Loading...
Item 4GCity of Southlake Department of Planning & Development Services S T A F F R E P O R T March 28, 2007 ZA07-021 CASE NO: Plat Revision for La Mirada PROJECT: REQUEST: On behalf of St. Emilion Partners, Adams Engineering is requesting approval of a plat revision. The plat revision appears consistent with the approved RPUD zoning, development plan and preliminary plat the exception of any minor comments noted in the attached plat review summary. No variances are requested. Consider plat revision approval ACTION NEEDED: ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information Plat Review Summary No. 1, March 15, 2007 (D) (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses (G) Full Size Plans (for Commission and Council Members Only) STAFF CONTACT: Ken Baker (748-8067) Dennis Killough (748-8072) Case No. ZA07-021 BACKGROUND INFORMATION OWNER: St. Emilion Partners APPLICANT: Adams Engineering PROPERTY SITUATION: 1925 N. Peytonville Avenue LEGAL DESCRIPTION: Lot 1R, Rougemont Addition LAND USE CATEGORY: Low Density Residential with a Rural Conservation overlay option designation. CURRENT ZONING: “RPUD” Residential Planned Unit Development HISTORY: -A preliminary plat was approved by City Council for a single agricultural lot on November 2, 1993. -A final plat was approved by P&Z on December 9, 1993. -City Council approved a change of zoning to “RE” on June 2, 1998. -A change of zoning to “SF-1A” on a portion of the property was approved by City Council on August 4, 1998. -City Council approved a plat revision creating Lots 1R & 2 on July 21, 1998. -City Council approved a zoning change to RPUD, a development plan and preliminary plat on November 7, 2006 TRANSPORTATION Master Thoroughfare Plan ASSESSMENT: The Master Thoroughfare Plan recommends N. Peytonville Avenue to be a 2- lane, undivided collector roadway with 70 feet of right-of-way adjacent to this site. Adequate right-of-way exists for this roadway. The street typology designation for N. Peytonville Avenue is ‘Rural Road’. Existing Area Road Network and Conditions The proposed subdivision will have one (1) street intersecting with N. Peytonville Avenue. Currently, N. Peytonville Avenue is a 2-lane, undivided roadway. The capacity of the existing roadway is approximately 8,400 vehicle trips per day. Under this condition, the roadway would be considered to operate under a level of service ‘D’. Completion of this development will add approximately 86 vehicle trips per day to this section of N. Peytonville Avenue, bringing it to 4,276 vehicle trips per day. Case No. Attachment A ZA07-021 Page 1 May, 2005 traffic counts on N. Peytonville Ave (between Southridge Lakes & W. Dove St) 24hr 2,0602,130 North Bound (NB) () South Bound (SB) () NB 416145 Peak A.M. () 8 – 9 a.m. Peak P.M. () 5:15 – 6:15 p.m. SB 353161 Peak A.M. () Peak P.M. () 7:45 – 8:45 a.m.3:45 – 4:45 p.m. Traffic Impact Use # Lots Vtpd* AM-AM-PM-PM- IN OUT IN OUT Number of Single-Family 7 67 2 4 5 3 Residential Lots *Vehicle Trips Per Day **The AM/PM times represent the number of vehicle trips generated during the peak travel times on N. Peytonville Ave. PATHWAYS MASTER PLAN: The Southlake Pathways Master Plan recommends a 6-foot sidewalk on the east side of N. Peytonville Avenue adjacent to the site. WATER & SEWER: A 12-inch water line exists along the east side of N. Peytonville Avenue and a 6-inch water line exists along the west side of the abandoned Brittain Drive in Brittany Place. An 8-inch sanitary sewer line exists along the west side of N. Peytonville Avenue. TREE PRESERVATION: Approximately 12 trees within the proposed ROW, 5 trees within the detention area and 48 trees within building pads are shown to be removed. Approximately 327 trees are shown to be saved. In addition to the existing trees being preserved, the developer proposes 15 new trees to be installed along the south side of the proposed street. DRAINAGE ANALYSIS: This development drains to the southwest portion of the property into a proposed detention/retention pond which will connect to the storm sewer system in N. Peytonville Avenue. SOUTHLAKE 2025: Land Use Plan Recommendations Underlying Low Density Residential with a Rural Conservation optional designation. P&Z ACTION: March 22, 2007; Approved (6-0) subject to Plat Review Summary No. 1, dated March 15, 2007. STAFF COMMENTS: Attached is Plat Review Summary No. 1, dated March 15, 2007. The plat submitted appears to comply with the controlling development plan and preliminary plat with the exception of any minor comments so noted in the stated plat review summary. N:\Community Development\MEMO\2007cases\07-021PR.doc Case No. Attachment A ZA07-021 Page 1 Case No. Attachment B ZA07-021 Page 1 PLAT REVISION Case No. Attachment C ZA07-021 Page 1 PLAT REVIEW SUMMARY ZA07-021One3/16/07 Case No.: Review No.: Date of Review: Plat Revision - La Mirada Project Name: APPLICANT: St. Emilion Partners, LP ENGINEER: Adams Engineering, Inc. Phil Chaffins Jay Reissig 1504 Brentwood Trial 500 S. Nolen Drive, Suite 550 Southlake, TX 76092 Southlake, TX 76092 Phone: (817) 849-1599 Phone: (817) 329-6990 Fax: (817) 849-1703 Fax: (817) 329-7671 CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 3/15/07 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DENNIS KILLOLUGH AT (817) 748-8072. 1)Show and label the survey line of the T. Beedy and C. Dart Surveys along Peytonville Avenue. Label the survey names and abstract numbers. 2)The following changes are needed with regard to building lines easements & ROW: a)Show a 40’ building line along the south boundary (rear yard) of lots 1-5 and add Lots 1-7 to note number 5. b)Remove the building line shown on Lots 8 & 9. These are “Open Space” lots and are not buildable lots. c)Easements must be provided for water, sewer and/or drainage in compliance with approved construction plans. Although utility easements are required along perimeter boundaries of the subdivision, staff recommends locating the easements along the street frontage and limiting the number to what is necessary to provide utility service to the subdivision. d)Show and label the apparent centerline of North Peytonville Avenue and dimension the distance from the northwest and southwest boundary corners to the centerline and opposite right-of-way line. e)Confirm that the La Mirada Court (add Court to the street name) has been adjusted to the south to save the pecan and oak trees near the entrance according to the City Council approval of the zoning and development plan. Case No. Attachment D ZA07-021 Page 1 INFORMATIONAL COMMENTS * All lots must comply with the underlying zoning district regulations. * A fully corrected plan that includes all associated support plans/documents and conditions of approval is required before any ordinance or zoning verification letter publication or before acceptance of any other associated plans for review. Plans and documents must be reviewed and stamped “approved” by the Planning Department. * All development must comply with the City’s Drainage Ordinance No. 605. * A Developer’s Agreement is required prior to construction of any public infrastructure. The Developer’s Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off-site drainage and utility easements and impact fees. The City Council approved the RPUD zoning and development plan on November 7, 2006 (6-0) including the following amendments: the deletion of Lot 8; moving the road to the south to save a pecan tree and oak tree at the entrance to the property as referenced by the developer; requiring the developer to work with the neighbors as to the location of plantings and height of berms and the locations of the plantings and berms will be determined after construction of the road and be in concurrence with the neighbors; requiring the pergola to have stone columns; the iron fencing will have a minimum of ¾ inch gauge being heavier than what was presented in the pictures with stone columns every 30 feet; requiring no wood fencing; requiring the pond located at the front will be a retention/detention pond; stating that any accessory buildings or sports courts or other improvements will be no closer than 40 feet from the south boundary of the lots and not allowing lights on the sports courts; noting the developer has agreed to deed restrict Lot 7 to prohibit subdivision; not allowing this to be a gated community; and subject to Development Review Summary No. 4, dated November 1, 2006. Case No. Attachment D ZA07-021 Page 1 Surrounding Property Owners La Mirada SPO # Owner Zoning Land Use Acreage Low Density Residential 1. St Emilion Partners Lp RPUD 11.468 Low Density Residential 2. Burckle, Robert A Etux Joan SF1-A 2.82 Case No. Attachment E ZA07-021 Page 1 Surrounding Property Owner Responses La Mirada Notices Sent: Two (2). Responses Receive: None (0). Case No. Attachment F ZA07-021 Page 1