Loading...
Item 6F Department of Planning & Development Services S T A F F R E P O R T April 9, 2008 ZA07-159 CASE NO: Plat Showing for Lots 4 & 5, Stratfort Gardens PROJECT: REQUEST:Terra/Stratfort Office is requesting approval of a plat showing for two lots on 2.18 acres. Although this property was originally part of the Stratfort Gardens preliminary plat, the proposed subdivision is not consistent with the approved preliminary plat. The preliminary plat showed one lot for this property instead of two. For this reason, the applicant has submitted a plat showing rather than a final plat. The applicant is requesting the following variance:  Street Frontage – The applicant is requesting a variance to the street frontage requirements for Lot 4. Consider plat showing approval ACTION NEEDED: ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plans and Support Information Plat Review Summary No. 4, dated April 9, 2008 (D) for Commission and Council Members Only (E) Full Size Plans () STAFF CONTACT: Ken Baker (748-8067) Jennifer Crosby (748-8195) Case No. ZA07-159 BACKGROUND INFORMATION OWNER/APPLICANT: Terra/Stratfort Office PROPERTY SITUATION: 425 W. Southlake Boulevard LEGAL DESCRIPTION: Tract 3A, H. Granberry Survey, Abstract No. 581 LAND USE CATEGORY: Office Commericial CURRENT ZONING: C-2 Local Retail Commercial District HISTORY: The property was zoned “C-2” Local Retail Commercial District when the city adopted Zoning Ordinance No. 480. A preliminary plat for the entire Stratfort Gardens (aka The Gardens at Stratfort Parc) development was approved on September 20, 2006. However, the subject property was not included in the final plat for Stratfort Gardens. WATER & SEWER: There are existing 8-inch and 10-inch diameter sewer lines located west of the property which may serve this development. There is an existing 12-inch diameter water line located north of the property along the south side of FM 1709 which can serve this development. DRAINAGE ANALYSIS: Drainage from this site is generally to the west to the existing channel between the Lake Crest subdivision and the Gardens of Stratfort Parc subdivision. TREE PRESERVATION: There are five (5) existing trees naturally growing on the site and they are proposed to be removed. All of the trees are in poor shape and have grown up through and between the trash and structure on the lot. The other existing trees were planted during the development and construction of the Gardens of Stratfort Park subdivision and will be preserved. P&Z ACTION: April 3, 2008; Approved (6-0), granting the street frontage variance and subject to Plat Review Summary No. 3, dated February 29, 2008. STAFF COMMENTS: Attached is Plat Review Summary No. 3, dated February 29, 2008. N:\Community Development\MEMO\2007cases\07-159PS.doc Case No. Attachment A ZA07-159 Page 1 Case No. Attachment B ZA07-159 Page 1 Link to PowerPoint Presentation Case No. Attachment C ZA07-159 Page 1 PLAT REVIEW SUMMARY ZA07-159Four4/9/08 Case No.: Review No.: Date of Review: Plat Showing – Lots 4-5, Block 2, Stratfort Gardens Project Name: APPLICANT: Clayton Redinger OWNER: Kosse Maykus DeOtt inc. Terra/Stratfort Office L.P. 2553 East Loop 820 North 395 W. Northwest Parkway #200 Southlake, TX 76092 Phone: 817-589-0000 Phone: 817-329-3111 Fax: 817-590-8600 Fax: 817-329-3854 claytonredinger@deotte.com kosse@maykus.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 4/9/08 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT Jenny Crosby AT (817) 748-8195. 1)POB must be tied to a survey corner or previously filed subdivision corner. 2)Provide a common access easement over driveway and stubbing into the eastern boundary of the property. 3)Lot 4 requires a variance to the street frontage requirements. Applicant proposes frontage on a CAE meeting city street and fire standards. Please submit a variance request letter. 4)A Plat Showing of 4 or fewer lots shall bear the name of the original survey and abstract number. Applicant has requested not to follow traditional naming convention and to use the name of the adjacent subdivision, Stratfort Gardens. Since this property was originally part of the Stratfort Gardens preliminary plat, staff does not have any concerns with the proposed name. 5)Provide easements for water, sewer, and/or drainage in compliance with approved construction plans. INFORMATIONAL COMMENTS * A reciprocal access and parking agreement will be required prior to filing the plat and before a building permit is issued. The agreement should include maintenance of the CAE, use of parking spaces, common trash enclosures, and common landscape areas. * Completely corrected preliminary water, sewer and drainage plans are required with the submittal of a final plat. Staff does not recommend approval of this plat without submittal and review of the required preliminary engineering plans. * A “Certificate of Taxes Paid” indicating that there are no delinquent taxes owed on the subject property from each taxing authority must be provided to the City prior to filing this plat in the County records. A copy of this information may be obtained from the Tarrant county Tax Assessor/Collector’s Office located at 100 E. Weatherford St. in Ft. Worth (across from the old red courthouse). There is a service Case No. Attachment D ZA07-159 Page 1 charge of $10 per account for this certificate. For more information contact the Assessor/Collector’s office at (817) 884-1103. blackline * Original signatures and seals will be required three mylars prior to filing the plat. Also required are two sets of owner's dedications and notaries (8.5" x 11" or 14" paper) with original signatures and seals on each. Mylars will not be accepted if any erasures or original ink, other than signatures or seals, appear on the plat. Please submit a revised blueline "check print" prior to submitting blackline mylars with original signatures. * A Developers Agreement is required prior to construction of any public infrastructure. The Developer's Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off-site drainage and utility easements and impact fees. Case No. Attachment D ZA07-159 Page 2 Case No. ZA07-159 Review No. 4 Dated: 4/9/08 Number of Pages: 2 Project Name: Stratfort Gardens Commercial Park -- Plat Showing Contact: Cheryl Taylor, Civil Engineer Phone: (817) 748-8100 Fax: (817) 748-8077 Email: ctaylor@ci.southlake.tx.us The following comments are based on the review of plans received on 4/9/08 It is the applicant’s responsibility to contact the department representative shown above and make modifications as required by the comment. GENERAL COMMENTS: * Steps may be required to connect the proposed sidewalks into the existing sidewalk along FM 1709 due to the change in grade. * Provide all necessary easements for water, sanitary sewer and drainage. Easements shall be 15’ minimum and located on one lot – not centered on the property line. * Use the City of Southlake GPS monuments whenever possible. WATER AND SANITARY SEWER COMMENTS: * There are existing 8-inch and 10-inch diameter sewer lines located west of the property which may serve this development. * There is an existing 12-inch diameter water line located north of the property along the south side of FM 1709 which can serve this development. DRAINAGE COMMENTS: 1.The note on the drainage plan indicates that no detention is required, per the ‘Preliminary Drainage Plan.’ ‘Preliminary’ drainage plans are not typically detailed enough to sufficiently determine the necessity for detention on a proposed development. Revise drainage note accordingly. 2.The concrete flume appears to convey storm water from the offsite area to the west of this development. A minimum 15’ easement will be required. * Drainage from this site is generally to the west to the existing channel between the Lake Crest subdivision and the Gardens of Stratfort Parc subdivision. * This property drains into Critical Drainage Structure #20 and will require a fee of $467.15 (2.18 acre * 214.29/acre) fee to be paid prior to beginning construction. * The discharge of post development runoff must have no adverse impact on downstream properties and meet the provisions of Ordinance # 605. INFORMATIONAL COMMENTS: * Submit civil construction plans (22” X 34” full size sheets) and a completed Construction Plan Checklist directly to the Public Works Administration Department for review. The plans shall conform to the most recent construction plan checklist, standard details and general notes which are located on the City’s website. * An access permit form TxDOT is required prior to construction or re-construction of a driveway on FM 1709, FM 1938, or SH 114. Submit application and plans directly to TxDOT for review. * A ROW permit shall be obtained from the Public Works Operations Department (817) 748-8082 to connect to the City’s sewer, water or storm sewer system. Case No. Attachment D ZA07-159 Page 3 * A Developer’s Agreement may be required for this development and may need to be approved by the City Council prior to any construction of public infrastructure. Construction plans for these improvements must be acceptable to Public Works prior to placing the Developer’s Agreement on the City Council agenda for consideration. * Any hazardous waste being discharged must be pretreated Ordinance No. 836. * This review is preliminary. Additional requirements may be necessary with the review of construction plans. *=Denotes informational comment. Case No. Attachment D ZA07-159 Page 4