Loading...
Item 4K Department of Planning & Development Services S T A F F R E P O R T April 30, 2008 ZA08-014 CASE NO: Preliminary Plat for Winfield Estates PROJECT: REQUEST: Carroll Avenue / Dove Road Development is requesting approval of a Preliminary Plat for Winfield Estates—a residential subdivision of 12 residential lots and 1.45 acres of open space. The preliminary plat is consistent with the approved Development Plan. No variances are requested. Consider preliminary plat approval ACTION NEEDED: ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information (D) Plat Review Summary No. 2, dated April 11, 2008 (E) Surrounding Property Owners Map (F) Surrounding Property Owners Responses for Commission and Council Members Only (G) Full Size Plans () STAFF CONTACT: Ken Baker (817)748-8067 Clayton Comstock (817)748-8269 Case No. ZA08-014 BACKGROUND INFORMATION OWNER/APPLICANT: Carroll Avenue / Dove Road Development PROPERTY SITUATION: 1107 and 1155 E. Dove St. and 2210 N. Carroll Ave. The southwest corner of E. Dove St. and N. Carroll Ave. LEGAL DESCRIPTION: Tracts 1, 1C, and 1C1, A.H. Chivers Survey, Abstract No. 299 LAND USE CATEGORY: Low Density and Medium Density Residential with an optional Rural Conservation Overlay designation. CURRENT ZONING: R-PUD Residential Planned Unit Development District HISTORY: A Zoning Change & Development Plan (ZA07-063) was approved by City Council on November 20, 2007. WATER & SEWER:Water: The development will tie into existing 6-inch and 12-inch water lines in N. Carroll Avenue and E. Dove Street. Sewer: The development will tie into an existing 6-inch sanitary sewer line in N. Carroll Avenue. DRAINAGE ANALYSIS:The developer proposes to drain the majority of this site to the provided wet retention pond in the northeast corner of the development. P&Z ACTION: April 17, 2008; Approved (6-0) subject to Plat Review No. 2, dated April 11, 2008. STAFF COMMENTS: Attached is Plat Review No. 2, dated April 11, 2008. N:\Community Development\MEMO\2008cases\014 -PP - Winfield Estates\Staff Report\08-014PP.PZ 4-17.doc Case No. Attachment A ZA08-014 Page 1 Case No. Attachment B ZA08-014 Page 1 APPROVED DEVELOPMENT PLAN Case No. Attachment C ZA08-014 Page 1 PRELIMINARY PLAT Case No. Attachment C ZA08-014 Page 2 PLAT REVIEW SUMMARY ZA08-014Two4/11/08 Case No.: Review No.: Date of Review: Preliminary Plat – Winfield Estates Project Name: APPLICANT: SURVEYOR/ENGINEER: Carroll Ave / Dove Rd Development LLC GSWW, Inc. – Jackie Fluitt 601 Zena Rucker Rd; Ste 107 3950 Fossil Creek Blvd; Ste 210 Southlake, TX 76092 Fort Worth, TX 76137 P: (817)488-9000 P: (817)306-1444 F: (817)488-0819 F: (817)306-1555 3/31/08 CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, CLAYTON COMSTOCK AT (817)748-8269 PLEASE CONTACT . 1. This plat is required to meet the development regulations of the underlying R-PUD zoning district and other applicable regulations set forth in Zoning Ordinance No. 480 and Subdivision Ordinance No. 483, as amended. 2. The following comments are in regard to labeling: a. The entirety of Lot 14 cannot be considered as a drainage easement per the open space dedication requirements per the approved zoning and development plan. Dimension the drainage easement to be utilized for drainage purposes. b. Fully dimension the boundaries of Lot 14. 3. The following changes are needed regarding Right-of-Way dedication on E. Dove Street: a. Label the width of all ROW to be dedicated by this development; provide dimensions of all ROW dedications from property corners b. Dimension all property corners to the centerline of the apparent existing ROW. c. Show and dimension the R.O.W. dedication in accordance with the current Master Thoroughfare Plan. Dimensions must either be from center line of apparent existing R.O.W. or full width from across R.O.W. if opposite side has dedicated their half. * Although there are a few lot lines which are not perpendicular or radial, they appear to meet the intent of this requirement. * A Developers Agreement and FINAL PLAT is required prior to construction of any public infrastructure. The Developer's Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off-site drainage and utility easements and impact fees. * Denotes Informational Comment ENGINEERING REVIEW Case No. Attachment D ZA08-014 Page 1 Contact: Cheryl Taylor, P.E. | (817)748-8100 | ctaylor@ci.southlake.tx.us GENERAL COMMENTS: * The proposed maintenance access easement to the detention pond, as shown, will require the property owner of Lot 11 to construct the fence 3’ from the south property line. The requirement may need to be included in the deed restrictions for the subdivision. * The City’s Water Master Plan indicates that a 12” water line is required along Dove to tie into the existing 12” water line in Carroll. The developer may request reimbursement from the City for the cost of upsizing the water line to meet the Master Plan requirement. * Use the City of Southlake GPS monuments whenever possible. DRAINAGE COMMENTS: * The difference between pre and post development runoff shall be captured in the detention pond. The proposed detention pond outlet shall control the outfall for the 2, 10 and 100 year storm events. Please note: the previous requirement was control of the 5, 10 and 100. * Note: Any changes to the size, shape, and/or location of the proposed pond(s) may require a revision to the concept/site/development plan and may need to be approved by the Planning and Zoning Commission and the City Council. * There is no Critical Drainage Structure fee associated with this development. * The discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance # 605. INFORMATIONAL COMMENTS: * Submit civil construction plans (22” X 34” full size sheets) and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website. * A ROW permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City’s sewer, water or storm sewer system. * A Developer’s Agreement will be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be approved by Public Works prior to placing the Developer’s Agreement on the City Council agenda for consideration. * Any hazardous waste being discharged must be pretreated Ordinance No. 836. * This review is preliminary. Additional requirements may be necessary with the review of construction plans. *=Denotes informational comment. LANDSCAPE ADMINISTRATOR REVIEW Contact: Keith Martin | (817)748-8229 | kmartin@ci.southlake.tx.us TREE CONSERVATION COMMENTS: * There are two additional trees proposed to be preserved on the submitted Tree Conservation than there are on the approved Concept Plan / Tree Conservation Plan. Case No. Attachment D ZA08-014 Page 2 Surrounding Property Owners Winfield Estates SPO # Owner Zoning Land Use Acreage 1. Medium Density Residential Gist, Greg L O1 1.28 2. Medium Density Residential Tuscany American Homes Inc RPUD 0.63 3. Medium Density Residential Gray, Vince P RPUD 0.82 4. Medium Density Residential Wood, Steve Neil RPUD 0.77 5. Medium Density Residential Carney, Max Etux Nicole RPUD 0.74 6. Medium Density Residential Garcia, Anthony Etux Donna RPUD 0.62 7. Medium Density Residential Depperman, Chris Etx Tracey RPUD 0.63 8. Medium Density Residential Estes Park Hoa RPUD 1.54 9. Low Density Residential Martinez, Keith A Etux Deborah SF1-A 1.34 10. Public / Semi-Public Carroll ISD CS 28.22 11. Low Density Residential Anderson, Steven Etux Cheryl SF1-A 1.99 12. Low Density Residential Miller, Michael Etux Cynthia SF1-A 2.35 13. Medium Density Residential Mlwilson I Ltd RPUD 4.30 14. Medium Density Residential Barnes, David Clifton AG 0.97 15. Low Density Residential Guest, Mark Timothy RPUD 2.90 16. Low Density Residential Ml Wilson I Ltd RPUD 1.94 17. Public / Semi-Public Priddy, David Joe CS 0.13 18. Low Density Residential Hall, Harvey E Etux Sarah D AG 1.47 19. Low Density Residential Mills, Jerry & Kim SF20B 0.44 20. Low Density Residential Alan Kay Custom Homes Llc AG 5.08 Case No. Attachment E ZA08-014 Page 1 Surrounding Property Owner Responses Winfield Estates Notices Sent: Twenty (20) Responses Received: None (0) Case No. Attachment F ZA08-014 Page 1