Loading...
Item 6 - Pecan Creek Development Drainage Study - 2023-0214_reducedDRAINAGE STUDY FOR  TIMARRON CREEK IN SUPPORT OF THE PECAN  CREEK DEVELOPMENT IN  Southlake, Texas  February 14, 2023      Prepared by:  KCE Engineering, LLC  TBPE Firm #16940  Dr. Cuneyt Erbatur, PE, CFM, LEED AP  cuneyt@kce‐eng.com           Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 2  Introduction  The Project site is an approximately 2.255‐acre site located on the south side of Zena Rucker Rd.  between Byron Nelson Pkwy and Matthews Ct. in Southlake, Texas, as shown in Appendix A –  Figure 1.  The Project site is undeveloped but there is an existing retention pond located on the  property that was designed by Pogue Engineering & Development, Inc. in September of 2005.   Per the construction plans provided in Appendix D, this retention pond was designed with a  normal WSEL of 613.50 and a 100‐year WSEL of 617.30 and a weir outfall.  There are commercial sites to the north of Zena Rucker Rd., Rockenbaugh Elementary School to  the south and west, and single‐family residential to the east.  According to the current effective  FIRM 48439C0085K, revised September 25, 2009, there is FEMA floodplain (Zone X) within the  property  from  Timarron  Creek.    However,  the  City  of  Southlake  notified  KCE  that  Halff  &  Associates has performed an updated study for the North Central Texas Council of Governments  for the FY 14 Risk MAP Project that includes Timarron Creek and is in the process of becoming  the effective models and mapping for the area.  The report and models provided by the City of  Southlake as part of that remapping effort were used as the effective models for the area  although they are not yet approved by FEMA.  The Project is planned to be developed as a commercial development with two (2) buildings and  associated parking and other infrastructure designed by Redinger Group, LLC (RG).  The purpose of this drainage study is to determine the hydrologic and hydraulic impacts of the  proposed development to Timarron Creek, and to determine if the proposed project will cause  any adverse impacts to adjacent or downstream property owners.  The City of Southlake defines  adverse impacts as:   No new or increased flooding (0.0 feet) of existing insurable (FEMA) structures (habitable  buildings)   No increase greater than 0.1 feet in the 1, 5, and 100‐year flood elevations over existing  roadways.  No increase greater than 0.1 feet and 100‐year flood  elevations  unless  contained in existing channel, roadway, drainage easement and/or ROW.   Proposed channel velocities for 1, 5, and 100‐year storms cannot exceed the applicable  maximum permissible velocity in Table 3.16 and Table 3.17 of the City of Fort Worth  Stormwater Criteria Manual.   If existing channel velocities exceed maximum permissible velocities, no more than 5%  increase in velocities will be allowed.   No increase in downstream discharges caused by the proposed development that, in  combination with existing discharges, exceeds the existing capacity of the downstream  storm drainage system or existing right‐of‐way.        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 3  Overall Hydrologic Analysis  The City of Southlake provided KCE with the Drainage Study for Zena‐Rucker Road prepared by  Teague Nall & Perkins (TNP), dated December 2014 for the design of the existing culvert under  Zena Rucker Rd. adjacent to the Project site.  However, the City only provided KCE with the PDF  of the report and not the HEC‐HMS model used for the analysis, so KCE instead created a HEC‐ HMS model for Timarron Creek watershed to a point just downstream of the Project site to  determine if the proposed project would result in increases in the peak discharges at Timarron  Creek.  In addition, the report by TNP indicated the use of an older version of HEC‐HMS (version  3.5) as well as different rainfall data.  While this information was correct and the best available  at the time of the study, KCE has used the Atlas 14 rainfall data and HEC‐HMS version 4.9 for this  analysis.  KCE used the onsite topographic survey data provided by Spry Surveyors, LLC, dated 3/2/21 as  well as the 2019 TNRIS contour data and record drawings to determine the existing drainage  areas for the HEC‐HMS model of Timarron Creek to the downstream side of the Project site.  At  this location the contributing watershed is approximately 235‐acres, to the 2.2‐acre Project site  comprises approximately 1% of the watershed and this was taken as the Zone of Influence.  The Project site currently includes an existing retention pond that was designed as part of a  commercial  development  on  the  north  side  of  Zena  Rucker  Rd.  by Pogue  Engineering  &  Development Company, Inc., dated 9/19/05.  The record drawings are provided in Appendix D.   As part of this proposed Project, the developer is proposing to remove the existing retention  pond to allow for more commercial development.    The existing drainage area map is shown in Appendix A – Figure 2.  The main ponds and junctions  are as follows:   Fox_Pond‐1 – the existing detention pond from the Foxborough residential development  on the upstream side Foxborough Lane   Fox_Pond‐2  –  the  second  existing  detention  pond  from  the  Foxborough  residential  development located just upstream of FM 1709   J‐3 – located at the upstream side of the existing commercial drive just to the south of FM  1709   J‐4 – located at the upstream side of Zena Rucker Road   Ex_Pond‐A – the existing retention pond within the Project site   J‐5 – located at the downstream side of the Project site and the Project’s ZOI  The SCS curve number (CN) represents the runoff potential of a given area with the higher the  CN, the greater the runoff potential.  Curve numbers were determined based on the hydrologic  soil type and adjusted based on land use.  KCE used the USGS Web Soil Survey to determine the        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 4  hydrologic soil types for the drainage areas.  KCE calculated the base CN for each drainage area  and then determined the percent impervious based on the existing land uses.  For the proposed conditions CN, KCE used a percent impervious for the Project site of 70% based  on the current proposed site plan by RG.  Refer to Appendix A – Figures 2 and 4 for the existing  and proposed land uses, respectively.  Refer to Appendix A – Figure 3 for the hydrologic soil map  and refer to Appendix B for the base CN and percent impervious calculations for the existing  conditions.  The construction plans are in Appendix E.  The time of concentration is defined as the time required for water to flow from the most  hydraulically remote point of the basin to the design point of interest, in this case to the junction  locations in the HEC‐HMS model.  The path of travel is divided into sheet flow, shallow  concentrated flow and open channel flow (or closed storm drain system flow).  KCE used the  existing contour data and record drawings to determine the existing time of concentration  calculations, and the proposed plans and grading by RG for the proposed calculations.  Refer to  Appendix A – Figures 2 and 4 for the existing and proposed flowpaths, respectively.  The time of  concentration calculations are shown in Appendix B, and the proposed storm drain systems are  shown in Appendix E.  Based on the SCS Publication Technical Release (TR‐55), the watershed lag time was calculated  at 60% of the total time of concentration for the subbasin.  The watershed lag time is the time  from the center of mass of excess rainfall to the peak rate of storm water runoff.  To comply with  the City of Southlake requirements, the rainfall data used is from the iSWM technical manual for  Tarrant County.  Tables 1 and 2 below show the existing and proposed parameters for the Project, and Figures 1  and 2 below show the existing and proposed HEC‐HMS models.              Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 5  Figure 1 – Existing HEC‐HMS Model      Table 1 – Existing HMS Input Parameters  Existing Conditions HMS Input Data  Basin Area  (Sq.Mi.)  Area  (acres)  Base  CN  Impervious  Rate  Lag Time  (min)  A  0.003447  2.206  74.0  23%  11.3  OS‐A  0.009934  6.358  73.2  86%  12.2  OS‐1  0.073661  47.143  67.9  50%  18.4  OS‐2  0.144055  92.195  70.4  46%  13.8  OS‐3  0.073464  47.017  69.6  74%  17.1  OS‐4  0.036864  23.593  77.1  44%  13.5  OS‐5  0.026047  16.670  70.3  73%  13.1            Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 6  Figure 2 – Proposed HEC‐HMS Model      Table 2 – Proposed HMS Input Parameters  Proposed Conditions HMS Input Data  Basin Area  (Sq.Mi.)  Area  (acres)  Base  CN  Impervious  Rate  Lag Time  (min)  A  0.003447  2.206  74.0  70% 4.5  OS‐A  0.009934  6.358  73.2  86%  12.2  OS‐1  0.073661  47.143  67.9  50%  18.4  OS‐2  0.144055  92.195  70.4  46%  13.8  OS‐3  0.073464  47.017  69.6  74%  17.1  OS‐4  0.036864  23.593  77.1  44%  13.5  OS‐5  0.026047  16.670  70.3  73%  13.1            Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 7  Existing Detention Ponds  As  previously  discuss,  there  is  an  existing  retention  pond  within the Project site that was  constructed as part of an upstream commercial development with the construction plans by  Pogue Engineering & Development Company, Inc., dated 9/19/05.  Per the record drawings  provided, it appears that the retention pond was designed using the Modified Rational Method,  but KCE was only provided with the drainage area map and not any detention pond design plan  sheets.  Based on the drainage area map, the normal WSEL of the pond was supposed to be  613.50 with a 100‐year WSEL of 617.30.  The outfall design appears to be a weir and the tailwater  in the adjacent Timarron Creek does not appear to be taken into consideration in the original  design.    In  addition,  there  are  two  (2)  detention  ponds  within the  Foxborough  residential  development that outfall into Timarron Creek.  Please refer to Appendix  D for the record  drawings provided to KCE.  KCE used the 2019 TNRIS contour data to determine the elevation‐areas for each of the existing  detention ponds.  Although Existing Pond A was supposed to have a normal WSEL of 613.5, at  the time of the survey the WSEL was only 613.0, so KCE used this as the bottom of the storage  available in the retention pond.  The pond outfalls for the Foxborough ponds were determined  from the record drawings.  For the existing retention pond on the Project site, KCE used the  survey data to determine the pipe outfall and weir overtopping.  Since both Foxborough Pond 2  and Existing Pond A outfall into Timarron Creek, the tailwater conditions in Timarron Creek also  impacts the pond outfalls.  Tables 4 – 6 below show the elevation‐area‐volume for the existing  ponds, Tables 7 – 8 shows the tailwater elevation‐discharge for Foxborough Pond 2 and Existing  Pond A.    Table 4 – Foxborough Pond 1 Elevation‐ Area‐Volume  Fox_Pond‐1  Elevation  (ft)  Area  (acres)  Inc. Vol.  (acre‐ft)  Cum. Vol.  (acre‐ft)  626.5  0.000  0.000  0.000  628  0.009  0.007  0.007  630  0.337  0.346  0.353  632  0.495  0.832  1.185  634  0.702  1.197  2.382          Table 5 – Foxborough Pond 2 Elevation‐ Area‐Volume  Fox_Pond‐2  Elevation  (ft)  Area  (acres)  Inc. Vol.  (acre‐ft)  Cum. Vol.  (acre‐ft)  623.5  0.000  0.000  0.000  624  0.768  0.192  0.192  625  0.921  0.845  1.037  626  1.020  0.971  2.007  627  1.131  1.076  3.083  628  1.277  1.204  4.287  629  1.785  1.531  5.818          Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 8  Table 6 – Existing Pond A Elevation‐Area‐ Volume  Ex_Pond‐A  Elevation  (ft)  Area  (acres)  Inc. Vol.  (acre‐ft)  Cum.  Vol.  (acre‐ft)  613.0  0.311  0.000  0.000  614  0.383  0.347  0.347  615  0.415  0.399  0.746  616  0.475  0.445  1.191  617  0.584  0.530  1.721  618  0.584  0.584  2.305                    Table 7 – Foxborough Pond 2 Tailwater  Elevation‐Discharge  Fox Pond 2 Tailwater  RAS XS 11208  Elevation  (ft)  Discharge  (cfs)  623.74  0  623.79  1  624.4  100  624.77  200  625.09  300  625.36  400  625.61  500  626.15  750  627.02  1000  627.9  1250  628.9  1500  629.94  1750  630.51  2000  630.84  2250  631.11  2500  631.35  2800    Table 8 – Existing Pond A Tailwater  Elevation‐Discharge  Ex Pond A Tailwater  RAS XS 10021  Elevation  (ft)  Discharge  (cfs)  610.5  0  610.76  1  612.99  100  614.13  200  614.96  300  615.63  400  616.16  500  617.17  750  617.74  1000  617.93  1250  618.36  1500  618.54  1750  618.71  2000  618.87  2250  619.02  2500  619.19  2800  This existing pond information was input into the HEC‐HMS model for the watershed.        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 9  HEC‐HMS Model  These  parameters  and  detention  ponds  were  input  into  the  United States Army Corps of  Engineers HEC‐HMS (version 4.9) program to determine the peak discharges for the contributing  drainage areas for the required storm events.  The routing between Fox_Pond‐1 and Fox_Pond‐ 2 was done with the Muskingum‐Cunge method, and the routing between J‐3 and J‐4 was done  with Modified Puls method.  Table 9 below shows the Modified Puls routing data used, Table 10  below shows the calculated peak discharges for the required storm events at the HMS junctions  for the existing and proposed conditions, and Tables 11 – 13 show the pond result summaries.  Table 9 – Modified Puls Routing Data  Reach‐2  XS 10950 ‐ XS 10227  Storage  (ac‐ft)  Discharge  (cfs)  0.04  1  0.61  100  0.98  200  1.29  300  1.58  400  1.83  500  2.57  750  3.56  1000  4.66  1250  5.83  1500  7.76  1750  8.84  2000  10.05  2250    Table 10 – Peak Discharges at Junctions  Peak Discharge Comparison  Basin  Peak Discharge 5‐Yr (cfs)  Peak Discharge 10‐Yr (cfs)  Peak Discharge 100‐Yr (cfs)     Ex.  Pr.  Pr. ‐ Ex.  Ex.  Pr.  Pr. ‐ Ex.  Ex.  Pr.  Pr. ‐ Ex.  A 6  11  5  7  13  6  13  21  8  Ex_Pond‐A  13  NA  NA  14  NA  NA  58  NA  NA  Fox_Pond‐2  303  303  0  373  373  0  626  626  0  J‐3  436  436  0  534  534  0  881  881  0  J‐4  493  493  0  603  603  0  987  987  0  J‐5  539  561  22  659  685  26  1,111  1,111  0        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 10  Based on the results of the HEC‐HMS model, although Existing Pond A did reduce the peak  discharge for the 5‐ and 10‐year storm events, it did not provide any detention for the 100‐year  storm event.  There were increases in the peak discharge from the Project site due to the  proposed development, but there was no increase in the 100‐year peak discharge at Timarron  Creek at the ZOI.  There were increases in the 5‐ and 10‐year storm events, but those increases  are entirely contained within the existing 100‐year floodplain of Timarron Creek.  Table 11 – Foxborough Pond 1 Results  Fox_Pond‐1  Rain  Event  Peak  Inflow  (cfs)  Peak  Outflow  (cfs)  Peak  Storage  (acre‐ ft)  Peak  Elevation  (ft)  5‐Year  107  95  0.6  630.7  10‐Year  133  117  0.8  631.4  100‐Year  225  192  1.8  633.3    Table 12 – Foxborough Pond 2 Results  Fox_Pond‐2  Rain  Event  Peak  Inflow  (cfs)  Peak  Outflow  (cfs)  Peak  Storage  (acre‐ ft)  Peak  Elevation  (ft)  5‐Year  317  303  1.7  625.8  10‐Year  389  373  2.1  626.1  100‐Year  650  626  3.2  627.2    Table 13 – Existing Pond A Results  Existing Pond A  Rain  Event  Peak  Inflow  (cfs)  Peak  Outflow  (cfs)  Peak  Storage  (acre‐ ft)  Peak  Elevation  (ft)  5‐Year  29  13  1.5  616.5  10‐Year  35  14  1.7  617.0  100‐Year  56  58  2.2  617.8            Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 11  Overall Hydraulic Analysis  Timarron Creek is part of the NCTCOG FY14 Risk MAP Project by Halff, dated February of 2016.   It is KCE’s understanding that the report and models associated with this remapping effort are in  the process of becoming the FEMA‐effective models for the watershed but have not yet been  approved.  The City of Southlake provided KCE with the HEC‐RAS model of Timarron Creek from  this report to use as the effective model.  That model included all of Timarron Creek as well as  several tributaries.  However, the Timarron Creek model did not include the Zena Rucker Rd  crossing and had lower peak discharges than those calculated by KCE (950 cfs vs 1,100 cfs).  Since  KCE’s peak discharges were higher adjacent to the Project site, KCE created a truncated HEC‐RAS  model of Timarron Creek along Reach 3.  KCE also added cross‐sections through the Project site  to model Zena Rucker Rd and to better capture any proposed impacts to the floodplain.  The  cross‐sections added are:  101+06  100+75  100+21  The plans in the HEC‐RAS model are as follows:   TIMARRON_CREEK_WATERSHED – the Timarron Creek model by Halff dated February  2016 as part of the NCTCOG FY14 TSDN.  This model does not include Zena Rucker Rd.   TIMARRON_CREEK_ROUTING – the Timarron Creek model by Halff dated 2016 as part of  the NCTCOG FY14 TSDN.  KCE assumes that this model was used for the Modified Puls  routing data.   TIMARRON_CREEK_FLOODWAY – the Timarron Creek model by Halff dated 2016 as part  of the NCTCOG FY14 TSDN.   KCE_Corrected_MP – KCE saved the TIMARRON_CREEK_WATERSHED model and added  cross‐sections as well as Zena Rucker Rd   KCE_Corrected_Routing – the KCE_Corrected_MP model with the routing data used by  Halff   KCE_Corrected_2 – this is the model used as the existing model for the basis of  comparison.  KCE truncated the model from KCE_Corrected_MP and used the higher peak  discharges determined by KCE in the earlier hydrologic analysis.  KCE added a rating curve  for the downstream boundary conditions to tie into the effective model   KCE_Concept_Proposed_2 – this is the model used as the proposed model for the basis  of comparison.  KCE used the proposed grading by RG dated 11/11/22 to determine the  hydraulic impact of the proposed Project.  The United States Army Corps of Engineers HEC‐RAS (version 6.1) program was used to calculate  the WSEL and velocity within the limits of the study.  Tables 14 – 16 below displays the HEC‐RAS  comparison for the required storm events through the Project site.  The existing and proposed        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 12  floodplains are shown in Appendix A – Figures 5 and 6, respectively.  Refer to Appendix C for the  HEC‐RAS profile and cross‐sections comparison.  Table 14 – 100‐year HEC‐RAS Results  100‐year HEC‐RAS Results  River  Sta  W.S. Elev (ft)  Velocity (ft/s)  Ex.  Pr.  Pr‐Ex  Ex.  Pr.  Pr‐Ex  % Diff.  11208  626.52  626.52  0.00  5.53  5.53  0.00  0%  11188  626.60  626.60  0.00  3.70  3.70  0.00  0%  11108                       11038  626.51  626.51  0.00  2.38  2.38  0.00  0%  11013  626.43  626.43  0.00  3.21  3.21  0.00  0%  10985                       10950  623.40  623.40  0.00  6.04  6.04  0.00  0%  10860  623.07  623.07  0.00  5.13  5.13  0.00  0%  10660  622.31  622.31  0.00  5.09  5.09  0.00  0%  10559  621.18  621.18  0.00  7.26  7.26  0.00  0%  10440  619.99  619.99  0.00  6.33  6.33  0.00  0%  10346  619.59  619.59  0.00  4.68  4.68  0.00  0%  10227  619.37  619.37  0.00  3.59  3.59  0.00  0%  10207                       10106  618.59  618.59  0.00  3.65  3.65  0.00  0%  10075  618.18  618.18  0.00  5.43  5.44  0.01  0%  10021  617.92  617.92  0.00  5.36  5.36  0.00  0%  9936  617.24  617.24  0.00  6.59  6.58  ‐0.01  0%  9799  616.83  616.83  0.00  4.70  4.70  0.00  0%  9604  615.55  615.55  0.00  6.71  6.71  0.00  0%  9483  614.72  614.72  0.00  6.60  6.60  0.00  0%  9394  614.42  614.42  0.00  4.86  4.86  0.00  0%    Table 15 – 10‐year HEC‐RAS Results  10‐year HEC‐RAS Results  River  Sta  W.S. Elev (ft)  Velocity (fps)  Ex.  Pr.  Pr‐Ex  Ex.  Pr.  Pr‐Ex  % Diff.  11208  625.29  625.29  0.00  6.66  6.66  0.00 0%  11188  624.40  624.40  0.00  6.47  6.47  0.00 0%  11108                      11038  624.56  624.56  0.00  2.27  2.28  0.01 0%  11013  624.35  624.35  0.00  3.71  3.71  0.00 0%        Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 13  10‐year HEC‐RAS Results  River  Sta  W.S. Elev (ft)  Velocity (fps)  Ex.  Pr.  Pr‐Ex  Ex.  Pr.  Pr‐Ex  % Diff.  10985                      10950  622.26  622.26  0.00  4.79  4.79  0.00 0%  10860  621.97  621.97  0.00  4.07  4.07  0.00 0%  10660  621.16  621.16  0.00  4.53  4.53  0.00 0%  10559  620.35  620.34  ‐0.01  5.64  5.65  0.01 0%  10440  618.49  618.52  0.03  6.74  6.65  ‐0.09 ‐1%  10346  617.91  617.97  0.06  4.28  4.21  ‐0.07 ‐2%  10227  617.58  617.66  0.08  3.27  3.20  ‐0.07 ‐2%  10207                      10106  617.38  617.45  0.07  2.72  2.69  ‐0.03 ‐1%  10075  617.09  617.18  0.09  4.30  4.20  ‐0.10 ‐2%  10021  616.87  616.98  0.11  4.17  4.06  ‐0.11 ‐3%  9936  616.39  616.48  0.09  4.93  5.02  0.09 2%  9799  615.75  615.83  0.08  4.77  4.85  0.08 2%  9604  614.73  614.79  0.06  5.18  5.31  0.13 3%  9483  613.31  613.42  0.11  7.34  7.28  ‐0.06 ‐1%  9394  613.09  613.20  0.11  4.35  4.37  0.02 0%    Table 16 – 5‐year HEC‐RAS Results  5‐year HEC‐RAS Results  River  Sta  W.S. Elev (ft)  Velocity (fps)  Ex.  Pr.  Pr‐Ex  Ex.  Pr.  Pr‐Ex  % Diff.  11208  625.09  625.09  0.00  6.30  6.30  0.00 0%  11188  624.22  624.22  0.00  6.10  6.10  0.00 0%  11108                      11038  623.36  623.36  0.00  2.61  2.61  0.00 0%  11013  623.07  623.06  ‐0.01  4.27  4.27  0.00 0%  10985                      10950  621.81  621.81  0.00  4.41  4.41  0.00 0%  10860  621.52  621.52  0.00  3.74  3.74  0.00 0%  10660  620.78  620.77  ‐0.01  4.08  4.08  0.00 0%  10559  620.07  620.07  0.00  5.01  5.02  0.01 0%  10440  617.98  618.00  0.02  7.10  7.03  ‐0.07 ‐1%  10346  617.36  617.41  0.05  4.10  4.04  ‐0.06 ‐1%  10227  616.99  617.06  0.07  3.13  3.07  ‐0.06 ‐2%  10207                            Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 14  5‐year HEC‐RAS Results  River  Sta  W.S. Elev (ft)  Velocity (fps)  Ex.  Pr.  Pr‐Ex  Ex.  Pr.  Pr‐Ex  % Diff.  10106  616.85  616.93  0.08  2.46  2.43  ‐0.03 ‐1%  10075  616.58  616.67  0.09  4.05  3.94  ‐0.11 ‐3%  10021  616.36  616.47  0.11  3.90  3.78  ‐0.12 ‐3%  9936  615.91  616.01  0.10  4.50  4.59  0.09 2%  9799  615.26  615.36  0.10  4.43  4.49  0.06 1%  9604  614.27  614.38  0.11  4.74  4.80  0.06 1%  9483  612.83  612.91  0.08  7.10  7.21  0.11 2%  9394  612.58  612.68  0.10  4.07  4.13  0.06 1%    Based on the comparison of the existing conditions to the proposed conditions for the 100‐year  peak discharges, there is no change in the WSEL and only one cross‐section (XS 100+75) with a  slight increase in velocity of 0.01‐fps.  At this cross‐section, the velocity is less than 6‐fps and the  slight increase would not result in any erosive velocities, so it is not considered an adverse impact.  There were increases in the 10‐ and 5‐year storm peak discharges because of removing the  existing retention pond, so there was also a corresponding increase in the WSEL adjacent to the  Project site with the largest increase for both storms equal to 0.11‐ft.  This increase dissipates  approximately 300‐ft upstream of Zena Rucker Rd.  However, any increase in the 10‐ or 5‐year  WSEL is entirely contained within the existing 100‐year floodplain.  There are also increases and  decreases in velocity, but no increase in velocity of more than 2%.          Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023       Page | 15  Conclusions  This drainage study was performed to determine if the proposed Project would cause any  adverse impacts to adjacent properties per the City of Southlake criteria.  Although the removal  of the existing retention pond does cause an increase in the peak discharges for the 10‐ and 5‐  year storm events, there is no change to the 100‐year peak discharge to Timarron Creek as a  result of this proposed Project.  The results of the hydraulic analysis show that the proposed grading does not cause any increase  in the 100‐year WSEL and only minor changes to the velocity.  There are increases in the WSEL  for the 10‐ and 5‐year storm events, but those increases are contained within the existing 100‐ year floodplain.  There are minor fluctuations in velocity as a result of the proposed Project but  no increase of more than 2%.  Based on the results of the drainage study, the proposed Project would not result in any adverse  impacts to other properties per the City of Southlake definition.  If you have any questions or comments, please feel free to call.  Sincerely,    Dr. Cuneyt Erbatur, PE, CFM, LEED AP  Principal    a Texas limited liability corporation  TBPE Reg. No. F‐16940          Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendices  Appendix A – Figures       $+ Project Location Sources: Esri, HERE, Garmin, USGS, Intermap, INCREMENT P, NRCan, Esri Japan, METI, Esri China (Hong Kong), Esri Korea, Esri (Thailand), NGCC, (c) OpenStreetMap contributors, and the GIS User Community 0 1 2Miles ZENA RUCKER NOVEMBER 2022 1 inch = 1 miles LOCATIONMAP FIGURE 1± Legend $+Location Page is too large to OCR. Page is too large to OCR. Page is too large to OCR. Page is too large to OCR. Page is too large to OCR.       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix B – Hydrologic Data       Basin NameCalculated LongestFlowpath (ft) (1)Length (ft) (2)Slope (ft/ft) (3)Surface Type (4)Manning's n (5)TO (min) (6)Length (ft) (7)Slope (ft/ft) (8)Surface Type (9)K (10)TS (min) (11)Length (ft) (12)Slope (ft/ft) (13)Manning's n (14) X-Section TypeArea (ft2) (15)WP (ft) (16)Channel Velocity (f/s) (17)TH (min) (19)A (EX)476 100 0.010 Dense Grass 0.240 17.03 126 0.020 unpaved16.1 0.92 2500.050Channel5.00 0.83Total TO (min)=17.03Total TS (min)=0.92Total TH (min)=0.8318.79 11.3A (PR)387 50 0.030 Dense Grass 0.240 6.30 87 0.017paved20.3 0.54 2500.013Conduit6.00 0.69Total TO (min)=6.30Total TS (min)=0.54Total TH (min)=0.697.54 4.5OS-A990 100 0.010 Dense Grass 0.240 17.03 298 0.020paved20.3 1.72 5920.013Conduit6.00 1.64Total TO (min)=17.03Total TS (min)=1.72Total TH (min)=1.6420.40 12.2OS-12399 100 0.010 Dense Grass 0.240 17.03 1585 0.013paved20.3 11.57 7140.013Conduit6.00 1.98Total TO (min)=17.03Total TS (min)=11.57Total TH (min)=1.9830.59 18.4OS-22553 100 0.020 Dense Grass 0.240 12.91 164 0.049 unpaved16.1 0.77 22890.013Conduit6.00 6.36587 0.027paved20.3 2.92Total TO (min)=12.91Total TS (min)=3.68Total TH (min)=6.3622.95 13.8OS-32858 100 0.020 Dense Grass 0.240 12.91 621 0.013 unpaved16.1 5.65 21370.013Conduit6.00 5.94286 0.003paved20.3 3.97Total TO (min)=12.91Total TS (min)=9.62Total TH (min)=5.9428.46 17.1OS-41107 100 0.020 Dense Grass 0.240 12.91 1007 0.012 unpaved16.1 9.53 00.013Conduit6.00 0.00Total TO (min)=12.91Total TS (min)=9.53Total TH (min)=0.0022.44 13.5OS-51648 100 0.010 Dense Grass 0.240 17.03 138 0.014paved20.3 0.94 14100.013Conduit6.00 3.92Total TO (min)=17.03Total TS (min)=0.94Total TH (min)=3.9221.89 13.1Basin DataOverland Flow Shallow Concentrated Flow Channel/Street FlowTime of Conc. Calc. (min) (20)Lag Time (min) (22) TRAVEL TIME CALCULATIONSLag_Time_Calculations FID Label Acres HYDRO CN A*CN 14 A 2.2064199 C 74 163.2751 33 OS‐1 0.0633343 B 61 3.863392 34 OS‐1 13.8572998 B 61 845.2953 37 OS‐1 0.0122279 B 61 0.745902 38 OS‐1 14.9941998 B 61 914.6462 35 OS‐1 0.540658 C 74 40.00869 36 OS‐1 3.1405101 C 74 232.3977 32 OS‐1 14.5351 D 80 1162.808 Sub‐Total OS‐1 47.1433299 67.9 3199.765 2 OS‐2 0.831757 B 61 50.73718 3 OS‐2 30.4342995 B 61 1856.492 4 OS‐2 0.573703 B 61 34.99588 8 OS‐2 0.916689 B 61 55.91803 9 OS‐2 1.24045 B 61 75.66745 11 OS‐2 2.0760801 B 61 126.6409 5 OS‐2 3.2020199 C 74 236.9495 6 OS‐2 0.456837 C 74 33.80594 7 OS‐2 9.1315403 C 74 675.734 10 OS‐2 20.6396008 C 74 1527.33 0 OS‐2 0.380724 D 80 30.45792 1 OS‐2 22.3110008 D 80 1784.88 Sub‐Total OS‐2 92.1947014 70.4 6489.61 17 OS‐3 1.87537 B 61 114.3976 18 OS‐3 3.0882599 B 61 188.3839 23 OS‐3 18.9761009 B 61 1157.542 20 OS‐3 1.66983 C 74 123.5674 21 OS‐3 2.73417 C 74 202.3286 22 OS‐3 1.66508 C 74 123.2159 15 OS‐3 5.9363899 D 80 474.9112 16 OS‐3 5.6914401 D 80 455.3152 19 OS‐3 5.38024 D 80 430.4192 Sub‐Total OS‐3 47.0168808 69.6 3270.081 31 OS‐4 11.4361 C 74 846.2714 29 OS‐4 7.1963601 D 80 575.7088 30 OS‐4 4.9603701 D 80 396.8296 Sub‐Total OS‐4 23.5928302 77.1 1818.81 25 OS‐5 0.261956 B 61 15.97932 26 OS‐5 2.00003 B 61 122.0018 28 OS‐5 4.0981302 B 61 249.9859 EXISTING BASE CN CALCS FID Label Acres HYDRO CN A*CN EXISTING BASE CN CALCS 27 OS‐5 6.8175602 C 74 504.4995 24 OS‐5 3.49245 D 80 279.396 Sub‐Total OS‐5 16.6701264 70.3 1171.863 12 OS‐A 0.394995 B 61 24.0947 13 OS‐A 5.9625201 C 74 441.2265 Sub‐Total OS‐A 6.3575151 73.2 465.3212 FID Label Acres CATEGORY Imp. Rate A*Imper. 25 A 0.0534948 Open Space 0% 0 26 A 0.116541 Open Space 0% 0 27 A 1.52161 Open Space 0% 0 24 A 0.0024351 ROW 100% 0.0024351 28 A 0.512333 Water 100% 0.512333 Sub‐Total A 2.2064139 23% 0.5147681 68 OS‐1 1.72131 Commercial 85% 1.4631135 67 OS‐1 6.6884799 ROW 100% 6.6884799 70 OS‐1 3.9716799 Single family 38% 1.50923836 71 OS‐1 12.8950005 Single family 38% 4.90010019 72 OS‐1 13.1329002 Single family 38% 4.99050208 73 OS‐1 0.244078 Single family 38% 0.09274964 74 OS‐1 4.5871401 Single family 38% 1.74311324 75 OS‐1 2.8101101 Single family 38% 1.06784184 69 OS‐1 1.0927 Water 100% 1.0927 Sub‐Total OS‐1 47.1433987 50% 23.5478387 1 OS‐2 0.262892 Commercial 85% 0.2234582 2 OS‐2 0.75545 Commercial 85% 0.6421325 3 OS‐2 0.0238111 Commercial 85% 0.02023944 4 OS‐2 0.0155065 Commercial 85% 0.01318053 20 OS‐2 0.219292 Commercial 85% 0.1863982 8 OS‐2 0.751487 Open Space 0% 0 19 OS‐2 0.679379 Open Space 0% 0 0 OS‐2 9.1967802 ROW 100% 9.1967802 9 OS‐2 15.2726002 Single family 38% 5.80358808 10 OS‐2 28.9571991 Single family 38% 11.0037357 11 OS‐2 3.2439101 Single family 38% 1.23268584 12 OS‐2 8.3350096 Single family 38% 3.16730365 13 OS‐2 0.0128131 Single family 38% 0.00486898 14 OS‐2 1.59552 Single family 38% 0.6062976 15 OS‐2 12.7606001 Single family 38% 4.84902804 16 OS‐2 3.2681701 Single family 38% 1.24190464 17 OS‐2 3.8510301 Single family 38% 1.46339144 18 OS‐2 0.908433 Single family 38% 0.34520454 5 OS‐2 0.0105296 Water 100% 0.0105296 6 OS‐2 0.676905 Water 100% 0.676905 7 OS‐2 1.39741 Water 100% 1.39741 Sub‐Total OS‐2 92.1947278 46% 42.0850421 30 OS‐3 0.11769 Commercial 85% 0.1000365 31 OS‐3 0.139737 Commercial 85% 0.11877645 32 OS‐3 0.783233 Commercial 85% 0.66574805 33 OS‐3 1.25266 Commercial 85% 1.064761 EXISTING IMPERVIOUS RATE CALCS FID Label Acres CATEGORY Imp. Rate A*Imper. EXISTING IMPERVIOUS RATE CALCS 34 OS‐3 1.73043 Commercial 85% 1.4708655 35 OS‐3 3.1043301 Commercial 85% 2.63868059 36 OS‐3 2.8582799 Commercial 85% 2.42953792 46 OS‐3 0.0092201 Commercial 85% 0.00783709 49 OS‐3 3.97437 Commercial 85% 3.3782145 37 OS‐3 0.0004938 Open Space 0%0 48 OS‐3 0.273162 Open Space 0%0 29 OS‐3 16.9055996 ROW 100% 16.9055996 40 OS‐3 1.7948999 Single family 38% 0.68206196 41 OS‐3 0.308126 Single family 38% 0.11708788 42 OS‐3 0.137694 Single family 38% 0.05232372 43 OS‐3 0.0184382 Single family 38% 0.00700652 44 OS‐3 7.8032598 Single family 38% 2.96523872 45 OS‐3 5.6909699 Single family 38% 2.16256856 47 OS‐3 0.112334 Single family 38% 0.04268692 38 OS‐3 0.0015103 Water 100% 0.0015103 39 OS‐3 0.0004086 Water 100% 0.0004086 Sub‐Total OS‐3 47.0168462 74% 34.8109504 60 OS‐4 1.62187 Commercial 85% 1.3785895 61 OS‐4 3.8290801 Commercial 85% 3.25471809 66 OS‐4 4.9914699 Commercial 85% 4.24274942 63 OS‐4 1.00445 Open Space 0%0 64 OS‐4 9.3129597 Open Space 0%0 59 OS‐4 0.600276 ROW 100% 0.600276 62 OS‐4 0.567248 Single family 38% 0.21555424 65 OS‐4 1.66544 Single family 38% 0.6328672 Sub‐Total OS‐4 23.5927937 44% 10.3247544 51 OS‐5 1.01141 Commercial 85% 0.8596985 52 OS‐5 1.04506 Commercial 85% 0.888301 53 OS‐5 1.24884 Commercial 85% 1.061514 54 OS‐5 4.6800299 Commercial 85% 3.97802542 55 OS‐5 3.5502901 Commercial 85% 3.01774659 57 OS‐5 0.0192527 Open Space 0%0 50 OS‐5 0.558076 ROW 100% 0.558076 56 OS‐5 3.80831 Single family 38% 1.4471578 58 OS‐5 0.748846 Single family 38% 0.28456148 Sub‐Total OS‐5 16.6701147 73% 12.0950808 22 OS‐A 5.6982498 Commercial 85% 4.84351233 23 OS‐A 0.0604634 Open Space 0%0 21 OS‐A 0.598798 ROW 100% 0.598798 Sub‐Total OS‐A 6.3575112 86% 5.44231033       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix C – Hydraulic Data     0500100015002000605610615620625630TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2/14/2023 2) KCE_Ex 2/14/2023 Main Channel Distance (ft)Elevation (ft)LegendWS 100yr - KCE_PrWS 100yr - KCE_ExWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGroundGroundTIMMARON CREEK 3 0100200300400500600622624626628630632634636TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 11208 OVERBANK ELEVATIONS FROM 2019 LIDAR, CHANNEL FROM SURVEY SECTIONStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0100200300400500600700622624626628630632634636TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 11188 OVERBANK ELEVATIONS FROM LIDAR 2019, CHANNEL ELEVATIONS FROM SURStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExIneff - KCE_ExBank Sta - KCE_ExGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr 0100200300400500600700620622624626628630632634636TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 11108 Culv FM 1709 CROSSING. SEE NOTES:Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_Pr- KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_Pr- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr0100200300400500600700618620622624626628630632634TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 11038 OVERBANK ELEVATIONS FROM LIDAR 2019, CHANNEL ELEVATIONS FROM SURStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_Pr- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr 0100200300400500600700616618620622624626628630632634TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 11013 OVERBANK ELEVATIONS FROM LIDAR 2019, CHANNEL ELEVATIONS FROM SURStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_Pr- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr0100200300400500600700616618620622624626628630632634TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10985 Culv PECAN CREEK DEVELOPMENT CROSSINGStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_Ex- KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_Pr- KCE_Pr- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr 0100200300400500600700616618620622624626628630TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10950 OVERBANK ELEVATIONS FROM LIDAR 2019, CHANNEL ELEVATIONS FROM SURStation (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExIneff - KCE_ExBank Sta - KCE_ExGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr0100200300400500600700614616618620622624626628630TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10860 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr 0100200300400500600700800614616618620622624626628630TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10660 Station (ft)Elevation (ft)LegendWS 100yr - KCE_PrWS 100yr - KCE_ExWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0100200300400500614616618620622624626TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10559 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_ExWS 10yr - KCE_PrWS 5yr - KCE_ExWS 5yr - KCE_PrGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr 0100200300400500614616618620622624626TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10440 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0100200300400500612614616618620622624626TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10346 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr 0100200300400500612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10227 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr0100200300400500610612614616618620622624626TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10207 Culv Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_Pr- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr 0100200300400500600610612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10106 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr0100200300400500600610612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10075 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr 0100200300400500600610612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 10021 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0100200300400500600700800608610612614616618620622624626TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 9936 Station (ft)Elevation (ft)LegendWS 100yr - KCE_PrWS 100yr - KCE_ExWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_Ex- KCE_ExGround - KCE_ExIneff - KCE_ExBank Sta - KCE_Ex- KCE_PrGround - KCE_PrIneff - KCE_PrBank Sta - KCE_Pr 0100200300400500600608610612614616618620622TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 9799 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0100200300400500600608610612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 9604 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr 0100200300400500600700606608610612614616618620622624TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 9483 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr0200400600800606608610612614616618620622TIMARRON_CREEK_WATERSHED Plan: 1) KCE_Pr 2) KCE_Ex River = TIMMARON CREEK Reach = 3 RS = 9394 Station (ft)Elevation (ft)LegendWS 100yr - KCE_ExWS 100yr - KCE_PrWS 10yr - KCE_PrWS 10yr - KCE_ExWS 5yr - KCE_PrWS 5yr - KCE_ExGround - KCE_ExBank Sta - KCE_ExGround - KCE_PrBank Sta - KCE_Pr       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix D – Record Drawings     Page is too large to OCR. Page is too large to OCR. Page is too large to OCR. Page is too large to OCR. Page is too large to OCR. Page is too large to OCR.       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix E – Survey and Construction Plans     Page is too large to OCR. Page is too large to OCR.       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix F – Environmental Report     20 January 2023 Mr. Clayton Redinger, P.E. Redinger Group, LLC 250 Miron Drive Southlake, Texas 76092 Re: Pecan Creek Business Park - Waters of the United States Delineation Approximately 2.5 acres located at the northwestern corner of Zena Rucker Road and Matthews Court in the City of Southlake, Tarrant County, Texas. Dear Mr. Redinger, Integrated Environmental Solutions, LLC (IES) performed a site survey to identify any aquatic features that meet a definition of a water of the United States on approximately 2.5 acres located at the northwestern corner of Zena Rucker Road and Matthews Court in the City of Southlake, Tarrant County, Texas (Attachment A, Figure 1). This report will ultimately assess and delineate potentially jurisdictional aquatic features to ensure compliance with Clean Water Act (CWA) Sections 401 and 404. INTRODUCTION Waters of the United States are protected under guidelines outlined in CWA Sections 401 and 404, in Executive Order (EO) 11990 (Protection of Wetlands), and by the review process of the Texas Commission on Environmental Quality (TCEQ). Agencies that regulate impacts to the nation’s water resources within Texas include the U.S. Army Corps of Engineers (USACE), the U.S. Environmental Protection Agency (USEPA), the U.S. Fish and Wildlife Service (USFWS), and the TCEQ. The USACE has the primary regulatory authority for enforcing CWA Section 404 requirements for waters of the United States. The decision for whether a CWA Section 404 permit is required on a property is determined if there are waters of the United States present and the extent of losses of those features. The USACE and USEPA have gone through rulemaking to define what is a water of the United States, independently and jointly, several times since the initial CWA. The longest standing definitions of waters of the United States were those published in 1986; however, these definitions were challenged in 2001 and 2007 U.S. Supreme Court decisions. Since then, both the Obama and Trump administration completed rulemaking to modify the definitions of waters of the United States in the Clean Water Rule in 2016 and the Navigable Water Protection Rule (NWPR) in 2020. A recent federal district court decision in Arizona struck down the NWPR but was silent on which definitions of waters of the United States would replace it. As of the date of this letter report, the USACE Fort Worth District has provided verbal guidance that the USACE will be utilizing the pre-2015 definitions (i.e., 1986 definitions combined with the Rapanos and Carabell U.S. Supreme Court decisions) to define waters of the United States. USEPA has indicated that the pre-2015 definitions will be in place until new definitions have been developed as part of the new definitions rulemaking process that was started in June 2021, prior to the Arizona court decision. Mr. Clayton Redinger, P.E. Pecan Creek Business Park - Waters of the United States Delineation 20 January 2023 Page 2 1986 Waters of the United States Definitions and Rapanos Decision The definition of waters of the United States, in 33 Code of Federal Regulations (CFR) 328.3, includes waters such as intrastate lakes, rivers, streams (including intermittent streams), mudflats, wetlands, sloughs, wet meadows, or natural ponds and all impoundments of waters otherwise defined as waters of the United States. Also included are wetlands adjacent to waters (other than waters that are themselves wetlands). The term adjacent is defined as bordering, contiguous, or neighboring. Jurisdictional wetlands are a category of waters of the United States and have been defined by the USACE as areas that are inundated or saturated by surface or groundwater at a frequency and duration sufficient to support, and that under normal circumstances do support, a prevalence of vegetation typically adapted for life in saturated soil conditions. Waters of the United States are defined in 33 CFR 328.3 (a), 13 November 1986, as: 1. All waters which are currently used, or were used in the past, or may be susceptible to use in interstate or foreign commerce, including all waters which are subject to the ebb and flow of the tide; 2. All interstate waters including interstate wetlands; 3. All other waters such as intrastate lakes, rivers, streams (including intermittent streams), mudflats, sandflats, wetlands, sloughs, prairie potholes, wet meadows, playa lakes, or natural ponds, the use, degradation, or destruction of which could affect interstate or foreign commerce including any such waters: • Which are or could be used by interstate or foreign travelers for recreational or other purposes; or • From which fish or shellfish are or could be taken and sold in interstate or foreign commerce; or • Which are used or could be used for industrial purposes by industries in interstate commerce; 4. All impoundments of waters otherwise defined as waters of the United States under the definition; 5. Tributaries of waters identified in paragraphs (a)(1)-(4) of this section; 6. The territorial seas; 7. Wetlands adjacent to waters (other than waters that are themselves wetlands) identified in paragraphs (a)(1)-(6) of this section. On 05 June 2007, the USACE and the USEPA issued joint guidance on delineation of waters on the United States based on the U.S. Supreme Court decisions in Rapanos and Carabell. Under this guidance, potential waters of the United States have been classified as traditional navigable waters (TNW), relatively permanent waters (RPW) (i.e., having flow most of the year or at least seasonally), or non-RPWs. This guidance states that TNWs and RPWs and contiguous or adjacent wetlands to these aquatic features are waters of the United States. Wetlands that are bordering, contiguous, or neighboring another water of the United States is considered adjacent. Additionally, wetlands that are within the 100-year floodplain of another water of the United States are also considered adjacent. Non-RPWs, wetlands contiguous or adjacent to non-RPWs, and isolated wetlands must undergo a “significant nexus” test on a case-by-case basis to determine the jurisdictional nature of these aquatic features. Under the “significant nexus” test a water feature must have substantial connection to a TNW by direct flow, or by indirect biological, hydrologic, or chemical connection. Under the “significant nexus” test the USACE District Engineer must submit the jurisdictional determination (JD) to the regional USEPA office, which makes the decision whether to move the JD to Headquarters USACE to make the final determination. This guidance does not void the January 2001 decision of the U.S. Supreme Court in Solid Waste Agency of Northern Cook County (SWANCC) v. USACE which disallowed regulation of isolated wetlands under the CWA through the “Migratory Bird Rule.” Previously, the USACE assumed jurisdiction over isolated waters of the United States based on its 1986 preamble stating that migratory birds used these habitats. The “Migratory Bird Rule” provided the nexus to interstate commerce and thus protection under the CWA. However, the new guidance does require that the “significant nexus” test be performed in addition to an analysis of other potential interstate commerce uses for isolated waters. Mr. Clayton Redinger, P.E. Pecan Creek Business Park - Waters of the United States Delineation 20 January 2023 Page 3 METHODOLOGY Prior to conducting fieldwork, the U.S. Geological Survey (USGS) topographic map (Attachment A, Figures 2A and 2B), the Soil Survey of Tarrant County, Texas, and the U.S. Department of Agriculture (USDA) Natural Resources Conservation Service (NRCS) digital soil databases for Tarrant County (Attachment A, Figure 3), the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map (FIRM) (Attachment A, Figure 4), and recent and historic aerial photographs of the proposed survey area were studied to identify possible aquatic features that could meet the definition of waters of the United States and areas prone to wetland development. Mr. Lane Pressler and Mr. Rafael Gomez of IES conducted the delineation in the field in accordance with the USACE procedures on 17 January 2023. Wetland determinations and delineations were performed on location using the methodology outlined in the 1987 Corps of Engineers Wetland Delineation Manual and the Regional Supplement to the Corps of Engineer Wetland Delineation Manual: Great Plains Region (Version 2.0). The presence of a wetland is determined by the positive indication of three criteria (i.e., hydrophytic vegetation, hydrology, and hydric soils). Potential jurisdictional boundaries for other water features (i.e., non-wetland) were delineated in the field at the ordinary high-water mark (OHWM). The 33 CFR 328.3 (c)(7) defines OHWM as the line on the shore established by the fluctuations of water and indicated by physical characteristics such as a clear, natural line impressed on the bank, shelving, changes in the character of soil, destruction of terrestrial vegetation, the presence of litter and debris, or other appropriate means that consider the characteristics of the surrounding areas. Water feature boundaries were recorded on a Trimble GeoExplorer XT Global Positioning System (GPS) unit capable of sub-meter accuracy. Photographs were also taken at representative points within the survey area (Attachment B). Historic aerial photographs, from Environmental Data Resources, Inc. (EDR), were used in the jurisdictional determination of some aquatic features, are included in Attachment C. RESULTS Background Review Topographic Setting The USGS topographic map (Colleyville 7.5’ Quadrangle 1959, revised 1982) illustrates no blue line features within the survey area; however, one feature is directly to the east (see Attachment A, Figure 2A). The 2022 Colleyville 7.5’ Quadrangle map illustrates the conditions similarly (see Attachment A, Figure 2B). The overall site topography was illustrated with slopes-oriented northwest-to-southeast. The maximum site elevation was approximately 620 feet above mean sea level (amsl). Soils The USDA NRCS Web Soil Survey identified one soil map unit within the survey area, Rader fine sandy loam, 0 to 3 percent slopes. This soil map unit was not listed as a hydric soil on the Hydric Soils of Texas list prepared by the National Technical Committee for Hydric Soils (accessed 17 January 2023, Tarrant County, Texas) (see Attachment A, Figure 3). Hydric soils are described as soils that are sufficiently wet in the upper part to develop anaerobic conditions during the growing season. FEMA FIRM The FEMA FIRM (Tarrant County; Map Panel 48439C0085K and 48439C0095K; effective 25 September 2009) shows most of the survey area to be within Zone X (Areas of 0.2 percent annual chance flood; areas of 1 percent annual chance flood with average depths of less than 1 foot or with drainage areas less than 1 square mile; and areas protected by levees from 1 percent annual chance flood). A small area along the western border is within Zone X (Areas determined to be outside the 0.2 percent annual chance floodplain) (see Attachment A, Figure 4). Historic Aerial Photographs Historic aerial photographs from an aerial photograph decade package from EDR were also reviewed to understand the sequence of events that have occurred in the survey area (see Attachment C). The following paragraphs provide a description of the aerial photographs based on site conditions: Mr. Clayton Redinger, P.E. Pecan Creek Business Park - Waters of the United States Delineation 20 January 2023 Page 4 1942-1979 – The survey area is characterized as an active agricultural property comprised of plowed fields and pastureland. A large drainage channel is depicted outside the survey area near the eastern boundary. 1984-1995 – A building has been constructed in the northeastern corner. 2006-2020 – The building has been removed and a pond has been constructed in its place. Weather History The weather history for Wunderground.com W5JP weather station (KTXSOUTH110) recorded no precipitation during the 7-day period and no precipitation during the 30-day period, prior to the site visit. Field Investigation The survey area was characterized as a fallow agricultural property. One vegetation community was observed: pastureland. The pastureland consisted almost entirely of Bermudagrass (Cynodon dactylon) with bushy bluestem (Andropogon glomeratus), and Johnsongrass (Sorghum halepense) along the pond edge. Sugarberry (Celtis laevigata), honey locust (Gleditsia triacanthos), greenbrier (Smilax bona-nox), and poison ivy (Toxicodendron radicans) were also observed in the fence lines. Water from the survey area flows southeast into an unnamed tributary of Big Bear Creek. Big Bear Creek flows into Bear Creek. Bear Creek flows into West Fork Trinity River which ultimately flows in the Trinity River, a TNW. Table 1 and the following paragraphs detail the aquatic features identified within the survey area at the time of evaluation (Attachment A, Figure 5). Table 1. Aquatic Features Identified within the Survey Area Water Identification Hydrology Characteristics Post-Rapanos Water Classification 33 CFR 328.3 Definition Area (Acre) Length (Linear Feet) Pond 1 Semi-Permanently Inundated Isolated --- 0.37 --- Pond 1 was identified as an off channel, isolated, artificially excavated pond in the eastern region. Pond 1 was constructed sometime between October 2005 and 2006 to capture stormwater from nearby roads and buildings. The pond’s limits were identified and delineated by OHWM characteristics that included a natural line impressed in the bank, a wrack line, and water line. No features with OHWM characteristics were observed entering or exiting the ponds at the time of evaluation. A storm drain was observed feeding the pond from Zena Rucker Road to the north. A culvert spillway was also observed along the east side of the pond. A review of recent and historical aerial photographs indicated that Pond 1 has minor fluctuations in surface water elevation, and as such, it is IES’s professional opinion that it would be considered semi-permanently inundated. POTENTIAL JURISDICTIONAL ASSESSMENT The 05 June 2007 USACE and USEPA jointly published instructional guidebook is intended to provide the USACE field staff a national standard operating procedure for conducting jurisdictional determinations. The guidebook was prepared by combining all prior applicable provisions, regulations, statutes, and case laws pertaining to the CWA. All terms, definitions, and conclusions regarding the jurisdictional nature of the aquatic features used within this report are derived directly, as they are practiced, from the guidance. The following outlines the applicable interpretations of the guidance appropriate for this situation. Table 1 provides an overview of the jurisdictional assessment of the aquatic features under the 1986 Waters of the United States definitions and the Rapanos decision (see Attachment A, Figure 5). Non-Jurisdictional Features – Pond 1 Based on evidence, Pond 1 was created in an upland setting by excavating a depression and placing earthen fill across the natural gradient of the landscape in a manner to collect and redirect upslope sheet flow and stormwater with no signs of previous jurisdictional features in the vicinity. Under the 2007 guidance: Pond 1 would not be subject to jurisdiction under CWA Section 404, by definition, as it; Mr. Clayton Redinger, P.E. Pecan Creek Business Park - Waters of the United States Delineation 20 January 2023 Page 5 • is not a natural pond, impoundment of waters, or waters as defined in paragraphs (a)(1)-(7) of the CWA 33 CFR 328.3; • is not a TNW or wetland adjacent to a TNW, nor are they non-navigable tributaries of a TNW with relatively permanent flow or wetlands that abut such tributaries; and • as clarified under 33 CFR 323.2 (b), The term lake … As used in this regulation, the term does not include artificial lakes or ponds created by excavating and/or diking dry land to collect and retain water for such purposes as stock watering, irrigation, settling basins, cooling, and rice growing. Furthermore, no evidence that this pond was utilized for recreational or commercial purposes was observed. As such, this pond does not provide interstate commerce and would not be subject to jurisdiction under CWA Section 404. CONCLUSIONS To summarize the delineation a pond was identified and delineated within the survey area. Under the 1986 waters of the United States definitions and the Rapanos decision, Pond 1 would not be considered jurisdictional as it was a man-made, isolated feature on the landscape. As such, this feature would not be regulated under CWA Section 404. This delineation is based on professional experience in the approved methodology and from experience with the USACE Fort Worth District regulators; however, this delineation does not constitute a jurisdictional determination of waters of the United States. This delineation has been based on the professional experience of IES staff and our interpretation of USACE regulations at 33 CFR 328.3, the joint USACE/USEPA guidance regarding the Rapanos and Carabell decisions and the Regulatory Guidance Letter (RGL) 08-02. While IES believes our delineation to be accurate, final authority to interpret the regulations lies solely with the USACE and USEPA. The USACE Headquarters in association with the USEPA often issue guidance that changes the interpretation of published regulations. USACE/USEPA guidance issued after the date of this report has the potential to invalidate the report conclusions and/or recommendations, which may create the need to reevaluate the report conclusions. IES has no regulatory authority, as such, proceeding based solely upon this report does not protect the Client from potential sanction or fines from the USACE/USEPA. The Client acknowledges that they can submit this report to the USACE for a preliminary jurisdictional determination for concurrence prior to proceeding with any work within aquatic features located on the survey area. If the Client elects not to do so, then the Client proceeds at their sole risk. IES appreciates the opportunity to work with you and Redinger Group, LLC on this project, and we hope we may be of assistance to you in the future. If you have any comments, questions, or concerns, please do not hesitate to contact myself or Rudi Reinecke at 972-562-7672 (lpressler@intenvsol.com or rreinecke@intenvsol.com). Sincerely, Integrated Environmental Solutions, LLC. Mr. Lane Pressler Biologist / Wetland Scientist Attachments File ref: 04.354.088 ATTACHMENT A Figures Figure 1. General Location Map Area of Detail Scale: 1 inch equals 10 miles 04.354.088 1/17/2023File Ref. Date: Survey Area -0 500 Feet 1 in = 500 feet Pecan Creek Business Park City of Southlake Tarrant County, Texas Survey AreaFigure 2A. Topographic Setting Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/20/2023 File Ref. Date:-0 300 Feet 1 in = 300 feet USGS Colleyville 7.5' Quad 1959 revised 1982 Survey AreaFigure 2B. Topographic Setting Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/20/2023 File Ref. Date:-0 300 Feet 1 in = 300 feet USGS Colleyville 7.5' Quad 2022 Survey Area Soil map units outside survey area Soil Map Units RaA - Rader fine sandy loam, 0 to 3 percent slopes Figure 3. Soils Map Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/17/2023 File Ref. Date:-0 130 Feet 1 in = 130 feet Survey AreaFigure 4. Federal Emergency Management Agency Flood Insurance Rate Map Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/17/2023 File Ref. Date:-0 130 Feet1 in = 130 feet PANEL 48439C0085K 48439C0095K eff. 9/25/2009 FEMA FIRM Zone Descriptions Zone X - Areas determined to be outside the 0.2% annual chance floodplain Zone X - Areas of 0.2% annual chance flood; areas of 1% annual chance flood with average depths of less than 1 foot or with drainage areas less than 1 square mile; and areas protected by levees from 1% annual chance flood Zone AE - Special Flood Hazard Areas subject to inundation by the 1% annual chance flood; Base flood elevations determined Zone AE - Floodway areas in Zone AE Zone A - Special Flood Hazard Areas subject to inundation by the 1% annual chance flood; No base flood elevations determined Survey Area Aquatic Features That Do Not Meet a Definition of a Water of the United States Pond, Isolated Figure 5. Aquatic Features Identified within the Survey Area Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/18/2023 File Ref. Date:-0 70 Feet 1 in = 70 feet ATTACHMENT B Site Photographs Survey Area Photograph Location Aquatic Features That Do Not Meet a Definition of a Water of the United States Pond, Isolated Photograph Location Map Pecan Creek Business Park City of Southlake Tarrant County, Texas 04.354.088 1/19/2023 File Ref. Date:-0 70 Feet 1 in = 70 feet Photograph 1 Photograph 2 Photograph 3 Photograph 4 Photograph 5 Photograph 6 Photograph 7 Photograph 8 Photograph 9 Photograph 10 Photograph 11 Photograph 12 ATTACHMENT C Historic Aerial Photographs The EDR Aerial Photo Decade Package Pecan Creek Business Park Southlake Southlake, TX 76092 Inquiry Number: January 12, 2023 7223454.1 6 Armstrong Road, 4th floor Shelton, CT 06484 Toll Free: 800.352.0050 www.edrnet.com 2020 1"=500'Flight Year: 2020 USDA/NAIP 2016 1"=500'Flight Year: 2016 USDA/NAIP 2012 1"=500'Flight Year: 2012 USDA/NAIP 2006 1"=500'Flight Year: 2006 USDA/NAIP 1995 1"=500'Acquisition Date: January 31, 1995 USGS/DOQQ 1990 1"=500'Flight Date: January 29, 1990 NAPP 1984 1"=500'Flight Date: June 01, 1984 TXDOT 1979 1"=500'Flight Date: November 11, 1979 USDA 1972 1"=500'Flight Date: February 03, 1972 USDA 1968 1"=500'Flight Date: May 01, 1968 USGS 1950 1"=500'Flight Date: December 30, 1950 USDA 1942 1"=500'Flight Date: April 02, 1942 USDA EDR Aerial Photo Decade Package 01/12/23 Pecan Creek Business Park Site Name:Client Name: Integrated Env. Solutions, Inc. Southlake 301 W Eldorado Parkway Suite 101 Southlake, TX 76092 McKinney, TX 75069 EDR Inquiry #7223454.1 Contact:Lane Pressler Environmental Data Resources, Inc. (EDR) Aerial Photo Decade Package is a screening tool designed to assist environmental professionals in evaluating potential liability on a target property resulting from past activities. EDR’s professional researchers provide digitally reproduced historical aerial photographs, and when available, provide one photo per decade. Search Results: Year Scale Details Source When delivered electronically by EDR, the aerial photo images included with this report are for ONE TIME USE ONLY. Further reproduction of these aerial photo images is prohibited without permission from EDR. For more information contact your EDR Account Executive. Disclaimer - Copyright and Trademark Notice Copyright 2023 by Environmental Data Resources, Inc. All rights reserved. Reproduction in any media or format, in whole or in part, of any report or map of Environmental Data Resources, Inc., or its affiliates, is prohibited without prior written permission. EDR and its logos (including Sanborn and Sanborn Map) are trademarks of Environmental Data Resources, LLC or its affiliates. All other trademarks used herein are the property of their respective owners. 7223454 1-page 2 This Report contains certain information obtained from a variety of public and other sources reasonably available to Environmental Data Resources, LLC. It cannot be concluded from this Report that coverage information for the target and surrounding properties does not exist from other sources. This Report is provided on an “AS IS”, “AS AVAILABLE” basis. NO WARRANTY EXPRESS OR IMPLIED IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT. ENVIRONMENTAL DATA RESOURCES, LLC AND ITS SUBSIDIARIES, AFFILIATES AND THIRD PARTY SUPPLIERS DISCLAIM ALL WARRANTIES, OF ANY KIND OR NATURE, EXPRESS OR IMPLIED, ARISING OUT OF OR RELATED TO THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES REGARDING ACCURACY, QUALITY, CORRECTNESS, COMPLETENESS, COMPREHENSIVENESS, SUITABILITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, MISAPPROPRIATION, OR OTHERWISE. ALL RISK IS ASSUMED BY THE USER. IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES, LLC OR ITS SUBSIDIARIES, AFFILIATES OR THIRD PARTY SUPPLIERS BE LIABLE TO ANYONE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL, CONSEQUENTIAL OR OTHER DAMAGES OF ANY TYPE OR KIND (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS, LOSS OF USE, OR LOSS OF DATA), ARISING OUT OF OR IN ANY WAY CONNECTED WITH THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT. Any analyses, estimates, ratings, environmental risk levels, or risk codes provided in this Report are provided for illustrative purposes only, and are not intended to provide, nor should they be interpreted as providing any facts regarding, or prediction or forecast of, any environmental risk for any property. Only an assessment performed by a qualified environmental professional can provide findings, opinions or conclusions regarding the environmental risk or conditions in, on or at any property. 7223454.1 2020 = 500' 7223454.1 2016 = 500' 7223454.1 2012 = 500' 7223454.1 2006 = 500' 7223454.1 1995 = 500' 7223454.1 1990 = 500' 7223454.1 1984 = 500' 7223454.1 1979 = 500' 7223454.1 1972 = 500' 7223454.1 1968 = 500' 7223454.1 1950 = 500' 7223454.1 1942 = 500'       Drainage Study  Timarron Creek for the Pecan Creek Development – Southlake, TX    February 14, 2023         Appendix G – Electronic Data