Loading...
Item 7B - Narrative &--, VL K July 28, 2026 Corridor Planning Committee City of Southlake 1400 Main Street, Suite 310 Southlake, TX 76092 Reference: Sanctuary Addition and Renovations St. Martin in the Fields Episcopal Church VLK Project No. 25-0155.00 Dear Committee Members: In response to the City's request, please find attached the updated S-P-2 Site Plan District Regulations for St. Martin in the Fields Episcopal Church (see Exhibit A). The regulations have been updated from those contained in Exhibit B of Ordinance No. 480-321 to reflect the current project scope, with all proposed revisions shown as tracked changes. Regarding the tower height and location: the proposed bell tower is 43 feet in height, measured from finish floor to the top of the parapet. This falls within the existing S-P-2 regulations, which permit the bell tower to be up to one hundred (100)feet to its highest point, and no amendment to that provision is required. The height is noted here for the City's reference. The tower is proposed more than 200 feet from the north property line and approximately 115 feet from the west property line to fit within the proposed addition to the sanctuary. The revised regulations also clarify the sanctuary setback as it relates to additions to the existing building. Rather than applying a fixed setback distance from the property line, the proposed updated language provides that additions to the existing building shall not extend further toward the north property line than the northernmost wall of the existing building. In addition to the sanctuary building addition, the church proposes a small storage building to be constructed of masonry materials to match the existing building. This will be located near the parking lot and serve as enclosed storage for sporting goods utilized on the fields south of the parking lot. Also attached to this letter are revisions to the site plans and landscape plans that address comments from the initial submission. Please do not hesitate to contact us with any questions. Sinc I , Justi . Hiles, AIA, NCARB, LEED®AP BD+C Chief Information Officer Attachments: Exhibit A, proposed S-P-2 Site Plan District Regulations Site Plan revisions V L May 11, 2026 Planning &Zoning Commission City of Southlake 1400 Main Street, Suite 310 Southlake, TX 76092 Reference: St. Martin in the Fields Episcopal Church Sanctuary Addition & Renovations 223 S Pearson Ln, Southlake, TX VLK Project No. 25-0155.00 Dear Members of the Planning &Zoning Commission: On behalf of St. Martin-in-the-Fields Episcopal Church, VLK respectfully submits this Site Plan application for the proposed Sanctuary Addition and Renovation located at 223 S Pearson Lane in Southlake, Texas. The following narrative describes the scope of work, the nature of the use, and the operational characteristics of the facility, along with a summary of the driveway spacing variance submitted concurrently with this application. Protect Description St. Martin-in-the-Fields Episcopal Church is an established religious institution that has served the Southlake community since 1982. The church campus occupies an 11.79-acre site, zoned SP-2, and currently includes a 6,100 sq. ft. sanctuary and office transept, a Parish Hall constructed in 1994, a Memorial Garden and columbarium, and a 133-space concrete parking lot. A renovation of the west half of the Parish Hall was completed in fall 2025. The proposed project consists of a 2,600 sq. ft. addition to the west and south of the existing sanctuary, along with interior renovations to the existing sanctuary building. The addition introduces a new primary entry at the south elevation through a 43-foot tower and narthex, public restrooms, and a covered arcade connecting the new south entry to the existing parish hall. Interior renovations will expand seating capacity to just over 250 occupants, remove the existing choir loft to create a single-level accessible worship space, and update interior finishes throughout. The project does not expand the parking lot, alter the fire lane, or add new driveways. Five parking spaces are being removed to accommodate the addition footprint, with two accessible spaces being relocated. The total parking count following construction will be 133 spaces, which exceeds the required 99 spaces based on the zoning ordinance formula of one space per three seats. Use and Operations The site will continue to operate as a place of religious assembly. Primary use is weekend worship services, with ancillary weekday activities including religious education, small group meetings, pastoral offices, and community events. The operational profile of the facility has remained consistent since its original development and will not change as a result of the proposed improvements. Peak parking and traffic demand is concentrated on Sunday mornings, dispersed across multiple service times, and does not generate the sustained or concentrated queuing typical of daily-use commercial or institutional developments. City of Southlake Planning&Zoning Commission May 11,2026 VLK Project No.25-0155.00 Page 2 of 2 Driveway Spacing Variance Concurrent with this Site Plan submittal, the applicant requests a variance from the minimum driveway spacing requirements of the City of Southlake Driveway Ordinance No. 634. The ordinance requires a minimum centerline-to-centerline separation of 150 feet for driveways on collector streets. South Pearson Lane is classified as a collector street on the City's Master Thoroughfare Plan. The two existing driveways serving the property are spaced approximately 87 feet apart, centerline to centerline—a deviation of approximately 63 feet from the required minimum. Both driveways were constructed in 1982 as part of the original development of the campus and predate the current ordinance standards. Neither driveway is being modified, widened, relocated, or reconfigured as part of the proposed project. No new driveway access is proposed. The variance is the minimum necessary to allow the project to proceed. The existing driveway configuration has operated safely throughout the property's 44-year history without documented incident, and the project does not alter the site conditions that give rise to the nonconformity. A full variance application narrative, including findings addressing unique conditions, public welfare, and the absence of special privilege, is included as an attachment to this submittal. We appreciate the Commission's consideration of this application and welcome the opportunity to discuss the project in further detail. Please do not hesitate to contact our office with any questions. Sincerely, Justi Hiles, AIA, NCARB, LEED®AP BD+C Chief Information Officer JSH/ Attachments: Site Plan Application Package and associated documents Driveway Spacing Variance Application cc: File