Loading...
Item 6D - Staff Report Item 6D 19 CI"T`Y OF SOUTHLAKE Department of Planning & Development Services STAFF REPORT June 8, 2026 CASE NO: ZA26-0027 PROJECT: Zoning Change and Development Plan for 1360 N. Carroll Avenue EXECUTIVE SUMMARY: Curtis Young of Sage Group on behalf of 1360 N. Carroll Investment Group, LLC is requesting approval of a Zoning Change and Development Plan on property described as Tract 4A,A.H. Chivers Survey, Abstract No. 299 and located at 1360 N. Carroll Avenue. Current Zoning: "AG" Agricultural District. Requested Zoning: "R-PUD" Residential Planned Unit Development District. SPIN Neighborhood #3. DETAILS: The purpose of this request is to seek Zoning Change and Development Plan approval for a 7.3-acre single-family development. The property is located on the southwest side of N. Carroll Avenue, and the requested zoning is "R-PUD" Residential Planned Unit Development District. The proposal includes 3 single family residential lots that average 51,649 SF in area. On May 7, 2026, the Planning and Zoning Commission recommended approval (6-0), noting the request for three, 100-foot-wide lots, side setbacks to match the 100-foot-wide width, and a shared slip road driveway with two entrances and 18-20 feet wide with two lanes. On June 2, 2026, City Council approved the first reading (4-3) noting approval of driveway plan #1 as shown at the meeting with garages not facing N. Carroll Avenue, unless it is the single garage of a three-car garage, 10-foot side setbacks on Lot 1, 15-foot side setbacks on Lot 2, a 10-foot side setback on the northern portion of Lot 3 and a 20-foot side setback on the southern portion of Lot 3. Following the meeting, the applicant submitted a revised development plan and development regulations reflecting the direction provided by City Council at first reading regarding setbacks and garage orientation. Residential Data Summary Existing Zoning AG Existing Land Use Mixed Use Proposed Land Use Mixed Use Proposed Zoning R-PUD Number of Residential Lots 3 Average Res. Lot Size s.f. 51,649 SF Net Density .41 Gross Acreage 7.285-acres Net Acreage 7.022-acres Case No. ZA26-0027 Proposed R-PUD Regulations SF-20A Front:30' Front:35' Side: Side:15' Lot 1:10'both sides Rear:40',except for Setbacks Lot 2:15'both sides Setbacks lots fronting a cul-de- Lot 3:North-10';South-20' sac(35') Street Side Yard:NA Rear:40'or Floodplain/Floodway restriction Minimum Lot Area Per Development Plan I Minimum Lot Area '■ 20,000 SF I -51,649 SF Lot Width Minimum of 100' F6 Lot Width Minimum of 100' Maximum Lot Coverage 30% I Maximum Lot Coverage 30% Minimum Floor Area 3,500 SF Minimum Floor Area 1,800 SF Side facing,except for a single front-facing garage Garage Exposure permitted to the rear of a minimum 2 car side-facing garage ComparisonDevelopment Regulations ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider 2nd Reading Approval for a Zoning Change and Development Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Development Plan Review Summary No. 4, dated June 8, 2026 (D) Surrounding Property Owners Map Property Owner Responses Ordinance No. 480-847 PowerPoint Presentation Plans Development Regulations Corridor Planning Committee Report SPIN Meeting Report STAFF CONTACT: Dennis Killough (817) 748-8072 Ryan Firestone (817) 748-8127 Case No. ZA26-0027 BACKGROUND INFORMATION OWNER: 1360 N. Carroll Investment Group, LLC APPLICANT: Curtis Young PROPERTY SITUATION: 1360 N. Carroll Avenue LEGAL DESCRIPTION: Tract 4A, A.H. Chivers Survey LAND USE CATEGORY: Mixed Use CURRENT ZONING: "AG" Agricultural District PROPOSED ZONING: "R-PUD" Residential Planned Unit Development District HISTORY: The property was annexed into the City in 1957. A previously existing house was demolished in 2018. SOUTHLAKE COMPREHENSIVE PLAN: Consolidated Future Land Use Plan The future land use designation for the site is Mixed Use. Mixed Use Purpose: To provide an option for large-scale, master- planned, mixed use developments that combine land uses such as office facilities, shopping, dining, parks, and residential uses. Definition: The range of activities permitted, the diverse natural features, and the varying proximity to thoroughfares of areas in the Mixed Use category necessitates comprehensively planned and coordinated development. New development must be compatible with and not intrusive to existing development. Further, special attention should be placed on the design and transition between different uses. Typically, the Mixed Use designation is intended for medium to higher-intensity office buildings, hotels, commercial activities, retail centers, and residential uses. Nuisance- free wholly enclosed light manufacturing and assembly uses that have no outdoor storage are permitted if designed to be compatible with adjacent uses. Other suitable activities are those permitted in the Public Parks/Open Space, Public/Semi-Public, Low Density Residential, Medium Density Residential, Retail Commercial, and Office Commercial categories. Mobility & Master Thoroughfare Plan The Master Thoroughfare Plan designates N. Carroll Ave as an "A2U" 88' 2-lane undivided arterial road. N. Carroll Avenue is designated to have a sidewalk of a minimum 5-foot width. The Master Pathways Plan also calls for an 8-foot multi-use trail on the northern side of the property. TRANSPORTATION ASSESSMENT: Area Road and Network Conditions The site proposes access off of N. Carroll Avenue. Case No. Attachment A ZA26-0027 Page 3 Traffic Impact: The project does not exceed the traffic threshold criteria of the Driveway Ordinance No. 634 that would require a full Traffic Impact Analysis. TREE PRESERVATION: There is 41.96% of existing tree cover. A total of 93.48% of existing tree cover is proposed to be preserved and 6.52% proposed to be removed. UTILITIES: The site is served by a 12-inch water line main and an 8-inch sewer line along N. Carroll Avenue. DRAINAGE: Drainage will generally flow to the west toward the floodplain and Dove Creek. A drainage easement meeting the requirements of the Drainage Ordinance will be required for the existing Dove Creek. No onsite detention is proposed; therefore, supporting engineering analysis will be required at platting to demonstrate that detention is not necessary and that the proposed improvements will not adversely impact downstream properties. CITIZEN INPUT: This item was heard at the April 22, 2026, Corridor Planning Committee. This item was presented to SPIN on May 12, 2026. PLANNING AND ZONING COMMISSION : May 7, 2026; Approved (6-0), subject to the Staff Report dated May 1, 2026, and subject to the Development Plan Review Summary No.2,dated May 1, 2026, noting the request for three, 100-foot-wide lots,side setbacks to match the 100-foot-wide width, and a shared slip road driveway with two entrances and 18-20 feet wide with two lanes. CITY COUNCIL: June 2, 2026; Approved (4-3), subject to the Staff Report dated May 22, 2026, and the Development Plan Review Summary No. 3, dated May 22, 2026, approving the R-PUD zoning change and development plan for 3 single family residential lots with an approximate average lot area of 51,469 square feet and one open space lot, the approval of driveway plan #1 as shown tonight with garages not facing N. Carroll Avenue, unless it is the single garage of a three-car garage, 10-foot side setbacks on Lot 1, 15- foot side setbacks on Lot 2, a 10-foot side setback on the northern portion of Lot 3 and a 20-foot side setback on the southern portion of Lot 3. STAFF COMMENTS: Attached is Development Plan Review Summary No.4,dated June 8,2026 Case No. Attachment A ZA26-0027 Page 4 Vicinity Map 1360 N Carroll Ave v1' 4025 2 x Y 15I>5 %f 406, 2 21 ,� . 17 �.. 4 1 4W _ 11510': �.. "LAKE"CARILLON'° 1001 _ 1204 , i 06- � - WHISPERING • 1201 1203 12G&1 p 'k.4 Q gp ' u i r2" F { 1330 .- 13i01 1280 t k 93Q, 700 - � 1320 � ��,. •�� ' 1O00 1210 , N '$� 0 0.010.03 0.06 0.09 0.12 r ��^ F:o.inokz Country ,b Miles ` ophyciut�" " -�_ - _ Lakevrew Park Oak Gm e Park ZA26-0027 Grapevine IIler - .dk cu Case No. Attachment B ZA26-0027 Page 5 DEVELOPMENT PLAN REVIEW SUMMARY Case No.: ZA26-0027 Review No.: Four Date of Review: 06/08/26 Project Name: Zoning Change and Development Plan — 1360 N. Carroll Avenue APPLICANT: Sage Group, Inc. OWNER: 1360 N. Carroll Investment Group, LLC Curtis Young Deepa Colluru 1130 N. Carroll Ave, Ste. 200 717 Helmsley Place Southlake, TX 76092 Southlake, TX 79092 CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 05/22/26 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT RYAN FIRESTONE AT (817) 748-8127. 1. Ensure that a minimum of 44' from the established centerline of N. Carroll Avenue is shown for dedicated ROW per the City's Master Mobility Plan, such that a minimum of 88' of ROW for an A2U Arterial cross-section. Tree Conservation/Landscape Review Case No. ZA26-0027 Review No. Two Dated: May 1, 2026 Number of Pages: 2 Project Name: 1360 North Carroll Ave. (Zoning/Development Plan) Contact: Keith Martin Phone: (817) 748-8229 Fax: (817) 481-5713 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- The following comments are based on the review of plans received on April 20, 2026 . Comments designated with a number may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z or City Council. It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TREE CONSERVATION COMMENTS: The proposed tree conservation complies with the existing tree cover preservation requirements of the Tree Preservation Ordinance 585-E. There is 41.96% of existing tree cover on the property and under straight zoning a minimum of 50% of the existing tree cover would be required to be preserved. A total of 93.48% of the existing tree cover is proposed to be preserved, 4.19% proposed to be altered, and 2.33% is proposed as Marginal to alter. Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at Case No. Attachment C ZA26-0027 Page 6 the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 — Existing Tree Cover Preservation Requirements Percentage of existing tree cover on Minimum percentage of the the entire site existing tree cover to be reserved* 0% —20% 70% 20.1 —40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. For property sought to be zoned for the Downtown zoning district or a planned development zoning district, including an S-P-1 Site Plan, S-P-2 Site Plan, Transition, Rural Conservation, Planned Unit Development,or Employment Center zoning district, the City Council shall consider the application for a Conservation Analysis or Plan in conjunction with the corresponding development application (as established in Table 1.0). The Planning and Zoning Commission shall review the application and make a recommendation to the City Council regarding the application. The City Council shall approve the Plan or Analysis if the Council finds that the Plan or Analysis provides for the: i. placement of building pads, parking areas, driveways, streets, and utility easements so as to maximize the preservation of environmental features of the property including mature tree stands, natural creeks and ponds, and significant grades; ii. maximizes the preservation of tree cover preservation areas indicated on the Environmental Resource Protection Map; iii. maximizes the preservation of existing tree stands with the potential to buffer residential areas from the noise, glare, and visual effects of nonresidential uses; iv. maximizes the preservation of existing trees, if any, adjoining a natural or man-made drainage creek; V. maximizes the preservation of existing protected trees along rural roadways and other streets as identified and prioritized in the Street Typology designation; and vi. mitigation of altered trees through proposed tree replacement procedures pursuant to this Ordinance. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. Case No. Attachment C ZA26-0027 Page 7 Public Works/Engineering Review GENERAL COMMENTS: 1. What is the distance between the proposed driveways and the adjacent driveways across the street? Is there a traffic concern with the adjacent driveways not lining up? DRAINAGE COMMENTS: 2. A drainage easement will be required to be dedicated for the existing Dove Creek that complies with the Drainage Ordinance. 3. Onsite Detention is not being proposed for this development. Proof that detention is not necessary and the proposed improvements will not cause adverse impacts will be required to be submitted. Sandra Endy, P.E. Development Engineer Phone: (817) 748-8033 E-mail: sendy@ci.southlake.tx.us Fire Department Review INFORMATIONAL COMMENTS: The residences must be located within 1000 feet of a fire hydrant, measured as the hose would be laid, or an additional hydrant will be required. An automatic fire sprinkler system shall be installed in all residential structures that exceed 6,000 square feet, excluding porches and patios. Fire apparatus access needs to be provided within 150 feet of all exterior portions of the perimeter of buildings on a "hose-lay" basis for un-sprinkled buildings and 250 feet for sprinklered buildings. Lorenzo Chavez Fire Marshal Phone: (817) 748-8671 E-mail: Ichavez@ci.southlake.tx.us Case No. Attachment C ZA26-0027 Page 8 General Informational Comments Building permit(s) are required prior to commencement of any work. All mechanical equipment must be screened of view from right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. All development must comply with the Drainage Ordinance No.605 and the Erosion and Sediment Control Ordinance No. 946, as amended. It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and will require construction standards that meet requirements of the Airport Compatible Land Use Zoning Ordinance No. 479. The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Roadway Impact Fee, Water& Sewer Impact and Tap Fees, and related Permit Fees. In addition to the City of Southlake impact fees, please be aware that through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. Residential development or concept plan: • Contact USPS regarding mail delivery requirements and where delivery points should be located. Denotes Informational Comment Case No. Attachment C ZA26-0027 Page 9 SURROUNDING PROPERTY OWNERS MAP & RESPONSES 928 R 000 1004 OtE t4o2 �i LAKE CARILLON LN I..c IS L 1212 1204 WHISPERING LN L205 1 1201 ` 1203 2 \ I 950 5 1330 8 waft 4 6 1 30I 1280 SPO # Owner Zoning Physical Address Acreage Response 1 SOUTH LAKE CITY OF ECZ 1001 LAKE CARILLON 6.54 NR LN 2 MAGGI, DARIUS R SF1-A 1201 WHISPERING LN 0.89 NR 3 CARROLL, ISD CS 1301 N CARROLL AVE 1.18 NR 4 SOUTH LAKE CITY OF C3 930 E HIGHLAND ST 2.36 NR 5 OSCAR WOLFE FAMILY CEMETERY CS 950 E HIGHLAND ST 0.15 NR 6 SOUTH LAKE CITY OF C3 1320 N CARROLL AVE 0.42 NR 7 ISLAMIC CENTER OF SOUTHLAKE CS 1280 N CARROLL AVE 1.43 NR 8 QUINN, WILLIAM W ` AG ` 1330 N CARROLL AVE ` 1.07 O 9 PROIETTI, TERESA SF1-A 1200 WHISPERING LN 1.62 NR 10 KHAN, ASHRUF SF1-A 1203 WHISPERING LN 1.03 NR 11 CHOOSE JOY THROUGH JESUS AG 1510 N CARROLL AVE 0.98 O LIVIN 12 SOUTH LAKE CITY OF ` ECZ 480 E SH 114 7.51 NR 13 VTR HC SOUTHLAKE LLC SP1 700 E SH 114 12.54 NR 14 SUPERINTENDENT OF CARROLL NR ISD 15 SUPERINTENDENT OF GRAPEVINE ` NR Case No. Attachment D ZA26-0027 Page 10 COLLEYVILLE ISD 16 SUPERINTENDENT OF NR NORTHWEST ISD 17 SUPERINTENDENT OF KELLER ISD NR 1000 1360 N CARROLL INVESTMENT AG 1360 N CARROLL AVE 7.32 GROU Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Fifteen (15) Responses received within 200': Opposed: One (1) Responses received within 300': Opposed: One (1) Responses received outside 300': Opposed: Six (6) Case No. Attachment D ZA26-0027 Page 11