 25.Medium Density Residential Bryant, Thomas M Etux Beverly SF20A 0.505 26.Medium Density Residential Mazzei, Hugh J Etux Maricela Z SF20A 0.455 27.Medium Density Residential Wise, Philip W Etux Anne O SF20A 0.463 28.Medium Density Residential Hubert, Steven & Jean SF20A 0.464 29.Medium Density Residential Tough, Thomas H Etux Judith A SF20A 0.461 30.Medium Density Residential Johnston, David L Etux Elizabe SF20A 0.672 31.Medium Density Residential Vaccaro, Anthony Jr Etux K SF20A 0.672 32.Medium Density Residential Schroeder, Raymond & Amy Mills SF20A 0.479 33.Medium Density Residential Joyce, Mark E SF20A 0.498 34.Low Density Residential Marks, William M Etux Jill Y SF1-A 2.33286704 35.Public/Semi-Public Carroll ISD CS 28.98 36.Low Density Residential Willard, John E Etux Maureen RPUD 0.767 37.Low Density Residential Johnson, Casey Etux Leslie RPUD 0.778 38.Low Density Residential Packard, Matthew W Etux Michel RPUD 0.784 39.Low Density Residential Reynolds, Gary E Etux Deborah RPUD 0.768 40.Low Density Residential Williams, Robert D Etux Kari D RPUD 0.788 41.Low Density Residential Laubenthal, Thomas J & Jean RPUD 0.795 42.Low Density Residential Cummings, John D RPUD 1.056 43.Low Density Residential Nolan, Katherine Etvir James L RPUD 1.086 44.Low Density Residential Duval, Clinton Etux Deborah RPUD 1.873 45.Low Density Residential Coventry Manr Homeowner's Asso RPUD 1.969 46.Low Density Residential Coventry Manr Homeowner's Asso RPUD 1.551 47.Low Density Residential Gorman, Paul R Etux Leslie Y SF1-A 1.092 48.Low Density Residential Palla, Ronald R Etux Marsha SF1-A 1.028 49.Low Density Residential Robinson, Donna B SF1-A 1.122 50.Low Density Residential Chwa, Richard SF1-A 1.086 51.Low Density Residential Miller, John & Cynthia Hanking SF1-A 1.103 52.Low Density Residential Lee, Champ A Etux Joyce SF1-A 1.08 53.Low Density Residential Leftwich, Thomas M Etux Kathy SF1-A 1.908 54.Low Density Residential Gallaway, Richard & Rita SF1-A 1.127 55.Low Density Residential Runyan, Billy W Etux Betty AG 0.987 56.Low Density Residential Hamilton, Ronald L AG 1.491 57.Low Density Residential Russell, Ann AG 1.546 58.Low Density Residential Kemins, Robert A Etux Marie A AG 0.52 59.Low Density Residential Fleps, John J Etux Petronella AG 1.723 60.Low Density Residential Hardy, Monty Etux Linda AG 1.128 61.Low Density Residential Fleps, John J Etux Petronella AG 1.085 62.Medium Density Residential McDonald, Beverly G AG 2.059 Case No. Attachment E ZA07-085 Page 2 63.Medium Density Residential Shady Oaks Ranch Ltd AG 17.462 64.Medium Density Residential Scherer, Hugh C AG 0.893 65.Medium Density Residential Robinson, Wendy M AG 0.524 66.Medium Density Residential Johnson, Arnold Jr Etux Ellen AG 0.487 67.Medium Density Residential Carroll ISD AG 2.04 68.Medium Density Residential Carroll ISD AG 2.207 69.Medium Density Residential Carroll ISD AG 1.816 70.Medium Density Residential Carroll ISD AG 1.233 71.Medium Density Residential Carroll ISD AG 16.01 72.Medium Density Residential Clow, John L AG 1.067 73.Medium Density Residential Shady Oaks Ranch Ltd AG 34.712 74.Medium Density Residential Shady Oaks Ranch Ltd AG 17.964 75.Medium Density Residential Swirczynski, Virgil L Etux Ann AG 1.022 Case No. Attachment E ZA07-085 Page 3 Surrounding Property Owner Responses Shady Oaks Notices Sent: Seventy-five (75). WITHIN 200 FEET Responses Receive: In Favor: Two (2) Opposed: Thirteen (13) Undecided: One (1) OUTSIDE 200 FEET In Favor: One (1) IN FAVOR WITHIN 200 FEET  Douglas & Janet Anderson (SPO #8), 901 Raven Bend Court, submitted a Notification Response Favor Form in on August 7, 2007 (see attached).  Ann Russell (SPO #57), 1049 N Shady Oak Drive, submitted a Notification Response Form in Favor on August 7, 2007 (see attached). OPPOSED WITHIN 200 FEET  Gary & Rhonda Whitt (SPO #1), 1225 N Peytonville Ave., submitted a Notification Response Opposition Form in on July 30, 2007 (see attached).  David & Elizabeth Johnston (SPO #30), 1101 Travis Court, submitted a Notification Response Opposition Form in on August 6, 2007 (see attached).  Charles & Marta McNeil (SPO #9), 905 Raven Bend Court, submitted a Notification Response Opposition Form in on August 6, 2007 (see attached).  Tom & Judy Tough (SPO #29), 1103 Travis Court, submitted a Notification Response Form in Opposition on August 7, 2007 (see attached).  Anthony & Keirstin Vaccaro (SPO #31), 1100 Travis Court, submitted a Notification Response Opposition Form in on August 7, 2007 (see attached).  John & Diana Dicesare (SPO #5), 1000 Raven Bend Court, submitted a Notification Response Opposition Form in on August 7, 2007 (see attached).  Monty & Linda Hardy (SPO #60), 1100 N Shady Oak Drive, submitted a Notification Response Opposition Form in on August 7, 2007  JC & Elizabeth Hendricks (SPO #15), 602 Loving Court, submitted a Notification Response Opposition Form in on August 7, 2007 (see attached).  Elesh & Sabrina Modi (SPO #16), 604 Loving Court, submitted a Notification Response Form in Opposition on August 9, 2007 (see attached).  Hugh & Maricela Mazzei (SPO #26), 906 Brazos Dr, submitted a Notification Response Form in Opposition on August 9, 2007 (see attached).  Beverly McDonald (SPO #62), 587 Shady Oaks Drive, submitted a Notification Response Form Opposition in on August 9, 2007 (see attached 2 pages).  Hugh Scherer (SPO #64), 620 N Shady Oak Drive, submitted a Notification Response Form in Case No. Attachment F ZA07-085 Page 1 Opposition on August 9, 2007 (see attached).  Steven & Teresa Riggs (SPO #17), 606 Loving Court, submitted a Notification Response Form On July 26, 2007 stating Undecided, o Opposition On August 23, 2007 a second Notification Response Form in (see attached). o UNDECIDED WITHIN 200 FEET  Billy & Betty Runyan (SPO #55), 979 N Shady Oaks Drive, submitted a Notification Response Undecided Form stating on August 7, 2007 (see attached). OUTSIDE 200 FEET  Stephen & Ann Bailey, Favor 709 Edwards Court, submitted an E-Mail in on August 23, 2007 (see attached). Case No. Attachment F ZA07-085 Page 2 Responses in Favor Case No. Attachment F ZA07-085 Page 3 Case No. Attachment F ZA07-085 Page 4 Responses in Opposition Case No. Attachment F ZA07-085 Page 5 Case No. Attachment F ZA07-085 Page 6 Case No. Attachment F ZA07-085 Page 7 Case No. Attachment F ZA07-085 Page 8 Case No. Attachment F ZA07-085 Page 9 Case No. Attachment F ZA07-085 Page 10 Case No. Attachment F ZA07-085 Page 11 Case No. Attachment F ZA07-085 Page 12 Case No. Attachment F ZA07-085 Page 13 Case No. Attachment F ZA07-085 Page 14 Case No. Attachment F ZA07-085 Page 15 Case No. Attachment F ZA07-085 Page 16 Case No. Attachment F ZA07-085 Page 17 Case No. Attachment F ZA07-085 Page 18 Responses stating Undecided Case No. Attachment F ZA07-085 Page 19 Case No. Attachment F ZA07-085 Page 20 OUTSIDE 200 FEET Case No. Attachment F ZA07-085 Page 21 SPIN MEETING REPORT CASE NO. ZA07-085 PROJECT NAME: Shady Oaks SPIN DISTRICT: 13 MEETING DATE: July 9, 2007 at 6:30PM MEETING LOCATION: 1400 MAIN STREET, SOUTHLAKE, TEXAS MEETING ROOMS 3A & 3B TOTAL ATTENDANCE: Approximately Fifty (50)  SPIN REPRESENTATIVE(S) PRESENT: Vic Awtry  APPLICANT(S) PRESENTING: Kosse Maykus  STAFF PRESENT: Planner Clayton Comstock STAFF CONTACT: Clayton Comstock, (817)748-8269; ccomstock@ci.southlake.tx.us APPLICANT PRESENTATION SUMMARY About the Developer  The Terra Land Management family of developers has developed about 16 subdivisions in Southlake, including: Estes Park o Oak Pointe o Sandlin Manor o Clariden Ranch o Property Situation of Proposed Development  97 acres bordered by Coventry (North), Southridge Lakes (South), Shady Oaks Drive, Durham Elementary/Intermediate School (East), Raven Bend (Southwest), Cross Timber Hills, and N. Peytonville Avenue (West) Development Details  Before planning, developer identified existing conditions and cataloged approximately 550 trees on the site  Proposing SF-20A zoning for 136 lots on 97 acres Clowe property = 70 acres o CISD property = approx. 27 acres o CISD property was planned for a middle school  City’s Master Thoroughfare Plan shows a collector street connecting Shady Oaks Dr. and Peytonville Ave. – this development offers that connection  City’s Pathways Plan shows a 8-foot trail planned to connect Peytonville to Shady Oaks – this development offers that connection Case No. Attachment G ZA07-085 Page 1  Development will be built in phases, starting with the northeast corner along Shady Oaks Dr nearest Coventry  Only custom builders will be used QUESTIONS & DISCUSSION Raven Cross Coventry Southridge Lakes Bend Timber Hills DRAINAGE What are you going to do about the drainage into Southridge Lakes? The previous plan QUESTION: showed a drainage detention pond abutting Southridge Lakes lots, where is that and what will happen to that drainage now? What will the pond look like on the north end? QUESTION: Will there be additional drainage on Peytonville as a result of this development? Where will the QUESTIONS: water that leaves the site on Peytonville go? Can you improve the ditches along Peytonville? There is a creek on the east side of Shady Oaks Dr that runs north… do you expect any of this QUESTION: development’s runoff to go into that creek? There is a huge flow of water behind lots 27—29 of Southridge Lakes. Will there be any kind of QUESTION: retaining wall to hold off and capture that water? The City should have a Comprehensive Drainage Plan to address areas like this. CONCERN: DEVELOPMENT Is there a minimum home size? QUESTION: What is your expected price point and how many builders will be used? QUESTION: RESPONSE: $1.3 – $2.0 million homes on approximately $300,000+ lots built by 8—10 builders. What are the setbacks of the properties? What kind of fencing is proposed? QUESTION: This plan is much different from the previous plan. Why has it changed ? QUESTION: What size lots are you proposing ? QUESTION: RESPONSE: The average lot size is approximately 25,000 square feet. The minimum is 20,000 square feet, which is the minimum required under the requested SF-20A zoning district category. What size homes are you proposing ? QUESTION: RESPONSE: Between 5,000 and 6,000 square feet. Will the sidewalk be for public use ? Where will they be placed ? Sidewalks are lacking in this QUESTIONS: area and would be beneficial to get to Durham Elementary & Intermediate School. What is the anticipated schedule of development? Specifically, during which phase will the QUESTION: entire roadway be completed? Case No. Attachment G ZA07-085 Page 2 RESPONSE: The developer hopes to begin infrastructure installation in December 2007 and deliver the first lots April/May 2008. They are planning this to be a 3-5 year project, although Estes Park (similar in size & character) was planned for 6-years and is ahead of schedule. TRAFFIC Won’t this duplicate the problem Coventry has with cut-through traffic? QUESTION: Street alignment on both Peytonville & Shady Oaks. Some residents thought there should be a DEBATE : controlled intersection at Cross Timbers and the entrance to the new development, some thought the entrance should be placed further south. Does this new plan change the entrance of Coventry? QUESTION: RESPONSE: This new plan presented tonight does not change the entrance to Coventry. OTHER How will it affect Durham’s attendance? QUESTION: Who will be mowing the Clowe property in the interim? QUESTION: RESPONSE: As soon as Mr. Clowe is off the property, we (the developer) will be responsible for its mowing. SPIN Meeting Reports are general observations of SPIN Meetings by City staff and SPIN Representatives. The report is neither verbatim nor official meeting minutes; rather it serves to inform elected and appointed officials, City staff, and the public of the issues and questions raised by residents and the general responses made. Responses as summarized in this report should not be taken as guarantees by the applicant. Interested parties are strongly encouraged to follow the case through the Planning and Zoning Commission and final action by City Council. Case No. Attachment G ZA07-085 Page 3 CITY OF SOUTHLAKE, TEXAS ORDINANCE NO. 480-531 AN ORDINANCE AMENDING ORDINANCE NO. 480, AS AMENDED, THE COMPREHENSIVE ZONING ORDINANCE OF THE CITY OF SOUTHLAKE, TEXAS; GRANTING A ZONING CHANGE ON A CERTAIN TRACT OR TRACTS OF LAND WITHIN THE CITY OF SOUTHLAKE, TEXAS BEING LEGALLY DESCRIBED AS TRACTS 11, 11C, 11C2, 11C2A, 11C7, 11D, 11D1, 11E, 11F, AND A PORTION OF LOT 2, SITUATED IN THE T. HOOD SURVEY, ABSTRACT NO. 706, BEING APPROXIMATELY 96.3 ACRES, AND MORE FULLY AND COMPLETELY DESCRIBED IN EXHIBIT “A” FROM “AG” AGRICULTURAL DISTRICT TO “SF-20A” SINGLE FAMILY RESIDENTIAL DISTRICT, AS DEPICTED ON THE APPROVED CONCEPT PLAN ATTACHED HERETO AND INCORPORATED HEREIN AS EXHIBIT “B”, SUBJECT TO THE SPECIFIC REQUIREMENTS CONTAINED IN THIS ORDINANCE; CORRECTING THE OFFICIAL ZONING MAP; PRESERVING ALL OTHER PORTIONS OF THE ZONING ORDINANCE; DETERMINING THAT THE PUBLIC INTEREST, MORALS AND GENERAL WELFARE DEMAND THE ZONING CHANGES AND AMENDMENTS HEREIN MADE; PROVIDING THAT THIS ORDINANCE SHALL BE CUMULATIVE OF ALL ORDINANCES; PROVIDING A SEVERABILITY CLAUSE; PROVIDING FOR A PENALTY FOR VIOLATIONS HEREOF; PROVIDING A SAVINGS CLAUSE; PROVIDING FOR PUBLICATION IN THE OFFICIAL NEWSPAPER; AND PROVIDING AN EFFECTIVE DATE. WHEREAS, the City of Southlake, Texas is a home rule City acting under its Charter adopted by the electorate pursuant to Article XI, Section 5 of the Texas Constitution and Chapter 9 of the Texas Local Government Code; and, WHEREAS, pursuant to Chapter 211 of the Local Government Code, the City has the authority to adopt a comprehensive zoning ordinance and map regulating the location and use of buildings, other structures and land for business, industrial, residential and other purposes, and to amend said ordinance and map for the purpose of promoting the public health, safety, morals and general welfare, all in accordance with a comprehensive plan; and WHEREAS, the hereinafter described property is currently zoned as “AG” Agricultural District under the City’s Comprehensive Zoning Ordinance; and WHEREAS, a change in the zoning classification of said property was requested by a person or Case No. Attachment H ZA07-085 Page 1 corporation having a proprietary interest in said property; and WHEREAS, the City Council of the City of Southlake, Texas, at a public hearing called by the City Council did consider the following factors in making a determination as to whether these changes should be granted or denied: safety of the motoring public and the pedestrians using the facilities in the area immediately surrounding the sites; safety from fire hazards and damages; noise producing elements and glare of the vehicular and stationary lights and effect of such lights on established character of the neighborhood; location, lighting and types of signs and relation of signs to traffic control and adjacent property; street size and adequacy of width for traffic reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood; adequacy of parking as determined by requirements of this ordinance for off- street parking facilities; location of ingress and egress points for parking and off-street loading spaces, and protection of public health by surfacing on all parking areas to control dust; effect on the promotion of health ad the general welfare; effect on light and air; effect on the over-crowding of the land; effect on the concentration of population, and effect on transportation, water, sewerage, schools, parks and other public facilities; and, WHEREAS, the City Council of the City of Southlake, Texas, further considered among other things the character of the districts and their peculiar suitability for particular uses and the view to conserve the value of the buildings, and encourage the most appropriate use of the land throughout this City; and, WHEREAS, the City Council of the City of Southlake, Texas, does find that there is a public necessity for the zoning changes, that the public demands them, that the public interest clearly requires the amendments, and that the zoning changes do not unreasonably invade the rights of those who bought or improved property with reference to the classification which existed at the time their original investment was made; and, WHEREAS, the City Council of the City of Southlake, Texas, does find that the changes in zoning lessen the congestion in the streets, helps secure safety from fire, panic, and other dangers, promotes the health Case No. Attachment H ZA07-085 Page 2 and the general welfare, provides adequate light and air, prevents the over-crowding of land, avoids undue concentration of population, and facilitates the adequate provision of transportation, water, sewerage, schools, parks and other public requirements; and, WHEREAS, the City Council of the City of Southlake, Texas, has determined that there is a necessity and need for the changes in zoning and has also found and determined that there has been a change in the conditions of the property surrounding and in close proximity to the tract or tracts of land requested for a change since the tract or tracts of land were originally classified and therefore feels that the respective changes in zoning classification for the tract or tracts of land are needed, are called for, and are in the best interest of the public at large, the citizens of the city of Southlake, Texas, and helps promote the general health, safety and welfare of the community. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: SECTION 1. That Ordinance No. 480, the Comprehensive Zoning Ordinance of the City of Southlake, Texas, passed on the 19th day of September, 1989, as originally adopted and amended, is hereby amended so that the permitted uses in the hereinafter described areas be altered, changed and amended as shown and described below: Being Tracts 11, 11C, 11C2, 11C2A, 11C7, 11D, 11D1, 11E, 11F, and a portion of Lot 2, situated in the T. Hood Survey, Abstract No. 706, being approximately 96.3 acres, and more fully and completely described in exhibit “A” from “AG” Agricultural District to “SF-20A” Single Family Residential District as depicted on the approved Concept Plan attached hereto and incorporated herein as Exhibit “B,” and subject to the following conditions:: 1. SECTION 2. That the City Manager is hereby directed to correct the Official Zoning map of the City of Southlake, Case No. Attachment H ZA07-085 Page 3 Texas, to reflect the herein changes in zoning. SECTION 3. That in all other respects the use of the tract or tracts of land herein above described shall be subject to all the applicable regulations contained in said Zoning Ordinance and all other applicable and pertinent ordinances for the City of Southlake, Texas. All existing sections, subsections, paragraphs, sentences, words, phrases and definitions of said Zoning Ordinance are not amended hereby, but remain intact and are hereby ratified, verified, and affirmed. SECTION 4. That the zoning regulations and districts as herein established have been made in accordance with the comprehensive plan for the purpose of promoting the health, safety, morals and the general welfare of the community. They have been designed, with respect to both present conditions and the conditions reasonably anticipated to exist in the foreseeable future; to lessen congestion in the streets; to provide adequate light and air; to prevent over-crowding of land; to avoid undue concentration of population; and to facilitate the adequate provision of transportation, water, sewerage, drainage and surface water, parks and other commercial needs and development of the community. They have been made after a full and complete hearing with reasonable consideration among other things of the character of the district and its peculiar suitability for the particular uses and with a view of conserving the value of buildings and encouraging the most appropriate use of land throughout the community. SECTION 5. That this ordinance shall be cumulative of all other ordinances of the City of Southlake, Texas, affecting zoning and shall not repeal any of the provisions of said ordinances except in those instances where provisions of those ordinances are in direct conflict with the provisions of this ordinance. SECTION 6. Case No. Attachment H ZA07-085 Page 4 That the terms and provisions of this ordinance shall be deemed to be severable and that if the validity of the zoning affecting any portion of the tract or tracts of land described herein shall be declared to be invalid, the same shall not affect the validity of the zoning of the balance of said tract or tracts of land described herein. SECTION 7. Any person, firm or corporation who violates, disobeys, omits, neglects or refuses to comply with or who resists the enforcement of any of the provisions of this ordinance shall be fined not more than Two Thousand Dollars ($2,000.00) for each offense. Each day that a violation is permitted to exist shall constitute a separate offense. SECTION 8. All rights and remedies of the City of Southlake are expressly saved as to any and all violations of the provisions of Ordinance No. 480, as amended, or any other ordinances affecting zoning which have accrued at the time of the effective date of this ordinance; and, as to such accrued violations and all pending litigation, both civil and criminal, whether pending in court or not, under such ordinances, same shall not be affected by this ordinance but may be prosecuted until final disposition by the courts. SECTION 9. The City Secretary of the City of Southlake is hereby directed to publish the proposed ordinance or its caption and penalty together with a notice setting out the time and place for a public hearing thereon at least fifteen (15) days before the second reading of this ordinance, and if this ordinance provides for the imposition of any penalty, fine or forfeiture for any violation of any of its provisions, then the City Secretary shall additionally publish this ordinance in the official City newspaper one time within ten (10) days after passage of this ordinance, as required by Section 3.13 of the Charter of the City of Southlake. SECTION 10. This ordinance shall be in full force and effect from and after its passage and publication as required by Case No. Attachment H ZA07-085 Page 5 law, and it is so ordained. PASSED AND APPROVED on the 1st reading the ____ day of _________, 2007. _________________________________ MAYOR ATTEST: _________________________________ CITY SECRETARY PASSED AND APPROVED on the 2nd reading the ____ day of __________, 2007. ________________________________ MAYOR ATTEST: ________________________________ CITY SECRETARY APPROVED AS TO FORM AND LEGALITY: _________________________________ CITY ATTORNEY DATE:___________________________ ADOPTED:_______________________ Case No. Attachment H ZA07-085 Page 6 EFFECTIVE:______________________ Case No. Attachment H ZA07-085 Page 7 EXHIBIT “A” Being Tracts 11, 11C, 11C2, 11C2A, 11C7, 11D, 11D1, 11E, 11F, and a portion of Lot 2, situated in the T. Hood Survey, Abstract No. 706, being approximately 96.3 acres: Case No. Attachment H ZA07-085 Page 8 EXHIBIT “B” Case No. Attachment H ZA07-085 Page 9 Tree Conservation Plan Case No. Attachment H ZA07-085 Page 10 Tree Survey Case No. Attachment H ZA07-085 Page 11 Case No. Attachment H ZA07-085 Page 12 Case No. Attachment H ZA07-085 Page 13 Case No. Attachment H ZA07-085 Page 14 Case No. Attachment H ZA07-085 Page 15 Case No. Attachment H ZA07-085 Page 16