Loading...
Item 7AItem 7A – ZA08-044 Regent’s Professional Park Owner: NADO LTD. Applicant: Blake Architects Request: Zoning Change and Site Plan from “SF-1A” to “S-P-1” for the development of Regent’s Professional Park, an office development of five (5) office buildings totaling 29,570 square feet on 3.54 acres. Location: 2580 & 2530 W. Southlake Blvd. Zoning District Map LU Map W. Southlake Blvd Watermere Jellico Estates Stonebridge River Oaks Jellico Square Davis Blvd Transition from higher intensity retail and office uses near the Southlake Blvd and Davis Blvd intersection to lower intensity office and residential uses adjacent to Jellico Estates Property immediately adjacent to FM1709 may not be suitable for single-family residential development Master planning and site connectivity recommended Continued recommendation of T-1 but apparently was never adopted Southlake 2025 Davis Boulevard Corridor Plan (Area A) PICTOMETRY SITE PLAN CONCEPT PLAN ELEVATION RENDERING SITE PLAN BUILDING ‘A’ ELEVATIONS CONCEPT PLAN ELEVATION RENDERING SITE PLAN BUILDINGS ‘B’ ELEVATIONS CONCEPT PLAN ELEVATION RENDERING SITE PLAN BUILDING ‘C’ ELEVATIONS CONCEPT PLAN ELEVATION RENDERING SITE PLAN BUILDING ‘D’ ELEVATIONS CONCEPT PLAN ELEVATION RENDERING SITE PLAN BUILDING ‘E’ ELEVATIONS CONCEPT PLAN ELEVATION RENDERING SITE PLAN TREE CONSERVATION PLAN CONCEPT PLAN ELEVATION RENDERING SITE PLAN EXISTING GRADE 689 664 CONCEPT PLAN ELEVATION RENDERING SITE PLAN PROPOSED GRADING PLAN 679 679 674 675 670 665 681 CONCEPT PLAN ELEVATION RENDERING SITE PLAN LANDSCAPE PLAN CONCEPT PLAN ELEVATION RENDERING SITE PLAN LANDSCAPE PLAN CANOPY TREES ACCENT TREES Bald Cypress Live Oak Lacebark Elm Existing Tree Wax Myrtle Crape Myrtle Mexican Plum SITE DATA SUMMARY SP1 Regulations Permitted Uses This property shall be limited to the permitted uses as found in the “O-1” Office District of the Comprehensive Zoning Ordinance No. 480, as amended. Development Regulations This property shall be subject to the development regulations for the “O-1” Office District and all other applicable development regulations within the City of Southlake with the following exceptions/modifications: Fencing and screening along the northern and western property lines will be 6’ wrought iron with masonry columns placed twenty-six feet (26’) on center. Bufferyards along interior lot lines shall not be required for this development. One (1) loading space shall be required for the entire development. An overall parking ratio of 1 space per 173 square feet of building area shall be used in calculating required parking for the entire site. As each lot develops individually, the appropriate number of parking spaces will be constructed so that each building provides the required 1:173 ratio. Rear yard, side yard, and front yard setbacks will be allowed as shown on the Site Plan, except that the minimum setback along Southlake Blvd. (FM 1709) shall remain fifty feet (50’) and the minimum setback adjacent to single-family residential property shall remain twenty-five feet (25’). The maximum impervious coverage for any individual lot shall not exceed seventy-six percent (76%) nor shall the impervious coverage for the entire development exceed sixty-five percent (65%). The minimum preservation of existing tree canopy coverage shall be forty percent (30%). Lot 6 (Detention Pond / Open Space) shall be owned and maintained by and through a Property Owners Association. SP1 Regulations VARIANCE REQUEST – MINIMUM DISTANCE TO INTERSECTION Required: 500’ Provided: 348’ SPIN – September 22, 2008 Planning & Zoning Commission – November 6, 2008 Approved (6-1) approving the variance for the minimum distance to an intersection along a roadway; requiring that a stub for cross-connectivity access to property to the west; requiring the applicant to provide a revised landscape plan for placing evergreen coverage on the north west corner of the property; and subject to Site Plan Review Summary No. 5, dated October 31, 2008 Public Review Questions? Public Works CONCEPT PLAN ELEVATION RENDERING SITE PLAN EXISTING GRADE CONCEPT PLAN ELEVATION RENDERING SITE PLAN PROPOSED GRADING PLAN CONCEPT PLAN ELEVATION RENDERING SITE PLAN DRAINAGE PLAN – DEVELOPED CONDITIONS Detention Pond on the River Oaks Property can also serve this development CONCEPT PLAN ELEVATION RENDERING SITE PLAN UTILITY PLAN Existing 8” Dia. Sanitary Sewer Proposed 8” Dia. Sanitary Sewer Existing 12” Dia. Water Line Proposed 12” Dia. Water Line along SL Blvd; Proposed 8” Dia. Water Line looped internally