Loading...
Item 10 - Plans SHEETINDEX PV-1 PLOT PLAN o PEE OF 7F UT PV 3 ATOTACHMENLAR OT DETAILS w*�• 9*C�QO MYO GROUP * * Q PV-4 ELECTRICAL LINE DIAGRAM ........................... BENNETf A. FORD pl........................ NOTES: p�••, �109875 ��o -SYSTEM FOLLOWS ANY/ALL FIRE CODE 1 �Ooo�0000 PROJECT NAME: SETBACKS PER ORDINANCES OF THE PLAINVIEW ENGINEERING LLC SOUTLAKE. TX FIRM#20680 8-18-2020 -ALL PROJECTS WILL COMPLY WITH THE ORDINANCES OF THE SOUTLAKE. STRUCTURAL ONLY RAMANA VENIGALLA -PRODUCT DATA SHEETS WILL BE RESIDENCE INCLUDED. -ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE AREA OF ARRAY: 393.6 SQ. FT. 821 LAKE CARILLON LN SOUTLAKE,TX 76092 ESID#: 1044372000 0324613 SCOPE OF WORK I z z INSTALL A 6.820 kW GRID-TIED PHOTOVOLTAIC SYSTEM TOTALING (22) JURISDICTION: MISSION SOLAR MSE310SQ8T SOLAR U SOUTLAKE MODULES WITH (1)SOLAREDGE SE6000H-US w DRAWING NOTES: INVERTER,FLUSH MOUNTED ON A Q PHOTOVOLTAIC SOLAR MODULE COMPOSITE SHINGLE ROOF AND / J MFG/MODEL: MISSION SOLAR MSE310SQ8T INTERCONNECTED VIA MAIN LOAD CENTER. MODULE RATED AT: 310 W MULTIPLY BY QTY.OF MODULES: 22 0 0 0 I ARRAY SYSTEM SIZE: 6.820 kW CODE COMPLIANCE MEW SYSTEM AZIMUTH: 180' ALL SUPPLIED EQUIPMENT IS UL LISTED ROOF PITCH: 8:12 2017 NATIONAL ELECTRIC CODE 0 0 MOUNTING HEIGHT: 1 -STORY 2018 INTERNATIONAL RESIDENTIAL CODE ORIENTATION OPTIONS ARE PRELIMINARY,AND 2018 INTERNATIONAL BUILDING CODE MAIN LOAD CENTER& ARE SUBJECT TO REVISION FOR OPTIMAL USE. 2018 INTERNATIONAL FIRE CODE VISIBLE,LOCKABLE, UTILITY METER LABELED AC DISCONNECT SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION,FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE,AND SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. ARCHITECT/FIELD DRAWING INFORMATION REV DESCRIPTION DATE PLAN Pv_ 1 PLOTPLAN DRAWN BY: TK A SCALE: 1 20'-O" DRAWN DATE: 817120 SOLAR MODULE:MECHANICAL DATA PANELS: (22)MISSION SOLAR MSE310SQ8T OF MODULE DIMENSIONS: 65.51"x 39.33"x 1.56" ,o MODULE WEIGHT: 40.1 Ibs OF MODULE SQUARE FOOTAGE: 17.89 sq ft 7f�P••s9*000 M YO GROUP MODULE WEIGHT/MODULE AREA: 2.74 lb/sq.ft. • O SOLAR ARRAY:MECHANICAL DATA .k .......... . .* OD WEIGHT OF ARRAY: 882.21bs. BENNETT A. FORD � J'........................ O AREA OF ARRAY: 393.6 sq R. ^ ARRAY DEAD LOAD WILL NOT �^ <109875 `Q- EXCEED: 4.0 lb/sq ft. V ARRAY DEAD LOAD: 2.74 lb/sq ft. No.ATTACHMENTS: 30S' ( •.e•" s\�p CONNECTOR TYPE: 5116"X 3.5"S.S.LAG SCREW(2.5"MIN EMBEDMENT) \ - GNAL p PROJECT NAME: �4�O0004o PLAINVIEW ENGINEERING LLC TX FIRM#20680 8-18-2020 STRUCTURAL ONLY RAMANA VENIGALLA RESIDENCE Z J Z O 821 LAKE CARILLON LN J SOUTLAKE,TX 76092 ESID#: 1044372000 0324613 Q U LU Y Q JURISDICTION: J SOUTLAKE DRAWING NOTES: PHOTOVOLTAIC SOLAR MODULE MFG/MODEL: MISSION SOLAR MSE310SQ8T MODULE RATED AT: 310 W v MULTIPLY BY QTY.OF MODULES: 22 ARRAY SYSTEM SIZE: 6.820 kW SYSTEM AZIMUTH: 180' 0 ROOF PITCH: $:12 MOUNTING HEIGHT: 1 -STORY ORIENTATION OPTIONS ARE PRELIMINARY,AND io ARE SUBJECT TO REVISION FOR OPTIMAL USE. SOLAR ARRAY LOCATIONS ARE TO BE REVIEWED AND APPROVED BY OWNER AND/OR ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION,FOR VENTILATION OBSTRUCTION . O O AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS. FIELD VERIFICATION OF ROOF STRUCTURE,AND 8'-6" 36'�" SOLAR ARRAY LOCATION IS REQUIRED PRIOR (E)MAIN LOAD CENTER, TO INSTALLATION FOR ALL EXISTING INSIDE GARAGE STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. (N)IRONRIDGE ATTACHMENTS @ (N)SOLAREDGE SE6000H-US (E)UTILITY METER ARCHITECT/FIELD DRAWING INFORMATION 72"MAX.SPAN INVERTER REV DESCRIPTION DATE 'VISIBLE,LOCKABLE,LABELED (22)MISSION SOLAR AC DISCONNECT TO BE MSE310SQ8T SOLAR (N)VISIBLE,LOCKABLE, LOCATED WITHIN 1O'OF PLAN MODULES LABELED AC DISCONNECT UTILITY METER PV-2 SOLAR LAYOUT DRAWN BY: TK SCALE:3/32"=1'-0" DRAWN DATE: 817120 LABELS ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE,WILL BE INSTALLED AS REQUIRED. PHOTOVOLTAIC MODULE SPECIFICATIONS NEC 690.31(1)-AT THE INVERTER ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC,ENGRAVED OR MACHINE PRINTED MODEL: MISSION SOLAR MSE310SQ8T M YO GROUP LETTERS IN A CONTRASTING COLOR TO THE PLAQUE.THIS PLAQUE WILL BE ATTACHED BY POP RIVETS OR SCREWS WARNING OR OTHER APPROVED METHOD.IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT. WEIGHT: 40.1 LBS THE DISCONNECT OF THE GROUNDED WIDTH: 39.33" CONDUCTORS)MAY RESULT IN PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METAL CONDUIT AND THE OVERVQLTAGE ON THE EQUIPMENT CONDUIT SHALL BE LABELED,"CAUTION DC CIRCUIT'OR EQUIVALENT EVERY 5 FT. LENGTH: 65.51 NEC 690.13(B)-ON AC DISCONNECT/BREAKER/POINTS OF CONNECTION. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES,EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. MAX.ROOF LOAD: 2.69 LBS/SQFT AC PHOTOVOLTAIC DISCONNECT EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION POINT IDENTIFIED ON THE MODULE AND MAX.POINT LOAD: 35.97 LBS/ATTACHMENT NEC 690.13(B)-AT JUNCTION BOXICOMBINER BOXES/BREAKER THE MANUFACTURER'S INSTRUCTIONS. PANEL/POLE BOXES/AC DISCONNECTS/MAIN SERVICE DISCONNECT: IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING,IT PROJECT NAME: 'IS THE CONTRACTORS RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. WARNING ooaoopppp ELECTRICAL SHOCK HAZARDDONOTTOUG TERMINALS ALL SOLAR MODULES,EQUIPMENT AND METALLIC COMPONENTS ARE TO BE BONDED. ` O TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED 9 00 IN THE OPEN POSITION Q�*•°° 1/�A�{� S* O NEC 110.27(C)-ATJUNCTION BOX/COMBINER BOXES/BREAKER a•••••••••••••••••••••••••••� BANANA VENIGALLA PANEL/POLE BOXES/AC DISCONNECTS/MAIN SERVICE DISCONNECT: 0 BENNETT A. FORD WARNING .......................: :�� RESIDENCE TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 690.54-ON AC DISCONNECT/BREAKER/ POINT OF INTERCONNECTION/BREAKER PANEL/PULL BOXES OppOoOo��� PHOTOVOLTAIC SYSTEM PLAINVIEW ENGINEERING LLC AC SYSTEM SPECIFICATIONS TX FIRM#20680 M 821 LAKE CARILLON LN OPERATING VOLTAGE V A IRONRIDGE 8-18-2020 SOUTLAKE,TX 76092 NEC 690.52-ON AC DISCONNECT/BREAKER/POINT OF CONNECTION: ES D#: 1044372000 0324613 FLASHFOOT STRUCTURAL ONLY OPERATINGAC VOLTAGE: V OPERATINGAC FREQUENCY_ Hz MAXIMUM AC POWER_ KW MAXIMUM AC CURRENT_ A IRONRIDGE L-FOOT MAXIMUM OCPD RATING: A JURISDICTION: NEC 705.12(B)(2)(c)-BY BREAKER AT DISTRIBUTION SOUTLAKE EQUIPMENT: COMP. SHINGLE DRAWING NOTES: WARNING PHOTOVOLTAIC SOLAR MODULE POWER SOURCE OUTPUT CONNECTION. MFG/MODEL: MISSION SOLAR MSE310SQ8T DO NOT RELOCATE THIS SOLAR MODULE OVERCURRENT DEVICE MODULE RATED AT: 310 W NEC 690.13(F)-AT MAIN SERVICE DISCONNECT: IRONRIDGE MULTIPLY BY QTY.OF MODULES: 22 CAUTION MOUNTING CLAMP 6.820 kW W ARRAY SYSTEM SIZE: PHOTOVOLTAIC p�.p SYSTEM IS BACKFED W SYSTEM AZIMUTH: 18V 2X6 RAFTER ROOF PITCH: 8:12 NEC 690.31(G)(3)(4)-ON CONDUIT 24"OC TYP MOUNTING HEIGHT: 1 -STORY WARNING PHOTOVOLTAIC IRONRIDGE W/PLYWOOD ORIENTATION OPTIONS ARE PRELIMINARY,AND POWER SOURCE 18 XR 100 RAIL, ARE SUBJECT TO REVISION FOR OPTIMAL USE. NEC 705.12(D)(3),NEC 690.59-PRODUCTION/NET METER TYP. SOLAR ARRAY LOCATIONS ARE TO BE (BI-DIRECITIONAL)/MAIN SERVICE DISCONNECT REVIEWED AND APPROVED BY OWNER AND/OR WARNING DUAL POWER SOURCE 12 ARCHITECT OF RECORD TO VERIFY SYSTEM LOCATION,FOR VENTILATION OBSTRUCTION SECOND SOURCE IS PHOTOVOLTAIC SYSTEM 5/16"x 3 1/2"SS LAG BOLT AND POSSIBLE RELOCATION OF VENT AND/OR PIPE JACKS.2 1/2"MIN. . NEC 690.31(B)-AT MAIN SERVICE DISCONNECT/UTILITY METER INTO RAFTER(S) FIELD VERIFICATION OF ROOF STRUCTURE,AND MAIN PHOTOVOLTAIC EMBEDMENT SEALED SOLAR ARRAY LOCATION IS REQUIRED PRIOR W/G E O C E L. TO INSTALLATION FOR ALL EXISTING SYSTEM DISCONNECT STRUCTURES WHERE NEW SOLAR ARRAYS ARE TO BE INSTALLED. NEC 690.15(C)&690.33(E)(2)-AT MAIN SERVICE DISCONNECT DO NOT DISCONNECT IRONRIDGE L-FOOT W/ FLASHFOOT MOUNTING SYSTEM ARCHITECT/FIELD DRAWING INFORMATION UNDER LOAD I REV DESCRIPTION DATE SCALE: 1"=V-0" PLAN PLAQUES SHALL BE PLASTIC ENGRAVED IN A CONTRASTING PV-3 COLOR TO THE PLAQUE.PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR ADHESIVE. DRAWN BY: TK DRAWN DATE: 8(//20 jorl�, 11161� Calculations for Current Carrying Conductors: Mission Solar MSE310SQ8T No. of Modules-Branch 1 :6*�F UL1703 No. of Modules -Branch 2 Max Branch required DC conductor ampacity MYO GROUP Power 310 W Number of Modules (3410W)/(380V)(1.25)=11.2A 40.12 Voc, 33.17 Vmp,20 Vnom Record low temp 9.761sc 9.345 Im • AWG#10,derated ampacity: Max AC Output Current 25A (40)(0.71)(1)=28.4A 600 V, UL E42728, Operating AC Voltage 240 V NEMA 3,4,4x,6,12,13 Operating AC Power 6114 W 28.4A> 11.2,therefore DC wire size is valid. Operating AC Frequency 60 Hz PROJECT NAME SolarEd eSE6000H-US[Sli] Max OCPD Rating 35A AC required conductor ampacity UL 1741,NEMA 311, IEEE 1547 (25)(1.25)=31.25A Nom Output Voltage 240V SolarEdge P340 Max Output Current 25A Vmpp 380VDC, Imax 15A AWG#8,derated ampacity: UL1741, IEC62109-1, NEMA6P (55)(0.%)(1)=52.8A RAMANA VENIGALLA UL 1741, NEMA 3R RESIDENCE 60 A,240 V, NON-FUSIBLE 52.8A>31.25A,therefore AC wire size is valid. 821 LAKE CARILLON LN SOUTLAKE,TX 76092 ESID#: 1044372000 0324613 SOLAR MODULE/INVERTER MANUFACTURER AND QUANTITY: (22)MISSION SOLAR MSE310SQ8T SOLAR MODULES *VISIBLE,LOCKABLE, (1)SOLAREDGE SE6000H-US INVERTER LABELED AC DISCONNECT TO BE LOCATED WITHIN 10'OF BI-DIRECTIONAL JURISDICTION: UTILITY METER UTILITY METER SOUTLAKE 1 PHASE,3 WIRE DRAWING NOTES: 120/240 V PHOTOVOLTAIC SOLAR MODULE MFG/MODEL: MISSION SOLAR MSE310SQ8T LI l2 N MODULE RATED AT: 310 W MULTIPLY BY QTY.OF MODULES: 22 PHOTOVOLTAIC ARRAY PV BREAKER 40 A DPB 200 A ARRAY SYSTEM SIZE: 6.820 kW BRANCH CIRCUIT 1=11 MODULES LOCATED FARTHEST MAIN DISCONNECT SYSTEM AZIMUTH: 18(f DC-DC FROM MSD POWER INVERTER(240V) EXISTING ROOF PITCH: 8:12 OPTIMZER ••• _ &INTEGRATED 200 A RATED DC DISCONNECT 60A VISIBLE, MAIN SERVICE MOUNTING HEIGHT: 1 -STORY JUNCTION LOCKABLE, PANEL ORIENTATION OPTIONS ARE PRELIMINARY,AND BOX W/INTERNAL GFDI&AFCI LABELED ~ ARE SUBJECT TO REVISION FOR OPTIMAL USE. AC DISCONNECT SOLAR ARRAY LOCATIONS ARE TO BE LL L1 REVIEWED AND APPROVED BY OWNER AND/OR ••• - �� ARCHITECT OF RECORD TO VERIFY SYSTEM LZ 12 LOCATION,FOR VENTILATION OBSTRUCTION AND POSSIBLE RELOCATION OF VENT AND/OR N N PIPE JACKS. BRANCH CIRCUIT 2=11 MODULES / G G FIELD VERIFICATION OF ROOF STRUCTURE,AND G G SOLAR ARRAY LOCATION IS REQUIRED PRIOR TO INSTALLATION FOR ALL EXISTING EGC STRUCTURES WHERE NEW SOLAR ARRAYS ARE THWN-2 IN TO BE INSTALLED. 3/4"EMT NEW,IF NO AWG#10 THWN-2 IN AWG#8 EXISTING ARCHITECT/FIELD DRAWING INFORMATION PV WIRE IN FREE AIR 3/4"EMT L1 =BLACK GROUNDING REV DESCRIPTION DATE POS=RED AWG#10 L2=RED ELECTRODE NEG=BLACK POS=RED N=WHITE AWG#6 NEG=BLACK AWG#8 PLAN G=BARE CU AWG#8 G=GREEN PV-4 G=GREEN DRAWN BY: TK DRAWN DATE: 8/7/20 IRONRIDGE Roof Mount System Built for solar's toughest roofs. IronRidge builds the strongest roof mounting system in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior ® Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating r1w Design Software Certified to maintain the fire resistance Online tool generates a complete bill of rating of the existing roof. materials in minutes. Integrated Grounding 20 Year Warranty ® UL 2703 system eliminates separate Twice the protection offered by module grounding components. competitors. XR Rails XR10 Rail XR100 Rail XR1000 Rail Internal Splices i 771111 A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability 8'spanning capability 12'spanning capability Self-tapping screws • Moderate load capability Heavy load capability Extreme load capability Varying versions for rails • Clear& black anod. finish Clear& black anod. finish Clear anodized finish Grounding Straps offered Attachments FlashFoot Slotted L-Feet Standoffs Tilt Legs 4W = i Anchor, flash, and mount Drop-in design for rapid rail Raise flush or tilted Tilt assembly to desired with all-in-one attachments. attachment. systems to various heights. angle, up to 45 degrees. • Ships with all hardware High-friction serrated face Works with vent flashing Attaches directly to rail • IBC & IRC compliant Heavy-duty profile shape Ships pre-assembled Ships with all hardware • Certified with XR Rails Clear& black anod. finish 4" and 7" Lengths Fixed and adjustable Clamps & Grounding - End Clamps Grounding Mid Clamps T Bolt Grounding Lugs Accessories Jk j= 4� 3 Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish & black anod. Parallel bonding T-bolt Easy top-slot mounting Snap-in Wire Clips • Sizes from 1.22"to 2.3" Reusable up to 10 times Eliminates pre-drilling Perfected End Caps • Optional Under Clamps Mill & black stainless Swivels in any direction UV-protected polymer Free Resources LlGo esign Assistant ♦ NABCEP Certified Training from rough layout to fully �� Earn free continuing education credits, ngineered system. For free. A A, while learning more about our systems. o to IronRidge.com/rm `t' Go to IronRidge.com/training 0 2014 IronRidge, _ _ _ _ :00 A& OOCERTIFIED RELIABILITY >Tested to UL1703& IEC standards > PID resistant ADVANCED TECHNOLOGY >PERC and 5 busbar drive >19.2% module efficiency > Ideal for residential applications EXTREME WEATHER RESILIENCE >5631 Pa front and back load (117 psf)tested load to UL1703 BAA COMPLIANT FOR GOVERNMENT PROJECTS > Buy American Act >American Recovery&Reinvestment Act MODULES TM ASSEMBLED 25-YEAR" ' All ENGINEERED FRAME-TO-FRAME WARRANTYTM 315 - 325W 100% - Mission Solar Energy Warranty 90.7% CLASS LEADING POWER OUTPUT 90% 80.2% 0 80% 19 . 24 Yo 70% MAXIMUM EFFICIENCY 1 5 10 15 20 25 YEARS O ~ 1- 3 % CERTIFICATIONS IEC 61215- IEC 61730- IEC 61701 - UL 1703-Salt mist POSITIVE POWER TOLERANCE C 8,LISTED OS C E C46 LI nN High-Power, American Quality Please contact Mission Solar Energy if you have questions or concerns about certification Mission Solar Energy is headquartered in San Antonio,TX.,with of our products in your area. module production facilities on-site.We produce American quality solar *Standard 12-year product warranty extendable to 25 years with registration: modules ensuring the highest power output and reliability to our https://www.missionsolar.com/warranty/ customers.Our product line is well suited for residential,commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations,proving excellent . VIA performance over the long-term. , MISSION SOLAR www.missionsolar.com I info@missionsolar.com ENERGY • DOCUMENT#.C-SA2-MKTG-0018 REVISION#.R1 REVISION DATE:1/13/2020 PERC 60 CLASS LEADING 315-325W SPECIFICATIONSELECTRICAL • Electrical Parameters at Standard Test Conditions(STC) Module Type MSE315SR8T MSE320SR8T MSE325SR8T IEC Power Output Pmax Wp 315 320 325 61215-61730-61701 -Salt mist Module Efficiency % 18.65 18.94 19.24 UL Tolerance 0-+3% 0-+3% 0-+3% UL 1703 listed Short-Circuit Current Isc A 9.997 10.028 10.060 Open Circuit Voltage Voc V 40.44 40.80 41.14 O CEC c us Rated Current Imp A 9.253 9.351 9.387 LISTED Rated Voltage Vmp V 34.04 34.22 34.62 Fuse Rating 20 20 20 COEFFICIENTSTEMPERATURE MSE320SR8T: 320WP,60 CELL SOLAR MODULE Normal Operating Cell Temperature(NOCT) 46.09°C(±2°C) CURRENT-VOLTAGE CURVE Temperature Coefficient of Pmax -0.377%/'C 12 Temperature Coefficient of Voc -0.280%/'C Cells Temp. =25°C Temperature Coefficient of Isc 0.039%/'C 10 Incident Irrd.=1000 W/m2 OPERATING CONDITIONS Q 8 Incident Irrd.=800 W/m2 Y 1= 6 Incident Irrd.=600 W/m2 Maximum System Voltage 1,000Vdc ' U Operating Temperature Range -40oC(-40oF)to+85°C(185°F) 4 Incident Irrd.=400 W/m2 Maximum Series Fuse Rating 20A Incident Irrd.=200 W/m2 z Fire Safety Classification Type 1,Class C Front&Back Load(UL standard) 5631 Pa(117 psf) 0 Tested to UL1703 standard 0 to 20 30 40 Hail Safety Impact Velocity 25mm at 23 m/s Voltage[V] Current-voltage characteristics with dependence on irradiance MECHANICALand module temperature Solar Cells P-type mono-crystalline silicon (158.75mm) Cell Orientation 60 cells(6x10),5 busbar BASIC DESIGN (UNITS: mm) Module Dimension 1676mm x 1008mm x 40mm 1008 (65.98 in.x 39.68 in.x 1.58 in.) Weight 20 kg(441b) 35 35 Front Glass 3.2mm(0.126 in.)tempered, 00 low-iron,anti-reflective coating le o00 Frame Anodized aluminum alloy 77 838 Encapsulant Ethylene vinyl acetate(EVA) Mounting Hole J-Box Protection class IP67 with 3 bypass-diodes 1676 1676 Cables PV wire, 1 m(39.37 in.),4mm2/12 AWG Grounding Hole Connector MC4 Compatible 838 5 SHIPPING INFORMATION Container FT Pallets Panels 320 W loos 53' Double stack 36 936 299.52 kW Front View Back View 40' Double stack 28 728 232.96 kW Panels Weight Height Width Length =� M Pallet 26 1,198lbs 42.45" 45.50" 67.00" MISSION SOLAR ENERGY ' Mission Solar Energy reserves the right to make specification changes without notice Mission Solar Energy 18303 S.New Braunfels Ave.,San Antonio,Texas 78235 DOCUMENT#:C-SA2-MKTG-0018 REVISION#:R1 REVISION DATE:1/13/2020 info@missionsolar.com I www.missionsolar.com PV1 PLAI NVI EW ENGINEERING August 18,2020 Re: Rooftop Solar PV System 821 Lake Carillon Lane Southlake,TX 76092 To Whom It May Concern: I have reviewed the structural plans(sheets PV-2&PV-3,drawn by MYO Group,dated 8/7/2020)for the roof-mounted solar PV(photovoltaic)system at the above-referenced address.The proposed solar array comprises(22)new flush-mounted PV panels.The structure to which the PV system will be attached is a wood-framed,single-family residence with a composition shingle,hip-style roof.The roof framing system generally consists of 2x6 SPF rafters spaced at 24"OC. This residence is categorized as a Risk Category I1 structure under the definitions provided in ASCE 7-10.Wind and snow design parameters for this project are as follows: • Basic Wind Speed(3 second gust): 115 MPH • Exposure Category:B • Ground Snow Load: 5 PSF The proposed solar panels will be affixed to the roof using components manufactured by IronRidge Corporation. Specifically, the roof attachments shall be IronRidge Flashfoot2 anchors and shall utilize a 5/16"diameter lag bolt with sufficient length to provide 2.5"of embedment into the rafters. Spanning between the attachments shall be IronRidge XR100 rail,which shall be oriented perpendicular to the rafters. Span limit shall be 72"and attachment points shall be staggered such that the attachments are evenly distributed among the rafters.Rail cantilever shall not exceed 18".All structural racking components shall be installed and torqued according to IronRidge's installation instructions using manufacturer-supplied hardware. Modules shall be top-clamped within the clamping range specified by the module manufacturer.The total distributed load of the PV array(including panels,racking,attachments,and wiring)shall not exceed 3 lb/SF. The structural design(racking,roof attachments)of this proposed solar PV system,as described above,conforms to the 2018 IRC,as adopted by the city of Southlake,TX. Solar PV arrays,since they consist of tightly-spaced glass panels,effectively prevent coincident application of live loads.I have analyzed the roof load combinations for the proposed PV array in accordance with Section R324.4.1 of the IRC. My conclusion is that the roof is capable of resisting the additional loads that will be imparted by the proposed PV system. Please do not hesitate to contact me should you have any questions about the design of this roof-mounted PV array. Respectfully, Bennett A Ford,P.E.(TX#109875) oo�� OF�4F4��� Qao* * 0� •°°°°BENNETT•A.°FORD°°°••� OP�`• 109875 °ODOOvov�� PLAINVIEW ENGINEERING LLC TX FIRM»20680 8/18/2020 Plainview Engineering LLC Texas Registered Engineering Firm#F-20680 Phone: 512.785.4179