Item 8 - Demonstration and PlansMASTER SIGN PLAN APPLICATION 1400 Main Street, Suite 310, Southlake, TX 76092 Phone: (817) 748-8069 Fax: (817) 748-8077 Website: www.cityofsouthlake.com Revised January 2023 2 8.2 APPLICATION PROCESS 8.2.1 The applicant shall develop a master sign plan for all sign elements in the development based on the sign design guidelines established in Section 8.4. 8.2.2 The Administrative Official shall forward the applicant’s Master Sign Plan to the City Council for action on the application after evaluating the Master Sign Plan on the established design guidelines. The City Council shall make the final determination on the Master Sign Plan. 8.2.3 After approval of a Master Sign Plan for a particular development, all signs in that development shall meet the standards approved in that specific Master Sign Plan. A complete sign package includes the following: 8.3 APPLIC ATION REQUIREMENTS A Master Sign Plan Application shall be a written and/or illustrated document to depict the proposed signs which shall include: 8.3.1 Proposed sign palette which may include: a.Attached Building Signs b.Monument Signs c.Window Signs d.Directional Signs/Wayfinding e.Directory Signs f.Pedestrian Oriented Signs g. Other 8.3.2 Location of all proposed signs included in the sign palette 8.3.3 Size and number of all proposed signs including maximum area, letter height, number, height, etc. 8.3.4 Materials proposed for all signs and sign structures. 8.3.5 Color and style palette for all signs (letter colors, background colors, text fonts, etc.) including context of where signs are to be placed on any given façade. 8.3.6 Type of illumination proposed (external, internal, etc.) 8.3.7 Landscaping and/or ornamental structures including fences, fountains, public art, ground cover, and other landscaping elements that are intended to complement the proposed sign palette and design. 8.3.8 Any other information as required by the decision making bodies. 8.4 DESIGN GUIDELINES- MASTER SIGN PLANS Commercial signage is an integral part of the urban design fabric of Southlake. It is absolutely necessary and shall be deemed as a tool that helps promote the health, safety and welfare of the general public by providing guidance to both the vehicular driver and pedestrian. Due to its visual prominence and effect on the overall design character of our city, signage as part of master sign plans must be considered on the broader scale of community rather than on an individual site basis. Signage is an integral part of the visual urban streetscape and shall not be designed to visually compete with its surroundings, but rather serve to build on the quality of the traveler’s and pedestrian’s experience. The basis for submitting a master sign plan application should not be to have larger signs or logos permitted by ordinance but should clearly be related to the sign design goals listed below: MASTER SIGN PLAN APPLICATION 1400 Main Street, Suite 310, Southlake, TX 76092 Phone: (817) 748-8069 Fax: (817) 748-8077 Website: www.cityofsouthlake.com Revised January 2023 3 Design Goals 1)To develop an organized hierarchy of signage design types that help identify the location and size standards for individual signs without infringing on the capability of creative design. 2)To establish design criteria that promote the overall visual quality of the streetscape environment for the general public while providing reasonable and improved standards for identification of individual properties. 3)To improve the overall visual cohesive appearance of the site through signage guidelines, with strong consideration that the visual streetscape. 4)To promote a “sense of place” for the City of Southlake while promoting creative design for individual developments. 5)To promote signage as an architectural complement rather than being visually and thematically disconnected. Master Signage Plan Application The master signage program application shall include, at a minimum, the following to be deemed a completed application: 1)A master site plan showing a location of each of the proposed signage type(s). Dimension and label the sign types and include distance measurement of the signs location from the nearest public right-of way. 2)Provide signage elevations (dimensioned and labeled) indicating proposed text areas, materials, material finishes, colors, lighting and identifiable references as to how the signage design relates to the proposed architecture. Identify any landscaping elements proposed. 3)For all signage is to be mounted on building façades, provide accurate building elevations that show signage dimension, signage location, text areas, materials, material finishes, colors and identifiable references as to how the signage design relates to the proposed architecture. 4)If the applicant is requesting any variances from the current regulations as part of the master sign plan, please indicate the location of the variance, what the variance request is for and specific reason/justification for the variance and how the variance promotes are adheres to the design goals provided. 5)A master sign plan application will be considered by the City Council following a recommendation by the Sign Board. The Sign Board’s recommendation will be forwarded to the City Council for their consideration. The sign design guidelines are designed to help ensure quality signs that communicate their message in a clear fashion; however, the “guidelines” are not as strict as sign “standards.” The review authority may interpret the design guidelines with some flexibility in their application to specific signs/projects, as not all design criteria may be workable or appropriate for each sign or project. In some circumstances, one guideline may be relaxed to facilitate compliance with another guideline determined by the review authority to be more important in the particular case. The overall objective is to ensure that the intent and spirit of the design guidelines are followed. Narrative GRANITE SOUTHLAKE OFFICE 2 Date Issued: November 24, 2025 Regarding: Sign Variance Application To: Dennis Killough, AICP Deputy Director – Planning and Development Services City of Southlake, Texas 1400 Main Street, Suite 310 Southlake, Texas 76092 From: Anita Delgado SIGN VARIANCE APPLICATION We are seeking approval of a variance to amend the Granite Place Two Master Sign Plan to allow an additional top-of-building sign on the north elevation. This elevation was not included in the sign areas previously approved by City Council under the original Master Sign Plan adopted in December 2021 or subsequent amendments. The request is driven by a new tenant, Ryan LLC, whose visibility requirements include identification toward Highway 114. The north elevation is the only building orientation that provides meaningful visibility to that corridor. Allowing a sign in this location supports effective tenant identification while maintaining consistency with the scale, placement, and character of signage previously approved for Granite Place Two. The proposed sign will remain within the upper-story sign band dimensions and letter-height standards established through prior amendments and Sign Ordinance 704. The accompanying exhibits update the approved elevations and site plan to include this north elevation sign while keeping all other conditions of the Granite Place Two Master Sign Plan unchanged. We appreciate the City’s consideration of this request and are available to answer any questions. Sincerely, Anita Delgado, AIA LEED AP BD+C Vice President – Corgan 2 9 9' B-B 327' B-B419' B-B120'-0" 480'-0" VISIBILITY TRIANGLE 480'-0" VISIBILITY TRIANGLE 120'-0" 480'-0"VISIBILITY TRIANGLE 120'-0"FVS I G N S I G N S I G N A01-12 01 A01-12 06 Sim GRANITE PLACE OFFICE 2 GRANITE PLACE OFFICE 1 D I V I S I O N S T R E E TSTATE STREETTRANSFORMER; REF. ELECT.KNOX BOX FDC DUMPSTER ENCLOSURE EXISTING PARKING 5 LEVEL GARAGE FIRE PUMP ROOM FIRE COMMAND CENTER NEW PARKING ADDITION 5 LEVEL GARAGE KNOX BOX KNOX BOX GENERATOR 8" BURNISHED BLOCK SCREENWALL (7'-4" TALL) FULLY GROUTED CELLS RESERVE STREETKNOX BOX DATE JOB SHEET ISSUES REVISIONS A01-01 SITE PLAN SOUTHLAKE OFFICE 202/18/22 601 STATE STREET, SOUTHLAKE, TX 76092CORGAN 401 N. Houston St Dallas, TX 75202 T: 214-748-2000 2 1 10/25/2021 DESIGN DEVELOPMENT 3 4 5 6 7 8 9 10 1" = 30'-0"1 SITE PLAN PLAN NN 1 1 CANOPIES / SUN SHADING DEVICES C-1 ALUMINUM COMPOSITE CANOPY MT-1 METAL PANEL CANOPY SYSTEM EXTERIOR BUILDING MATERIALS MP-1 METAL PANEL ACM-1 INSULATED ALUMINUM COMPOSITE METAL PANEL MS-1 METAL SCREEN WITH PERFORATED METAL PANEL C-1 ARCHITECTURALLY EXPOSED CONCRETE PC-1 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 1 PC-2 INSULATED PRE-CAST CONCRETE WITH INTEGRAL COLOR PC-3 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 2 PC-4 PRE-CAST CONCRETE WITH INLAID BRICK PC-5 PRE-CAST CONCRETE; PAINTED TO MATCH EXISTING CW ALUMINUM CURTAIN WALL SYSTEM WW ALUMINUM WINDOW WALL GL-1 INSULATED VISION GLASS GL-2 INSULATED SPANDREL GLASS GL-3 INSULATED VISION GLASS MATERIALS LEGEND 1 2 3 4 5 GL-1 PC-3GL-3 CW MP-1 WW 01 A06-02 02 A06-02 03 A06-02 C-1PC-2 GL-1GL-1PC-2 PC-2 M2 M2 M2 M2 N3 N2N2N2N2N2N2N4 U3 U1 U1 U1 U1 U1 U1 U1U1U1U1U1U1U3 M3 U3 U1 U1 U1 U1 U1 U1 LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" 123456 T.O.P. 182' -6" PENTHOUSE 192' -0" CW MP-1 C-1 PC-1 CW GL-2GL-1 PC-3 01 A06-02 02 A06-02 03 A06-02 4' - 6" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 17' - 4" GL-2 PC-2GL-1 28' - 0"64' - 0"92' - 0"PC-2GL-3 A B3 B B B DF J2 J2 J2 J1 J1 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 G J2 6.1 10 11 10 9 8 7 01 A06-01 02 A06-01 J2 J2 J1 J1 J1 J2 J1 J2 J1 J2 J1 J1J2J1J2 J2J1 J1 J2J1 J1 K C1 C C C D HL LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" 1110987 T.O.P. 182' -6" PENTHOUSE 192' -0" 01 A06-01 02 A06-01 4' - 6" 4' - 0" 9' - 4" 0' - 8" 14' - 0" 14' - 0" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 7' - 4" 10' - 0"92' - 0"9' - 6"82' - 6"U U1 U1 U1 U1 U1 U2 U2U1U1U1U1U1U U U1 U1 U1 U1 U1 U2 M1 N5 N2 N2 N2 N2 N2 N1 10 10 DATE JOB SHEET ISSUES KEYPLAN REVISIONS 8/29/2022 10:45:17 AMA05-01 EXTERIOR ELEVATIONS - OFFICE SOUTHLAKE OFFICE 202/18/22 21415.0000 07.27.2022 A05-01EXTERIOR ELEVATIONS -OFFICE601 STATE STREET, SOUTHLAKE, TX 76092CORGAN 401 N. Houston St Dallas, TX 75202 T: 214-748-2000 2 02/18/2022 50% CONSTRUCTION DOCS 1 10/25/2021 DESIGN DEVELOPMENT 3 03/11/2022 ISSUE FOR PERMIT 4 5/2/2022 ISSUE FOR CONSTRUCTION 5 6 7 8 9 10 P O 3/32" = 1'-0"01 NORTH ELEVATION 3/32" = 1'-0"02 SOUTH ELEVATION 10 08/29/2022 PCR 04