Item 8 - Plans ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED BUILDING CONIC CONCRETE DC DIRECT CURRENT POWER—CONDITIONING INVERTER. EGC EQUIPMENT GROUNDING CONDUCTOR (E) 2. A NATIONALLY — RECOGNIZED TESTING EXISTING EMT ELECTRICAL METALLIC TUBING FSB LABORATORY SHALL LIST ALL EQUIPMENT IN FIRE SET—BACK GALV GALVANIZED GEC GROUNDING COMPLIANCE WITH ART. 110.3. ELECTRODE CONDUCTOR GND GROUND HDG HOT 3. WHERE ALL TERMINALS OF THE DISCONNECTING DIPPED GALVANIZED I CURRENT Imp CURRENT AT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, MAX POWER Isc SHORT CIRCUIT CURRENT kVA A SIGN WILL BE PROVIDED WARNING OF THE KILOVOLT AMPERE kW KILOWATT LBW LOAD HAZARDS PER ART. 690.17. BEARING WALL MIN MINIMUM (N) NEW NEUT 4. EACH UNGROUNDED CONDUCTOR OF THE NEUTRAL NTS NOT TO SCALE OC ON CENTER PL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PROPERTY LINE POI POINT OF INTERCONNECTION PHASE AND SYSTEM PER ART. 210.5. PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS 5. CIRCUITS OVER 250V TO GROUND SHALL COMPLY STEEL STC STANDARD TESTING CONDITIONS TYP WITH ART. 250.97, 250.92(B). TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V 6. DC CONDUCTORS EITHER DO NOT ENTER BUILDING VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE OR ARE RUN IN METALLIC RACEWAYS OR AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 7. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 8. MODULE FRAMES SHALL BE GROUNDED AT THE UL — LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. VICINITY MAP INDEX Sheet 1 COVER SHEET Sheet 2 PROPERTY PLAN Sheet 3 SITE PLAN Sheet 4 STRUCTURAL VIEWS LICENSE GENERAL NOTES ' Sheet 5 UPLIFT CALCULATIONS Sheet 6 THREE LINE DIAGRAM TYPE EC 33536 1. ALL WORK SHALL COMPLY WITH THE 2018 IBC , Sheet 7 THREE LINE DIAGRAM CONT. # AND 2018 IRC. 2. ALL ELECTRICAL WORK SHALL Sheet 8 PHOTOSHOP COMPLY WITH THE 2020 NATIONAL ELECTRIC CODE. Cutsheets Attached t MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Southlake City REV BY DATE COMMENTS REV A DOC 8/13/2020 OFFSET DECREASE,SETBACKS,CORRECTIONS UTILITY: Oncor (MP2 Energy—Dallas) CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borjo JimenezBENEFIT OF ANYONE T = 5 Ln SHALL IT BE DISCLOSEDCNP T TESLA INC.,NOR MOUNTING Z C WHOLE OR IN S C SYSTEM: 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENTS Comp V4 wFlashing—Insert ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: PERMISSION of TESLA INC. Delta Electronics # M8—TL—US [240V1 9728220934 COVER SHEET 1 d 12/17/2020 \ POOL 62-3' / i i i i 1 � i \ / i 52-5' � c / i i I � I // 39'-9. i I / V / PROPERTY PLAN N Scale:1" = 30'-0' W E 0 30' 60' S CONFIDENTIAL-THE INFORMATION HEREIN [INVERTER: NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borja JimenezBENEFIT OF 5 L n SHALL IT BEANYONE DISCLOSED INPWHOLEAOR IN NORUNTING SYSTEM: 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENT'S S Comp V4 wFlashing—Insert ORGANIZATION,EXCEPT IN CONNECTION WITH DULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE 37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF IESLA INC. elta Electronics # M8—TL—US [240V1 9728220934 PROPERTY PLAN 2 d 12/17/2020 PITCH:23 ARRAY PITCH:23 METER IS WITHIN 10 FEET FROM THE MP1 AZIMUTH:338 ARRAY AZIMUTH:338 AC DISCONNECT MATERIAL:Comp Shingle STORY: 2 Stories PITCH:24 ARRAY PITCH:24 THE VISIBLE LOCKABLE LABELED MP2 AZIMUTH:68 ARRAY AZIMUTH:68 ® \\ MATERIAL:Comp Shingle STORY: 2 Stories DISCONNECT IS LOCATED WITHIN 10 SV PITCH:24 ARRAY PITCH:24 FT. OF ONCOR METER MP3 AZIMUTH:68 ARRAY AZIMUTH:68 a MATERIAL:Comp Shingle STORY: 2 Stories V PITCH:24 ARRAY PITCH:24 MP4 AZIMUTH:68 ARRAY AZIMUTH:68 NO MODULES VISIBLE o � � � v MATERIAL:Comp Shingle STORY: 2 Stories PITCH:24 ARRAY PITCH:24 FROM THE STREET 4 MPS AZIMUTH:C 2 ARRAY AZIMUTH: �� �° MATERIAL:Comp Shingle STORY: 2 Stories \ N SV SV x LEGEND POOL . (E) UTILITY METER & WARNING LABEL 7 SV INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS RELAY ti9 ® tide AUTOMATIC RELAY Front Of House =��s � DC \\ DC DISCONNECT & WARNING LABELS PRODUCTION: 13965 kWh � ®�` AG EFFICIENCY: 1110.11 kWh \ AC DISCONNECT & WARNING LABELS \ DC JUNCTION/COMBINER BOX & LABELS OFFSET: 62% `;E�;`��SS'� B ENERGY STORAGE SYSTEM FOR STAND MP1 ARRAY SOFT: 236 ALONE OPERATION MP2 ARRAY SOFT: 196' o �k- DISTRIBUTION PANEL & LABELS MP3 ARRAY SOFT: 118' �����` `�y' Lc LOAD CENTER & WARNING LABELS MP4 ARRAY SOFT: 59' O DEDICATED PV SYSTEM METER MP8 ARRAY SQFT: 118' /� �e� — RSD RAPID SHUTDOWN � pG PID 0 STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR O P�� ——— CONDUIT RUN ON INTERIOR / GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L='J 9j (E)DRIVEWAY SITE PLAN IN TOTAL ARRAY A 8 Scale:1/16" = 1' w E / TOTAL ROOF AREA (SF): 5814 01, 16' 32' S TOTAL ARRAY AREA IS N 12.52 PERCENT OF TOTAL ROOF AREA CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borjo Jimenez 5 L n S BENEFIT ANYONE C EXCEPT HALLIT BEDISCLOSEDIN A NOR MOUNTING SYSTEM:WHOLE OR IN 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing—Insert ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: NAME: SHEET: REV: DATE: PERMISSION OF IESLA INC. Delta Electronics # M8—TL—US [240V1 1 9728220934 SITE PLAN 1 3 d 12/17/2020 S1 (N) PV MODULE (E) MOUNTING PLANE (MP) sv TYPICAL PV SIDE VIEW NTS PV MODULE 5/16"X1.5" BOLT WITH 5/16" FLAT WASHER INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT ---------Zoo --- -------- HOLE. ZEP MOUNTING BLOCK (4) ATTACH FLASHING INSERT TO OUNTINGND ATTACH ZEP FLASHING INSERT (3) C(2) MO RAFTERBLOCK USING LAG SCREW. (E) COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING E ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS ( ) SEALANT EVENLY OVER THE 5/16" DIA STAINLESS ROOF PENETRATION. STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP [(4) OF MOUNTING BLOCK & (E) RAFTER STANDOFF SECURELY FASTEN WITH BOLT. Scale: 1 1/2" = 1' CONFIDENTIAL-THE INFORMATION HEREIN [INVERTER: NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borja JimenezBENEFIT OF 5 L n SHALL IT BEANYONE DISCLOSED INPWHOLEAOR IN NOR UNTING SYSTEM: 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENT'S S Comp V4 wFlashing-Insert ORGANIZATION,EXCEPT IN CONNECTION WITH DULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE 37) Hanwho Q-CELLS # Q.Peak DUO BLK-G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF IESLA INC. elta Electronics # M8-TL-US [240V1 9728220934 STRUCTURAL VIEWS 4 d 12/17/2020 Jobsite Specific Design Criteria Design Code ASCE-7-16 Ground Elevation Ke 1 Factor Ultimate Wind Speed V—Ult 150 Fig.26.5-18 Exposure Category C Section 26.7 Ground Snow Load pg 5 Table 7.2-1 MP Specific Design Information MP Name MP1 MP2 MP3 MP4 MP8 Roofing Comp Shingle Comp Shingle Comp Shingle Comp Shingle Comp Shingle Standoff ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w ZS Comp V4 w Flashing—Insert Flashing—Insert Flashing—Insert Flashing—Insert Flashing—Insert Pitch 23 24 24 24 24 SL/RLL: PV 2.7 psf 2.7 psf 2.7 psf 2.7 psf 2.7 psf SL/RLL: Non—PV 19.0 psf 18.5 psf 18.5 psf 18.5 psf 18.5 psf Standoff Spacing and Layout MP Name MP1 MP2 MP3 MP4 MP8 Landscape X—Spacing 72" 72' 72" 72" 72" Landscape 24" 24' 24" 24" 24' X—Cantilever Landscape Y—Spacing 41' 41" 41" 41' 41" Landscape Y—Cantilever Portrait X—Spacing 24" 24" 24" 24" 24" Portrait X—Cantilever 14" 14" 14" 14" 14" Portrait Y—Spacing 69" 69' 69" 69" 69" Portrait Y—Cantilever — — — — — Layout Staggered Staggered Staggered Staggered Staggered X and Y are maximums that are always relative to the structure framing that supports the PV.X is across rafters and Y is along rafters. CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTON: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borja JimenezBENEFIT OF ANYONE EXCEPT TESLA 5 L n SHALL IT BEDISCLOSED INWHOLEOR IN NOR MOUNTING SYSTEM: 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing—Insert ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE (37) Hanwha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: NAME: SHEET: REV: DATE: PERMISSION OF TESLA INC. Delta Electronics # M8—TL—US [240V1 9728220934 UPLIFT CALCULATIONS 5 d 12/17/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: Inv 1: DC Ungrounded INV To)Delta Electronics#M8-TL-US[240V] -(18)Hanwha Q-CELLS#Q.Peak DUO BLK-G6+340 TYPE EC # 33536 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:116 893 925 Inverter, 7680w,240V/208V,97.57,Zigbee PV Module; 340W,318 PTC,40MM,Black Fr,MC4,ZEP,IDDOV Underground Service Entrance Voc: 40.66 Vpmax: 33.94 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 200A MAIN SERVICE PANEL Inverter 1 IND E; 20OA/2P MAIN CIRCUIT BREAKER Delta Electronics T AC DISCONNECT 7 AUTOMATIC RELAY AC DISCONNECT (N) 200A INTERNAL 3 M8-TL-US [240V] Da (E) WIRING ov Z Y X DC_ MP 3/8: 1x12 ----J A OOA 2P 11 A 20A 2P DC* ____________ EGC- Ll DC 2 DC+ I I N IN N Dc- 2 EGC. DC+ DC+ 32P Gec 11 N DC- Dc- MP 1: 1x6 } + I 4 L1 GND EGC ____________ __ EGC------------- ----J 5 0A1 Lz W ENERGY N STORAGE (1)Conduit Kit; 3/4"EMT EGCI SYSTEM I 30A 2P 4 I u 6 I z W ENERGY EGC N L2 LJ N STORAGE � I I -- EGC SYSTEM 30A 2P 4 ,I\ Ll TO 120/240V z LN W STORAGE ENERGY SINGLE PHASE TO 2nd L EGC SYSTEM UTILITY SERVICE GATEWAY 200A 2P ------ - 4�1 • • (E)LOADS THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED WITHIN 10 FT. OF ONCOR METER Utility Meter (E) 200A DISTRIBUTION PANEL \n, GD Please segge MCI wiring detail page for more information 10j, (1)G5rq B�Copper Y Y TESLA)AC9POWERWALL 2.0; Home Energy Storage,13.5KWH,Stackable,5.8kVA AC PV (6)DMCI RapldlSh�tdoiwn,600V,12A,NEMA 4X,MC4,Zep Bracket (1)Eaton#DH224NRK Heavy Duty Disconnect,200A,24OVac,Fusible,NEMA 3R,2P,3W,for Class J fuses -(2)Bussmann#LPJ-200SP Class J fuse,200A,60OVoc,must be installed in Heavy Duty disconnect Y (1)Tesla#12321 00-00-E Back-up Gateway 2.0 NA for AC PW 2.0 (1)AWG#10,7HWN-2,Black -(1)Eaton# CSR220ON (A)EL o (0 AWG#10,THWTI-2,Red 200A B ONLY; 2-Pole,120V/24OV,25kAIC,Bolt On (1)AWG#10,THWN-2,White -(1)CUTLLR-HAMM #BR230 Breaker; 30A 2P,2 Spaces __ __-(1)AWG#10,THWTI-2,Green -(l)Conduit Kit; 1"EMT _ -(1)CUTLER-HAMMER#BR220 (1)AWG#2,THWN 2,Black Breaker; 20A 2P,2 Spaces O (I)AWG#2,THWN 2,Red -(1)CUTLER-HAMM #BQC 30230 (1)AWG 2 THWN-2,White Breaker; 30A 2P-30A�2P,2 Spaces,Quadplex #. -(l)AWG#6,1HWN-2,Green -(1)Ponelboard Accessor20 It for GW 2.0 NA 200A,6sp 12cir,1 240V,1PH ll�T(3)AWG#2/0,THWN-2,Black X (1)CUTLER-HAMMER#DS16FK ©ISN(I)AWG#6,THWN-2,Green Class R Fuse Kit k (1)Co�lduit (2)AWG#10,PV wire,60OV,Black Voc* =532,71 VDC Isc=10,52 ADC -(2)FERRAZ SHAWMUT#TR11 OR 2 PVC; Schedule 80 00 Fuse; 110A,25OV,Class IRKS . . ................. 1 (1)AWG#10,THHN/THWN-2,Green EGC Vmp =407.28VDC Imp=10.02 ADC -0)cUTLER-HAMMER#DG20ONK �(3)AWG#2/0,THNN-2,Black �(1)AWG#8,THWN-2,Black " (1)Conduit Kit; 3/4"EMT _ Ground/Neutral It; 200A General,Heavy Duty(DG,DH),NEMA 1,3R O IsF(1)AWG#6,THWTI-2,Green O IsF(1)AWG#8,THWN-2,Red (2)AWG#10,PV Wire,600V,Black Voc* =266.36VDC Isc=10.52 ADC -(1)CUTLER-HAMMER Y DG224NRK IIk�[(1)Conduit 11L.==LLL(1)AWG#10,THWN-2,White NEUTRAL VmP =240 VAC Imp=32 AAC (1)AWG#10,THHN/THWN-2,Green EGC Vmp =203.64VDC Imp=10.02 ADC Disconnect; 200 240Vac,Fusible,NEMA 3R 2 PVC; Schedule 80 rAm (1)ff(I)Canduit Kit: 3/4"EMT CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borjo Jimenez 5 L n S BENEFIT ANYONE EXCEPT HALLIT BEDISCCLOSEDIN A NOR MOUNTING SYSTEM: -1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing-Insert ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE (37) Hanwho Q-CELLS # Q.Peak DUO BLK-G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: NAME SHEET: REV: DATE: PERMISSION OF IESLA INC. Delta Electronics # M8-TL-US [240V1 1 9728220934 THREE LINE DIAGRAM 6 d 12/17/2020 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) AWG #6 TO (N) GROUND ROD Panel Number: Inv 2: DC Ungrounded INV 2 (1)Delta Electronics#M8-TL-US[240V] PV Module;HanwhoQ-C318SP#C,40MMDUOcBLFr, 340 laoav TYPE EC # 33536 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:116 893 925 Inverter; 768OW,24OV/208V,97,57,Zigbee Underground Service Entrance Voc: 40.66 Vpmax: 33.94 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER TO MAIN SERVICE Inverter 2 IND Delta Electronics 11 8 AC DISCONNECT AUTOMATIC RELAY AC DISCONNECT (N) 200A INTERNAL M8-TL-US [240V] �A 16 12 32.0018 Da V U T Dc- I MP 2: 1x7 200A OOA 2P 110A 20Af2P DC+ __________-_____________ EGc_ uDc ------------- 9 ----------------i L2 DC, I DC+ N N N Dc- 10 Dc- __� __ _ GND MP 1: lx6 --_--___________ EGG DC+ DC+ G -- -- - G - - - 30A 2P - GE c ---T N Dc- Dc- MP 2/4: lx6 _______________________-___________-____________________J I 13 L1 GND __ EGC_ EGC 14 I L2 S ENERGY I N STORAGE I I EGC SYSTEM (1)Conduit Kit; 3/4'EMT 3OAl2P I 15 I 13 Li EGC! N Lz u i LN S ENERGY STORAGE I EGC SYSTEM z i 30A 2P 13 L I L2 S I ENERGY N STORAGE 200A 2P .________kj EGc SYSTEM LF �• THE VISIBLE LOCKABLE LABELED DISCONNECT IS LOCATED (E)LOADS WITHIN 10 FT. OF ONCOR METER (E) 200A DISTRIBUTION PANEL GD Please see MCI wiring detail page for more information TO I (1)G5r8B'dxRB�Co er (3)1092170-05-J /� A (1)MULTI-CONTACT PV-AZB4 pp TE LA AC POWERWALL 2.0; Home Energy Storoge,13.5KWH,Stackable,5.8kVA/-� 32.0018; Branch Socket; MC4 U-Joint Connector,Female 1 Eaton DH224NRK -(1)MULTI-CONTACT PV-AZS4 # envy Duty Disconnect,200A,240Vac,Fusible,NEMA 3R,2P,3W,for Class J fuses 32.0019; Branch Plug; MC4 U-Joint Connector,Male -(2)Bussmann#LPJ-200SP y U Class J fuse,200A,60OVac,must be installed in Heavy Duty disconnect PV (6)Delto R GP100010110(1)Testa#1232100-00-E MCI apid Shutdown,60OV,12A,NEMA 4X,MC4,Zep Bracket Back-up Gateway 2.0 NA for AC PW 2.0 (1)AWG#10,THWN-2,Black -(1)Eaton# CSR220ON © - (1)AWG#10,THWN-2,Red 200A"MB ONLY; 2-Pole,120V/24OV,25kAIC,Bolt On (1)AWG#10,THWN-2,White -(1)CUTLER-HAMMER#BR230 1 AWG 10 THWN-2,Green - 1 Conduit Kit; 1"EMT Breaker; 30A 2P,2 Spaces -(.) ...#.• ............(.). .. -(1)CUTLER-HAMMER#BR220 (1)AWG#2,THWN-2,Black (2)AWG#10,PV Wire,600V,Black Voc* =310.75VDC Isc=10.52 ADC Breaker; 20A 2P,2 Spaces (1)AWG#2,THWN-2,Red ® (1)AWG#10,THHN/THWN-2,Green EGC Vmp =237.58VDC Imp=10.02 ADC -(1)CUTLER-HAMMER#BQC730230 x (1)AWG#2,THWN-2,White -(1)AWG#6,THWN-2,Green _ _ _ (1)Conduit Kit; 3/4"EMT _ Breaker; 30A 2P-30A 2P,2 Spaces,Quadplex - - -------- ----- - ---- -(1)Ponelboord Accessoryy d for GW 2.0 NA ........ .. ................................... (4)AWG#10,PV Wire,60OV,Black Voc* =26636VDC Isc 10.52 ADC 200A,6sp/12cir,1210 240V,1PH OEM #2/0,THWN-2,Black O Ic-sF(1)AWG#10,THHN/THWN-2,Green EGC Vmp =203.64VDC Imp 10.02 ADC T (1)CUTLER-HAMMER#DS16FK �(1)AWG#6,THWN-2,Green _.._ (1.)Conduit.Kit; 3/4 EMT Class R Fuse Kit "' (1)Cooduit (2)AWG#10,PV Wire,60OV,Black Voc* =266.36VDC Isc=21.04 ADC -(2)FERRAZ SHAWMUT#TR110R 2 PVC; Schedule 80 ® (1)AWG#10,Solid Bare Copper EGC Vmp =203.64VDC Imp-20.04 ADC Fuse; 110A,250V,Class RK5 -(1)CUTLER-tIAMMER N DG200NK (3)AWG#2/0,THWN-2,Black �(I AWG#8,THWN-2,Black N (1.)Conduit.Kit; 3/4"EMT Ground eutral K'it; 200A General,Heavy Duty(OG,DH),NEMA 1, 3R (1)AWG#6,THWN-2,Green ®lot-(1)AWG#8,THWN-2,Redl(g (2)AWG#10,PV Wire,60OV,Black Voc* =310.75 VDC Isc=10.52 ADC -(1)CUTLER-HAMMER I DG224NRK III::: (I)Cooduit (1)AWG#10,THWN-2,White NEUTRAL Vmp =240 VAC Imp=32 AAC �(1)AWG#10,Solid Bare Copper EGC Vmp =237.58VDC Imp=10.02 ADC Disconnect; 200,240Vac,Fusible,NEMA 3R 2 PVC; Schedule 80AWGTHWN- r-n .=LL CONFIDENTIAL-THE INFORMATION HEREIN JOB NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borjo Jimenez 5 L n S BENEFIT ANYONE C SHALL BEDISCL� EXCEPT OSEDIN TESLA NOR MOUNTING SYSTEM: -WHOLE OR IN TI 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S ZS Comp V4 wFlashing-Insert ORGANIZATION,EXCEPT IN CONNECTION WITH MODULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE (37) Hanwho Q-CELLS # Q.Peak DUO BLK-G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE: PERMISSION OF TESLA INC. Delta Electronics # M8-TL-US [240V1 9728220934 THREE LINE DIAGRAM CONT. 7 d 12/17/2020 / J } dk `* a rti r ,1 10 'Awl 12 - r AwwT ✓k ', i �r �y 1 a CONFIDENTIAL-THE INFORMATION HEREIN FINVERTER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borjo Jimenez = 5 L n BENEFIT OF ANYONE EXCEPT TESLA INC.,NOR M: SHALL IT BE DISCLOSED IN WHOLE OR IN v4 wFlashing—Insert 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: Southlake TX 76092 ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE wha Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME:* SHEET: REV: DATE: PERMISSION OF TESLA INC. ctronics # M8—TL—US [240V1 9728220934 PHOTOSHOP 8 d 12/17/2020 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 1500 Bent Creek Dr �-v ENERGY l`^, UTILITY STORAGE �` SERVICE SYSTEMx3 �- P00 ENERGY STORAGE AC SYSTEM0 DISCONNECTx2 INVERTER AND AC DC DISCONNECT DISCONNECTx2 INVERTER AND ---------------------__ DC DISCONNECT SOLAR PHOTOVOLTAIC ARRA (S) PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB-7604273-00 CONFIDENTIAL-THE INFORMATION HEREIN [INVERTER: NUMBER: J B-7604273 00 CUSTOMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE Barry Smith 12.58 KW PV ARRAY David Borja JimenezBENEFIT OF 5 L n SHALL IT BEANYONE DISCLOSED INPWHOLEAOR IN NOR UNTING SYSTEM: 1500 Bent Creek Dr 81 KWH ENERGY STORAGE SYSTEM — PART TO OTHERS OUTSIDE THE RECIPIENT'S S Comp V4 wFlashing—Insert ORGANIZATION,EXCEPT IN CONNECTION WITH DULES: Southlake, TX 76092 THE SALE AND USE OF THE RESPECTIVE 37) Hanwho Q—CELLS # Q.Peak DUO BLK—G6+ 340 TESLA EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: PERMISSION OF IESLA INC. elta Electronics # M8—TL—US [240V1 9728220934 SITE PLAN PLACARD 9 d 12/17/2020 WARNING:PHOTOVOLTAIC POWER SOURCE WARNING ( •I) ' Label Label Location: Location: WARNING Label Location: Code:Per Per ••-: NEC ELECTRIC SHOCK HAZARD ELECTRIC SHOCK HAZARD 690.31.G.3 DO NOT TOUCH TERMINALS '•0 THE DC CONDUCTORS OF THIS Label • _ • TERMINALS ON BOTH LINE AND PHOTOVOLTAIC SYSTEM ARE PHOTOVOLTAIC DC Per Code: LOAD SIDES MAY BE ENERGIZED UNGROUNDED AND IN THE OPEN POSITION MAY BE ENERGIZED NEC DISCONNECT .•0 Location:Label Label Location: WARNING MAXIMUM POWER _A ■ Per INVERTER OUTPUT Code: POINT CURRENT(Imp) Per MAXIMUM POWER- Code: CONNECTION 0 ' POINT VOLTAGE(Vmp)_V NEC690.53 DO NOT RELOCATE MAXIMUM SYSTEM THIS OVERCURRENT VOLTAGE(Voc)_v DEVICE SHORT-CIRCUIT A CURRENT(Isc) Label • _ • CAUTION (D)(POI)Label Location: PHOTOVOLTAIC SYSTEM Code: WARNING CIRCUIT IS BACKFEDNEC 690.64.B.4 Per ..- 690.41.13 ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZEDLabel Location: CAUTION '• DUAL POWER givivLe"I Per Code: SECONDSOURCEIS NEC 705.12.B.3 PHOTOVOLTAIC SYSTEM Label • • WARNING Code:Per CEC 690.13.B Label Location: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF LOAD SIDES MAY BE ENERGIZED INTERCONNECTION IN THE OPEN POSITION Per ••- CEC DC VOLTAGE IS WARNING:ELECTRIC SHOCK •• 0.13.13 ALWAYS PRESENT WHEN HAZARD.DO NOT TOUCH SOLAR MODULES ARE TERMINALS.TERMINALS ON EXPOSED TO SUNLIGHT BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION.FOR SOTHRV EICE DE-ENERGIZE B SOURCE AND MAIN BREAKER. PV POWER SOURCE Label • _ • MAXIMUM AC P H OTOVO LTA I C AC OPERATING CURRENT A ■ sconnect MAXIMUM AC DISCONNECTPer Code: OPERATING VOLTAGE _V (C):Conduit NEC .0 :. ■ Distribution ■ DC Disconnect (IC): Interior Run Conduit Label AC A Load Center OPERATING CURRENT Per (M): Utility Meter MAXIMUM AC V 690.54 _ _ OPERATING VOLTAGE • of • • Label Location: Label Location: BACKUP LOAD CENTER CAUTION Per Code: TRI POWER SOURCE ••- NEC 408.4 SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD SOURCE IS ENERGY STORAGE SYSTEM Label • _ • CAUTION DO NOT ADD NEW LOADSPer Code: b • • NEC ' WARNING Per ..- THIS EQUIPMENT FED BY•- • • NEC � MULTIPLE SOURCES.TOTAL CAUTION �DEVCOES EXCOLUDINGUMANNT THIS PANEL HAS SPLICED FEED- Per Code: SUPPLY OVERCURRENT DEVICE, THROUGH CONDUCTORS. SHALL NOT EXCEEDAMPACITY OF BUSBAR. LOCATION OF DISCONNECT AT ENERGY STORAGE BACKUP LOAD PANEL NOMINAL ESS VOLTAGE_ 12(Y240V Label Location: Label Location: (MP) CAUTION Per Code: DUAL POWER SOURCEPer Code: CIRCUIT FROM ESS: 32A Per . 7(D)label t• •- marked in field SECOND SOURCE IS ARC FAULT CLEARING ENERGY STORAGE SYSTEM TIME FROM ESS: 67fI1S DATE OF CALCULATION: Location:Label ENERGY STORAGE SYSTEM ON SITE LOCATED WITHIN LINE OF SIGHTPerCode: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON ADJACENT WALL Per Code: Label • • ENERGY STORAGE SYSTEM ON SITE LOCATED ON OPPOSITE WALLPer Code: Label • _ • ENERGY STORAGE SYSTEM ON SITE LOCATED INSIDEPer Code: Disconnect Backup Load Center POWERWALL TYPICAL SYSTEM LAYOUTS Tesla Powerwall is a fully-integrated AC battery system for — 9 L WHOLE HOME BACKUP residential or light commercial use.Its rechargeable lithium-ion T battery pack provides energy storage for solar self-consumption, optlonal'! time-based control,and backup. Powerwall's electrical interface provides a simple connection to Solar any home or building.Its revolutionary compact design achieves market-leading energy density and is easy to install,enabling owners to quickly realize the benefits of reliable,clean power. Solar inverter ------------------------ Main panel Backup Gateway Utility meter Grid including service disconnect PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS T-= AC Voltage(Nominal) 120/240 V Dimensions' 1150 mm x 753 mm x 147 mm (45.3 inin)l nx5.75 i / Feed-In Type Split Phase Weight' 114 kg(251.3251.3 Ibs) Grid Frequency 60 Hz Mounting options Floor or wall mount Total Energy' 14 kWh Powerwall Whole home 'Dimensions and weight differ slightly if manufactured before March 2019. backup Usable Energy' 13.5 kWh Contact Tesla for additional information. Real Power,max continuous' 5 kW(charge and discharge) 753 mm 147 mm (29.6 in) (5.75 in) Real Power,peak(10s,off-grid/backup)' 7 kW(charge and discharge) Apparent Power,max continuous 5.8 kVA(charge and discharge) Apparent Power,peak(10s,off-grid/backup)7.2 kVA(charge and discharge) T = 5 L A PARTIAL HOME BACKUP Maximum Supply Fault Current 10 kA Maximum Output Fault Current 32 A Optional 115mm Overcurrent Protection Device 30 A . Imbalance for Split-Phase Loads 100% Power Factor Output Range +/-1.0 adjustable Solar Power Factor Range(full-rated power) +/-0.85 Internal Battery DC Voltage 50 V Round Trip Efficiency'.' 90% o o e Warranty 10years ENVIRONMENTAL SPECIFICATIONS 'Values provided for 25°C(770F),3.3 kW charge/discharge power. Solar Inverter 'In Backup mode,grid charge power is limited to 3.3 kw. Operating Temperature -200C to 500C(-40F to 1220F) -------------_-_------ Sub panel Backup Gateway Main panel Utility meter Grid 3AC to battery to AC,at beginning of life. Recommended Temperature 0°C to 300C(320F to 860F) COMPLIANCE INFORMATION Operating Humidity(RH) Up to 100%,condensing Storage Conditions -20°C to 30°C(-4°F to 86°F) Certifications UL 1642,UL 1741,UL 1973, Up to 95%RH,non-condensing UL 9540,IEEE 1547,UN 38.3 State of Energy(SoE):25%initial ^n Grid Connection Worldwide Compatibility Maximum Elevation 3000 m(9843 ft) Emissions FCC Part 15 Class B,ICES 003 Environment Indoor and outdoor rated Powerwall Backup loads Home loads Environmental RoHS Directive 2011/65/EU Enclosure Type NEMA 3R Seismic AC156,IEEE 693-2005(high) Ingress Rating IP67(Battery&Power Electronics) P56(Wiring Compartment) Wet Location Rating Yes Noise Level @ 1m <40 dBA at 30°C(86°F) T - S L M TESLA.COM/ENERGY NA-BACKUP-2019-06-11 TESLA.COM/ENERGY ANELTA Solar Inverter for North America AN E LTA Solar Inverter for North America Single Phase Solar Inverter for North America Model M4-TL-US MS-TL-US M6-TL-US I MS-TL-US M10-TL-US M10-4-TL-US M4-TL-US I M5-TL-US I M6-TL-US I M8-TL-US I M10-TL-US I M10-4-TL-US Max.system voltage soot/ Nominal voltage 380 V Max.operating voltage 540 V Operating MPPT voltage 50 V to 480 V range Max.input current per MPPT 12 A 12 A 12 A 12 A 20 A 10 A Max.short circuit current per 15 A 15 A 15 A 15 A 30 A 15 A MPPT Max.DC/AC ratio 1.3 DC disconnect Integrated MPPtracker 2 2 3 3 2 4 Input strings available 2-2 2-2 2-2-2 2-2-2 2-2 2-2-2-2 OUTPUT(AC) Nominal output power 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max.output power 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W 240Vac Nominal output power 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W 208Vac Max.output power 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W 208Vac AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max.continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating 60 Hz frequency Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption <1.5 W 1) THD @ nominal power <3% Power factor @ nominal 0.99 power Adjustable power factor 0.85i to 0.85c range GENERAL SPECIFICATI Key Features. Max.efficiency 98% CEC efficiency 97.0%@ 208 V 97.5%@ 240 V 97.5%@ 240 V 97.5%@ 240 V 97.5%@ 240 V 97.5%@ 240 V • Smart inverter with BILE, optional WiFi, Ethernet, 3G/4G cellular 97.5%@24ov 97.5%@24ov 97.5%@240V 97.5%@24ov 97.5%@240V 97.5%@24ov communication Operating temperature -22°F to 149°F(-30°C to 65°C) • Optional revenue grade meter(compliant with ANSI C12.20, Class 0.5) range with derating above 113 OF(45°C) Storage temperature range -40°F to 185°F(-40°C to 85°C) • Support bi-directional cloud communication Humidity 0%to95% • Support remote diagnosis and OTA Max.operating altitude 9,843 ft(3,000 m) • Type 4 protection Acoustic noise <45 dB(A)@ 3 ft(1m) • Built-in AFCI &Rapid shutdown controller • CEC efficiency 97.5% • UL 1741 SA, HECO compliant • CA Rule 21 Phase 1 &2&3 compliant Rev 14-02/2020 ©Copyright 2020 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. AN E Ual Solar Inverter for North America Model M4-TL-US I M5-TL-US I M6-TL-US I M8-TL-US I M10-TL-US I M10-4-TL-US MECHANICAL DESIGN Dimensions(W x H x D) 16.7 x 23.2 x 5.9 in(425 x 590 x 150 mm) Display LED indicators Weight 2) 41.9 Ibs(19.0 kg) 41.91bs(19.0 kg) I 44.311,s(20.1 kg) 45.21bs(20.5 kg) I 47.61bs(21.6 kg) I 47.61bs(21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Rapid Shutdown Initiation Loss of AC or DC Disconnect Method Communication interface BLE,optional WiFi,Ethernet,3G/4G cellular communication Enclosure material Die-casting aluminum STANDARDS Enclosure protection rating Type 4 Safety UL 1741,CSA-C22.2 No.107.1-01 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547,IEEE 1547.1 EMC FCC part 15 Class B AFCI UL 1699B(Type 1),NEC 2017 Article 690.11 Rapid shutdown protection NEC 2017 690.12 1) Integrated meter ANSI C12.20,Class 0.5 Grid support regulation UL 1741 SA,California Rule 21 phase 1 8 2 8 3,HECO Compliant WARRANTY EL Standard warranty 10 years 1) Without consumption of communication card 2) Without weight of revenue grade meter 3) Compliant with Tigo rapid shutdown system or APS rapid shutdown system @0 C US Delta Electronics(Americas), Ltd. 46101 Fremont Blvd,Fremont,CA 94538 Sales Email:Inverter.Sales@deltaww.com Support Email:Inverter.Support@deltaww.com Sales Hotline:+1-877-440-5851 or+1-626-369-8021 Support Hotline:+1-877-442-4832 Support(Intl.):+ 69-8019 AELT�I Monday to Fridayy from from Gam to 6pm PST(apart from Holidays) www.Delta-Americas.com Rev 14-02/2020 ©Copyright 2020 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. A&ELTA Residential Energy Storage Solution for North America Accessory: MCI (Middle Circuit Interrupter) Features: aM • Automatic function test upon startup,ensure safety • Enclosure protection Type 4 • Meet 2017 NEC Article 690.12 Rapid Shutdown • No installation needed for every PV Module,make better cost performance for PV system • With PLC,no additional cable needed Delta part number GPI00010110 GPI00010114 Maximum system voltage 600 Vdc Rated input operating voltage 6 Vdc to 80 Vdc Number of input circuit 1 Startup voltage 22 V Rated input current 12 A OUTPUT RATINGS Rated output current 12 A Control signal method PLC signal ENE Dimensions(W x H x D) 4.6 x 6.5 x 3.0 in(117 x 165 x 76.5 mm) 3.8 x 6.5 x 1.1 in(97.3 x 165 x 27.3 mm) (without cable) (without cable) Weight 2.0 Ibs(0.9 kg) 1.4 Ibs(0.64 kg) Bracket Groove adapter bracket Without Cooling Natural convection DC input/output connectors MC4 PV connector Cable length with connector Input:5.9 in(150 mm) Input:5.9 in(150 mm) Output:47.2 in(1200 mm) Output:12 in(305 mm) Enclosure material Plastic Operating temperature -40°F to 185°F(-40°C to 85°C) Storage temperature -40°F to 185°F(-40°C to 85°C) Humidity 0%to 95% Maximum operating altitude 9,843 fit(3,000 m)above sea level Self power consumption <3.0 W Warranty 10 years STANDARD COMPLIANCE Enclosure protection rating Type 4/IP67 Safety LIL 1741,CSA C22.2 No.330-17 Rapid shutdown NEC 2017 Article 690.12 EMC FCC Part 15 Class B Rev 05—09/2019 ©Copyright 2018 Delta Electronics(Americas),Ltd.All rights reserved. Specifications subject to change without prior notice. POWERWALL Backup Gateway 2 The Backup Gateway 2 for Tesla Powerwall provides energy management T=_ 5 i, and monitoring for solar self-consumption,time-based control,and backup. The Backup Gateway 2 controls connection to the grid,automatically detecting outages and providing a seamless transition to backup power. When equipped with a main circuit breaker,the Backup Gateway 2 can be installed at the service entrance.When the optional internal panelboard is installed,the Backup Gateway 2 can also function as a load center. The Backup Gateway 2 communicates directly with Powerwall,allowing you to monitor energy use and manage backup energy reserves from any mobile device with the Tesla app. PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS AC Voltage(Nominal) 120/240V Dimensions 660 mm x 411 mm x 149 mm Feed-In Type Split Phase (26 in x 16 in x 6 in) Weight 20.4 kg(45 Ib) Grid Frequency 60 Hz Mounting options Wall mount,Semi-flush mount Current Rating 200 A Maximum Input Short Circuit Current 10 kA1 Overcurrent Protection Device 100-200A;Service Entrance Rated' Overvoltage Category Category IV AC Meter Revenue accurate(+/-0.2%) Primary Connectivity Ethernet,Wi-Fi T s 9 L F5 Secondary Connectivity Cellular(3G,LTE/4G)� User Interface Tesla App Operating Modes Support for solar self-consumption, 660 time-based control,backup,and off-grid Backup Transition Automatic disconnect for seamless backup Modularity Supports up to 10 AC-coupled Powerwalls Optional Internal Panelboard 200A 6-space/12 circuit Eaton BR Circuit Breakers Warranty 10 years 1 When protected by Class J fuses,Backup Gateway 2 is suitable for use in 411 149 circuits capable of delivering not more than 22kA symmetrical amperes. 2 The customer is expected to provide internet connectivity for Backup Gateway 2;cellular should not be used as the primary mode of connectivity.Cellular connectivity subject to network operator service coverage and signal strength. COMPLIANCE INFORMATION ENVIRONMENTAL SPECIFICATIONS Certifications UL 67,UL 869A,UL 916,UL 1741 PCS Operating Temperature -200C to 500C(-40F to 122°F) CSA 22.2 0.19,CSA 22.2 205 Operating Humidity(RH) Up to 100%,condensing Emissions FCC Part 15,ICES 003 Maximum Elevation 3000 m(9843 ft) Environment Indoor and outdoor rated Enclosure Type NEMA 3R T = 5 L Fi NA 2020-05-23 TESLA.coM/ENERGY powered by MECHANICAL SPECIFICATION DUO Format 68.5 x 40.6 x 1.57in(including frame) (1740 x 1030 x 40 mm) _ cos-I„wmml Weight 47.4lbs(21.5kg) n.<les°mm: uc l.�smml Front Cover 0.13 in(3.2 mm)thermally pre-stressed glass with anti-reflection technology Back Cover Composite film aseroe.,,,,n Frame Black anodized aluminum ® °Sst>u�mml Cell 6 x 20 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 x 1.26-2.36 x 0.59-0.71in(53-101 x 32-60 x 15-18mm), � Protection class IP67,with bypass diodes Cable 4mm2Solar cable;(+)>43.3in(1100mm),(-)>_43.3in(1100mm) .a.nrevoramsTulat _ Connector Shush MC4;IP68 + -��-ssrlw mml °Eru" �mml . • = • ELECTRICAL CHARACTERISTICS POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS,STC'(POWER TOLERANCE+5W/-0 W) Power at MPP1 Pmm [W] 330 335 340 345 . QCELLS E Short Circuit Current' I� [A] 10.41 10.47 10.52 10.58 pMPgT E Open Circuit Voltage' V., IV] 40.15 40.41 40.66 40.92 QG 7e! 1 c Current at MPP 1.11 [A) 9.91 9.97 10.02 10.07 .<v / Fy ror exam Voltage at MPP v- IV] 33.29 33.62 33.94 34.25 .. o nroduc eace PertOR° Efficiency' g [%] >_18.4 >_18.7 >_19.0 >_19.3 w°rimy C j`�v B�9 QCELLS MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NMOT' OMPP Power at MPP Pmm [W] 24ZO 250.7 254.5 258.2 E Short Circuit Current Io, [A] 8.39 8.43 8.48 8.52 £ Open Circuit Voltage V_ IV] 3786 38A0 38.34 38.59 Q.ANTUM TECHNOLOGY:LOW LEVELIZED COST OF ELECTRICITY Current at MPP IM„ [A) 7.80 784 7.89 7.93 (o J Higher yield per surface area,lower BOS costs,higher Voltage at MPP V.11 IV] 31.66 31.97 32.27 32.57 J� power classes,and an efficiency rate Of up to 19.5%. Weasummenttolerances P-t35s;Is,;Von t5%at STC:1000 W/m�25t2'C,AM 1.5 according to IEC 60904-3•'800 W/m%,NMOT spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE INNOVATIVE ALL-WEATHER TECHNOLOGY fig'°° -ate Atleast98%of nominal power during � --r-----r ------ �-'t�; Optimal yields,whatever the weather with w w -.�,....•e�------ first r.Thereafter max.0.54% ° __________________ Yea excellent low-light and temperature behavior. 53 M -------- 6 WQ degradation per year.At least g.w of nominal power up to 10 years.At -` leas of nominal power up to >z w t 85% w ENDURING HIGH PERFORMANCE wo 25years. F �° --��-----I---------- ----- Long-term yield security with Anti LID and Anti PID Technology', ¢o All data within measurement tolerant- w as.Full warranties in accomance with Hot-Spot Protect and Traceable Quality Tra.Q M. the warranty terms of the o CELLS Iax.olAZE IW1.4 0 n sales organization of your respective ZEP COMPATIBLET"FRAME DESIGN m country. 7a � �w i•��w.i vEaas Typical module performance under low irradiance conditions in High-tech black Zep Compatible'"frame,for improved aesthetics, comparison to STC conditions(25'C,1000 W/m2) easy installation and increased safety. TEMPERATURE COEFFICIENTS F� Temperature Coefficient of ls° a [%/K] +0.04 Temperature Coefficient of Va (i [%/K] -0.27 A RELIABLE INVESTMENT Temperature Coefficient of Pm,, y [%/K] -0.36 Normal Module Operating Temperature NMOT [°F] 10935.4(43t3°C) m Inclusive 25-year product warranty and 25-year o linear performance warranty2. PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vss IV] 1000(IEC)/1000(UL) Protection Class II a STATE OF THE ART MODULE TECHNOLOGY Maximum Series Fuse Rating [A DC] 20 Fire Rating based on ANSI/UL 1703 C(IEC)/TYPE 2(UL) / Q.ANTUM DUO combines cutting edge cell separation Max.Design Load,Push/Pull(UL)' [Ibs/ftj 50(2400Pa)/50(2400Pa) Permitted Module Temperature -40•F up to+185"F a and innovative wiring with Q.ANTUM Technology. Max.Test Load,Push/Pull(UL)' [Ibs/ftq 75(3600Pa)/75(3600Pa) on--inuouaDuty (-40"Cupto+850C) e 'See Installation Manual -APT test conditions according to IEC/TS 62804-1:2015,method B(-1500 V,168 h) 'See data sheet on rear for further information QUALIFICATIONS AND CERTIFICATES UL 1703,CE-compliant,IEC 61215:2016,IEC 61730:2016, Application Class 11,U.S.Patent No.9,893,215(solar cells) _ sAo C E c v.„® u THE IDEAL SOLUTION FOR: V D E Rooftop arrays on commercial and industrial buildings Note:Installation instructions must be followed.See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. CELLS 4Han00 Spectrum tr CELLS Center Drive, Inc. Engineered in Germany 400 Spectrum Center Drive,Suite 1400,Irvine,CA 92618,USA ITEL+1 949 748 59 96 1EMAIL inquiry@us.q-cells.coml WEB www.q-cells.us T = 5Ln 1 GENERAL NOTES • DRAWING OF STANDARD MCI WIRING DETAIL FOR ANY GIVEN STRING LENGTH • IF INITIATED, RAPID SHUTDOWN OCCURS WITHIN 30 GD SECONDS OF ACTIVATION AND LIMITS VOLTAGE ON THE ROOF TO NO GREATER THAN 165V (69O.12.B.2.1) • MID CIRCUIT INTERRUPTER (MCI) IS A UL 1741 PVRSE CERTIFIED RAPID SHUTDOWN DEVICE (RSD) DC+ J—BOX J—BOX J—BOX J—BOX J—BOX J—BOX MCI MCI RETROFIT PV MODULES DC- • MCIS ARE LOCATED AT ROOF LEVEL, JUST UNDER THE PV MODULES IN ACCORDANCE WITH 690.12 REQUIREMENTS 1 • THE QUANTITY OF MCIS PER STRING IS DETERMINED BY STRING LENGTH - MCI INPUT = 1 MODULE - NUMBER OF MODULES BETWEEN MCI UNITS = 0-3 J—BOX J—BOX J—BOX J—BOX - MAXIMUM NUMBER OF MODULES PER MCI UNIT = 4 - MINIMUM NUMBER MCI UNITS = MODULE COUNT/4 PLEASE REFER TO MCI CUTSHEET AND PVRSA INSERT FOR O (2)AWG, PV Wire, 600V, Black DC MORE INFORMATION ''^50l8fClty ®pSolar Next-Level PV Mounting Technology Zel l Next-Level PV Mounting Technology ZS Comp Components for composition shingle roofs 6 Mounting Block Array Skirt Interlock Pal No.850-1633 Part No.850-1608 or 500-0113 Part No.850-1388 or 850-1613 Listed to UL 2703 Listed to UL 2703 Listed to UL 2703 Flashing Insert Grip Ground Zep V2 Part No.850-1628 Part No.850-1606 or 850-1421 Part No.850-1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 10 OOMPATj Description PV mounting solution for composition shingle roofs " Works with all Zep Compatible Modules °pMPnt° Auto bonding UL-listed hardware creates structural and electrical bond ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Captured Washer Lag End Cap DC Wire Clip U� LISTED Part No.850-1631-001 Part No. Part No.850-1509 Specifications 850-1631-002 (L)850-1586 or 850-1460 Listed to UL 1565 850-1631-003 (R)850-1588 or 850-1467 • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 Wind tunnel report to ASCE 7-05 and 7-10 standards ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices fp� Leveling Foot Part No.850-1397 zepsolar.com zepsolar.com Listed toUL2703 This document does not create any express warranty by Zep Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for This document does not create any express warranty by Zap Solar or about its products or services.Zep Solar's sole warranty is contained in the written product warranty for each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely each product.The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty.The customer is solely responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. responsible for verifying the suitability of ZepSolar's products for each use.Specifications are subject to change without notice.Patents and Apps:zspats.com. Document#800-1839-001 Rev D Date last exported:April 29,2016 11:22 AM Document#800-1839-001 Rev D Dale last exported:April 29,2016 11:22 AM ROOFING SYSTEM SPECIFICATIONS GROUND ZEPV2 LEVELING FOOT Listed to UL 2703 and UL 467 Listed to UL 2703 DESCRIPTION PV mounting solution for composition shingle roofs Part#850-1511 Part#850-1397 Works with all Zep Compatible Modules Auto bonding UL-listed hardware creates structural and electrical bond ®rna,� 0 e0 I ZS Span has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as"Type 1"or"Type 2" Roo � 11 . MOUNTING BLOCK L FLASHING INSERT FAc/ v V L LISTED Listed to UL 2703 Listed to UL 2703 and UL 2582 for Wind Driven Rain pp�� Part#850-1633 Part#850-1628 e* O O,�P SPECIFICATIONS Designed for pitched roofs o Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 Engineered for compliance with ASCE 7-16 wind load requirements CAPTURED WASHER LAG 7 INTERLOCK ZS Comp grounding products are UL listed to UL 2703 and UL 467 Part#850-1631-002 and#850-1631-004 Listed to UL 2703 ZS Comp bonding products are UL listed to UL 2703 Part#850-1613 or#850-1388 Engineered for spans up to 72"and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices END CAP . ARRAY SKIRT Part#850-1586 or 850-1460(Left) Listed to UL 2703 Part#850-1588 or 850-1467(Right) Part#850-1608 or#500-0113 <I SKIRT GRIP . DC WIRE CLIP Listed to UL 2703 Listed to UL 1565 Part#850-1606 or#850-1421 Part#850-1509 ZS COMP DATASHEET 2 T = 5 L n ZS COMP DATASHEET 3 PVRSA Model: ZS Rapid Shutdown Array (Applicable to ZS Comp,ZS Span,ZS Ramp,and ZS Seam) Category OIJR, Report Date:2020-05-01 TABLE OF ESSENTIAL ELEMENTS Function Manufacturer Model No. Firmware Versions Certification Standard and Checksums PVRSE Mid Circuit Delta Electronics GPI000101102 2.1.6 UL 1741 PVRSE Interrupter(MCI) Sys:2.2.11 Inverter Delta Electronics M4,M5,M6,M8,M10 Pwr:1.4.9 UL 1741 Safety:1.4.3 Q.PEAK DUO BLK-G5/SC315 PV Module Hanwha Q-CELLS N/A UL 1703 Q.PEAK DUO BLK-G5/SC320 ZEP 850-1613-001 Interlock Tesla ZEP 850-1388-001 N/A UL 2703 ZEP 850-1281-001 ZEP 850-1511-001 UL 467 Ground Zep Tesla ZEP 850-1172-002 N/A UL 2703 DC Wire Clip Tesla ZEP 850-1509-001 N/A UL 1565 ZEP 850-1448-001 Homerun Wire Clip Tesla ZEP 850-1510-001 N/A UL 1565 PVRSA Initiator' Non-Specific N/A N/A N/A (See installation req.below) 1 Dedicated PV system AC circuit breaker or AC disconnect switch,labeled per NEC 690.12 requirements. 2 Applies to variations of this part number,e.g.suffixes. Note:PVRSA installation requirements may reduce the effective equipment and component ratings below the individual equipment and component PVRSE ratings in order to achieve PVRSA shock hazard reduction requirements. PVRSA INSTALLATION REQUIREMENTS Max System Voltage 600 VDc Max Array Internal Voltage After Actuation 165 VDc(cold weather open circuit) Max Series-Connected Panels between MCI Output Connections: 3 Max Series-Connected Panels Connected to MCI Inputs: 1 OTHER INSTALLATION INSTRUCTIONS 1. MCIs shall be mounted to module frames with Delta-supplied brackets. 2. An MCI must be connected to one end of each series string or sub-array string. 3. Verification that MCIs are installed with 3 or fewer modules between MCI output connections shall be documented for inspection,by voltage measurement logs and/or as-built string layout diagrams. 4. The dedicated PV system AC circuit breaker or PV system AC disconnect switch shall serve as the PVRSA initiator and shall be sized and installed in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. 0 ® Certification Mark of UL on the installation instructions is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service.The Certification Mark for these products includes the UL symbol,the words"CERTIFIED"and "SAFETY",the geographic identifer(s),and a file number.