Item 7B - Fire Response Letter Case ZA26-0053 1 731-733 Zena Rucker Road I Southlake Cataracts ASC
RESPONSE TO SITE PLAN REVIEW SUMMARY NO. 1
Case No. ZA26-0053
Project:Zoning Change and Site Plan—731 Zena Rucker Rd (Southlake Cataracts ASC)
Date of Review:July 30,2026 1 Response Date:August 5,2026
The following matrix responds to each comment in the City's Site Plan Review Summary No. 1. Revised plans and supporting documents are
submitted concurrently.
Response# City Comment(Summary)
1 Tree Conservation Plan shall follow the currently Complies.Previously approved Tree Conservation Plan(Fain Cuppett,ZA21-
approved plan and remain in compliance with Tree 0072/confirmed ZA25-0042)remains unchanged and is re-submitted.
Preservation Ordinance No.585.
2 Provide application fee payment of$501.00(INV- Payment will be submitted under Invoice INV-00037053.
00037053).
3 Place City case number"ZA26-0053"in the lower right Added to all revised sheets(see new Architectural Site Plan AS1.00 and
corner. accompanying exhibits).
4 Include"Site Plan"on the title block. Added on AS1.00.
5 Provide a small scale location map. Included on AS1.00(carried forward from prior approved plans).
6 Label adjacent properties with owner name,existing Shown on AS1.00 and prior approved Site Plan.
zoning,and L.U.D.
7 Show,label and dimension width of R.O.W.and traveled Shown on AS1.00.
roadway.
8 Show,label and dimension width of any easements. Shown on AS1.00 and prior plans.
9 Label the bearing and distance of each property Shown on AS1.00 and current survey.
boundary.
10 Show and label all minimum building setback lines. Shown on AS1.00(30'front, 10'rear,etc.).
11 Show and label width and type of bufferyards(dashed Type A 5'bufferyard labeled on AS1.00;full bufferyard information carried
lines+shading). forward from prior approved Landscape Plans.
12-13 Show interior landscaping/parking islands+provide Carried forward from prior approved Landscape Plans.One canopy tree
calculation chart. relocation is being addressed by Fain Cuppett Landscape Architects.
14 Show location,dimensions,max height,stories,use(s), Fully labeled on AS1.00:Building#1 = 11,400 SF(6,100 SF Shell+5,300 SF
GFA of each building. ASC), 18'-2"height,single story.
15 Label distances between buildings and from building to Shown on AS1.00.
property lines.
16 Show entrances and exits to buildings. Shown on AS1.00 and ASC Floor Plan A1.01.
17a-c Label driveway width,stacking depth,and return radii. Labeled on AS1.00 and prior approved Site Plan.
18 Provide fire lanes—show/label width and curve radii. Shown and labeled on AS1.00.Note added:"Existing Fire Lane Will Be
Unobstructed."
19-21 Trash receptacles,screening devices,walls/fences. Carried forward from prior approved Site Plan(screened dumpster,masonry
screening,etc.).
22 Drainage and Grading Plans(see Public Works). No change required.Public Works has confirmed the 2023 drainage study
remains valid;no onsite detention required.
23 Label building height on the elevations. Height labeled on AS1.00 and prior elevation sheets.
24 Provide Site Data Summary Chart(by phase and total). Updated chart provided on AS1.00(includes ASC use split and parking
reduced by 2 spaces:93 required/91 provided).
L-1 Landscape:Relocate the one required canopy tree The required revision is minor:relocate one canopy tree from the parking
displaced by the proposed canopy and show the canopy island occupied by the new patient drop-off canopy,and graphically add the
+generator enclosure on the approved Landscape Plan. freestanding canopy and fully screened generator enclosure to the previously
approved Landscape Plan.The Landscape Architect of record(Fain Cuppett
Landscape Architects,LLC)has been contacted and is preparing the sealed
revision.The revised Landscape Plan will be submitted as soon as it is
received.All other landscape and tree-conservation elements remain exactly
as previously approved.We respectfully request that the case still be placed
on the upcoming Planning&Zoning Commission agenda while this minor
revision is finalized.
Fire Ambulatory care facility triggers(IBC 708,422, IFC 907) See separate Fire Response Letter(attached).ASC suite is only 5,300 SF.
+canopy sprinkler+fire lane unobstructed. Canopy is freestanding(not attached). Fire lane remains unobstructed(noted
on AS1.00).
Page 1 of 2
Case ZA26-0053 1 731-733 Zena Rucker Road I Southlake Cataracts ASC
FIRE DEPARTMENT RESPONSE LETTER
August 5, 2026
Lorenzo Chavez, Fire Marshal
City of Southlake Fire Department
c/o Planning & Development Services
1400 Main Street, Suite 310, Southlake, TX 76092
Re: Case No. ZA26-0053—731-733 Zena Rucker Road
Southlake Cataracts ASC/ Pecan Creek Professional Center— Response to Fire Department Comments
Dear Fire Marshal Chavez:
This letter responds to the Fire Department comments contained in the Site Plan Review Summary No. 1 dated July 30,
2026 for Case ZA26-0053.
1. Ambulatory Care Facility Triggers
The specialty eye-care ambulatory surgery center will occupy only a 5,300 SF suite within the existing 11,400 SF Building
#1 (the balance of the building remains shell / professional office space).
• Because the aggregate ambulatory care area is 5,300 SF (well below 10,000 SF), IBC 422 smoke barrier and two-
smoke-compartment requirements are not triggered.
•Any suite that will contain four or more care recipients incapable of self-preservation will be separated by a fire partition
in accordance with IBC 708.
•A manual fire alarm system and supervised smoke detection in the facility and public-use areas will be provided in
accordance with IFC 907.2.2 and 907.2.2.1. These systems will be detailed and permitted as part of the tenant-
improvement/building-permit process.
2. Proposed Canopy
The patient drop-off canopy is a freestanding structure and is not attached to the building. Therefore automatic fire
sprinkler protection of the canopy is not required.
The canopy has been sited so that the existing fire lane remains completely unobstructed (explicitly noted on the revised
Architectural Site Plan AS1.00 submitted with this response).
We believe these responses fully address the Fire Department comments. Please contact me if any additional information
is needed.
Respectfully submitted,
bi ��
Bill Syblon
Director
Vision Commercial RE DFW LLC
817-726-6117 1 bill@visioncommercial.com
Enclosure:Revised Architectural Site Plan AS1.00(Case ZA26-0053)
Page 2 of 2
Page is too large to OCR.
Page is too large to OCR.
Page is too large to OCR.