Loading...
Item 4B - Staff Report Item 413 13 CITY OF D SOUTHLAI<,,E epartment of Planning & Development Services STAFF REPORT November 6, 2026 CASE NO: ZA26-0072 PROJECT: Plat Revision for Bridlegate EXECUTIVE SUMMARY: Spry Surveyors, on behalf of Frank Viola and Christopher Lamon, is requesting approval of a Plat Revision for Bridlegate, on property described as Lot 2R, R.D. Price No. 992 Addition and located at 4000 N. White Chapel Boulevard. Applicant: Spry Surveyors. Property Owner: Frank Viola and Christopher Lamon. Current Zoning: "SF-1A" Single Family Residential District. SPIN Neighborhood #1. DETAILS: The purpose of this request is to seek approval of a Plat Revision to subdivide approximately 9.562 acres into eight residential lots and common area lot, identified as Lots 1-8 and 9X, Block 1, Bridlegate Addition. The proposed plat revises Lot 2R, R.D. Price No. 992 Addition, and is consistent with the approved Revised Concept Plan (ZA26-0040) and Preliminary Plat (ZA26- 0060). ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Approval of a Plat Revision ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plat Revision Review Summary No. 1, dated October 30, 2026 (D) Surrounding Property Owners Map and Responses PowerPoint Presentation Plans STAFF CONTACT: Dennis Killough (817) 748-8072 Cyndi Cheng (817) 748-8269 Case No. ZA26-0072 BACKGROUND INFORMATION OWNER: Frank Viola and Christopher Lamon APPLICANT: Spry Surveyors PROPERTY SITUATION: 4000 N. White Chapel Blvd LEGAL DESCRIPTION: Lot 2R, R.D. Price No. 992 Addition, City of Southlake, Tarrant County, Texas. LAND USE CATEGORY: Low Density Residential CURRENT ZONING: "SF-1X Single Family Residential District HISTORY: - The property was annexed into the City in 1988. - The existing residential home was built in 1999. - On March 5, 2002, City Council approved a zoning change from "RE" Single Family Residential Estate District to "SF-1X Single Family Residential District (ZA01-138). - The existing accessory structure was built in 2010. The barn was approved by SEU through the Zoning Board of Adjustment (ZBA). - On September 16, 2014, City Council approved a Zoning Change and Concept Plan (ZA14-093), running concurrently with a Preliminary Plat and Plat Revision, to combine the unplatted Tract 14 and a portion of Tract 15, which totaled approximately 4.6 acres, with Lot 2, R.D. Price No. 992 Addition, to create one lot approximately 9.562 acres in size, designated as Lot 2R, and to approve a variance to allow a double-fronted residential lot. Approval of both plats was subject to approval of the Zoning Change and Concept Plan. - On September 16, 2014, City Council approved a Preliminary Plat for Lots 2R and 6, R.D. Price No. 992 Addition, as well as a Plat Revision for Lot 2R, including approval of a variance to allow a double fronted residential lot (ZA14-094 and ZA14-095). Approval of both plats was subject to approval of the associated Zoning Change and Concept Plan noted above. - The Plat Revision for the property was recorded on September 1, 2015. - On August 4, 2026, City Council approved a revised Concept Plan, noting the concept plan is for eight (8) single family residential lots and approving variances for a private street with gate access and a residential driveway off of a collector street being W. Bob Jones Road for Lot 6 only and requiring that Case No. Attachment A ZA26-0072 Page 1 drainage for the detention pond on Lot 6 be directed 100% to the south and then east to west, staying entirely on the property along the north border of Lots 5 and 7 to White Chapel Boulevard (ZA26-0040). On October 6, 2026, City Council approved a Preliminary Plat (ZA26-0060). SOUTHLAKE COMPREHENSIVE PLAN: Consolidated Future Land Use Plan The future land use designation for the site is Low Density Residential. Low Density Residential Purpose and Definition: The purpose of the Low-Density Residential land use category is to provide for and to protect low intensity detached single-family residential development that promotes the openness and rural character of Southlake. The Low Density Residential category is for detached single-family residential development at a net density of one or fewer dwelling units per acre. Net density is the number of dwelling units per net acre, which excludes acreage in all rights-of-way, easement, and lots designated for public or private streets. Other suitable activities are those permitted in the Public Parks / Open Space and Public/ Semi-Public categories. The Low Density Residential category encourages the openness and rural character of the City of Southlake. Mobility & Master Thorouqhfare Plan The Master Thoroughfare Plan designates N. White Chapel a 70-foot undivided two-lane collector (C2U) and W. Bob Jones Road is a 60-foot undivided two-lane collector (C2U). The Master Pathways Plan calls for a minimum 5-foot future sidewalk on N. White Chapel Boulevard an equestrian/hiking trail on W. Bob Jones Road. Equestrian/hike trails are pathways that may vary in width depending on site conditions and user needs. They are preferred to be natural surface for hiking and/or horseback riding but may be concrete or asphalt depending on site conditions. The adjacent development to the east (Rainey Court) provided a sidewalk. The approved concept plan shows a sidewalk along W. Bob Jones Road and N. White Chapel Boulevard. In addition, sidewalks are required on both sides of public and private streets in residential neighborhoods. The concept plan shows sidewalks along both sides of the internal street. DRAINAGE: A small portion of the site drains toward W. Bob Jones and the remainder of the site drains to the southeast toward N. White Chapel. The proposed development is routing runoff from Lot 6 into the detention pond rather than toward the east onto the Rainey Court subdivision, and is capturing a majority of the site within storm drain pipe routing the drainage flow to two detention ponds. One pond will be located on the south end of Lot 6 and the other along the N. White Chapel frontage of Lot 8. Case No. Attachment A ZA26-0072 Page 2 PLANNING AND ZONING COMMISSION ACTION: November 5, 2026; Approved (5-0) subject to the Staff Report, dated October 30, 2026 and Plat Revision Summary No. 1, dated October 30, 2026, as presented. STAFF COMMENTS: Attached is Plat Revision Review Summary No. 1, dated October 30, 2026. Case No. Attachment A ZA26-0072 Page 3 Vicinity Map 4000 N White Chapel Blvd .' ' pg] NEB , AA ti } LU V. .1:.. " i�,. ' of ° , F 4 QMiles %J r.:k cw ZA26-0072 Case No. Attachment B ZA26-0072 Page 4 PLAT REVISION REVIEW SUMMARY Case No.: ZA26-0072 Review No.: One Date of Review: 10/30/26 Project Name: Plat Revision - Bridlegate APPLICANT: Spry Surveyors SURVEYOR/ENGINEER: David Lewis Frank Viola & Christopher Lamon 8241 Mid-Cities Blvd., Ste. 102 192 Bass Ridge North Richland Hills, TX 76182 Southlake, TX 76092 CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 10/12/26 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT CYNDI CHENG AT (817) 748-8269. The following changes are needed according to the Subdivision Ordinance, as amended, Sections 3.01, 3.03, & 8.01. 1. Place the City case number "ZA26-0072" in the lower right-hand corner of the plat. The following is to be noted according to the Subdivision Ordinance, as amended, Sections 3.03, 8.01, and Zoning Ordinance Section 6.5. 2. Creation of nonconforming structures via platting is prohibited. Any existing structures that would become nonconforming as a result of the proposed plat must be demolished prior to plat approval and building permit issuance. On August 4, 2026, City Council approved a revised Concept Plan, noting the concept plan is for eight (8) single family residential lots and approving variances for a private street with gate access and a residential driveway off of a collector street being W. Bob Jones Road for Lot 6 only and requiring that drainage for the detention pond on Lot 6 be directed 100% to the south and then east to west, staying entirely on the property along the north border of Lots 5 and 7 to White Chapel Boulevard. Provide sidewalks and/or trails in compliance with the Subdivision Ordinance No. 483, as amended and the Master Pathways Plan. Tree Conservation/Landscape Review Case No. ZA26-0072 Review No. One Dated: October 21, 2026 Number of Pages: 2 Project Name: Bridlegate (Plat Revision) Contact: Keith Martin Phone: (817) 748-8229 Fax: (817) 481-5713 Case No. Attachment C ZA26-0072 Page 5 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- The following comments are based on the review of plans received on October 12, 2026 . Comments designated with a number may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z or City Council. It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TREE CONSERVATION COMMENTS: 1. A Tree Conservation Plan which conforms to the development's approved Tree Conservation Plan is required prior to the issuance of any building permits. Information required for Tree Conservation Plan: i. Identification of Critical Environmental Features of the site: A. All individually protected trees B. Existing streams, drainage creeks, ponds, and other water bodies (if any) ii.Tree Survey or alternative to a tree survey iii. 2-foot contour map of the site iv. Protected trees within the tree preservation area including tree size and type v.Critical Root Zones of groups of trees vi. Critical Root Zones for individual trees required for site plans only vii. Boundaries of any tree preservation areas as identified in the ERP Map viii. Identification of areas of environmental constraints not suitable for development ix. Identification of areas of minimal environmental constraints that are suitable for development x.Areas of encroachment into Critical Environmental Features identified on the site A. Clear delineation, for each protected tree, of whether the tree will be preserved after the proposed development is constructed, altered due to proposed improvements, or could potentially be saved based upon site specific conditions xii. Stream/Creek buffers, if any xiii. Detailed site plan of all proposed improvements. (All proposed improvements shall be required to be shown only at the site plan stage for all development. Preliminary plats shall, however, show building setbacks and general location of buildings and infrastructure.) xiv.Setbacks, building lines, and buffer yards xv. The names, addresses and telephone numbers of those persons or entities who own the property and those persons or entities filing the application xvi.Such additional information as the Administrative Official may reasonably require given the particular characteristics of the property. Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 — Existing Tree Cover Preservation Requirements Case No. Attachment C ZA26-0072 Page 6 Percentage of existing tree cover on Minimum percentage of the the entire site existing tree cover to be preserved* 0% —20% 70% 20.1 —40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights- of-way as approved by City Council. * Indicates informational comment. # Indicates required items comment. Keith Martin Landscape Administrator Phone: (817) 748-8229 E-mail: kmartin(a),ci.southlake.tx.us Public Works/Engineering Review Review No. 1 Date: 10/21/2026 Case No. ZA26-0072 Plat Revision Project Name: Bridlegate Contact: Sandy Endy, P.E. Email: sendy(c-)ci.southlake.tx.us Phone: (817) 748-8033 The following comments are based on the review of plans received on: 10/13/2026 It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. GENERAL COMMENTS: 1. Add the following note to the plat: a. The proposed improvements located within the dedicated drainage easements, including, but not limited to, the detention ponds B and C, pond outlet structures and associated storm pipe, and channels 1, 2, and 3 shall be owned and maintained by the home owners association or in the absence of a home owners association, the property owner. 2. Additional comments on the required easements may be provided once further review of the civil construction plans has been completed. Sandy Endy, P.E., CFM Case No. Attachment C ZA26-0072 Page 7 Civil Engineer Phone: (817) 748-8033 E-mail: sendy(a-)-ci.south lake.tx.us Fire Department Review Pending comments. Lorenzo Chavez Fire Marshal Phone: (817) 748-8671 E-mail: Ichavez(a)ci.south lake.tx.us The following should be informational comments only All plats filed must have an original signed and stamped Tax Certificate submitted with it from each taxing unit with jurisdiction of the real property, indicating that no delinquent taxes are owed and that taxes for the current year have been paid. After September 1 st, a certificate showing that the taxes for that year are paid, but that the taxes for the upcoming year have yet to be calculated is required. (House Bills 1563 & 3101). A copy of this information may be obtained from the Tarrant County Tax Assessor/Collector's Office located at 100 E. Weatherford St. in Ft. Worth (across from the old red courthouse). There is a service charge of $10 per account for this certificate. For more information contact the Assessor/Collector's office at 817-212-6847. Please submit a revised pdf "check print" prior to submitting the blackline mylar and paper copy with original signatures. The applicant should be aware that prior to issuance of a building permit, all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Roadway Impact Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. In addition to the City of Southlake impact fees, please be aware that through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. For Tarrant County filing, original signatures and seals will be required on one 24" x 36" blackline paper copy prior to filing the plat. The copy will not be accepted if any erasures or original ink, other than signatures or seals, appear on the plat. The paper copy must have a minimum '/2 inch space between the paper edge and border. A Developers Agreement is required prior to construction of any public infrastructure. The Developer's Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off-site drainage and utility easements and impact fees. Case No. Attachment C ZA26-0072 Page 8 All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. All newly installed electric, communication and similar equipment must be underground and transformers, switch boxes, pedestals must be located or screened as to not be visible from the ROW. (Subd. Ord. No. 483, Section. 8.05, as amended). Denotes Informational Comment Case No. Attachment C ZA26-0072 Page 9 SURROUNDING PROPERTY OWNERS MAP & RESPONSES d - d rn n F r _ J EQUESTRIAN DR BOB TONES RO o m 6 9 -- FIELD OR SPO Owner Zoning Physical Acreage Response Address 1 EMMER, DANIEL P SF1-A 345 W BOB 3.06 NR JONES RD 2 SUPERINTENDENT OF CARROLL ISD NR 3 SUPERINTENDENT OF GRAPEVINE NR COLLEYVILLE ISD 4 SUPERINTENDENT OF NORTHWEST NR ISD 5 SUPERINTENDENT OF KELLER ISD NR 1000 VIOLA, FRANK J JR & LAMON, SF1-A 4000 N WHITE 9.50 CHRISTOPHER CHAPEL BLVD Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Six (6) Responses received: None (0) *Notifications are only sent to property owners within the originally platted subdivision that are within 200 feet of the proposed replat. Case No. Attachment D ZA26-0072 Page 9