Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Item 4C - Exhibits
N C:\Users\rafa1\AppData\Local\Temp\AcPublish_38792\1088 WESTPARK CIRCLE S-E1.dwg Apr 16, 2026 - 9:53am PH: 817-874-1050 DATE: SUBDIV: ADDRESS: LOT: BLOCK: CITY: COUNTY: HOMEOWNER: WALK: DRIVE: FLATWORK (SQFT) CITY: APPROACH: LS/SOD: LOT COVERAGE: FENCE (LF): NOTE: ALL LOT DIMENSIONS, SETBACKS, AND EASEMENTS TO BE VERIFIED BY CITY FOR PERMIT PRIOR TO CONSTRUCTION. SITE PLAN PLAN: THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, AND RESTRICTIONS TAKE PRECEDENCE OVER ANY PART OF THESE PLANS WHICH MAY CONFLICT WITH THE SAME, AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS, AND THEIR USE ARE THE PROPERTY OF SINGLE TWIST STUDIO, AND ARE NOT TO BE USED FOR CONSTRUCTION, REUSED, TRACED OR REPRODUCED BY ANY MEANS WITH THE EXPRESSED WRITTEN CONSENT OF SINGLE TWIST STUDIO. ALL RIGHTS RESERVED. STATE: I. G. BELCHER 1088 WESTPARK CIRCLE S -- -- SOUTHLAKE DENTON TEXAS 12-15-2025 01-15-2026 04-16-2026 -- -- 834 171 207' ---- 41% 1"=20'1088 WESTPARK CIRCLE S 6' FENCE CONC DRIVE N 89°7'0.00" W 95.00'N 0°53'0.00" E 115.00'S 89°7'0.00" E 95.00'S 0°53'0.00" W 115.00'25' REAR SETBACK 10' SIDE SETBACK10' SIDE SETBACK15' B.L. LOT AREA= 10,925 SLAB AREA= 4,473 4' CONC LEAD WALK 74'-7"16'-0"72'-11"26'-1"18'-1" 10'-0" 10'-0" 11'-6" 10'-5" 10'-5" 11'-11" 27'-0"20'-5"14'-0" I.D. 4001 PINE 20 4020 4016 4017 4018 4019 4013 4014 4015 4021 4006 4005 4004 4003 4007 4001 4002 4008 4009 4010 4011 4012 DBH (INCHES)COMMON NAME 4002 4003 4004 4021 4020 4019 4018 4017 4016 4015 4014 4013 4012 4011 4010 4009 4008 4007 4006 4005 PINE HACKBERRY 18 14 10 10 18 16 18 16 18 14 20 20 18 16 24 12 10 12 14 10 PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE PINE LOWER FLOOR PLAN 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36) 6' STANDALONE TUB 18'0"x8'0" GARAGE DOOR10'0"x8'0" GARAGE DOOR MBATH 12'-0" CLG 2-CAR GARAGE 11'-0" CLG 1-CAR GARAGE 11'-0" CLG 2-2080 MUD RM 12'-0" CLG 2-3080 EXT ENTRY OPEN TO ABV. WC 80100 CO PWDR 12'-0" CLG 3080 EXTPREP ISLAND96100 CO 12'-0" CLG COV'D PATIO HERS 12'-0" CLG GUEST SUITE 12'-0" CLG 190100 COHDR ABV. DINING 12'-0" CLG KITCHEN 12'-0" CLG BENCHLOCKERSBOX CLG MASTER SUITE 22'-8" CLG COV'D PORCH GCLOS. 12'-0" CLG AREA CALCULATIONS BUILDING DATA W/ MASONRY EXTERIOR FRAMING SHEETROCK TO SHEETROCK 1ST FLOOR 3085 3045 2896 2ND FLOOR 0 2214 2072 GARAGE 945 908 858 COVERED PORCH 44 COVERED PATIO 399 TOTAL FRAME 6610 TOTAL INT FACE FRAME 5826 TOTAL APPRAISAL 6245 TOTAL SLAB 4473 LIVING AREA 5299 AREA UNDER ROOF 6687 160100 SLDG DOOR UNIT LIVING RM OPEN TO ABV.2650 FX8'-6" H.H.2650 FX8'-6" H.H.16" HEARTH60" LINEAR FP3-3070 FX MULL 9'-0" H.H.3080 EXTISLAND2-3070 CSMNT 8'-6" H.H. VEST. 12'-0" CLG KING3-3070 SH MULL 8'-6" H.H. 3-3070 FX MULL 8'-6" H.H.3060 FX8'-6" H.H.ALL EXTERIOR WALLS TO BE 2x6 ALL EXTERIOR WALLS TO BE 2x6 ALL EXTERIOR WALLS TO BE 2x6 ALL EXTERIOR WALLS TO BE 2x6FLUSH ISLANDFOYER 12'-0" CLG FURR DOWN 2880WC 268030" REF. COL. 30" FRZ COL. 5' T/S GBATH 12'-0" CLG 2680 2680 GALLERY OPEN TO ABV. PANTRY 12'-0" CLG 12" SEAT30100 EXT 26802-2080RAIN HEAD LAUNDRY 12'-0" CLG 3060 FX 8'-6" H.H. 12'-0" CLG 13'-0" CLG 12'-0" CLG 13'-0" CLG 12" SEATWET AREA 12'-0" CLG WC DWFLOATING STAIRS40100 CO28802680 LINEN 2680A/C CHASE 2680A/C CHASE QUEEN2-3070 FX MULL 8'-6" H.H. STAIRS BASED ON 11" THREADRANGE W/ HOODVENT ABV.BLDR TO VERIFY FP TYPEPER SUBDIVISIONCOATCLOSET2x62x6 2x6 2x62x6 2x62x62x62x6 KNEE SPACE 1 2 WALL W/ GLASS ABV.2x62x6FURR DOWNFURR DOWN℄ WH WH 2x82x82x62x6 44100 COFLOOR PLAN NOTES:1.INTERIOR DIMENSIONS ARE TO FACE OF STUD, UNLESS GRAPHICALLY INDICATED OTHERWISE.WINDOWS AND DOORS ARE DIMENSIONED TO CENTERLINE OF ROUGH OPENINGS.2.REFER TO ELEVATIONS AND ROOF PLAN FOR PLATE HEIGHTS.3.CEILING HEIGHT CALL OUTS ARE NOMINAL. SEE ELEVATIONS AND ROOF PLAN FOR PRECISEDIMENSIONS.4.ALL ANGLES OTHER THAN 90° ANGLES ARE TO BE 45° ANGLES, U.O.N.5.ALL EGRESS HALLWAYS FROM BEDROOMS SHALL NOT BE RESTRICTED TO LESS THAN 3'-0” NET CLEAR.6.EXTERIOR BRICK WALLS (BRICK LEDGE) ARE SHOWN AS 5” WIDTH.7.ALL PLUMBING WALLS SHALL BE 2X6 MIN., U.O.N.8.THIS PLAN IS A GRAPHIC REPRESENTATION FOR ESTIMATING PURPOSES ONLY. ACTUAL FIELDCONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE PROCEEDING WITH CONSTRUCTION.9.ALL GLAZING WITHIN 2'-0” HORIZONTAL DISTANCE FROM ANY JAMB OF EXTERIOR DOORS SHOULD BETEMPERED GLASS.10.GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT'S ATTIC AREA BY NOT LESS THAN 1/2"GYP. BOARD TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BYNOT LESS THAN 5/8" TYPE X GYP BOARD OR EQUIVALENT.11.ALL OPENINGS TO BE CENTERED ON WALLS U.O.N.12.STANDARD DOOR JAMB TO BE 4”.13.6" MIN DROP FROM FINISHED MATERIAL TO FINISHED GRADE; FINISHED GRADE TO SLOPE AWAYFROM FOUNDATION AT A 1/4" PER FOOT.13'-0" CLG FURR DOWN BLDR TO VERIFY MFG. R.O. SPECS OF SLDG DOOR FULL STONEFULL STONEFULL STONESTONEFULL STONESTONE01 02 03 04 0706 05 1 2 3 4 5 6 7 8 9 10 11 12 13 14 EGEGEG18" PLATFORM @ WH BLDR TO VERIFY GAS OR ELEC AT WH; ALSO VERIFY BUILDING CODE PER SUBDIV. 18" PLATFORM @ WH BLDR TO VERIFY GAS OR ELEC AT WH; ALSO VERIFY BUILDING CODE PER SUBDIV. © COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" LOWER FLOOR PLAN A101 WC 2680 EXT 12'-0" CLG EXT. PWDR NICHE 3070 SH8'-6" H.H.3070 SH8'-6" H.H.3-3070 FX MULL9'-0" H.H.3-3070 FX MULL9'-0" H.H.38100 COFURR DOWN 8020 FX9'-0" H.H.6'-9"6'-9" 13'-6"5'-0"17'-8"5'-0"7'-10"10'-9"1'-10"9'-2"2'-9"1'-1" 4'-7"4'-7"5'-41 2"5'-41 2"3'-11"3'-11"5'-7"2'-9"5'-7"6'-2"12'-8"1'-11"2'-2"1'-10"2'-10"8'-0"13'-5"1'-7"2'-6"16'-2"13'-6"6'-6"7'-0"26'-1"20'-10"13'-6"1'-0"1'-8"4'-4"3'-5"2'-1"74'-7"6'-0"72'-11"6'-4"6'-4" 12'-8"28'-0" 18'-2" 8'-10"9'-4" 74'-7" 1'-6"8'-1"6'-4"5'-11"1'-1"2'-4"2'-10"10'-2"12'-8" 5'-2"22'-10" 2'-0"8'-7"7'-1"13'-9"3'-10"5'-6"34'-0"72'-11"21'-11"2'-1"10'-5"11'-6"08 VARIES 8'-0" AFF TYP.UNLESS NOTED OTHERWISECASED OPENING (CO) TYP. CASED OPENING N.T.S. 1" CHAMFER TYP. NAILER ROD NAILER ROD ROD PROVIDE CENTER SUPPORT BRACKET IF ROD LENGTH EXCEEDS 4'-0", TYP. PAINTED 3/4" THK. X 16" DEEP BULLNOSE PARTICLE BOARD SHELF STOCK.7'-0"5'-6"1'-6"3"5 EQ. SPACES4'-1"2'-11"3"3"DOUBLE HANGERSHELVES W/LOW HANGERSINGLE HANGER TYPICAL CLOSET SECTION N.T.S. A B C 1"x4" KICKER CABINET DOOR 2"x4" CONT. CABINET SHELVES DRAWER GUIDES 1"x NAILER BACKSPLASH DRAWER COUNTERTOP (O.T.S.)CLG HT. (RE: FLOOR PLAN)CABINET BACKING IF NECESSARY 1'-0"VARIES PER CLG HEIGHTOR OWNER SPEC.1'-8"3'-0"2'-1" 3" 3/4" ADJUSTABLE SHELVING CABINET DOOR CABINET BACKING IF NECESSARY OPTIONAL MOULDING N.T.S. TYP. KITCHEN CABINET DETAIL CLG HT. (RE: FLOOR PLAN)3'-0"1'-10" 3" 1"x4" KICKER CABINET DOOR 2"x4" CONT. CABINET SHELVES DRAWER GUIDES 1"x NAILER BACKSPLASH DRAWER COUNTERTOP (O.T.S.) CABINET BACKING IF NECESSARY TYP. BATH CABINET DETAIL N.T.S. OPEN OPEN COAT DOWELS 8'-0"1'-514"6'-634"WAINSCOT 5'-0"BENCH OPEN OPEN TYP. MUD BENCH N.T.S.48" FIREPLACEWOOD BURNING F.P.2x6 24'-4" 1'-10"4'-4" 2'-2"2'-2"2'-9"7'-0"2'-6"2'-1"3'-5"24'-7" 10'-0" CLG W D 5'-0"5'-11"10'-11"23'-1"14'-11"2'-1"9'-8"3'-2"2x630802680 HIS 12'-0" CLG 2x6 2x6℄ FLOATING VANITY WALL MOUNT FAUCET, BLDR TO VERIFY HEIGHT FLOATING VANITY FLOATING VANITY WALL MOUNT FAUCET, BLDR TO VERIFY HEIGHT WALL MOUNT FAUCET, BLDR TO VERIFY HEIGHT 6'-9"4'-6"2'-10"1'-6"2'-11"14'-9" 14'-1"7"3'-10"5'-7"9'-2"22'-7" 8'-10"8'-8"5'-1" 2'-0"9'-2"3'-8"5'-0"1'-8"8"3'-8"2'-8"5'-4"1'-5"6'-10"8'-8"9'-6"13'-3" 2'-10"12'-0"4'-0"6"5'-10"9'-0"2'-2"5'-8"9'-10"3'-6"2'-2"3'-10"13'-3" 6'-7"2'-10"4'-0"4'-0"23'-3"1'-4"5'-2"7'-2"6"5'-0"1'-6"5'-8"7'-7" 2'-10"11'-4"5'-2"22'-2"1'-2"4'-8"7'-0"12'-8"7'-7" 1'-0"3'-6"6"1'-2"12'-2"6'-0"1'-2"7'-2"2'-10"6'-9"11'-0"4'-11"13'-6"12'-8"2'-1"13'-7"4'-8"1'-8"3'-10"6"5'-8"8'-6"6'-4"7'-7"4'-6"8'-0"4'-2"20'-6"1'-4"8'-0"1'-7"4'-0"6'-8"2'-4"2'-6"8'-0"10'-6"24'-10"2'-7"7"22'-4"3'-0"2'-10"4'-2"6'-0"4'-6"2'-2"6'-6"3'-10"4'-0"1'-11"2'-9"4'-2"2'-8"6'-3"14'-8"2'-2"10'-4"15'-6" LOWER FLOOR PLAN (ELECTRICAL) 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36) MBATH 2-CAR GARAGE 1-CAR GARAGE MUD RM ENTRY PWDR COV'D PATIO HERS GUEST SUITE DINING KITCHEN MASTER SUITE COV'D PORCH GCLOS. LIVING RM VEST. FOYER GBATH GALLERY PANTRY LAUNDRY WET AREA A/C CHASE A/C CHASE CHAND TO LT ABOVE CHAND 1'0"x4'0" LED1'0"x4'0" LED 1'0"x4'0" LED1'0"x4'0" LED1'0"x4'0" LEDCLG PLUG CLG PLUG WP WPWP 1'0"x4'0" LED 1'0"x4'0" LED BLD TO LOC. FLOOR PLUG CHAND SS PB PB SS SSSS S S SSSSS SSSS SSSS FAN ONLY SS STO LT ABOVE TO LT ABOVE SOFFIT PLUG SOFFIT PLUG SOFFIT PLUG SS PEN PEN PEN PEN SINK-TOP AIR SWITCH PUSH GARBAGE DISPOSAL SS SSSS TO LT ABOVE TO FAN ABOVE SS TO FAN ABOVE TO LT ABOVE SSS U.C. & A.C. LTG, TYP.U.C. & A.C.LTG, TYP.U.C. & A.C.LTG, TYP.FLD LTS TO BE ON TIMER/PHOTOCELL; BUILDER TO VERIFY FLD LTS TO BE ON TIMER/PHOTOCELL; BUILDER TO VERIFY FLD LTS TO BE ON TIMER/PHOTOCELL; BUILDER TO VERIFY FLD LTS TO BE ON TIMER/PHOTOCELL; BUILDER TO VERIFY ELECTRICAL PLAN NOTES:1.200V/GAS PER SPECS @ W.H., A/C, RANGE AND DRYER.2.IF GAS, STUBS TO BE LOCATED PER CITY SPECIFICATIONS.3.EXTERIOR ELECTRICAL OUTLETS TO BE WEATHER-RESISTANT/WEATHERPROOF4.PROVIDE 110V WIRED "INTERCONNECTED" SMOKE DETECTORS OR PER LOCALCODES REQUIREMENTS.5.EXTERIOR COLUMN AND PORCH LIGHTS TO BE MOUNTED PER ELEVATIONS OR ASDIRECTED IN FIELD BY BUILDER.6.LIGHT FIXTURE IN BEDROOMS TO BE PRE-WIRED AND BLOCKED FOR CEILING FANIF NEEDED.7.BUILDER TO INSTALL ALL LIFE SAFETY DEVICES PER CODE.8.BUILDER/SUB-CONTRACTOR IS RESPONSIBLE FOR ENSURING ALL ELECTRICALCODES AND REQUIREMENTS ARE MET. ELECTRICAL PLANS CONTAINED WITHINTHIS SET ARE FOR SCHEMATIC PURPOSES ONLY.9.BUILDER TO VERIFY GAS OR ELECTRIC AT COOKTOP AND BUILDING CODEREQUIREMENTS.NOTE: U.C. AND A.C. LTG.REFERS TO UNDER ANDABOVE CABINET LIGHTINGCONTRACTOR SHALL REVIEW ALL ELECTRICAL REQUIREMENTS ANDNOTIFY DESIGNER/BUILDER OF ANY DISCREPANCIES PRIOR TOINSTALLATION. FIELD CONDITIONS MAY REQUIRE ADJUSTMENTS. ALLWORK TO BE PERFORMED IN COMPLIANCE WITH THE 2023 NEC AND LOCALAMENDMENTS.ELECTRICAL LEGEND 110 V. DUPLEX 220 V. LIGHT SWITCH RECESSED CAN LT. SURFACE MT. LT. DIRECT'L CAN SOFFIT LIGHT S PHONE JACK 110 V. GFI VENT & LIGHT VENT ONLY SURFACE MT. LT. CABLE TV (CAT 6) SMOKE DETECTOR CARBON MONOXIDE CLG/WALL MT. SPKR POP UP ISLAND PLUG SINK DISPOSAL FLOOD LIGHT SCONCES WALL MT. WALL MT. LT. WALL MT. ABV. DR UP LIGHT FAN & LIGHT JACK SHAFT GARAGE G-DOOR OPENER EP METERBASE FAN/LT ELECTRICAL PANEL/BASE FLUORESCENT/LED LIGHT SINK-TOP AIR PUSH SWITCH @ GARBAGE DISPOSAL SP © COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" E301 LOWER FLOOR ELECTRICAL PLAN EXT. PWDR U.C. & A.C. LTG, TYP.SSSS FAN ONLY SS SS U.C. & A.C. LTG, TYP.U.C. & A.C.LTG, TYP.U.C. & A.C.LTG, TYP.SSHIS SSSSS S PLAN ASSUMES 18" NOM. SECOND FLOOR STRUCTURE. BLDR TO VERIFY. GAME RM 10'-0" CLG RAILING, TYP. W D LAUNDRY 2 10'-0" CLG 5' T/S CATWALK 10'-0" CLG 26802680 QUEEN3060 SH8'-0" H.H.3060 SH8'-0" H.H.RAILING, TYP. BATH 6 10'-0" CLG 3-3060 FX MULL8'-0" H.H.3060 CSMNT 8'-0" H.H.3060 CSMNT8'-0" H.H.ATTIC ACCESS 24.5" X 54.5" UPPER FLOOR PLAN 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36)2-2080ENTRY OPEN TO ABV. STUDY 10'-0" CLG 2480 LINEN WC WC 3090 CO NON A/C AREA 10'-0" CLG STUDY CLOS.26802680 BATH 3 10'-0" CLG WIC 3 10'-0" CLG BDRM 3 10'-0" CLG 2880LIVING RM OPEN TO ABV. 2-2680 4020 FX 8'-0" H.H. 4020 FX 8'-0" H.H. 4020 FX 8'-0" H.H. 5080 CO 3080 UC REF A/C CHASE 3480 CO2040 SH 8'-0" H.H. WC BDRM 5 10'-0" CLG WIC 5 10'-0" CLG BATH 5 10'-0" CLG 288026802680 QUEEN WC 3060 SH8'-0" H.H.3060 SH 8'-0" H.H. BATH 4 10'-0" CLG WIC 4 10'-0" CLG 2680 2680BDRM 4 10'-0" CLG 3090 CO2480LINEN2880 HALL 10'-0" CLG ALL EXTERIOR WALLS TO BE 2x6 ALL EXTERIOR WALLS TO BE 2x6 ALL EXTERIOR WALLS TO BE 2x6 NON A/C AREA NON A/C AREA QUEEN 6030 FX 21'-7" H.H. 6030 FX 21'-7" H.H. 6030 FX 21'-7" H.H. LOFT 10'-0" CLG RAILING, TYP. 2-3070 FX MULL 18'-8" H.H.2x62x62x62x62x62x62x62x61 2 WALL W/ GLASS ABV. 2x6 2x62x62x82x8 2x6STRUCTURAL PONY WALL FOR RAISED FLOOR DIFFERENCE 2-3270 FX MULL 19'-8" H.H. 16 17 18 19 20 21 22 23 24 25 29 30 31 28 27 26 EGEG EG EG EG EG FLOOR PLAN NOTES:1.INTERIOR DIMENSIONS ARE TO FACE OF STUD, UNLESS GRAPHICALLY INDICATED OTHERWISE.WINDOWS AND DOORS ARE DIMENSIONED TO CENTERLINE OF ROUGH OPENINGS.2.REFER TO ELEVATIONS AND ROOF PLAN FOR PLATE HEIGHTS.3.CEILING HEIGHT CALL OUTS ARE NOMINAL. SEE ELEVATIONS AND ROOF PLAN FOR PRECISEDIMENSIONS.4.ALL ANGLES OTHER THAN 90° ANGLES ARE TO BE 45° ANGLES, U.O.N.5.ALL EGRESS HALLWAYS FROM BEDROOMS SHALL NOT BE RESTRICTED TO LESS THAN 3'-0” NET CLEAR.6.EXTERIOR BRICK WALLS (BRICK LEDGE) ARE SHOWN AS 5” WIDTH.7.ALL PLUMBING WALLS SHALL BE 2X6 MIN., U.O.N.8.THIS PLAN IS A GRAPHIC REPRESENTATION FOR ESTIMATING PURPOSES ONLY. ACTUAL FIELDCONDITIONS MAY VARY AND MUST BE VERIFIED BEFORE PROCEEDING WITH CONSTRUCTION.9.ALL GLAZING WITHIN 2'-0” HORIZONTAL DISTANCE FROM ANY JAMB OF EXTERIOR DOORS SHOULD BETEMPERED GLASS.10.GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT'S ATTIC AREA BY NOT LESS THAN 1/2"GYP. BOARD TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BYNOT LESS THAN 5/8" TYPE X GYP BOARD OR EQUIVALENT.11.ALL OPENINGS TO BE CENTERED ON WALLS U.O.N.12.STANDARD DOOR JAMB TO BE 4”.13.6" MIN DROP FROM FINISHED MATERIAL TO FINISHED GRADE; FINISHED GRADE TO SLOPE AWAYFROM FOUNDATION AT A 1/4" PER FOOT.© COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" UPPER FLOOR PLAN A102 2-3060 CSMNT MULL 8'-0" H.H. 15 A/C CHASE HDR ABV.23'-8" CLG COV'D PORCH 2x6 5' T/S ALL EXTERIOR WALLS TO BE 2x69'-10"2'-4"16'-2"4'-0"9'-4"14'-6"8'-4"4'-0"52'-4"6'-0"4'-8" 5'-10"6'-10" 2'-2" 3'-10"1'-4"22'-8"11'-0"13'-6" 12'-8"52'-4"5'-2" 3'-11"7'-2"7'-2"4'-5"11'-0"2'-6"12'-0"2'-6"6'-0"13'-8"2'-6"11'-2"19'-8"14'-6"5'-8"58'-4"16'-2"2'-4"7'-2"9'-0"15'-8"15'-2"5'-5"2'-0"8'-3"9'-11"13'-9" 6'-10"6'-11"4'-111 2"4'-111 2"4'-4"3'-11"7'-5"3'-0"4'-10"4'-10"3'-0"2'-6"11'-8" 1'-0"14'-2" 70'-2"2X12OVERHEA D OBSTRUCTIO N FLOOR TRUSS NOTES: 1. SEE FLOOR PLAN FOR NUMBER RISERS. 2. STAIRS ARE 3'-4" WIDE MIN. REFER TO FLOOR PLAN FOR WIDTH 3. NOSING IS 1" 4. HEADROOM ABOVE STAIRS SHALL NOT BE LESS THAN 6'-8" MEASURED VERTICALLY FROM THE SLOPED LINE ADJOINING THE TREAD NOSING. 5. HANDRAIL HEIGHT SHALL BE NOT LESS THAN 34" AND NOT MORE THAN 38". 6. GUARDS SHALL NOT ALLOW PASSAGE OF A 4" SPHERE. WHEN STORAGE UNDER STAIRS, BUILD WALL STARTS HERE. STAIRWAYS WITH 4 OR MORE RISERS REQUIRE A HANDRAIL 4"3'-0"8"34" MIN38" MAXTYP X GYP TO BE LOCATED UNDER STAIRS VARIESMAX 4" MAX SPACING AT BALUSTER, TYP.42" MIN HEIGHT AT GUARDRAILVARIESNOTE: BUILDER TO VERIFY NUMBER OF RISERS BASED ON SECOND FLOOR TRUSS SYSTEM STAIR DETAIL N.T.S. FF SUB-FLOOR 2X TREAD & RISER 1" NOSING 6'-8" MIN HEADROOM OF STAIR734"MAX10" MIN 13'-8"7"18'-7"1'-1"5'-11"15'-2" 6'-4"2'-8"4'-8"19'-2"10'-4"6'-4"4'-0"1'-10" 9'-0"4'-8"4'-2"22'-8"9'-0"4'-0"2'-0"2'-4"1'-2" 3'-2"2'-10"3'-6"4'-0"2'-0"5'-2"3'-10"1'-4"21'-4"4'-2"13'-8" 2'-6" 3'-10"4'-10"2'-4"13'-6"22'-8"1'-4"2'-10"6'-2"7'-6" 5'-2"1'-8"5'-10"3'-10"1'-4"22'-8"11'-0"13'-6"1'-4"14'-6"5'-2"2'-10"16'-2"8'-4"4'-0"6'-6"9'-0"6'-4"6'-2"3'-10"4'-4"2'-4"7'-6"1'-2"5'-6"4'-2"2'-4"13'-8"4'-10"4'-10"7'-10"2'-6"6'-6"3'-8"3'-8"8'-4"6'-0"18'-8"5'-2"20'-6"2'-10"8'-2"10'-4"4'-10"5'-8"8'-6"6'-4"3'-0"17'-10"4'-2"10"4'-0"4'-0"2'-0"8'-6"4'-0"2'-0"1'-8"1'-2"11'-2" 6'-0"5'-2" 14'-2"6'-6"6'-4"3'-4"7'-0"9'-2"5'-7"4'-5"4'-4"3'-0"6'-4" GAME RM LAUNDRY 2 CATWALK BATH 6 ATTIC ACCESS 24.5" X 54.5" UPPER FLOOR PLAN (ELECTRICAL) 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36) ENTRY STUDY NON A/C AREA STUDY CLOS. BATH 3 WIC 3 BDRM 3 LIVING RM A/C CHASE BDRM 5 WIC 5 BATH 5 BATH 4 WIC 4 BDRM 4 HALL NON A/C AREA NON A/C AREA LOFT BLDR TO VERIFY GAS/ELECTRIC HVAC AIR HANDLER UNIT HVAC PLATFORM TO SW BELOW FAN/LTSSSSS FAN/LT SS SSSS SS SSSSSSSSSSFAN/LT SSFAN/LT FAN ONLY SSSSCHAND TO LT BELOW SOFFIT PLUG SOFFIT PLUG SOFFIT PLUG SOFFIT PLUG SOFFIT PLUG CHAND TO SW BELOW TO SW BELOW TO SW BELOW © COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" E302 UPPER FLOOR ELECTRICAL PLAN A/C CHASE COV'D PORCH S SSSSSS SS S FF FF 12'-1" PLATE 6:12 22'-8" PLATE 12 6 12 6 12'-1" PLATE 12 6 12'-1" PLATE 24'-8" PLATE 23'-8" PLATE23'-8" PLATE 6:12 6:12 6:12 11'-1" PLATE6:12 FFFF 12'-1" PLATE12'-1" PLATE 6:12 6:12 12 6 12'-1" PLATE12'-1" PLATE 12 6 6:12 6:126:12 12 6 12 6 13'-1" PLATE 13'-1" PLATE 6:12 6:12 FRONT DOOR DESIGN IS A VISUAL REPRESENTATION. ACTUAL DOOR CHOSEN BY OWNER/BLDR. MAY DIFFER. DURING DESIGN PHASE. GARAGE DOOR DESIGN IS A VISUAL REPRESENTATION. ACTUAL DOOR CHOSEN BY OWNER/BLDR. MAY DIFFER. DURING DESIGN PHASE. STONE ROWLOCK, TYP.STONE, TYP. 3 COAT STUCCO, TYP. 6:12 6:12 6:12 2" TUBE STEEL BRACKET, TYP. S.S. METAL ROOF, TYP. 6:12 6'-0"3" STUCCO TRIM, TYP. FRONT ELEVATION 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36) GARAGE DOOR DESIGN IS A VISUAL REPRESENTATION. ACTUAL DOOR CHOSEN BY OWNER/BLDR. MAY DIFFER. DURING DESIGN PHASE. GARAGE ACCESS DOOR DESIGN IS A VISUAL REPRESENTATION. ACTUAL DOOR CHOSEN BY OWNER/BLDR. MAY DIFFER. DURING DESIGN PHASE. 6:12 RIGHT ELEVATION 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36)36'-0"6:126:12 20'-0"6'-0"EG EG EG EG EG 01 02 03 05 EGRESS OPENINGS: 1. WINDOWS: MIN. NET CLEAR OPENABLE AREA 5.7 SQFT (5.0 SQFT AT GRADE FLOOR). 2. MIN. NET CLEAR OPENABLE WIDTH 20". 3. MIN. NET CLEAR OPENABLE HEIGHT 24". 4. MAX. FINISHED SILL HEIGHT 44" ABOVE FINISHED FLOOR. 5. DOORS: MIN. CLEAR OPENING 32" WIDTH AND 78" HEIGHT. 6. EGRESS DOORS SHALL BE SIDE HINGED AND OPEN DIRECTLY TO EXTERIOR. 7. ALL EGRESS OPENINGS SHALL COMPLY WITH IRC R310 AND R311. EG ELEVATION NOTES:1.GUTTERS AND DOWNSPOUTS ARE NOT SHOWN FOR CLARITY. DOWNSPOUTS SHALL BE LOCATEDTOWARDS THE FRONT AND REAR OF THE HOUSE. LOCATE DOWNSPOUTS IN NON-VISUALLY OFFENSIVELOCATIONS, FOR EXAMPLE, FRONT WALL OF HOUSE, BESIDE PORCH COLUMNS, ETC. GENERALCONTRACTOR SHALL VERIFY EXISTING GRADES AND COORDINATE ANY NECESSARY ADJUSTMENTS TOHOUSE WITH OWNER.2.PLUMBING AND HVAC VENTS SHALL BE GROUPED IN AWAY FROM PUBLIC VIEW, I.E. AT THE REAR OFTHE HOUSE AND SHALL BE PRIMED AND PAINTED TO MATCH ROOF COLOR.3.PROVIDE ATTIC VENTILATION PER LOCAL CODE REQUIREMENTS.4.EXTERIOR FLASHING SHALL BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS,WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTIONPRACTICES.5.CONTRACTOR SHALL PROVIDE ADEQUATE ATTIC VENTILATIONS/ROOF VENTS PER LOCALGOVERNING PROVIDE APPROPRIATE SOFFIT VENTILATION AT OVERHANGS.1 2 3 4 5 6 7 8 16 17 18 19 20 21 22 23 24 8" 2'-0" 2'-0" 2'-0"2'-0" 2'-0" 4:12 CRICKET © COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" FRONT & RIGHT ELEVATIONS A103 EG 15 6:12 6:12 6:12 6:12 6:12 11'-4"NOTE: CHIMNEY TO EXTND 2'0" HIGHER THAN ANY PORTION OF BUILDING WITHIN 10'0", BUT NOT LESS THAN 3'0" ABOVE POINT WHERE CHIMNEY PASSES THROUGH ROOF. 8" 6:12 23'-8" PLATE 12 6 12 6 12 6 12 6 2'-0"2'-0" 12 6 23'-8" PLATE23'-8" PLATE 3:12 25'-4" PLATE 8" 6:12 6:12 6:12 23'-8" PLATE 23'-8" PLATE 12 6 23'-8" PLATE 6:12 6:126:1224'-8" PLATE 6:12 6:12 12 6 2'-0"2'-0" 6:12 12 6 6:12 2'-0" 12 3 25'-4" PLATE 12 3 S.S. METAL ROOF 3:12 FFFF 12'-1" PLATE 12 66:12 12'-1" PLATE 12 6 6:12 6:12 12'-1" PLATE 12 6 12'-1" PLATE FFFF 12 6 12'-1" PLATE 6:12 6:12 12 6 4:12 4:12 4:12 12'-1" PLATE 23'-8" PLATE 12 6 23'-8" PLATE 12'-1" PLATE 12 6 12'-1" PLATE12'-1" PLATE 4:12 4:12 4:12 6:12 23'-8" PLATE 12 6 13'-1" PLATE 6:12 6:12 12 6 PATIO DOOR DESIGN IS A VISUAL REPRESENTATION. ACTUAL DOOR CHOSEN BY OWNER/BLDR. MAY DIFFER. DURING DESIGN PHASE. S.S. METAL ROOF LEFT ELEVATION 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36) REAR ELEVATION 1/8" = 1'-0" (11x17) 1/4" = 1'-0" (24x36)1'-6"PLAN ASSUMES 18" NOM. SECOND FLOOR STRUCTURE. BLDR TO VERIFY. CONTROL JOINT EG EG EG 07 EGRESS OPENINGS: 1. WINDOWS: MIN. NET CLEAR OPENABLE AREA 5.7 SQFT (5.0 SQFT AT GRADE FLOOR). 2. MIN. NET CLEAR OPENABLE WIDTH 20". 3. MIN. NET CLEAR OPENABLE HEIGHT 24". 4. MAX. FINISHED SILL HEIGHT 44" ABOVE FINISHED FLOOR. 5. DOORS: MIN. CLEAR OPENING 32" WIDTH AND 78" HEIGHT. 6. EGRESS DOORS SHALL BE SIDE HINGED AND OPEN DIRECTLY TO EXTERIOR. 7. ALL EGRESS OPENINGS SHALL COMPLY WITH IRC R310 AND R311. EG ELEVATION NOTES:1.GUTTERS AND DOWNSPOUTS ARE NOT SHOWN FOR CLARITY. DOWNSPOUTS SHALL BE LOCATEDTOWARDS THE FRONT AND REAR OF THE HOUSE. LOCATE DOWNSPOUTS IN NON-VISUALLY OFFENSIVELOCATIONS, FOR EXAMPLE, FRONT WALL OF HOUSE, BESIDE PORCH COLUMNS, ETC. GENERALCONTRACTOR SHALL VERIFY EXISTING GRADES AND COORDINATE ANY NECESSARY ADJUSTMENTS TOHOUSE WITH OWNER.2.PLUMBING AND HVAC VENTS SHALL BE GROUPED IN AWAY FROM PUBLIC VIEW, I.E. AT THE REAR OFTHE HOUSE AND SHALL BE PRIMED AND PAINTED TO MATCH ROOF COLOR.3.PROVIDE ATTIC VENTILATION PER LOCAL CODE REQUIREMENTS.4.EXTERIOR FLASHING SHALL BE CORRECTLY INSTALLED AT ALL CONNECTIONS BETWEEN ROOFS,WALLS, CHIMNEYS, PROJECTIONS AND PENETRATIONS AS REQUIRED BY APPROVED CONSTRUCTIONPRACTICES.5.CONTRACTOR SHALL PROVIDE ADEQUATE ATTIC VENTILATIONS/ROOF VENTS PER LOCALGOVERNING PROVIDE APPROPRIATE SOFFIT VENTILATION AT OVERHANGS.9 11 12 13 14 25 29 30 31 282726 2'-0"2'-0" 2'-0" 2'-0"2'-0"2'-0" 8" © COPYRIGHT 2026 SINGLE TWIST STUDIO, LLC 2x4 SIDING WALL 2x6 SIDING WALL 11"9"6"4"8"10"2x4 LUEDER SLAB STONE EXTERIOR WALL 2x6 LUEDER SLAB STONE EXTERIOR WALL 2x4 MASONRY EXTERIOR WALL 2x6 MASONRY EXTERIOR WALL THESE PLANS ARE INTENDED TO PROVIDE THE BASIC CONSTRUCTION INFORMATION NECESSARY TO SUBSTANTIALLY COMPLETE THIS STRUCTURE. THESE PLANS MUST BE VERIFIED AND CHECKED BY THE BUILDER OR THE PERSON IN AUTHORITY OF THIS PROJECT. ANY DISCREPANCY, ERROR, AND/OR OMISSION, IF FOUND, IS TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE DESIGNER BEFORE ANY CONSTRUCTION IS COMMENCED OR PURCHASES MADE. IT IS RECOMMENDED THAT THE OWNER OR BUILDER OBTAIN COMPLETE ENGINEERING SERVICES; FOUNDATION, HVAC, AND STRUCTURAL, BEFORE BEGINNING CONSTRUCTION OF ANY KIND. ALL FEDERAL, STATE, AND LOCAL CODES, ORDINANCES, AND RESTRICTIONS TAKE PRECEDENCE OVER THESE PLANS. ANY CONFLICT MUST BE ADDRESSED AND RESOLVED IN ACCORDANCE WITH THOSE REQUIREMENTS AND MUST BE STRICTLY OBEYED AND FOLLOWED BEFORE AND DURING CONSTRUCTION. THESE PLANS MAY ONLY BE USED FOR THE CONSTRUCTION OF THE SPECIFIC PROJECT ADDRESS FOR WHICH THEY WERE CREATED AND MAY NOT BE REUSED, COPIED, OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT WRITTEN CONSENT FROM SINGLE TWIST STUDIO. PROJECT VERSION DATE NOTES SCALE WALL LEGEND1088 WESTPARKCIRCLE SSUBDIV: I.G. BELCHER LOT: --BLOCK: -- SOUTHLAKE,TX DENTON COUNTY 03.16.2026 12.17.2025 - v1 12.30.2025 - A 01.05.2026 - B 01.12.2026 - B1 01.15.2026 - C 02.07.2026 - C1 02.28.2026 - C2 03.31.2026 - D 04.02.2026 - D1 04.06.2026 - E 04.16.2026 - E1 1/4"=1'-0" REAR & LEFT ELEVATIONS A104 B&B SIDING, TYP. 6:12 6:12 9'-8"0608 NOTE: CHIMNEY TO EXTND 2'0" HIGHER THAN ANY PORTION OF BUILDING WITHIN 10'0", BUT NOT LESS THAN 3'0" ABOVE POINT WHERE CHIMNEY PASSES THROUGH ROOF. 12 3 23'-8" PLATE 12 6 23'-8" PLATE 6:12 6:126:12 6:12 2'-0" 25'-4" PLATE 1'-0" 12 6 12 6 12 6 23'-8" PLATE 6:12 23'-8" PLATE 12 6 12 6 23'-8" PLATE 12 6 6:12 6:12 6:12 6:12 6:12 6:12 6:126:12 6:12 12 6 2'-0"2'-0"