Item 6CItems 6C & 6D
ZA08-078
ZA08-078
Owner/
Applicant: City of Southlake
Request: Approval of a Zoning Change of 6 acres from AG to CS, a master plan for the entire park site, and a site plan for 25 acres (4 ball fields, five tennis courts, concessions,
restroom facility, staff offices, parking and landscaping)
Location: 400 N. White Chapel Blvd.
Master Plan
Staff was asked to investigate the following:
Look at how to buffer the sound of the batting cages;
Reduce the parking spaces by 12 spaces;
Additional plantings and possible fence options in the buffer area on the north side;
Look at operating hours;
Securing of fields and batting cages;
Utilization of lighting option #2;
5’ backboards for the outfield;
Wall options; and
Update on any additional conversations with neighbors.
Variances
Lighting Variance
- Allow halide lighting instead high pressure sodium (ball fields and tennis courts)
Allow maximum intensity to exceed 20 ft candles (max. 70 ft candles)
Allow spill over lighting to exceed 0.2 ft. candles at the residential boundary (22 ft. candles)
Except for Phase 1- the buffer yard will remain as it exists today.
City Council Motion – 1st Reading
October 21, 2008; Approved (5-0) subject to the presentation by staff tonight; granting the requested variances; asking staff to research items that have been listed by Council: confirming
use of evergreen trees where possible along the north boundary of the park; investigating some sort of noise barrier at the batting cages; asking staff to look at wall options (8’ or
10’ wall options ) and make contact with the adjacent landowner to get his input on the wall options; utilizing lighting option #2; asking staff to further look at the operating hours
and work in conjunction with the SBA and other associations and see what operating hours will be set for the park; asking staff to look at security for the ball fields in terms of perhaps
securing the batting cages with the assistance of the SBA; asking staff to look into five-foot backboards on the outfield fences; asking staff to look at the impact of removal of 12
parking spaces as suggested; and subject to Revised Site Plan Review Summary No. 1, dated October 15, 2008.
Plat Revision
Questions?
LUD Map
Zoning District Map
Construction Layout
Landscape Plan
Site Details – Baseball Bleachers
Site Details - Fencing
Site Details - Bridge
Site Details - Roundabout
Site Details – Parking Lot Wall and Stairs
Site Details – Entry Gate and Retaining Wall
Site Details - Flag Plaques
Elevations - Evans House
Elevations – Evans House
Elevations – Concession Building
Elevations - Ticket Booth
Elevations – Entry Monuments
Elevations – Pump House
View Looking East Along East Portion
of the North Boundary
View Looking West Along East Portion
of the North Boundary
View Looking West Along West Portion
of the North Boundary
View Looking West Along West Portion
of the North Boundary
8 ft. Fence
8 ft. Fence
6 ft. Fence
Master Plan