Item 10 - Plans DESIGN BY: SCOPE OF WORK FREEDOM SOLAR,LLC TO INSTALL A SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE GATES RESIDENCE, LOCATED AT 1211 TIMBER COURT,SOUTHLAKE,TEXAS. 71 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED Gaylo REVISIONS WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. &C0 DESCRIPTION DATE REv DESIGN PACKET 01/30/2021 A THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. � DESIGN PACKET 03/18/2021 B 1 _ Southlake SYSTEM RATING gip" Keller Walmart Supercenter Q 18.6 kW DC STC 1211 Timber 18.0 kW AC - C1.Southlake,TX... 10 CONTRACTOR al EQUIPMENT SUMMARY •/ � So ARE POWER Lowe's Home FREEDOM SOLAR LLC (57) SUNPOWER SPR-E20-327-E-AC PV MODULES 4801 FREIDRICH LN,STE 100 Im rovemerl' AUSTIN,TX 78744 (57) SUNPOWER SPR-E20-327-E-AC[240VI PV INVERTERS p TELL#28621 (452) (42 X 10.75')LINEAR FEET SUNPOWER INVISIMOUNT 121 TBPE FIRM#F-17690 PROJECTNAME Target Q N rnilpyvillp rn SHEET INDEX PROJECT LOCATION co Df PV-0 COVER o PV-1 SITE MAP AND PV LAYOUT L) } U X PV-2 STRING MAP AND MONITORING LAYOUT E PV-3 ELECTRICAL DIAGRAM LLIDf W PV-4 EQ WALL&MOUNTING DETAIL � co � CN N PV-5 SYSTEM LABELING DETAIL Ljj LU ~ PV-6 SAFETY PLAN I.-Z Timber Ct < J N N � 0 GOVERNING CODES 1211�TImber Ct.Southlake.TX. 2020 NATIONAL ELECTRICAL CODE SHEET NAME 2018 INTERNATIONAL RESIDENTIAL CODE 2018 INTERNATIONAL FIRE CODE UNDERWRITERS LABORATORIES(UL)STANDARDS COVER OSHA 29 CFR 1910.269 SHEETSIZE ANSI B 11"x17" PV Installation SHEET NUMBER Professional PV_0 Mark McManus VICINITY MAP Cert#PV-0421 1 8-0205 34 DESIGN BY: LEAD ID: 38723 FREEDOM SOLAR,LLC CONSTRUCTION SUMMARY (57) (SUNPOWER SPR-E20-327-E-AC)SOLAR MODULES, 18.6 kW DC ST REVISIONS MODULE DIMENSIONS=41.2"X 61.3"X 1.80" DESCRIPTION DATE REV (57) SUNPOWER SPR-E20-327-E-AC[240VI PV INVERTERS DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/18/2021 B COMBINED INVERTER OUTPUT= 18.0 kW AC. (420) (39 X 10.75')LINEAR FEET SUNPOWER INVISIMOUNT 3 0 (108) SPCR-CH ROOF ATTACHMENTS a (1) SUNPOWER MONITORING V ARRAY i' �- � , (7)MODULES 0 SITE DETAILS T CONTRACTOR � , IRE CODE SETBACK -_ ROOF TYPE:ASPHALT SHINGLE . PER IFC 1204.2.1 -- ARRAY#1 -TILT=24°,AZIMUTH = 178' ARRAY#2-TILT=24°,AZIMUTH = 178' ARRAY#3-TILT=24°,AZIMUTH = 178° `� �e'{ " r, FREEDOM' DETAIL: V ARRAY#1 - FREEDOM SOLAR LLC SUNPOWER INVISIMOUNT RAIL(TYP. (32)MODULES _ 4801 FR AUSTIN,HLN,STE too TIN,TX 78744 UTILITY CONTROLLED OUTAGE REQUIRED TO TBPE FIRM#8F-17690 SPCR-CH ROOF ATTACHMENT(TYP. ROUNDING ELECTRODE INSTALL NEW EXTERIOR EATON CH8B200RF SUNPOWER PV MODULE (TYP. MAIN DISTRIBUTION PANEL#1 PROJECT NAME -INSIDE HOUSE FEED-THROUGH PANEL WITH CSR220ON MBK. RAFTER(TYP.)ON 24"CENTER -MOVING FEEDER BREAKERS TO GARAGE N NCOR REVENUE METER (100A) & GUEST HOUSE (125A) SUB PANELS p SOLAR LOAD CENTER #147 630 683 TO THE NEW FEEDTHROUGH PANEL. CD ESID#10443720002664515 ry PV AC DISCONNECT -(2) SEPARATE EQ WALLS. jr NEW FEED-THROUGH PANEL u1 O -VISIBLE BREAK SOLAR LOAD CENTER J U X -LABELED-LOCKABLE MONITORING ~ W H N -LOCATED WITHIN 50'OF PV AC DISCONNECT W coLLI -VISIBLE BREAK �_ Y ONCOR REVENUE METER -LOCKABLE Q Q -LABELED O J 04 -LOCATED WITHIN 10'OF N H GROUNDING ELECTRODE ONCOR REVENUE METER D MAIN DISTRIBUTION PANEL#2 O (A INSIDE GARAGE .. r V ARRAY#3 "c iieh (E) EXISTING DETACHE (18)MODULES SHEET NAME STRUCTURE _. SITE MAP& _ PV LAYOUT PV Installation Professional Mark McManus - SHEET SIZE Cert#PV-042118-020534 ANSI B CONSTRUCTION NOTES 11"X 17" 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ROUNDING ELECTRODEE SHEET NUMBER 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. MAIN DISTRIBUTION PANEL#3 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. PV-1 4.)TYP.ROOF ATTACHMENT SPACING SHALL BE 6-0"MAX FOR LAG BOLT TYPE ROOF ATTACHMENTS ANCHORED TO RAFTERS 5.)TYP.ROOF ATTACHMENT SPACING SHALL BE 4'-6"MAX FOR S-5!CLAMPS ANCHORED TO STANDING SEAM ROOF PANELS DESIGN BY: FREEDOM SOLAR,LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN,STE 100 AUSTIN,TX 78744 TECL#28621 TBPE FIRM#F-17690 PROJECT NAME N m O (9 w O Cf) Ln J U X -7 Of LLJ Lr) W F-- N (n 00LLJ LLI Ur J N 2 N � O U) SHEET NAME STRING MAP MONITORING LAYOUT SHEET SIZE ANSI B 11"x 17" PV Installation Professional SHEET NUMBER Mark McManus SUNPOWER SUPERVISOR S/N Pv_2 Cert#PV-0421 18-020534 DESIGN BY: FREEDOM SOLAR,LLC REVISIONS DESCRIPTION DATE REV DESIGN PACKET 01/30/2021 A DESIGN PACKET 03/16/2021 B CONTRACTOR FREEDOM" SOLAR POWER FREEDOM SOLAR LLC 4801 FREIDRICH LN,STE 100 AUSTIN,TX 78744 TECL#28621 TBPE FIRM#F-17690 PROJECT NAME N m O (9 W O Cf) LO J U X -7 Of w Lr, W F-- N (n 00LLJ LLI Ur J N 2 N � 0 SHEET NAME STRING MAP MONITORING LAYOUT SHEET SIZE ' ANSI B 11"x 17" PV Installation Professional EpV-2A HEET NUMBER SUNPOWER SUPERVISOR S/N Cert Mark McManus UTILITY CONTROLLED OUTAGE REQUIRED TO DESIGN BY: INSTALL NEW EXTERIOR EATON CH8B200RF FREEDOM SOLAR,LLC SOLAR ARRAY - 12.8kW DC STC ONCOR REVENUE METER (39) (SUNPOWER SPR-E20-327-E-AC) MODULES FEED-THROUGH PANEL WITH CSR220ON MBK. M #147 630 683 ESID#10443720002664515 JUNCTION BOX: 1-PHASE,240V REVISIONS TRANSITION FROM DG CABLE (3)AWG 2/0 CU THWN-2 DESCRIPTION DATE REV IN 2"CONDUIT POINT OF INTERCONNECTION DESIGNPACKET 01/30/2021 A TO AWG ON THWN-2 NEMA 3R, UL LISTED PV AC DISCONNECT#1 PER NEC 240.21(B)(1)-OR-705.31 DESIGN PACKET oansz°z, B LENGTH OF TAP CONDUCTORS BRANCH#1 SOLAR LOAD CENTER#1 240VAC, 100A SHALL NOT EXCEED 10 FT FROM 240 VAC, 125A FUSIBLE,WITH (2)70A FUSES POINT OF INTERCONNECT TO OCPD ES e 8 11 MODUL NEMA 3R, UL LISTED NEMA 3R, UL LISTED 2ooA BRANCH#2 (5)2P-20A BREAKERS VISIBLE, LOCKABLE, LABELED MAIN SERVICE DISCONNECT WITHIN 10'OF THE ONCOR TO 240V,200A 8 11 MODULES e ti 20A REVENUE METER GUEST 125A ti ti NEW FEED-THROUGH PANEL CONTRACTOR 2oA #3 70A HOUSE look- BRANCHEATON CH8B200RF(UPGRADE) 20A8 10 MODULES e ti ti 20A 1 P3W,240V,225A BUS -- BRANCH#4 zoA r— ----- — 100A FEEDER BREAKER ti 8 7 MODULES ti (3)AWG 2/0 CU THWN-2 FREEDOM" SOLAR POWER -- -- — ---- (1)AWG#6 THWN-2 GND FREEDOM SOLAR LLC IN 2"CONDUIT 4801 FREIDRICH LN,STE 100 AUSTIN,TX 78744 (39)(SUNPOWER SPR E20-327-E-AC TECL#28621 [240])INVERTERS EXISTING MAIN DISTRIBUTION PANEL TBPE FIRM#F-170s0 240VAC, 1.31A MAX SUNPOWER (3)AWG#6 THWN-2 GE,1P3W PROJECT NAME CEC WEIGHTED EFFICIENCY 97.5% MONITORING (1)AWG#8 THWN-2 GND 240V,200A BUS NEMA 4R, UL LISTED, INTERNAL GFDI IN 1"CONDUIT I -INSIDE HOUSE N (8)AWG#10 THWN-2 rn I C:) (1)AWG#8 THWN-2 GND 0-1 IN 3/4"CONDUIT ct D EXISTING WIRES J 0 Q LO SOLAR ARRAY - 5.89kW DC STC } v x PV AC DISCONNECT#2 EXISTING GROUNDING I— of W Lo (18) (SUNPOWER SPR-E20-327-E-AC) MODULES 240VAC,60A ELECTRODE SYSTEM uj LLI 1-- � JUNCTION BOX: FUSIBLE,WITH (2)40A FUSES W W SOLAR LOAD CENTER#2 1-- TRANSITION FROM DG CABLE NEMA 3R, UL LISTED Q Q TO AWG#10 THWN-2 240 VAC, 125A VISIBLE, LOCKABLE, LABELED J NEMA 3R, UL LISTED NEMA 3R, UL LISTED WITHIN 50'OF THE ONCOR EXISTING GARAGE PANEL N H (2)2P-20A BREAKERS REVENUE METER 1o0A GE, 1P3W,240V, 125A BUS O BRANCH#1 20A 40A POINT OF INTERCONNECTION U) 8 9 MODULES e ti 20A PER NEC 240.21(B)(1)-OR-705.31 ——— —— — —————— ———— LENGTH OF TAP CONDUCTORS BRANCH#2 SHALL NOT EXCEED 10 FT FROM SHEET NAME ti 9 MODULES ti ti POINT OF INTERCONNECT TO OCPD ———— ELECTRICAL EXISTING GROUNDING DIAGRAM (14)(SUNPOWER SPR E20-327-E-AC ELECTRODE SYSTEM [ (4)AWG#6 THWN-2 240])INVERTERS ilk 240VAC, 1.31A MAX (1)AWG#8 THWN-2 GNDSHEET SIZE CEC WEIGHTED EFFICIENCY 97.5% IN 1"CONDUITNEMA 4R, UL LISTED, INTERNAL GFDI ANSI B -MOVING FEEDER BREAKERS TO GARAGE 11"x 17" (4)AWG#10 THWN-2 (100A) & GUEST HOUSE (125A) SUB PANELS (1)AWG#8 THWN-2 GND TO THE NEW FEEDTHROUGH PANEL. Professional PV Installation SHEET NUMBER IN 3/4"CONDUIT -(2) SEPARATE EQ WALLS. Mark McManus PV-3 Cert#PV-042118-020534 DESIGN BY: MAIN HOUSE ELECTRICAL CALCULATION:- FREEDOM SOLAR,LLC CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES INVERTER OUTPUT WIRE AMPACITY CALCULATION INVERTER BRANCH AC CURRENT CALCULATION [NEC 690.8(A)(3)]:1.31A PER INVERTER (SUNPOWER SPR-E20-327-E-AC[240V]) [NEC 690.8(A)(3)1:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) REVISIONS MAXIMUM INVERTER BRANCH CURRENT=(12)(1.31A)=15.7A MAXIMUM BRANCH INVERTER CURRENT=(12)(1.31A)=15.7A DESCRIPTION DATE REV CONTINUOUS USE: MINIMUM OCPD=(15.7A)(1.25)=19.6A DESIGN PACKET 01/30/2021 A #10 WIRE 75°C DERATED AMPACITY =(0.80)(35.0A)=28.OA USE 2P-20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD 28.OA>15.7A DESIGN PACKET 03/16/2021 B CONDITIONS OF USE: SYSTEM AC CURRENT CALCULATION #10 WIRE 90°C DERATED AMPACITY=(0.91)(0.7)(40.OA)=25.5 [NEC 690.8(A)(3)1:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) 25.5 15.7A COMBINED CURRENT=(39)(1.31A)=51.1A MINIMUM OCPD=(51.1A)(1.25)=63.9A SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION USE(2)70A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD [NEC 690.8(A)(3)1:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) NOTE:AWG#6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 70A FUSES COMBINED CURRENT=(39)(1.31A)=51.1A CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY =(0.80)(65A)=51.1A 52.OA>51.1A CONTRACTOR CONDITIONS OF USE: .. _ #6 WIRE 90°C DEBATED AMPACITY=(0.91)(75A)=68.3A 68.3A>51.1A FREEDOM" SOLAR POWER FREEDOM SOLAR LLC GARAGE ELECTRICAL CALCULATION:- 4801 FREIDRICH LN,STE 100 AUSTIN,TX 78744 TECL#28621 CALCULATIONS FOR CURRENT CARRYING CONDUCTORS CALCULATIONS FOR OVERCURRENT DEVICES TBPE FIRM#F-17690 INVERTER OUTPUT WIRE AMPACITY CALCULATION INVERTER BRANCH AC CURRENT CALCULATION PROJECT NAME [NEC 690.8(A)(3)]:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) [NEC 690.8(A)(3)]:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) MAXIMUM INVERTER BRANCH CURRENT=(12)(1.31A)=15.7A MAXIMUM BRANCH INVERTER CURRENT=(12)(1.31A)=15.7A CONTINUOUS USE: MINIMUM OCPD=(15.7A)(1.25)=19.6A (V #10 WIRE 75°C DERATED AMPACITY =(0.80)(35.0A)=28.OA USE 2P-20A BREAKERS IN SOLAR LOAD CENTER FOR INVERTER BRANCH OCPD O') 28.OA>15.7A O CONDITIONS OF USE: SYSTEM AC CURRENT CALCULATION #10 WIRE 90°C DERATED AMPACITY=(0.91)(0.80)(40.OA)=29.1A [NEC 690.8(A)(3)1:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) ~ 29.1A>15.7A COMBINED CURRENT=(18)(1.45A)=23.6A MINIMUM OCPD=(23.6A)(1.25)=29.5A L[J O Q Lo SOLAR LOAD CENTER OUTPUT WIRE AMPACITY CALCULATION USE(2)40A FUSES IN PV AC DISCONNECT FOR SYSTEM OCPD -J („) (D [NEC 690.8(A)(3)]:1.31A PER INVERTER(SUNPOWER SPR-E20-327-E-AC[240V]) NOTE:AWG#6 CONDUCTORS ARE ADEQUATELY PROTECTED BY 40A FUSES X 1 COMBINED CURRENT=(18)(1.31A)=23.6A ~ w I-- N CONTINUOUS USE: #6 WIRE 75°C DERATED AMPACITY =(0.80)(65A)=52.OA U7 m w � 52.0>23.6A LU �_ Y � CONDITIONS OF USE: Q Q #6 WIRE 90°C DERATED AMPACITY=(0.91)(75A)=68.3A Ur J CV 68.3A>23.6A N � O U) ELECTRICAL NOTES 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90°C WET ENVIRONMENT UNLESS OTHERWISE NOTED. SHEET NAME 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. ELECTRICAL 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. DIAGRAM 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, SHEET SIZE THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. ANSI B 8.)MAXIMUM MOUNTING HEIGHT FROM GRADE TO CENTER OF METER SOCKET SHALL BE 72" FOR RESIDENTIAL SINGLE PHASE METER SOCKETS 0-320 AMPS.MINIMUM MOUNTING HEIGHT IS 11"X 17" 30"FROM FOR AUSTIN ENERGY,AND 48"FOR ALL OTHER JURISDICTIONS 9.)MINIMUM HORIZONTAL CLEARANCE FROM GAS REGULATOR TO ANY ELECTRICAL ENCLOSURE IS 36",EXCEPT AUSTIN ENERGY WHICH REQUIRES 48"CLEARANCE FROM GAS TO METER SOCKET PV Installation 10.)PV DISCONNECT SHALL BE VISIBLE,LOCKABLE AND LABELED AND THE DOOR CANNOT BE Professional SHEET NUMBER OPENED WHEN HANDLE IS IN ON POSITION 11.)BY DEFAULT THE MONITORING DEVICE IS SHOWN CONNECTED TO A 20-AMP BREAKER IN THE Mark McManus PV-3A SOLAR LOAD CENTER.ALTERNATIVELY,THE MONITORING DEVICE MAY BE CONNECTED TO A Cert#PV-0421 1 8-020534 20-AMP BREAKER AT THE MAIN DISTRIBUTION PANEL. DESIGN BY: NEW FEED-THROUGH PANEL FREEDOM SOLAR,LLC - OUTSIDE HOUSE WALL - POINT OF INTERCONNECTION REVISIONS MAIN DISTRIBUTION PANEL#1 PV Installation DESCRIPTION DATE REV - INSIDE MAIN HOUSE WALL Professional DESIGN PACKET 01/30/2021 A Mark McManus DESIGN PACKET 03/16/2021 B MAIN DISTRIBUTION PANEL#2 PV AC DISCONNECT#1 Cert#PV-042118-020534 - INSIDE GARAGE WALL PV AC DISCONNECT#2 SOLAR LOAD CENTER#1 SOLAR LOAD CENTER#2 FROM PV ARRAY CONTRACTOR FROM PV ARRAY i mmmm I I FREEDOM" O SOLAR POWER I FREEDOM SOLAR LLC 4801 FREIDRICH UN,STE 100 AUSTIN,TX 78744 TECL#28621 TBPE FIRM#F-17690 PROJECT NAME ONCOR REVENUE MONITORING N METER o EQUIPMENT ELEVATION LLI 0 CQ LQ NTS U X ~ W N (n m LLI GROUNDING END/MID CLAMP Q Q PV MODULE U J N PV MODULE �% SUNPOWER INVISIMOUNT N .� RAIL ALUMNI."L"BRACKET SEE(3/PV4-EQ W/3/8"SS BOLT&NUT WALL)FOR COMPOSITE ENLARGED SHINGLE ROOF VIEW @Tx OO �BRS (E)COMPOSITE SHINGLE ROOF SHEET NAME 2y6� SUNPOWER FLASHING, 5/16"x3"SS LAG BOLT WITH MIN 12"x12"x0.050",5050,MILL 2y2"THREAD EMBEDMENT, EQ.WALL& SEALED PENETRATION INTO RAFTERS MOUNTING DETAIL 2X6 RAFTERS @ 24"OC SHEET SIZE ANSI B 11"x 17" SHEET NUMBER MOUNTING METHOD 2 MOUNTING DETAIL [3] PV �F- NTS NTS DESIGN BY: FREEDOM SOLAR,LLC NOTE:NOT ALL LABELS MAY BE APPLICABLE SIGNAGE REQUIREMENTS REVISIONS >RED BACKGROUND DESCRIPTION DATE REV >WHITE LETTERING DESIGN PACKET 01/50/2021 A >MIN.3/8"LETTER HEIGHT DESIGN PACKET 03/16/2021 B >ALL CAPITAL LETTERS >ARIAL OR SIMILAR FONT >REFLECTIVE,WEATHER RESISTANT WARNING MATERIAL, UL 969 ELECTRIC SHOCK HAZARD. .• NOT TOUCH TERMINALS ON ■ POWER SOURCEOUTPU CONTRACTOR • ■ SIDES ENERGIZED IN THE OPEN RELOCATE POSITION. OVERCURRENT DEVICE I • • • -- REQ'D BY:NEC 690.13(B) REQ'D BY: NEC 690.13(13) REQ'D BY:NEC 690.31(G)(3) F REQ'D BY: NEC 705.12(B)(2)(3)(b) FREEDOM"' H [3 �. u SOLAR POWER APPLY TO: APPLY TO: APPLY TO: APPLY TO: FREEDOM SOLAR LLC PV DISCONNECT PV DISCONNECT RACEWAYS,CABLE TRAYS, DISTRIBUTION EQUIPMENT aeol FRw,STE too AUSTIN, HTIN,TX 78744 OTHER WIRING METHODS,AND ADJACENT TO BACK-FED BREAKER TECL#26621 TBPE FIRM#F-17690 ENCLOSURES THAN CONTAIN PV SYSTEM DC CONDUCTORS PROJECT NAME N O O W O U) L0 REQ'BY:AHJ LE REQ'D BY:AHJ F REQ'D BY: FREEDOM SOLAR X APPLY TO: APPLY TO: APPLY TO: ~ W I— N REVENUE METER SOCKET REVENUE METER SOCKET MONITORING DEVICE ENCLOSURE U) 00 LLj (IF APPLICABLE) (IF APPLICABLE) Q Q ( J 2 N I— Z) SOLAR PV SYSTEM EQUIPPED 0 WITH RAPID SHUTDOWN PHOTOVOLTAIC AC DISCONNECT TURN RA%DSHUTDOWN OPERATING CURRENT: _ _'S NTO SHUT OOWN PV SYSTEMANDREDUOE SHEET NAME OPERATING VOLTAGE: SHOCK H-RD IN THE SYSTEM LABELING REQ'D BY:690.56(1)(a) REQ'D BY: FREEDOM SOLAR LI DETAIL APPLY TO: APPLY TO: PV DISCONNECT MAIN DISTRIBUTION PANEL ; SHEET SIZE ANSI B 11"x 17" PV Installation Professional SHEET NUMBER Mark McManus PV-5 Cert#PV-0421 18-020534 DESIGN BY: DRAW IN CONTROLLED ACCESS ZONE (CAZ) BOUNDARY AND LADDER FREEDOM SOLAR,LLC PLACEMENT ON SITE PLAN BELOW. PV Installation Professional REVISIONS HARD HAT IS REQUIRED AT ALL TIMES IN CAZ Mark McManus DESCRIPTION DATE REV Cen#PV-042118-020534 DESIGN PACKET 1113012021 A DESIGN PACKET OaI 2021 B TIMBER COURT CONTRACTOR FREEDOM" SOLAR POWER • FREEDOM SOLAR LLC ° 4801 FREIDRICH LN,STE 100 ° ❑ AUSTIN,TX 78744 1 TECL#28621 TBPE FIRM#F-17690 PROJECT NAME i N CONDUCT SAFETY MEETING WITH ALL CREW o MEMBERS ON SITE AT THE BEGINNING OF EACH JOB. `ram° LEI SIGN IN SHEET BELOW. O Q C:) X 0-1 Uj 1 ~ W N u) Co 2. Q Q ( = N 3. N M 4 O 5. 6 SHEET NAME SAFETY PLAN GUEST SIGN IN 1 SHEET SIZE 2 ANSI B 11"x 17" 3. COMPETENT PERSON: JOB START DATE: SHEET NUMBER PV-6 E-Series:E20-327 I E19-320 SunPower°Residential AC Module SUNPWER`R AC Electrical Data Inverter Model:Enphase IQ 7)(S(IQ7xS-96-ACM-US) @240 VAC @208 VAC Peak Output Power 320 VA 320 VA Sunftwer®E-Series: E20-327 I E19-320 Max.Continuous Output Power 315 VA 315 VA Nom.(LA)Voltage/Range2 M 240/211-264 208/183-229 SunPower° Residential Max.Continuous Output Current o1.51 p Max.Units per 20 A(FL)Branch Circircuit3 12(singlegle phase) 10(two pole)wye AC Module CEC Weighted Efficiency 97.54fi 97.04U Nom.Frequency 60 Hz Extended Frequency Range 47-68 Hz Built specifically for use with the SunPower Equinox'"system,the only fully AC short Circuit Fault Current over 3 Cycles 5.8 A rms integrated solution designed,engineered,and warranted by one Overvoltage Class AC Port III manufacturer. AC Port Backfeed Current 18 mA Power Factor Setting 1.0 Maximum Power.Minimalist Design. Power Factor(adjustable) 0.7lead./0.7lag. �i-FA No active phase balancing for three-phase installations ii Industry-leading efficiency means more power and savings iiAL-1i per available space.With fewer modules required and DC Power D• • Warranties,Certiflcations,and Compliance hidden microinverters,less is truly more. SPR-E20-327-E-AC SPR-El9-320-E-AC Warranties '25-year limited power warranty Nom.Power I(Pnom) 327 W 320 W •25-year limited product warranty Power Tol. +5/-0% +5/-0% •UL 1703 Certifications 'UL 1741/IEEE-1547 Highest Lifetime Energy and Savings. Temp. Efficiency 20.4% 19.94b and UL 1741 AC Module(Type 2firerated) Designed to deliver 60%more energy over 25 ears in Temp.Coef.(Power) -0.35%/°C -0.35%/°C Compliance UL 62109-1/IEC 62109-2 g y •FCC Part 15 Class B real-world conditions like partial shade and high tem eratures.' -Three bypass diodes ICES-0003 Class B g P Shade Tol. •Integrated module-level maximum •CAN/CSA-C22.2 NO.107.1-01 power point tracking •CA Rule 21(UL 1741 SA)4 Sow ?� 1 (includes VolWar and Reactive Power Priority) ww a lsow �•_ • • UL Listed PV Rapid Shutdown Equipmentb Fundamentally Different. ,o Operating Temp. -40°F to+185°F(-40°C to+g5°C) And Better. ru 120% SunPowei Up to Enables installation in accordance with: 'r now 60% Max.Ambient 122°F(50°C) •NEC 690.6(AC module) l oow more Max.Load Wind:62 psf,3000 Pa,305 kg/m'front&back •NEC 690.12 Rapid Shutdown(inside and outside the array) `y Snow:125 psf,6000 Pa,611 kg/m2 front Sow lifetime •NEC 690.15 AC Connectors,690.33(A)-(E)(1) c d Impact Resistance 1 inch(25 Fri diameter hail at 52 mph(23 m/s) Bow energy dConventional Module When used with InvisiMount racking and InvisiMount accessories 70w MechanicalD. • (UL 2703): N 60% Solar Cells 96 Monoc stalline Maxeon Gen III •Module grounding and bonding through InvisiMount o s 10 1s zo zs ry •Class A fire rated The SunPower®Maxeon®Solar Cell Front Glass High transmission tempered glass with When used with AC module Q Cables and accessories(UL 6703 and Years of operation Enables highest-efficiency anti-reflective coating UL 2235)s: • modules available. z Environmental Rating Outdoor rated •Rated for load break disconnect Unmatched reliability3 ^ Best Reliability.Best Warranty. Frame Class black anodized(highest AAMA rating) PIDlest Potential-induced degradation free • IWMWM�J Patented solid metal foundation With more than 25 million modules deployed around weight 42.9Ids(19.5 kg) Ssemmc6,.3m.) -� • Recommended Max. prevents breakage and corrosion the World,SunPower technology is proven to last.That's Module Spacing 1.3 in.(33 Firm) why we stand behind our module and microinverter 1 SunPower 360 W compared to a conventional module on same-sized arrays(260 W,16% 46mm with the industrys best 25 year Combined Power and efficient,approx.1.6n 445moreenergyperwatt(basedouthird-party module characterization and PVSim),0.7590/yr slower d egradation(Campeau,Z.et al."SunPower Product Warranty,including the highest Power Warranty Module Degradation Rate,"SunPowerwhite paper,2013). i 2 Based on search ofdatasheet values from websites oftop 10manufacturers perlHS,asof In Solar. January2017. fu.l in., 3#1 rank in"Fraunhofer PV Durability lnitiativeforSolar Modules:Pan 3."PVrech Power _ ~ d loow Magazine,2015.Campeart,Z.etal."SunPowerModule Degradation Rate;'SunPowerwhite 4 paper,2013. p98% 4Factory set to 1547a-2014 defaultsettings.CA Rule 21 default settings profile set during 393mm Factory-integrated Microinverter s 96% commissioning.Seethe Equinox Installation Guide#518101 formore information. (155m.1 d 5 Standard Test Conditions(1000 W/m2 irradiance,AM 1.5,25°Q.NREL calibration • Simpler,faster installation o 94w i p .a 9zw standard:SOMScurrent,LACCS mandvoltage.All Duvall is fully contained within the • Integrated wire management, £ 92% 12% module. 437mm 6 This product is UL Listed as PVRSE and conforms with NEC 2014 and NEC 2017 690.12; (172 rn) rapid shutdown 0 88% m more andC22.1-2015Rule64-218RapidShutdownofPVSystems,forACandDCconducrs; abw when installed accordingto manufacturer's instructions. Engineered and calibrated by• L 84% power O In year See wwwsunpoweccomffacLs for more reference information. ` _ SunPower for SunPower modules s82%o% 25 For more details,see extendeddatasheetwvmv.sunpoweccom/darasheets wee bw'140 C C 3 Clow Specifications included inthis datasheet are subject to change without notice. �[�f17•n0 S U N POW E R`�° 0 5 15 20 z5 02018 SunPower Corporation.All Rights Reserved.SUNPOWER,the Al."lih.ralmmmer:79p2 Sri NPOWER Iogo and MAXEON are registered trademarks of SunPower Years of operation Corporation in the U.S.and other countries as well.1-800-SUNPOWER. Please read the Safety and Installation Instructions for details. 531948 RevA �• sunpower.com Sun Power"' nd _ Residential I Commercial • _ — SunPower Monitoring Websites PVS6 SunPower AC Modules '• c' r4 ' • I • - ' • �- - - � - _ Improve Support, - Qy Reduce Maintenance Costs SunPower EnergyLink—Plug-and-Play Installation °= _ An intuitive monitoring website enables you to: This complete solution for residential and commercial monitoring and --• �- See a visual map of customer sites control includes the SunPower®PV Supervisor 6(PVS6)which improves _- Remotely manage hundreds of sites the installation process,overall system reliability,and customer — - Receive elective system reports experience. p II Multiple communication options include NO 11IVIi aye i_ ; Ethernet,Wi-Fi,and cellular. Locate system issues and remotely diagnose Compact footprint for improved aesthetics Diagnose issues online Robust cloud connectivity and comprehensive local connectivity - - '- Drill down for the status of individual devices Flexible configuration of devices during installation Consumption metering Site Requirements Operating C• • • Revenue-grade production metering(pending) Number of SunPower AC modules 85 Temperature -22°Fto+140°F(-30°Cto+60°C) _ -- — supported per PVS6 Web-based commissioning Humidity(maximum) 1 9595,non-condensing Internet access High-speed internetaccess via accessible 1dd111 " _ Remote diagnostics of PVS6 and inverters router or switch Durable UL Type 3R enclosure reduces maintenance costs Power 100-240 VAC(L-N),50 or60 Hz __ --'-- Easy integration with SunPower eBOS 208VAC(L-Lin3-phase),60HzCommunicatlon -= RS-485 Inverters and meters • one channel of revenue-grade production metering ffTAY4l Id Integrated Metering .Two channels of consumption metering Add Value for Customers Weight 5.5 lbs(2.5 kg) Ethernet 1 LAN(or optional WAN)port Robust Cloud ConnectivityDimensions 11.8x8.0x4.2in.(30.5x20.5x10.8cm)With the SunPower Monitoring System PLC PLC for SunPower AC modules SU."jPOWER Multiple tionstomaintaino optimal Enclosure rating UL50E Type 3R customers can: - p p p Wi-Fi 802.11 b/g/n 2.4 GHz and 5 GHz See what their solar system produces each connectivity: Cellular LTE Cat-M1/3G UMTS day,month,or year Hardwired Ethernet Zil IEEE 802.15.4 MAC,2.4GHz ISM band Optimize their solar investment and save on Wi-Fi • • Mobile Support Data Storage 60 days energy expenses Customer site monitor.us.sunpower.com • Cellular backup Upgrades Automatic firmware upgrades See their energy use and estimated bill savings Partner site �,gmt.ussunpower.com See their solar system's performance using the Browsers Firefox,Safari,and Chrome SunPower monitoring website or mobile app Mobile devices iPhone®,iPad®,and Android- Customer app 1.Create account online at:monitor.us.sunpower.com. •Certifications 2.On a mobile device,download the SunPower Monitoring Warranty 10-year Limited Warranty app from Apple App Store"'or Google PlayTM ore. 3.Sign in using account email and password. Certifications UL,Cut,CE,UL 61010-1 and-2,FCC Part 15(Class B) il c&us Fl LISTED �•. , FCC ID:YAW529027 E503346 WE . 1► of'Google Inc.All other tradernarks are the property aFtheirr�pecb���m.Specifi�ti�imkided in thisdamsheetar—1 o D. v v •� o ftei I 1 • 0 • InvisiMount Components Simple and Fast Installation Module'/Mid Clamp and Rail Module'/End Clamp and Rail Integrated module-to-rail grounding Pre-assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates consistent,even Ground Lug Assembly module spacing Row-to-Row Spacer UL 2703 Listed integrated grounding End clamp Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait with up to 8' Mid Clamp slow rail span Rail and Rail splice Row-to-Row Grounding Clip • Pre drilled rails and rail splice -' InvIslMount Component Details InvisiMount Operating Conditions Rails enable easy obstacle management Mid damp Black oxide stainless steel 300 series 63 g(2.2 oz) Temperature —40°C to 900 C(-40°F to 1940 F) End clamp Black anodized aluminum 6000 series 110 g(3.88 oz) 3000 Pa uplift Max.Load(LRFD) Customer-Preferred Aesthetics Rail Black anodized aluminum 6000 series 830 g/m(9 oz/ft) 6000Padownforce #1 module and#1 mounting aesthetics Elegant Simplicity Rail splice Aluminum alloy 6000 series 830 g/m(9 oz/ft) Best-in-class system aesthetics Rail bolt M10-1.5 x 25 mm;custom T-head SS304 18 g(0.63 oz) Y R•• • Supported• •� •• Premium,low-profile n SunPowerOInvisiMountTM' is SunPower-designed Rail nut M10-1.S;DIN692355304 nominal Composition Shin le Rafter Attachment p g Ground lug SS304;A2-70 bolt;tin-plated copper lug 106.5 g(3.75 oz) Composition Shingle Roof DeckingAttachment Black anodized components rail-based mounting system.The InvisiMount system assembly Application Curved and Flat T eRoofAttach ent Row-to-row SS 301 with SS 304 M6 bolts 75 g(2.6 oz) Universal interface for other roof attachments Hidden mid clamps and capped,flush addresses residential sloped roofs and combines faster grounding clip end clamps Row-to-row Black POM-grade plastic 5 g(0.18 oz) installation time,design flexibility,and superior aesthetics. s acer InvisiMount _RFD CapacitieS2 InvislMount Warranties And Certifications Part of Superior System The InvisiMount product was specifically envisioned and Component Built for use with SunPower DC and AC modules Uplift 664lbf 25-year product warranty engineered to air with SunPower modules.The resultingMid clamp Warranties • Best-in-class system reliability and aesthetics g p Shear 5401bf • 5-year finish warranty Optional rooftop transition flashing,rail- system-level approach amplifies the aesthetic and End clamp Uplift 899lbf UL2703 Listed mounted J-box,and wire management rail clips Shear 220lbf Certifications g p installation benefits for homeowners and for installers. Moment:upward 54SIbf-ft Class A Fire Rated Combine with SunPower modules and Rail SunPower EnergyLlnk®monitoring app Moment:downward 580 lbf-ft Rail splice Moment:upward 548 Ibf-ft Moment:downward 580 Ibf-ft o "chment Hardware Warranties Uplift 1000 lbf sunpower.com L-foot Shear 3901bf Refer to roof attachment hardware manufacturer's documentation. Awo •_ E U 'Module frame that is compatible with the InvisiMount s1stem required for hardware intemperability. U, L 'SunPower recommends that all Equinox-,InAsiMount,and AC module systems always be designed using the InvisiMount Span Tables#524734.If a designer decides to instead use the component capacities listed In this document to design a system,note that the capacities shown are Load and Resistance Factor Design(LRFD)design loads,and are NOT to be used for Allowable Stress Design(ASD)calculations;and that a licensed Professional Engineer(PE)must then stamp all calculations.Ifyou have any questions please contact SunPower Technical Support at 1-855-977-7867. SunpOWer.COm ©2018 SunPower Corporation.All Rights Reserved.SUNPOWER,the SUNPOWER logo,EQUINOX and INVISIMOUNT are trademarks or registered trademarks of Sun Power Corporation. 509506 RevF All other trademarks are the property of their respective owners.Specifications included in this datasheet are subject to change without notice. Datasheet D. PEGASUS ABETTER DAY ON THE JOB COMP MOUNT - BLACK SOLAR- 1.Drill pilot hole in - 2.Optional:Apply a center of rafter. "U-shape"of sealant • MOUNTMP to underside of flashing and postition under 2nd shingle course,cone over pilot hole. Simple 3-piece design 3.Place L-Foot over 4.Drive lag to required for rapid installation cone and install lag depth.Attach rail per with washer through rail manufacturer's v L-Foot. instructions. Encapsulating design raises the water seal 9 0" 0.9" above roof deck 1.5" 3.5' 3.5" Q n n 0.9" 11.6" � 2.3" 2.3" 2.4" One-piece flashing with elevated cone—No press-fits or deck-level EPDM washers to fail Specifications Black Camp Mount Install Kits SKU PSCR-CO PSCR-UBBO SPCR-CH WATERTIGHT FOR LIFE L-Foot Type Closed Slot Open Slot Closed Slot Pegasus Solar's Comp Mount is a cost effective,high-quality option for rail installations on composition shingle roofs. L-Foot,Flashing, L-Foot,Kit Contents 5/16"x 4-1/2"SS Lag 5/16"x 4-1/2"SS Lag Flashing, 5/16"x 4-1/2"SS Lag L-Foot,Flashing, Designed to last decades,the one-piece flashing with elevated cone means there is simply nothing to fail. w/EPDM washer w/EPDM washer w/EPDM washer,M10 Hex Bolt Finish Black L-Foot and Black Flashing 25-year Warranty Superior Waterproofing Roof Type Composition Shingle 60 Manufactured with advanced materials and Tested to AC286 without sealant v Certifications IBC,ASCE/SEI 7-10,AC286 Af�k coating to outlast the roof itself 1 Install Application Railed Systems Compatible Rail Most Flashing Material Painted Galvalume Plus L-Foot Material Aluminum • Code Compliant 1 • ne Kit Packaging Kit Quantity 24 VExceeds Compliant•'1 40 -included in each Boxes per Pallet 72 Patents Pending.All rights reserved.©2019 Pegasus Solar Inc 100 West Ohio Avenue,Richmond,CA 94804 1 1100 West Ohio Avenue,Richmond,CA 94804 - T-510.730.1343 pe.eaton.com pe.eaton.com Eaton general duty cartridge Eaton general duty non-fusible fuse safety switch safety switch e DG222NRB DG222URB UPC:782113144221 UPC:782113144238 Dimensions: Dimensions: • Height: 14.37 IN • Height: 14.38 IN • Length: 7.35 IN • Length: 7.38 IN •Width: 8.4 IN •Width: 8.69 IN Weight:10 LB Weight:9 LB Notes:Maximum hp ratings apply only when dual Notes:WARNING! Switch is not approved for element fuses are used. 3-Phase hp rating shown is service entrance unless a neutral kit is installed. a grounded B phase rating, UL listed. Warranties: Warranties: Eaton Selling Policy 25-000, one(1)year from • Eaton Selling Policy 25-000, one(1)year from the date of installation of the Product or the date of installation of the Product or eighteen (18)months from the date of shipment eighteen (18)months from the date of shipment of the Product,whichever occurs first. of the Product,whichever occurs first. Specifications: Specifications: • Type: Non-fusible, single-throw • Type: General duty, cartridge fused •Amperage Rating: 60A •Amperage Rating: 60A • Enclosure: NEMA 3R, Rainproof • Enclosure: NEMA 3R • Enclosure Material: Painted galvanized steel • Enclosure Material: Painted galvanized steel • Fuse Configuration: Non-fusible • Fuse Class Provision: Class H fuses • Number Of Poles: Two-pole • Fuse Configuration: Fusible with neutral • Number Of Wires: Two-wire • Number Of Poles: Two-pole • Product Category: General duty safety switch • Number Of Wires: Three-wire •Voltage Rating: 240V • Product Category: General duty safety switch •Voltage Rating: 240V Supporting documents: • Eatons Volume 2-Commercial Distribution Supporting documents: • Eaton Specification Sheet- DG222URB • Eatons Volume 2-Commercial Distribution Certifications: • Eaton Specification Sheet- DG222NRB • UL Listed Certifications: Product compliance: No Data • UL Listed Product compliance: No Data pe.eaton.com pe.eaton.com Eaton CH main lug loadcenter Eaton CH main lug loadcenter CH8L125RP CH12L125R UPC:782114190548 UPC:782113097381 Dimensions: Dimensions: • Height: 3.69 IN • Height: 5.19 IN • Length: 13 IN • Length: 16.75 IN •Width: 11 IN •Width: 14.31 IN Weight:12 LB Weight:15.8 LB Notes:Ground bar kits priced separately. Suitable Notes:Suitable for use as service equipment when for use as service equipment when not more than not more than six service disconnecting mains are two service disconnecting mains are provided or provided or when not used as a lighting and when not used as a lighting and appliance appliance panelboard. Rainproof panels are panelboard. furnished with hub closure plates. For rainproof Warranties: hubs. • Limited lifetime Warranties: Specifications: • Limited lifetime • Special Features: Cover included Specifications: • Type: Main lug only • Special Features: Cover included •Amperage Rating: 125A • Type: Main lug only • Box Size: 7r •Amperage Rating: 125A • Bus Material: Copper • Box Size: B • Enclosure: NEMA 3R • Bus Material: Copper • Enclosure Material: Metallic • Enclosure: NEMA 3R • Feed Type: Overhead • Enclosure Material: Metallic • Main Circuit Breaker: CH • Feed Type: Overhead • Number Of Circuits: 8 • Main Circuit Breaker: CH • Number Of Wires: Three-wire • Number Of Circuits: 12 • Phase: Single-phase • Number Of Wires: Three-wire •Voltage Rating: 120/240V, 208Y/120,240V • Phase: Single-phase •Wire Size:#6-1/0 AWG •Voltage Rating: 120/240V Supporting documents: •Wire Size:#6-2/0 AWG •Type CH Circuit Breakers and Loadcenters Supporting documents: • Loadcenters and Circuit Breakers • Dimensional Drawing-CH 3/4 LOADCENTER, • Eatons Volume 1-Residential and Light MAIN LUG ONLY, OUTDOOR NEMA 3R, Commercial 120/240 VAC, 1 PH 0.180" 0.350" o Lid(Side View) Box(Side View) o 6 3/4" 7 3/8" o 0 6 7/16" o Lid(Top View) 6 3/4" 0 0 0 6 7116" 6" 6.. o R 114 UL Listed Marine Listed 0.220" R3/16 Gasket(Top View) UL File#E205935(QCUP) Box(Top View) UL Control#92CM Material is Rigid PVC o 1/8" 132 cu in Volume(2163 cu cm) Screws are Zinc Plated Steel Gasket(Side View) Gasket is neoprene CAAVTKK #8 by 1/2" INC UPort Worth,TEW ® L Junction Box 6 x 6 x 4 Drawn By:O.M. Date:6/19/17 5133710 � � -� i I I I I c,����,i��'F/*sti, 1 � 1 ' i i i I I I �� I -fl - , - - -- � � � -r � - `_ _ ,� _ _ � �' - � r ` .� _ w �!e►. _�� _ �� -- — � —_— _. r z�_ _ - � r�r1 a� rSj - ___—��O � 7 lL/S�.a �c a � T� �— i �-` 11 :�! r � - I�� � `• �• _ � . }.ter.. '4 .. . r _ass - -