Loading...
ZBA25-0016 - 4021 Hilltop Drive - SEU PUBLIC HEARING NOTICE ZBA25-0016 Dear Property Owner: A request for a Special Exception Use has been filed with the Board of Adjustment of the City of Southlake. The purpose of the hearing is to consider a request for a Special Exception Use per Zoning Ordinance No. 480, as amended, Section 44.12(6), for a reduction in the required setback from the property line for a residential accessory structure on property described as Lot 14, Hilltop Acres Addition, and located at 4021 Hilltop Drive. Current Zoning: “SF-1A” Single Family Residential District The purpose of this request is to seek approval of a Special Exception Use to reduce the required setback to a minimum of 10 feet for a 1,124 square foot detached carport. If you wish to register your views on the matter, you may complete and send the enclosed Notification Response Form to the Planning & Development Services Department. You are encouraged to follow the requested action through final approval because changes are often made during the review process. Please note that this letter and its attachments constitute written notice about the proposed Special Exception Uses. Please contact the Planning and Development Services Department if you have any questions at (817) 748-8621. CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817) 748-8621 www.cityofsouthlake.com Zoning Board of Adjustment Thursday, December 11, 2025 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZBA25-0016: Special Exception Use for 4021 Hilltop Drive Meeting Date: December 11, 2025 Fill out: Owner: _____________________________ Address: ____________________________ City, State, Zip Code: __________________ PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed application referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s). Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone : (817) 748-8621 XXXI/we (the undersigned) have reviewed this planand approve it as correct within reasonabletolerance. I/we understand that any changesmade to a shape or to a location may delay theproject and/or result in additional cost. Anycommunicated timeline by the project manager isan estimate, and is subject to change based offweather changes, material availability, and otherREVISIONSBUILDER:TEXAS BEST FENCEADDRESS:4021 HILLTOP DRCITY:SOUTHLAKEZIP:76092PHONE:903-875-9630EMAILBRITTNEEB@OUTLOOK.COMTEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERPROJECT MANAGER:DATE REVIEWED:4021 HILLTOP DR, SOUTHLAKE TX, 76092 COVERED CARPORT W/ METAL ROOF EXISTING DRIVE WAY CONCRETE EXISTING BASKETBALL HOOOP TO BE REMOVED 12" OVERHANG FROM BEAM ON 3 SIDES (3) WALL LIGHT FIXTURES SET ON POSTS (X) (8) LV CAN LIGHTS RECESSED (L) (3) FANS (F) (6) 8"x8"x1/4 HSS STEEL POST (2)14"x24"I-BEAM 6"x6"HSS BEAM6"x6"HSS BEAM 2X8 WOOD 2X8 WOOD 300W INTERMATIC TRANSFORMER FOR OUTDOOR LIGHTS/FAN AND SWITCH ON POST 2X8 WOOD FOR SUPORT 2X8 WOOD FOR SUPORT 12" OVERHANG 10" METAL DRIP EDGE ZIPOSBZIP BOARD OR 5/8TH OSB METAL ROOF 5/8TH OSB ON ROOF T&G CELING 2X8 WOOD FOR SUPORT 6"x6"HSS BEAM (2)4"x4"HSS 45* BRACKET EXISITNG WOOD FENCE NEW PATIO COVER: CANTILEVER STEEEL STRUCTURE WITH TONGUE AND GROOVE CEDAR CEILING NEW PATIO COVER: 312 SQFT CANTILEVER STEEEL STRUCTURE WITH TONGUE AND GROOVE CEDAR CEILING EXISTING CONCRETE WALKWAY EXISTING STONE RETAINING WALL HOUSE NORTH16'24' 20' 1'1'12'1'9' 10"30' 4"33' 6"33' 6" 29' 6" P L L L L LL L X X X L F F F P I-BEAM6"x6"X1/4" HSS6"x6"X1/4" HSS6"x6"X1/4" HSS6"x6"X1/4" HSS(2) 6"x6"X1/4" HSS6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS I-BEAMP P PP 24'8'XXXI/we (the undersigned) have reviewed this plan andapprove it as correct within reasonable tolerance.I/we understand that any changes made to a shapeor to a location may delay the project and/or resultin additional cost. Any communicated timeline bythe project manager is an estimate, and is subject tochange based off weather changes, materialavailability, and other conditions.REVISIONSDATE REVIEWED:PROJECT MANAGER:TEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERBUILDER:TEXAS BEST FENCEADDRESS:4021 HILLTOP DRCITY:SOUTHLAKEZIP:76092PHONE:903-875-9630EMAILBRITTNEEB@OUTLOOK.COMPROJECT NOTES: 1/12 INCLINE 4"x4" SUPPORT CONCRETE (6) 8"x8"x1/4 HSS STEEL POST 8"x8" POST FOOTER 2" VENEER 2" VENEER (2)14"x24"I-BEAM HSS 8"x8"x1/4" STEEL COLUMN 14" #4 DOWEL TO PREVENT UPLIFT PIER NOTES: 1. 3000 PSI CONCRETE, 60 KSI STEEL 2. NO SPLICING OF STEEL ALOWED 3. PIER EMBEDDED 12" MIN INTO UNDISTURBED SOIL 4. POSITIVE DRAINAGE AWAY FROM PIERS 48" 20" (3) #4 OCEW BOTTOM OF PIER WITH (8) #4 VERTICALS EACH CORNER AND (3) STIRRUPS 6"x6"HSS BEAM 6"x6"HSS BEAM5' 9"33' 6" 29' 6"2'12' 16'1'1'1' 1'1' 24'10'8'12'4' 10"7' 3"3' 8"4' 8"3' 8"XXXI/we (the undersigned) have reviewed this plan andapprove it as correct within reasonable tolerance.I/we understand that any changes made to a shapeor to a location may delay the project and/or resultin additional cost. Any communicated timeline bythe project manager is an estimate, and is subject tochange based off weather changes, materialREVISIONSDATE REVIEWED:PROJECT MANAGER:TEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERBUILDER:TEXAS BEST FENCEADDRESS:4021 HILLTOP DRCITY:SOUTHLAKEZIP:76092PHONE:903-875-9630EMAILBRITTNEEB@OUTLOOK.COMPROJECT NOTES: XXXI/we (the undersigned) have reviewed this plan andapprove it as correct within reasonable tolerance.I/we understand that any changes made to a shapeor to a location may delay the project and/or resultin additional cost. Any communicated timeline bythe project manager is an estimate, and is subject tochange based off weather changes, materialavailability, and other conditions.REVISIONSEMAILBRITTNEEB@OUTLOOK.COMPHONE:903-875-9630ZIP:76092CITY:SOUTHLAKEADDRESS:4021 HILLTOP DRBUILDER:TEXAS BEST FENCETEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERPROJECT MANAGER:DATE REVIEWED:4021 HILLTOP DR, SOUTHLAKE TX, 76092 COVERED CARPORT W/ METAL ROOF T&G CELING 2X8 WOOD SUPPORTS AT 24" O.C. 6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS 6"x6"X1/4" HSS R: 0" P L L L L LL L X X X L F F F P 14" X 24" WIDE FLANGE I-BEAM6"x6"X1/4" HSS6"x6"X1/4" HSS6"x6"X1/4" HSS6"x6"X1/4" HSS(2) 6"x6"X1/4" HSS6"x6"X1/4" HSS 6"x6"X1/4" HSS 8"x8"X1/4" HSS STEEL POSTS W/ 2" VENEER 6"x6"X1/4" HSS 6"x6"X1/4" HSS 14" X 24" WIDE FLANGE I-BEAMP P PP 8' 6"EXISTING DRIVE WAY CONCRETE EXISTING BASKETBALL HOOOP TO BE REMOVED 12" OVERHANG FROM BEAM ON 3 SIDES (3) WALL LIGHT FIXTURES SET ON POSTS (X) (8) LV CAN LIGHTS RECESSED (L) (3) FANS (F) (6) 8"x8"x1/4 HSS STEEL POST W/ 2" VENEER (2)14"x24" WIDE FLANGE I-BEAM 300W INTERMATIC TRANSFORMER FOR OUTDOOR LIGHTS/FAN AND SWITCH ON POST 12" OVERHANG 10" METAL DRIP EDGE ZIPOSBZIP BOARD OR 5/8TH OSB METAL ROOF 5/8TH OSB ON ROOF T&G CELING 2X8 WOOD SUPPORTS AT 24" O.C. 6"x6"HSS BEAM (2)4"x4"HSS 45* BRACKET EXISITNG WOOD FENCE NEW PATIO COVER: CANTILEVER STEEEL STRUCTURE WITH TONGUE AND GROOVE CEDAR CEILING NEW PATIO COVER: 312 SQFT CANTILEVER STEEEL STRUCTURE WITH TONGUE AND GROOVE CEDAR CEILING EXISTING CONCRETE WALKWAY EXISTING STONE RETAINING WALL HOUSE NORTH 16'24' 20' 1'1'12'1'9'30' 4"33' 6"XXXI/we (the undersigned) have reviewed this plan andapprove it as correct within reasonable tolerance.I/we understand that any changes made to a shapeor to a location may delay the project and/or resultin additional cost. Any communicated timeline bythe project manager is an estimate, and is subject tochange based off weather changes, materialavailability, and other conditions.REVISIONSEMAILBRITTNEEB@OUTLOOK.COMPHONE:903-875-9630ZIP:76092CITY:SOUTHLAKEADDRESS:4021 HILLTOP DRBUILDER:TEXAS BEST FENCETEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERPROJECT MANAGER:DATE REVIEWED:PROJECT NOTES: 24'10'8' 6"12'4' 10"7' 3"3' 8"4' 8"3' 8"7' 2"6'12'6' 2"7' 2"7' 2"6' 2"1/12 INCLINE 4"x4" SUPPORT 1/12 INCLINE CONCRETE CONCRETE (6) 8"x8"x1/4 HSS STEEL POST 8"x8"x1/4" HSS POST 8"x8"x1/4" HSS POST FOOTER FOOTER 2" VENEER 2" VENEER 10'8'2" VENEERGFCI ELECTRIC OUTLET TO BE SET ON OUTSIDE OF POST VENEER (2)14"x24"I-BEAM HSS 8"x8"x1/4" STEEL COLUMN 14" #4 DOWEL TO PREVENT UPLIFT PIER NOTES: 48" 1. 3000 PSI CONCRETE, 60 KSI STEEL 2. NO SPLICING OF STEEL ALOWED 3. PIER EMBEDDED 12" MIN INTO UNDISTURBED SOIL 4. POSITIVE DRAINAGE AWAY FROM PIERS 20" (3) #4 OCEW BOTTOM OF PIER WITH (8) #4 VERTICALS EACH CORNER AND (3) STIRRUPS 2"X8" WOOD SUPPORTS 2X8 WOOD SUPPORTS AT 24" O.C. 5/8TH OSB ROOFING TOPPED WITH CHOICE METAL SHIM & WELD WIDE FLANGE I-BEAM TO HSS BEAM 5' 9"33' 6"2'12' 8" 1'1' 6"x6"HSS BEAM 6"x6"HSS BEAM 6"x6"HSS BEAM 6"x6"HSS BEAM 14"X24" WIDE FLANGE I-BEAM 14"X24" WIDE FLANGE I-BEAM 30' 2" 20' 14"X24" WIDE FLANGE I-BEAM REAR 14"X24" WIDE FLANGE I-BEAM REAR 6"x6"HSS BEAM1'1' 2"X8" WOOD 6"x6"HSS BEAM 6"x6"HSS BEAM FACIA FACIA OSB ROOFING TOPPED WITH CHOICE METAL OSB ROOFING TOPPED WITH CHOICE METAL 5' 8"6'7' 2"6"x6"HSS BEAM 6"x6"HSS BEAM 2"X8" WOOD SUPPORTS XXXI/we (the undersigned) have reviewed this plan andapprove it as correct within reasonable tolerance.I/we understand that any changes made to a shapeor to a location may delay the project and/or resultin additional cost. Any communicated timeline bythe project manager is an estimate, and is subject tochange based off weather changes, materialREVISIONSEMAILBRITTNEEB@OUTLOOK.COMPHONE:903-875-9630ZIP:76092CITY:SOUTHLAKEADDRESS:4021 HILLTOP DRBUILDER:TEXAS BEST FENCETEXAS BEST FENCE & PATIOCUSTOM CARPORT - PATIO COVERPROJECT MANAGER:DATE REVIEWED:PROJECT NOTES: NEW CARPORT STRUCTURE PROPOSED ALLOWABLE VARIANCE BLDG. LINE PROPOSED ALLOWABLE VARIANCE BLDG. LINE 10' 13'5"