Item 4F - Staff Report CITY OF Item 4F
S0UTHLA1<,.._E
Department of Planning & Development Services
STAFF REPORT
September 4, 2026
CASE NO: ZA26-0058
PROJECT: Plat Revision for Johnson Park
EXECUTIVE
SUMMARY: Clayton Redinger, Redinger Group, LLC, is requesting approval of a Plat
Revision for Johnson Park, being a revision of Lot 16, J.G. Allen No. 18 Addition,
City of Southlake, Tarrant County, Texas and located at 3095 Johnson Road.
Current Zoning: "SF-1A" Single Family Residential District. Property Owner:
Keller ISD. Applicant: Clayton Redinger, Redinger Group, LLC. SPIN
Neighborhood #11.
DETAILS: The purpose of this request is to seek approval of a Plat Revision to subdivide
approximately 13.867 acres located at 3095 Johnson Road into four single-family
residential lots (Lots 1 through 4) totaling approximately 4.518 acres and the
remaining 9.349 acres (Lot 5)for the Keller ISD Florence Elementary School site.
The proposed Plat Revision conforms to the recently approved Zoning Change
and Concept Plan under the case ZA26-0035.
ACTION NEEDED: 1) Consider Approval of a Plat Revision
ATTACHMENTS: (A) Background Information
(B) Vicinity Map
(C) Plat Revision Review Summary No. 1, dated August 28, 2026
(D) Surrounding Property Owners Map and Responses
PowerPoint Presentation
Plans
STAFF CONTACT: Dennis Killough (817) 748-8072
Cyndi Cheng (817) 748-8269
Case No.
ZA26-0059
BACKGROUND INFORMATION
OWNER: Keller ISD
APPLICANT: Clayton Redinger, Redinger Group, LLC
PROPERTY SITUATION: 3095 Johnson Road
LEGAL DESCRIPTION: Lot 16, J.G. Allen No. 18 Addition, City of Southlake, Tarrant County,
Texas
LAND USE CATEGORY: Low Density Residential
CURRENT ZONING: "SF-1A" Single Family Residential District
HISTORY:
The original Florence Elementary school was constructed in 1975.
The property was annexed into the City in 1988.
City Council placed the "CS" zoning on the property with the adoption of
the Comprehensive Zoning Ordinance No. 480 on September 19, 1989.
City Council approved a Concept Plan for an addition to the school on
May 5, 1998. (ZA98-028)
A Plat Showing (ZA12-033) was approved by City Council on May 8,
2012.
A Site Plan for Florence Elementary School (ZA20-0023) to construct a
new school to replace the existing school was approved by City Council
on May 5, 2020.
A complete rebuild of Florence Elementary School was completed in
2021.
A Zoning Change and Concept Plan and Comprehensive Land Use
Amendment(ZA26-0035, CP26-0006)were approved on August 4, 2026.
SOUTHLAKE
COMPREHENSIVE PLAN: Future Land Use Plan
The Southlake Future Land Use Plan designates the subject property as
Low Density Residential.
Low Density Residential Purpose: The purpose of the Low-Density
Residential land use category is to provide for and to protect low intensity
detached single-family residential development that promotes the
openness and rural character of Southlake.
Definition: The Low-Density Residential category is for detached single-
family residential development at a net density of one or fewer dwelling
units per acre. Net density is the number of dwelling units per net acre,
which excludes acreage in all rights-of-way, easement, and lots
Case No. Attachment A
ZA26-0059 Pagel
designated for public or private streets. Other suitable activities are those
permitted in the Public Parks/Open Space and Public/Semi-Public
categories. The Low-Density Residential category encourages the
openness and rural character of the City of Southlake.
Mobility & Master Thoroughfare Plan
The Master Thoroughfare Plan designates Johnson Road as a 70-foot
(C2U) undivided collector.
Sidewalks exist along Johnson Road and Harrell Drive adjacent to the
subject property.
UTILITIES: The property is served by a 16-inch water line main along Harrell Drive,
connected by a valve gate on Johnson Road and an 8-inch sanitary sewer
line along Harrell Drive.
DRAINAGE: Drainage generally flows from east to west.
PLANNING AND ZONING
COMMISSION ACTION: September 3, 2026; Approved (5-0), subject to the Staff Report dated
August 28, 2026, and subject to Plat Revision Review Summary No. 1,
dated August 28, 2026, as presented.
STAFF COMMENTS: Attached is Plat Revision Review Summary No. 1, dated August 28, 2026.
Case No. Attachment A
ZA26-0059 Page 2
Vicinity Map
3095 Johnson Rd
32 �4 0" J .i6()B .
a
3 3240 Q 3 30 L, g w 2�03 290 r
27 3 6d1 600 01 . .,w p 300 m o 6a
LU-JOHNSON
r
Q
315 _
C 75 3255 32�5, 185
2895 .;
Y
2A0 III
135
435 A6
425LU
2935 146 —
419
+,p t
407
Fn ,
2955 152
345
333 2945 e156
31 W
.23
N
0 0.010.03 0.06 0.09 0.12
Miles Park
:, 4 Tn-�•I Murwi
ZA26-0059 - _ _Ewk _
* Notifications are only sent to property
owners within the originally platted
subdivision that are within 200 feet of the Grapewk"e `
jj
proposed replat. k4���¢
Case No. Attachment B
ZA26-0059 Page 1
PLAT REVISION REVIEW SUMMARY
Case No.: ZA26-0059 Review No.: One Date of Review: 08/28/26
Project Name: Plat Revision —Johnson Park
APPLICANT: Redinger Group, LLC OWNER: Keller ISD
Clayton Redinger George Curry
550 Silicon Dr, Ste. 100 3095 Johnson Rd
Southlake, TX 76092 Southlake, TX 76092
CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON
08/06/26 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY
MADE CONDITIONS OF PLAT APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY
COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE
CONTACT CYNDI CHENG AT (817) 748-8269.
The following changes are needed according to the Subdivision Ordinance, as amended, Sections
3.01, 3.03, & 8.01.
1. Place the City case number ZA26-0059" in the lower right-hand corner of the plat.
According to Subdivision Ordinance 483, as amended, Section 3.03.13 items to be included on
the final plat:
2. Add a vicinity/location map
3. Label the POB on the face of the plat.
4. The following changes are needed with regard to the legal description:
a. Provide the deed record volume and page for the current owner(s) in the preamble.
Please identify all current record owners on the plat and provide the required owner
signatures and notarization in accordance with the City of Southlake platting
requirements.
b. Label the Point of Beginning (P.O.B) on the plat.
C. Verify the calls to match the legal description and the plat.
• The distance "468.48' and "468.51"` do not match.
• The metes and bounds P.O.B description and other calls refer to "Lot 18" rather
than "Lot 16". Please correct this reference.
5. Add the following notes to the face of the final plat:
a. It is the property owner's (or Home Owners Association) responsibility to maintain
all drainage easements and detention/retention structures on the property (within
the subdivision). (As amended per Ord. No. 483-R)
Case No. Attachment D
ZA26-0059 Page 1
6. Harrell Drive is labeled twice on the plat with different dimensions. Please revise the ROW label
to show the 60' Harrell Drive.
7. The following changes are needed with regard to easements:
a. Show and label the type, size and deed record of all existing easements on the
property.
8. Provide sidewalks and/or trails in compliance with the Subdivision Ordinance No. 483, as
amended and the Master Pathways Plan.
Tree Conservation/Landscape Review
Case No. ZA26-0059 Review No. One Dated: August 19, 2026 Number of Pages: 2
Project Name: 3095 Johnson Road (Plat Revision)
Contact: Keith Martin Phone: (817) 748-8229 Fax: (817) 481-5713
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
The following comments are based on the review of plans received on August 10, 2026 . Comments
designated with a number may be incorporated into the formal review to be considered by either the
Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z
or City Council. It is the applicant's responsibility to contact the department representative shown above
and make modifications as required by the comment.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TREE CONSERVATION COMMENTS:
1. Please provide the required Tree Conservation Plan which conforms to the approved Tree
Conservation Plan approved with case ZA26-0035. Ensure that the tree's ID numbers are clearly legible.
Information required for Tree Conservation Plan:
i. Identification of Critical Environmental Features of the site:
A. All individually protected trees
B. Existing streams, drainage creeks, ponds, and other water bodies (if any)
ii.Tree Survey or alternative to a tree survey
iii. 2-foot contour map of the site
iv. Protected trees within the tree preservation area including tree size and type
v.Critical Root Zones of groups of trees
vi. Critical Root Zones for individual trees required for site plans only
vii. Boundaries of any tree preservation areas as identified in the ERP Map
viii. Identification of areas of environmental constraints not suitable for development
ix. Identification of areas of minimal environmental constraints that are suitable for
development
x.Areas of encroachment into Critical Environmental Features identified on the site
xi. Clear delineation, for each protected tree, of whether the tree will be preserved
after the proposed development is constructed, altered due to proposed
improvements, or could potentially be saved based upon site specific conditions
Case No. Attachment D
ZA26-0059 Page 2
xii. Stream/Creek buffers, if any
xiii. Detailed site plan of all proposed improvements. (All proposed improvements shall
be required to be shown only at the site plan stage for all development. Preliminary
plats shall, however, show building setbacks and general location of buildings and
infrastructure.)
xiv.Setbacks, building lines, and buffer yards
xv. The names, addresses and telephone numbers of those persons or entities who
own the property and those persons or entities filing the application
xvi.Such additional information as the Administrative Official may reasonably require
given the particular characteristics of the property.
2 Please provide the existing tree canopy cover calculations on the Tree Conservation Plan. The
existing tree canopy cover calculations consist of the total percentage of existing tree canopy cover on
the property, the total percentage of existing tree canopy cover proposed to be removed, and the total
percentage of existing tree canopy cover proposed to be preserved.
Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation
Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance
with the percentage requirements established by Table 2.0. If the property has previously received a tree
permit related to development, the percentage of existing tree cover at the time the first such permit was
issued shall be used to calculate the minimum existing tree cover that must be preserved under this
section.
Table 2.0 — Existing Tree Cover Preservation Requirements
Percentage of existing tree cover on Minimum percentage of the
the entire site existing tree cover to be
reserved*
0% —20% 70%
20.1 —40% 60%
40.1% - 60% 50%
60.1% - 80% 40%
80.1% - 100% 30%
*The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-
of-way as approved by City Council.
* Please be aware that all existing trees shown to be preserved on the City Council approved Tree
Conservation Plan must be preserved and protected during all phases and construction of the
development. Alteration or removal of any of the existing trees shown to be preserved on the approved
Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by
the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures
grading, and any other structure proposed to be constructed do not conflict with existing trees intended to
be preserved.
* Indicates informational comment.
# Indicates required items comment.
Keith Martin
Landscape Administrator
Case No. Attachment D
ZA26-0059 Page 3
Phone: (817) 748-8229
E-mail: kmartin(a�ci.south lake.tx.us
Public Works/Engineering Review
Review No. 1 Date: 8/19/2026
Case No. ZA26-0059 Plat Revision
Project Name: 3095 Johnson
Contact: Sandy Endy, P.E.
Email: send @ci.southlake.tx.us
Phone: (817) 748-8033
The following comments are based on the review of plans received on: 8/6/2026
It is the applicant's responsibility to contact the department representative shown above and make
modifications as required by the comment.
GENERAL COMMENTS:
1. Please show and label the existing easements for the school site. There is an existing
waterline easement for the looped waterline around the new school that was dedicated by
separate instrument.
Sandy Endy, P.E., CFM
Civil Engineer
Phone: (817) 748-8033
E-mail: sends cnci.south lake.tx.us
Case No. Attachment D
ZA26-0059 Page 4
Fire Department Review
Case No. ZA26-0059 Review No. 1 Dated: 08/27/2026 Number of Pages: 1
Project Name: 3095 Johnson Rd
Contact: Lorenzo Chavez, Fire Marshal Phone: 817-748-8671 Fax: 817-748-8181
---------------------------------------------------------------------------
---------------------------------------------------------------------------
The following comments are based on the review of plans received on 0811212026. Comments may be
incorporated into the formal review to be considered by either the Planning and Zoning Commission or
City Council. It is the applicant's responsibility to contact the department representative shown above
and make modifications as required by the comment.
---------------------------------------------------------------------------
---------------------------------------------------------------------------
GENERAL COMMENTS:
To facilitate emergency response, R-3 occupancies should be addressed on the street fronting
the property.
Lorenzo Chavez
Fire Marshal
Phone: (817) 748-8671
E-mail: Ichavez(a)ci.southlake.tx.us
The following should be informational comments only
All plats filed must have an original signed and stamped Tax Certificate submitted with it from each
taxing unit with jurisdiction of the real property, indicating that no delinquent taxes are owed and
that taxes for the current year have been paid. After September 1 st, a certificate showing that the
taxes for that year are paid, but that the taxes for the upcoming year have yet to be calculated is
required. (House Bills 1563 & 3101). A copy of this information may be obtained from the Tarrant
County Tax Assessor/Collector's Office located at 100 E. Weatherford St. in Ft. Worth (across from
the old red courthouse). There is a service charge of$10 per account for this certificate. For more
information contact the Assessor/Collector's office at 817-212-6847.
Please submit a revised pdf "check print" prior to submitting the blackline mylar and paper copy
with original signatures.
The applicant should be aware that prior to issuance of a building permit, all required fees must be
paid. This may include but not be limited to the following fees: Park Fee, Roadway Impact Fee,
Water& Sewer Impact and Tap Fees, and related Permit Fees.
In addition to the City of Southlake impact fees, please be aware that through the wholesale water
customer contract with the City of Fort Worth, all new water connections are required to pay the
City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final
plat recordation date and building permit issuance. The applicant is encouraged to review the City
of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount.
Case No. Attachment D
ZA26-0059 Page 5
For Tarrant County filing, original signatures and seals will be required on one 24" x 36" blackline
paper copy prior to filing the plat. The copy will not be accepted if any erasures or original ink, other
than signatures or seals, appear on the plat. The paper copy must have a minimum 1/2 inch
space between the paper edge and border.
All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment
Control Ordinance No. 946, as amended.
All newly installed electric, communication and similar equipment must be underground and
transformers, switch boxes, pedestals must be located or screened as to not be visible from the
ROW. (Subd. Ord. No. 483, Section. 8.05, as amended).
Case No. Attachment D
ZA26-0059 Page 6
SURROUNDING PROPERTY OWNERS MAP & RESPONSES
rnnKSF113f:T -.._r_i..i
I I
I
.,.n 30HNSOPo Hl
c
I
JfL.SC61R
1 I
SPO Owner Zoning Physical Acreage
Address
1 SOUTHLAKE CITY OF CS 3045 JOHNSON 13.03
RD
2 KELLER, ISD CS 3095 JOHNSON 13.90
RD
Responses: F: In Favor O: Opposed To U: Undecided NR: No Response
Notices Sent: Five (5)
Responses received: None (0)
*Notifications are only sent to property owners within the originally platted subdivision that are within
200 feet of the proposed replat.
Case No. Attachment E
ZA26-0059 Page 3