Loading...
Item 9 SOUTHLAKE PLANNING & DEVELOPMENT SERVICES STAFF REPORT December 31, 2020 CASE NO: ZA20-0063 PROJECT: Specific Use Permit for a Residential Solar Energy System EXECUTIVE SUMMARY: Momentum Solar, on behalf of the owner Michael Kwong, is requesting approval of a Specific Use Permit for a Residential Solar Energy System on property described as Lot 27, Block 7, Myers Meadow Addition, City of Southlake, Tarrant County, Texas and located at 1909 Water Lily Drive, Southlake,Texas. Current Zoning: "R- PUD" Residential Planned Unit Development District. SPIN Neighborhood #6. DETAILS: The applicant is requesting approval to install a residential solar energy system to be located on south and west rear roofs of the house. The proposed solar array for the house consists of 19 solar energy panels (each panel is approximately 40.5" by 68.5") totaling approximately 366 square feet. The proposed system produces 6.46 kW. Additional information may be found in the specific use permit plans. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Specific Use Permit Request for a Residential Solar Energy System ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Specific Use Permit Staff Review No. 2 dated December 31, 2020 (D) Surrounding Property Owners Map (E) Surrounding Property Owners Responses (F) Resolution No. 20-056, Specific Use Permit for a Residential Solar Energy System Full Size Plans (for Commission and Council Members only) PowerPoint Presentation Plans STAFF CONTACT: Dennis Killough (817) 748-8072 Patty Moos (817) 748-8269 Case No. ZA20-0063 BACKGROUND INFORMATION APPLICANT: Momentum Solar OWNER: Michael Kwong PROPERTY SITUATION: 1909 Water Lily Drive, Southlake, Texas LEGAL DESCRIPTION: Lot 27, Block 7, Myers Meadow Addition LAND USE CATEGORY: Medium Density CURRENT ZONING: "R-PUD" Residential Planned Unit Development District TRANSPORTATION ASSESSMENT: This request does not affect traffic on or around the property. TREE PRESERVATION: The proposed solar panels are to be installed on the rear and side rear roof of the house; no trees will be affected by the request. STAFF COMMENTS: Staff Review may be found in the Specific Use Permit Summary No. 2 dated December 31, 2020. Note: A specific use permit shall automatically expire if a building permit is not issued and construction begun within six (6) months of the granting of the specific use permit or if the use shall cease for a period of six (6) months. 45.5 FACTORS TO BE CONSIDERED - In granting or denying an application for a specific use permit, the City Council shall take into consideration the following factors: a. Safety of the motoring public and of pedestrians using the facility and the area immediately surrounding the site. b. Safety from fire hazard, and measures for fire control. C. Protection of adjacent property from flood or water damage. d. Noise producing elements; and glare of vehicular and stationary lights and effect of such lights on established character of the neighborhood. e. Location, lighting and type of signs; and relation of signs to traffic control and adverse effect on adjacent properties. f. Street size and adequacy of pavement width for traffic and reasonably expected to be generated by the proposed use around the site and in the immediate neighborhood. g. Adequacy of parking, as determined by requirements of this Case No. Attachment A ZA20-0063 Pagel chapter for off-street parking facilities for similar uses; location of ingress and egress points for parking and off- street loading spaces; and protection of the public health by all-weather surfacing on all parking areas to control dust. h. Such other measures as will secure and protect the public health, safety, morals and general welfare. i. City Council may grant variances to specific regulations associated with a specific use set forth in Sections 45. To receive a variance, the applicant must demonstrate one of the following (As amended by Ordinance No.480-MMMM): (a) A variance will reduce the impact of the project on surrounding residential properties; or (b) Compliance with this ordinance would impair the architectural design or creativity of the project; or (c) A variance is necessary to assure compatibility with surrounding developed properties; or (d) The proposed construction is an addition to an existing project that does not meet the requirements of this ordinance. 45.17 SPECIFIC REGULATIONS FOR SOLAR ENERGY SYSTEMS(As amended by Ordinance No. 480-WWW) The purpose of this section is to establish standards for Solar Energy Systems. A Solar Energy System shall be approved by City Council through the Specific Use Permit process and may be subject to other requirements as deemed necessary. RESIDENTIAL ZONES Ground Mounted Systems: a. Front Yard: No system shall be located forward of the principal building on the lot. b. Side and Rear: No system shall be located less than ten (10)feet from any side or rear property line. Roof Mounted Systems: a. Height: No system shall be installed greater than six(6) inches between the panel and roof. ALL ZONES a. No solar energy system shall be constructed upon a lot until a building permit has been issued or principal use has actually been commenced. b. A line of sight analysis will be required in addition to the applicable submittal Case No. Attachment A ZA20-0063 Page 2 requirements under Section 40 (Development Plans and Site Plans)of the City of Southlake Zoning Ordinance. C. Solar photovoltaic power systems must comply with Section 1204 of the 2018 International Fire Code. MCommunity DevelopmenhMEMO12020 CasesO063-SUP- 1909 Water Lily Drive Case No. Attachment A ZA20-0063 Page 3 Vicinity 1 p 1909 Water Lily Drive 2302 L2300 ] F 2305 2303 �x+ 1 1808 1804 1802 1800 MESQUITE fo c. rp -4 31 230 °° � `- LP CD 7 2313 230 'L` 220 -ll- 191 '1601 nx 218 ` 221 1 22'D8 2 2300 216 17 219 -� P 11,LM� 1D 214 215 1906 1 190 s DOW T 217 230 I 212 213 190"1'10 216 �v LL 210 211 21 209 209 1 190 190 z1f 206 207 F2 T' D 204 205 202 203a' o ZA20-0063 Specific Use Permit - 0 90 180 360 Feet Case No. Attachment B ZA20-0063 Page 1 SPECIFIC USE PERMIT REVIEW SUMMARY Case No.: ZA20-0063 Review No.: Two Date of Review:12/31/20 Project Name: Specific Use Permit for a Residential Solar Panel System APPLICANT: Momentum Solar OWNER: Michael Kwong Fed Bayona 1909 Water Lily Drive Dallas, TX 75220 Southlake, TX 76092 Phone: 512-213-1546 ext. 1287 Phone: 415-653-6198 Email: fbayona(@momentumsolar.com Email: mkwong@gmail.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 11/30/20 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT Patty Moos AT(817)748- 8269. Planning Review Patty Moos Planner Phone: (817) 748-8269 Email: pmoos(a-)ci.southlake.tx.us NOTE: A building permit must be issued prior to installation of the solar panels. NOTE: A specific use permit shall automatically expire if a building permit is not issued and construction begun within six (6) months of the granting of the specific use permit or if the use shall cease for a period of six (6) months Fire Department Kelly Clements Fire Marshal Phone: (817) 748-8233 E-mail: kclements@ci.southlake.tx.us GENERAL COMMENTS: Solar photovoltaic power systems must comply with Section 1204 of the 2018 International Fire Code. General Information 45.17 SPECIFIC REGULATIONS FOR SOLAR ENERGY SYSTEMS(As amended by Ordinance No. 480-WWW) The purpose of this section is to establish standards for Solar Energy Systems. A Solar Energy Case No. Attachment C ZA20-0063 Page 1 System shall be approved by City Council through the Specific Use Permit process and may be subject to other requirements as deemed necessary. RESIDENTIAL ZONES Ground Mounted Systems: C. Front Yard: No system shall be located forward of the principal building on the lot. d. Side and Rear: No system shall be located less than ten (10)feet from any side or rear property line. Roof Mounted Systems: b. Height: No system shall be installed greater than six(6) inches between the panel and roof. ALL ZONES d. No solar energy system shall be constructed upon a lot until a building permit has been issued or principal use has actually been commenced. e. A line of sight analysis will be required in addition to the applicable submittal requirements under Section 40 (Development Plans and Site Plans)of the City of Southlake Zoning Ordinance. 2018 INTERNATIONAL FIRE CODE SECTION 1204 SOLAR PHOTOVOLTAIC POWER SYSTEMS 1204.1 General. Solar photovoltaic systems shall be installed in accordance with Sections 1204.2 through 1204.5, and the International Building Code or International Residential Code. The electrical portion of solar PV systems shall be installed in accordance with NFPA 70. 1204.2 Access and pathways. Roof access, pathways, and spacing requirements shall be provided in accordance with Sections 1204.2.1 through 1204.3.3. Pathways shall be over areas capable of supporting fire fighters accessing the roof. Pathways shall be located in areas with minimal obstructions, such as vent pipes, conduit or mechanical equipment. Exceptions: 1. Detached, non-habitable Group U structures including, but not limited to, detached garages serving Group R-3 buildings, parking shade structures, carports, solar trellises and similar structures. 2. Roof access, pathways and spacing requirements need not be provided where the fire code official has determined that rooftop operations will not be employed. 1204.2.1 Solar photovoltaic systems for Group R-3 buildings. Solar photovoltaic systems for Group R-3 buildings shall comply with Sections 1204.2.1.1 through 1204.2.1.3. Case No. Attachment C ZA20-0063 Page 2 Exceptions: 1. These requirements shall not apply to structures designed and constructed in accordance with the International Residential Code. 2. These requirements shall not apply to roofs with slopes of 2 units vertical in 12 units horizontal or less. 1204.2.1.1 Pathways to ridge. Not fewer than two 36- inch-wide (914 mm) pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, not fewer than one 36-inch-wide(914 mm)pathway from lowest roof edge to ridge shall be provided on the same roof plane as the photovoltaic array, on an adjacent roof plane or straddling the same and adjacent roof planes. 1204.2.1.2 Setbacks at ridge. For photovoltaic arrays occupying 33 percent or less of the plan view total roof area, a setback of not less than 18 inches (457 mm) wide is required on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 33 percent of the plan view total roof area, a setback of not less than 36 inches (457 mm) wide is required on both sides of a horizontal ridge. 1204.2.1.3 Alternative setbacks at ridge. Where an automatic sprinkler system is installed within the dwelling in accordance with Section 903.3.1.3, set-backs at the ridge shall conform to one of the following: 1. For photovoltaic arrays occupying 66 percent or less of the plan view total roof area, a setback of not less than 18 inches (457 mm) wide is required on both sides of a horizontal ridge. 2. For photovoltaic arrays occupying more than 66 percent of the plan view total roof area, a setback of not less than 36 inches (914 mm) wide is required on both sides of a horizontal ridge. 1204.2.2 Emergency escape and rescue openings. Panels and modules installed on Group R-3 buildings shall not be placed on the portion of a roof that is below an emergency escape and rescue opening. A pathway of not less than 36 inches (914 mm) wide shall be provided to the emergency escape and rescue opening. 1204.3 Other than Group R-3 buildings. Access to systems for buildings, other than those containing Group R-3 occupancies, shall be provided in accordance with Sections 1204.3.1 through 1204.3.3. Exception: Where it is determined by the fire code official that the roof configuration is similar to that of a Group R-3 occupancy, the residential access and ventilation requirements in Sections 1204.2.1.1 through 1204.2.1.3 are a suitable alternative. 1204.3.1 Perimeter pathways. There shall be a minimum 6-foot-wide (1829 1 mn) clear perimeter around the edges of the roof. Exception: Where either axis of the building is 250 feet (76 200 mm) or less, the clear perimeter around the edges of the roof shall be permitted to be reduced to a minimum width of 4 feet (1219 mm). Case No. Attachment C ZA20-0063 Page 3 1204.3.2 Interior pathways. Interior pathways shall be provided between array sections to meet the following requirements: 1. Pathways shall be provided at intervals not greater than 150 feet (45 720 mm) throughout the length and width of the roof. 2. A pathway not less than 4 feet (1219 mm) wide in a straight line to roof standpipes or ventilation hatches. 3. A pathway not less than 4 feet (1219 mm) wide around roof access hatches, with not fewer than one such pathway to a parapet or roof edge. 204.3.3 Smoke ventilation. The solar installation shall be designed to meet the following requirements: 1. Where non-gravity operated smoke and heat vents occur, a pathway not less than 4 feet (1219 mm)wide shall be provided bordering all sides. 2. Smoke ventilation options between array sections shall be one of the following: 2.1. A pathway not less than 8 feet (2438 mm) wide. 2.2. Where gravity-operated dropout smoke and heat vents occur, a pathway not less than 4 feet (1219 mm) wide on not fewer than one side. 2.3. A pathway not less than 4 feet (1219 1 mn) wide bordering 4-foot by 8-foot (1219 mm by 2438 mm) venting cutouts every 20 feet(6096 mm) on alternating sides of the pathway. 1204.4 Ground-mounted photovoltaic panel systems. Ground-mounted photovoltaic panel systems shall comply with Section 1204.1 and this section. Setback requirements shall not apply to ground-mounted, free-standing photovol-taic arrays. A clear, brush-free area of 10 feet (3048 mm) shall be required for ground-mounted photovoltaic arrays. 1204.5 Buildings with rapid shutdown. Buildings with rapid shutdown solar photovoltaic systems shall have perma-nent labels in accordance with Sections 1204.5.1 through 1204.5.3. 1204.5.1 Rapid shutdown type. The type of solar photo-voltaic system rapid shutdown shall be labeled with one of the following: 1. For solar photovoltaic systems that shut down the array and the conductors leaving the array, a label shall be provided. The first two lines of the label shall be uppercase characters with a minimum height of 3/4- inch (10 mm) in black on a yellow background. The remaining characters shall be uppercase with a minimum height of 3/16 inch (5mm) in black on a white background. The label shall be in accordance with Figure 1204.5.1(1) and state the following: SOLAR PV SYSTEM EQUIPPED WITH RAPID SHU1 DOWN. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" Case No. Attachment C ZA20-0063 Page 4 POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY. SOLA-R PV SYSTEM. EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM -_ AND REDUCE SHOCK HAZARD IN ARRAY FIGURE 12045.1(1) LABEL FOR SOLAR PV SYSTEMS THAT REDUCE SHOCK HAZARD WITHIN ARRAY AND SHUT DOWN CONDUCTORS LEAVING ARRAY 2. For photovoltaic systems that only shut down con-ductors leaving the array, a label shall be provided. The first two lines of the label shall be uppercase characters with a minimum height of 3/8 inch (10mm) in white on a red background and the remaining characters shall be capitalized with a minimum height of 3/16 inch (5 mm) in black on a white background. The label shall be in accordance with Figure 1204.5.1(2) and state the following: THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUC-TORS OUTSIDE THE ARRAY. CONDUC-TORS WITHIN ARRAY REMAIN ENERGIZED IN SUNLIGHT. 1204.5.1.1 Diagram. The labels in Section 1204.5.1 shall include a simple diagram of a building with a roof. Diagram sections in red signify sections of the solar photovoltaic system that are not shut down when the rapid shutdown switch is turned off. 1204.5.1.2 Location. The rapid shutdown label in Section 1204.5.1 shall be located not greater than 3 feet(914 mm)from the service disconnecting means to which the photovoltaic systems are connected and shall indicate the location of all identified rapid shut-down switches if not at the same location. 204.5.2 Buildings with more than one rapid shutdown type. Solar photovoltaic systems that contain rapid shut-down in accordance with both Items 1 and 2 of Section 1204.5.1 or solar photovoltaic systems where only por-tions of the systems on the building contain rapid shut-down, shall provide a detailed plan view diagram of the roof showing each different photovoltaic system and a dot-ted line around areas that remain energized after the rapid shutdown switch is operated. Case No. Attachment C ZA20-0063 Page 5 1204.5.3 Rapid shutdown switch. A rapid shutdown switch shall have a label located not greater than 3 feet (914 mm) from the switch that states the following: RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TURN RAPID SHUTDOWN `± v SWITCHTOTHE"OFF" S'' POSITION TO '' SHUT DOWN CONDUCTORS 1� ---------- OUTSIDE THE ARRAY. Ii CONDUCTORS WITHIN r� ARRAY REMAIN ENERGIZED IN SUNLIGHT ROURE 1204J5.1(2) LABEL FOR SOLAR PV SYSTEMS THAT ONLY SHUT DOWN CON DUCTORS LEAVING THE ARRAY Case No. Attachment C ZA20-0063 Page 6 Surrounding Property Owners Residential Solar Energy System 1 1806 1804 11802 11800 O 1109 f E ITF QT >> w w � 1 1800 �L 11� 2 � E 191 o N 190 1801 0 2 221 �0 171 111 0 11 2 zn 219 D 2144,215 1906 190 190 � 217 212 213 9° W 190 190 215 171 a LL 210 211 213 1 208 209 19 op 190 1 211 Y 206 207 CT �o o 204 205 202 203 yOti $ O N C) O 60 iZ O o O rn o 0 � 00 o JO v SPO# Owner Zoning Site Address Acreeag Response 1. MYERS MEADOW HOA RPUD 1800 WATER LILY DR 1.06 NR 2. XIAO, FENG RPUD 1716 WATER LILY DR 0.33 NR 3. DALTON, STEPHEN RPUD 1718 WATER LILY DR 0.32 NR 4. SIMMONS REVOCABLE TRUST RPUD 1720 WATER LILY DR 0.33 NR 5. YUE, CHUN KEUNG RPUD 303 LOVEGRASS LN 0.37 NR 6. BLUE KEY LIVING TRUST RPUD 1722 WATER LILY DR 0.30 NR 7. SAYERS, BRENDAN G RPUD 1724 WATER LILY DR 0.30 NR 8. KENG,JANE RPUD 1900 WATER LILY DR 0.34 NR 9. WANG, FEI RPUD 1902 WATER LILY DR 0.30 NR 10. GARNER, BRIAN RPUD 1904 WATER LILY DR 0.31 O 11. WU, DANIEL RPUD 1906 WATER LILY DR 0.34 NR 12. SMALL,JULIET RPUD 1908 WATER LILY DR 0.33 NR 13. LEE,JAE Y RPUD 222 BOB O LINK DR 0.44 NR 14. HAWBAKER HOLDINGS LLC RPUD 301 LOVEGRASS LN 0.39 NR 15. ROELLER, PAUL T RPUD 1717 WATER LILY DR 0.33 NR 16. QUINTANILLA,JOSE RPUD 220 BOB O LINK DR 0.34 NR 17. THOMPSON,JEFFREY E RPUD 210 SWALLOW DR 0.33 NR 18. MEHAN, TOM RPUD 211 MEADOW LARK LN 0.36 NR 19. JARUGUMILLI, SHARATH RPUD 1907 WATER LILY DR 0.33 NR 20. DUMA, HYDAJET RPUD 1905 WATER LILY DR 0.32 NR Case No. Attachment D ZA20-0063 Page 1 21. PASTUSZEK HOLLAND, SARAH RPUD 1909 WATER LILY DR 0.30 NR 22. NARASIMHAN, ASHWIN RPUD 1903 WATER LILY DR 0.31 NR 23. DAMM, SEAN P RPUD 223 LOVEGRASS LN 0.33 NR 24. SETFORD, IAN K RPUD 1911 WATER LILY DR 0.33 NR 25. GOCAY, MURAT RPUD 1901 WATER LILY DR 0.32 NR 26. STILLER, ROBERT A RPUD 218 BOB O LINK DR 0.35 NR 27. KALPATHY,SATISH RPUD 221 LOVEGRASS LN 0.33 NR 28. RODRIGUEZ,J HECTOR RPUD 216 BOB O LINK DR 0.35 NR 29. RIMMALAPUDI,S RPUD 217 BOB O LINK DR 0.31 NR 30. LINDHOLM,THOMAS E RPUD 1900 HAY MEADOW CT 0.32 NR 31. WILLIAMS, RABUN RPUD 1902 HAY MEADOW CT 0.32 NR 32. SANDERS, MARY RPUD 1904 HAY MEADOW CT 0.33 NR 33. OLOHAN, WILLIAM A RPUD 1906 HAY MEADOW CT 0.42 NR 34. SCHWARTZ, CHRISTOPHER J RPUD 219 LOVEGRASS LN 0.32 NR 35. CHATURVEDI, PURNIMA RPUD 214 BOB O LINK DR 0.34 NR 36. KULKARNI, ABHIJIT RPUD 215 BOB O LINK DR 0.30 NR 37. JUDGE, RYAN G RPUD 217 LOVEGRASS LN 0.32 NR 38. LE,TRANG RPUD 212 BOB O LINK DR 0.34 NR 39. DUNN, MONICA RPUD 213 BOB O LINK DR 0.32 NR 40. BENNETT,TAMARA RPUD 1907 HAY MEADOW CT 0.34 NR 41. MANGAT, MANMEET RPUD 215 LOVEGRASS LN 0.32 NR 42. HARRIS, SCOTT S RPUD 1903 HAY MEADOW CT 0.32 NR 43. LEE, SANDY J L HEH RPUD 1901 HAY MEADOW CT 0.32 NR 44. MOSSBERG, ELLEN M RPUD 1905 HAY MEADOW CT 0.35 NR 45. AMERI HOMES 4 RENT PROP RPUD 210 BOB O LINK DR 0.35 NR 46. WINKLER, DAVID RPUD 211 BOB O LINK DR 0.32 NR 47. CASPERSON, ESTELA E RPUD 213 LOVEGRASS LN 0.34 NR 48. YIN, KUNSONG RPUD 1905 RED CEDAR CT 0.34 NR 49. NEDUNCHELIAN, BHARATH RPUD 1900 RED CEDAR CT 0.39 NR 50. TAYLOR, GARY M RPUD 1902 RED CEDAR CT 0.32 NR 51. SMITH, LARRY RPUD 1904 RED CEDAR CT 0.36 NR 52. XU, BIQIANG RPUD 208 BOB O LINK DR 0.34 NR 53. HOPPER, LISA D RPUD 211 LOVEGRASS LN 0.38 NR 54. BRACKEN, LAWRENCE RPUD 209 BOB O LINK DR 0.32 NR 55. BIPINCHANDRA AND BHARATI RPUD 209 LOVEGRASS LN 0.39 NR DESAI 56. MILLENNIUM PROPERTY ACQ RPUD 206 BOB O LINK DR 0.35 NR 57. FAUSAK,ANDREW RPUD 207 BOB O LINK DR 0.32 NR 58. GARLITZ,J I M RPUD 207 LOVEGRASS LN 0.33 NR 59. YOUNG, RUSSELL A RPUD 1903 RED CEDAR CT 0.32 NR 60. DU, DAWEI RPUD 204 LOVEGRASS LN 0.34 NR 61. JOSHI, DEEPAK RPUD 205 BOB O LINK DR 0.32 NR 62. WILLIAMS, ROBERT RPUD 204 BOB O LINK DR 0.34 NR 63. MCCABE LIVING TRUST RPUD 205 LOVEGRASS LN 0.33 NR 64. MEDINA, SHEILA RPUD 202 LOVEGRASS LN 0.34 NR 65. HAWBAKER, LINDSAY RPUD 200 LOVEGRASS LN 0.34 NR 66. WU,AIMEI RPUD 203 BOB O LINK DR 0.32 NR Case No. Attachment D ZA20-0063 Page 2 67. NG, BENJAMIN RPUD 202 BOB O LINK DR 0.35 NR 68. SALEEB,ASH RAF RPUD 203 LOVEGRASS LN 0.33 NR 69. CARROLL,JEFFERY RPUD 107 CLEAR BROOK CT 0.41 NR 70. SERIS,JODI RPUD 201 BOB O LINK DR 0.32 NR 71. TANDANG, PAULUS RPUD 200 BOB O LINK DR 0.34 NR 72. MCCLEAN, KEVIN RPUD 106 CLEAR BROOK CT 0.35 NR 73. DURRETT, STEVEN L RPUD 105 CLEAR BROOK CT 0.36 NR 74. BURT, NAPOLEON RPUD 105 BOB O LINK CT 0.34 NR 75. PAPA,JOHN P RPUD 106 BOB O LINK CT 0.33 NR 76. SALISBURY, NANCY RPUD 104 CLEAR BROOK CT 0.34 NR 77. HAMILTON,JOHN S RPUD 103 CLEAR BROOK CT 0.30 NR 78. GUIRGUIS, MEDHAT RPUD 103 BOB O LINK CT 0.32 U 79. ORTIZ, MONICA RPUD 104 BOB 0 LINK CT 0.35 NR 80. LILLY, CHARLES W RPUD 101 CLEAR BROOK CT 0.43 NR 81. SWANSON, DANIEL RPUD 100 CLEAR BROOK CT 0.49 NR 82. MAHAMUD, KARINA R RPUD 1910 WATER LILY DR 0.33 NR 83. ISLAM, MOHAMMAD S RPUD 101 BOB 0 LINK CT 0.42 NR 84. DECKER, BLAISE C RPUD 100 BOB O LINK CT 0.50 NR 85. MYERS MEADOW HOA RPUD 1970 W SOUTH LAKE BLV 4.22 NR 86. BROWN, MICHAEL RPUD 102 CLEAR BROOK CT 0.39 NR 87. HERNANDEZ FAMILYTRUST RPUD 102 BOB O LINK CT 0.45 NR 88. KWONG, MICHAEL RPUD 1909 WATER LILY DR 0.30 NR 89. Supt of Carroll ISD NR 90 Supt of Grapevine Colleyville NR ISD 91. Supt of Northwest ISD NR 92. Supt of Keller ISD NR Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Ninety-one (91) Responses Received: In Favor: 0 Opposed: 1 Undecided: 1 No Response: 89 Case No. Attachment D ZA20-0063 Page 3 Surrounding Property Owners Responses Not�flca# n Rssponsd F4 n ZA2o-o063 Meeting Date. alhu#7 . 0 1 dta:3Q MA GUIRDUIS.IMtt[,�1iA7 103 BO$O LINK'gT 450Uf11J�K�7X 7¢Q92 PLF/1SE Pl Vli FQkM3 Y!A'. SAX OR.14AND DELIVERY FIEFORE'�'1l� T�k 'd rHE$LF�EDULED PUE3LIC HEARING. Bing the owmer(��ofthe property so.noted above, are hereby in favor df opposed to undecided about iarcie or urideriine.one) the ptposed Specific Use.Perm'it referenced above. Sjs4 for comments regarding your position: Signature' Oate. 1l? ? . Addrhona!Signature: Date-. `' aepinpert�!.aiui�ehgwhm name#vre pied atop. Otherwise the Plar+are9 acPa�r ' Cne iomi PC r pro Wo"I geny. 4 phone Number(opt onajl)•,:' �1 Case No. Attachment E ZA20-0051 Page 1 Notification Response Form Direct questions a aid responses t ZA20-0063 City of Southlake ,y ___ Meeting Date: January 7, 2021 at 6:30 PM Planning 8 DevelopmenferVtces — - Notification Response 1400 Main St; Ste 310 GARNER, BRIAN Southlake,TX 76092 1904 WATER LILY DR Phone: (817)748-8621 SOUTHLAKE, TX 76092 Fax: (817)748-8077 PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed t?o undecided about (circle or underline one) the proposed Specific Use Permit referenced above. Space for comments regarding your position: C1�'�'1 �i,� C;.�ki.� �ih�'�il (�I`ti�r;,� _ c,:1;� �,,y; r �l=ih � :-!�_ ►�i,t.} ( ,'Ys(;t'ct�?:.!1.�• �i^rn ��✓ `�f�S } 1 �'r' l�. (,►�,�.t(e i(��`L G �1 f.n,�,' I}�:.�'n�{'7 +i'1 1t.v'-7+ a �� c fly 1\��11 I(l (:fit '�,���'��'. 't'� ..L�� ��1J '!�I��L� I � i I. 1� •� �I,�',I� v""iJ l-twuk -6 tu V 1 � l F lw.`' L Signature: Date: l�-���X Additional Signature: C ! tL,.`jr>�=:��_F�!' Date: ; 7 .? -4 Printed Name(s): h1'16, t L i c Lri1 :.i7f" Must be property caner{;}v:hosc namei's;are painted at too Uthe-mse contact the Planning Department. One form pur property Phone Number (optional): 2 11f Case No. Attachment E ZA20-0051 Page 2 RESOLUTION NO. 20-056 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS, GRANTING A SPECIFIC USE PERMIT FOR A SOLAR ENERGY SYSTEM ON RESIDENTIAL PROPERTY WITHIN THE CITY OF SOUTHLAKE, TEXAS LOT 27, BLOCK 7, MYERS MEADOW ADDITION, CITY OF SOUTHLAKE AS DEPICTED ON THE APPROVED SITE EXHIBIT ATTACHED HERETO AND INCORPORATED HEREIN AS EXHIBIT "A" AND PROVIDING AN EFFECTIVE DATE. WHEREAS, a Specific Use Permit for a Solar Energy System on residential property has been requested by a person or corporation having a proprietary interest in the property zoned as "R-PUD" Residential Planned Unit Development District; and, WHEREAS, in accordance with the requirements of Section 45.1 (45) and 45.17 of the City's Comprehensive Zoning Ordinance, the Planning and Zoning Commission and the City Council have given the requisite notices by publication and otherwise, and have afforded the persons interested and situated in the affected area and in the vicinity thereof; and, WHEREAS, the City Council does hereby find and determine that the granting of such Specific Use Permit is in the best interest of the public health, safety, morals and general welfare of the City. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SOUTHLAKE, TEXAS: SECTION 1. A Specific Use Permit is hereby granted for a Solar Energy System on residential property on 1909 Water Lily Drive being described as Lot 27, Block 7, Myers Meadow Addition, City of Southlake as depicted on the approved Site Exhibit attached hereto and incorporated herein as Exhibit "A" and providing an effective date, subject to the provisions contained in the comprehensive zoning ordinance and the restrictions set forth herein. Case No. Attachment F ZA20-0063 Page 1 SECTION 2. This resolution shall become effective on the date of approval by the City Council. PASSED AND APPROVED THIS DAY OF , 2021. CITY OF SOUTHLAKE By: Laura Hill, Mayor ATTEST: Amy Shelley City Secretary Case No. Attachment F ZA20-0063 Page 2 EXHIBIT `A" Plans and Support Information Reserved for exhibits Case No. Attachment F ZA20-0063 Page 3