Loading...
ZA25-0069-SP-185 S White Chapel Blvd PUBLIC HEARING NOTICE ZA25-0069 • Site Plan for White Chapel Methodist Church, on property described at Lot 1R, Block 1, White Chapel Methodist Church Addition, and located at 185 S White Chapel Blvd. • Current Zoning: “CS” Community Service District. • The primary purpose of this request is to seek approval for a new 2-story 9,942 square-foot resource building. Dear Property Owner, Your property has been identified as being within 300 feet of the above referenced Site Plan application. If you wish to register your opposition or support to this case, you may complete the attached Notification Response Form and either mail to the Planning & Development Services Department (address listed at the top of notice) or email (e-mail listed at the bottom of the notice). You are encouraged to follow the requested action through final approval because changes are often made during the review process. Please contact the Planning and Development Services Department if you have any questions: Please contact the Planning Department at (817)748-8621 or mburnett@ci.southlake.tx.us if you have any questions. Thank you. CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817)748-8621 www.cityofsouthlake.com Planning and Zoning Commission Thursday, November 20, 2025 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZA25-0069: Site Plan for White Chapel Methodist Church Meeting Date: November 20, 2025 Fill out: Owner: _____________________________ Address: ____________________________ City, State, Zip Code: __________________ PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Zoning Change and Site Plan referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s). Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817) 748-8621 Fax : (817) 748-8077 WHI T E CHA P E L BLV D NORTHWOOD CTLONDONBERRY T E R NORTHWOOD TRLPEARL DR WHITECHAPEL BLVDWHITE CHAPEL BLVDSOUTHLAKE BLVD OLIVIA CTPINE DR4 10 1412 1516 20 22 25 24 30 32 31 29 5 13 23 19 17 18 28 27 26 8 2 1 3 9 76 21 11 1000 SPO Map ZA25-0069 ® 0 350 700175 Feet 185 S White Chapel Blvd Legend City Parcels Right Of Way City Limit Case Parcel(s) dissolvedParcel 200 Foot Buffer 300 Foot Buffer Parcels Within Buffer rowClip bufferCut WHITES CHAPEL UNITED METHODIST CHURCH COVER SHEET A0.00 CASE :ZA25-0069 PROJECT ADDRESS CITY STATE ZIP 185 S. WHITE'S CHAPEL BLVD. SOUTHLAKE TX 76092 JOB NO.25009 DATE ISSUE FOR DRAWN BY 2025.10.23 REVIEW MCS WHITE'S CHAPEL RESOURCE CENTER ARCHITECTURE ▪ PLANNING ▪ INTERIORS 1921 STATE HWY 121 ▪ SUITE 250 LEWISVILLE ▪ TX 75056 972 ▪ 331 ▪ 5699 SCHEMATIC DESIGN, FEASIBILITY STUDY, OR PRELIMINARY BUDGETING THIS DOCUMENT IS INCOMPLETE AND MAY NOT BE USED FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION. (TBAE - EFFECTIVE 10-01-2003) COPYRIGHT OF DESIGN WITHHELD BY KLINE HARDIN UNLESS NOTED OTHERWISE. ARCHITECT: STATE: REGISTRATION NO. DATE: BRENT E. KLINE 10976 TX 2025.10.29 ARCHITECT OF RECORD SEAL TO BE INSERTED ZA25-0069 SHEET INDEX SP1 SITE PLAN A4.01 EXTERIOR ELEVATIONS A4.02 EXTERIOR ELEVATIONS Development DataExistingProposed ChangesNew TotalZoningCSCSCSLand Use DesignationPublic/Semi PublicPublic/Semi PublicPublic/Semi PublicGross Acreage23.28 acres23.28 acres23.28 acresNet Acerage23.28 acres23.28 acres23.28 acresNo. of Lots111Percentage of Site Coverage13.73%13.99%13.99%Area of Open Space - Sq. Ft.419,577424,058424,058Percentage of Open Space41.38%41.82%41.82%Impervious Coverage Area - Sq. Ft.594,500590,019590,019Impervious Coverage Percentage58.62%58.18%58.18%Start of ConstructionFirst Quarter of 2026First Quarter of 2026First Quarter of 2026Completion of ConstructionLast Quarter of 2026Last Quarter of 2026Last Quarter of 2026Building Area Footprint - Sq. Ft.139,213141,884141,884No. of Stories222Max. Building Height37 Ft.37 Ft.37 Ft.Proposed Floor Area - Sq. Ft.189,215195,707195,707Floor Area by UseClassroom Bldg. E26,9136,9136,913Classroom Bldg. E311,93411,93411,934Worship Space10,20010,20010,200(500 Seats)(500 Seats)(500 Seats)Fellowship Hall9,7889,7889,788Sanctuary Building44,52344,52344,523(2,000 Seats)(2,000 Seats)(2,000 Seats)Administration4,7354,7354,735Prayer Chapel214214214Accessory Buildings5,7795,7795,779Classroom Bldg. A11,19211,19211,192Classroom Bldg. B20,54720,54720,547Wedding Chapel1,5161,5161,516Fellowship Addition3,5083,5083,508Administration Building18,93618,93618,936Fellowship Hall Addition35,98035,98035,980Existing Resource Cntr (Brick House)3,4500New Resource (Classroom) Center9,9429,942Outside Stotage0%00Required Parking667667667Parking Provided on Church Lot991974974Standard Parking962945945HC Parking292929Parking Provided on Adjacent lot viaaccess and parking agreement withneighbor166166166Total parking provided1,1571,1401,140PROJECTADDRESSCITYSTATEZIP185 S. WHITE'S CHAPEL BLVD.SOUTHLAKETX76092JOB NO.25009DATEISSUE FORDRAWN BY2025.10.23REVIEWMCSWHITE'S CHAPELRESOURCE CENTERARCHITECTURE ▪ PLANNING ▪ INTERIORS1921 STATE HWY 121 ▪ SUITE 250LEWISVILLE ▪ TX 75056972 ▪ 331 ▪ 5699SCHEMATICDESIGN,FEASIBILITYSTUDY,OR PRELIMINARYBUDGETINGTHIS DOCUMENT IS INCOMPLETE ANDMAY NOT BE USED FOR REGULATORYAPPROVAL, PERMITTING, ORCONSTRUCTION.(TBAE - EFFECTIVE 10-01-2003)COPYRIGHT OF DESIGN WITHHELD BYKLINE HARDIN UNLESS NOTEDOTHERWISE.ARCHITECT:STATE:REGISTRATION NO.DATE:BRENT E. KLINE10976TX2025.10.29ARCHITECT OF RECORD SEAL TO BEINSERTEDSITEPLANSP1ZA25-0069 100'-0"FLOOR SLAB 107'-2"T.O.FRAME 128'-6"T.O.PARAPET 123'-0"T.O.FRAME 100'-0"FLOOR SLAB 102'-6"WATER TABLE 109'-0"T.O.FRAME 123'-0"T.O.FRAME 141'-5 1/2"APPROX. HT. 116'-6"B.O.FRAME 134'-3"APPROX. HT. 129'-6"BOTTOM 100'-0"FLOOR SLAB 102'-6"WATER TABLE 128'-6"T.O.PARAPET 123'-0"T.O.FRAME 109'-0"T.O.FRAME 116'-6"B.O.FRAME 141'-5 1/2"APPROX. HT. 134'-3"APPROX. HT. 512 CJ 139'-0 1/4"RIDGE ( APPROX.) PROJECT ADDRESS CITY STATE ZIP 185 S. WHITE'S CHAPEL BLVD. SOUTHLAKE TX 76092 JOB NO.25009 DATE ISSUE FOR DRAWN BY 2025.10.23 REVIEW MCS WHITE'S CHAPEL RESOURCE CENTER ARCHITECTURE ▪ PLANNING ▪ INTERIORS 1921 STATE HWY 121 ▪ SUITE 250 LEWISVILLE ▪ TX 75056 972 ▪ 331 ▪ 5699 SCHEMATIC DESIGN, FEASIBILITY STUDY, OR PRELIMINARY BUDGETING THIS DOCUMENT IS INCOMPLETE AND MAY NOT BE USED FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION. (TBAE - EFFECTIVE 10-01-2003) COPYRIGHT OF DESIGN WITHHELD BY KLINE HARDIN UNLESS NOTED OTHERWISE. ARCHITECT: STATE: REGISTRATION NO. DATE: BRENT E. KLINE 10976 TX 2025.10.29 ARCHITECT OF RECORD SEAL TO BE INSERTED BUILDING ELEVATIONS A4.01 SCALE: EAST ELEVATION21/8" = 1'-0"SCALE: SOUTH ELEVATION11/8" = 1'-0" SCALE: KEY PLAN3NTS 1 2ZA25-0069 100'-0"FLOOR SLAB 102'-6"WATER TABLE 109'-0"T.O.FRAME 123'-0"T.O.FRAME 141'-5 1/2"APPROX. HT. 116'-6"B.O.FRAME 128'-6"T.O.PARAPET 128'-6"T.O.PARAPET 100'-0"FLOOR SLAB 102'-6"WATER TABLE 109'-0"T.O.FRAME 123'-0"T.O.FRAME 139'-0 1/4"RIDGE ( APPROX.) 141'-5 1/2"APPROX. HT. 116'-6"B.O.FRAME 134'-3"APPROX. HT. 129'-6"BOTTOM 134'-3"APPROX. HT.512 129'-6"BOTTOM 102'-6"B.O.FRAME PROJECT ADDRESS CITY STATE ZIP 185 S. WHITE'S CHAPEL BLVD. SOUTHLAKE TX 76092 JOB NO.25009 DATE ISSUE FOR DRAWN BY 2025.10.23 REVIEW MCS WHITE'S CHAPEL RESOURCE CENTER ARCHITECTURE ▪ PLANNING ▪ INTERIORS 1921 STATE HWY 121 ▪ SUITE 250 LEWISVILLE ▪ TX 75056 972 ▪ 331 ▪ 5699 SCHEMATIC DESIGN, FEASIBILITY STUDY, OR PRELIMINARY BUDGETING THIS DOCUMENT IS INCOMPLETE AND MAY NOT BE USED FOR REGULATORY APPROVAL, PERMITTING, OR CONSTRUCTION. (TBAE - EFFECTIVE 10-01-2003) COPYRIGHT OF DESIGN WITHHELD BY KLINE HARDIN UNLESS NOTED OTHERWISE. ARCHITECT: STATE: REGISTRATION NO. DATE: BRENT E. KLINE 10976 TX 2025.10.29 ARCHITECT OF RECORD SEAL TO BE INSERTED BUILDING ELEVATIONS A4.02SCALE: KEY PLAN4NTS 1 3SCALE: WEST ELEVATION31/8" = 1'-0" SCALE: NORTH ELEVATION11/8" = 1'-0" ZA25-0069 SCALE: ARCH ELEVATIONS21/4" = 1'-0"10'-3 5/8"17'-7 7/8"14'-8 3/8" 1'-0" 1'-0" NOTE: 1 OF 4 ARCHES.