Loading...
Item 7 - Site PlanFLFLF LFLFLFLFLFLFL F L 8"W 8"W 8"W G G OH E OH E OH E OH E E OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE OHE OHE OHE OHEOHEOHEOHEOHEOHEOHE O H E OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHEOHEOHEOHEOHEN89°28'39"E 1663.12' S0°18'41"E 1274.60' S89°41'16"W 903.45' ∆=12°47'37" R=1889.86' L=421.99' CB=N44°40'29"W C=421.11' ∆=18°48'30" R=2658.52' L=872.71' CB=N28°52'26"W C=868.79' N5°38'33"W 83.69' N19°28'10"W 128.15' EX. 44' ROW DEDICATION BY CARILLON PARC PHASE 1A LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 PORTION OF A CALLED 55.300 ACRES SOUTHLAKE DOVE ASSOCIATES, LLC DOC. NO. D215094206 O.P.R.T.C.T. PARCEL ID NO. 41248848 CALLED 1.82 ACRES PANORAMA PROPERTIES, LTD. DOC. NO. D206290483 O.P.R.T.C.T. BLOCK A THRASHER ADDITION CAB. 388-202, PG. 73 P.R.T.C.T. CARILLON PHASE 1A INST.NO. D211101073 P.R.T.C.T. 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 931 D.R.T.C.T. CITY OF SOUTHLAKE UTILITY EASEMENT VOL. 8405, PG. 1444 D.R.T.C.T. 15' DRAINAGE EASEMENT DOC. NO. D221095079 O.P.R.T.C.T. 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. WATER LINE EASEMENT INST. NO. D211236610 O.P.R.T.C.T. BLOCK 4 METAIRIE AT SOUTHLAKE INST. NO. D221095079 O.P.R.T.C.T. BLOCK 1 PARKWAY OFFICES CENTER ADDITION CAB. 388-184, SL. 71 P.R.T.C.T. PART OF LOT 1 PART OF LOT 2 PART OF LOT 3 CALLED 42.5091 CARILLON CROWN, LLC INST.NO. DOC. NO. D222154040 O.P.R.T.C.T. BLDG 9 BLDG 2 FLFLFL FLFLFLFL F L F L F L F L FL FL FLFLFLFLFLFLFLFLFLFL FL FL FL FLFLFLFLFL F L F L F L F L FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL ///// / ///// /FLFLFLFLFLFL FL FL FLFLFL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FLFLFLFLFLFL FL FLFLFLFLFLFLEV EV EV EV W STATE HWY 1 1 4 E KIRKWOOD BLVD N WHITE CHAPEL BLVDLOT 2, BLOCK A 9.509 ACRES 414,231 SF LOT 3, BLOCK A 9.350 ACRES 407,266 SF LOT 1, BLOCK A 2.996 ACRES 130,492 SF LOT 3, BLOCK A 9.350 ACRES 407,266 SF BLDG 4BLDG 1 BLDG 5 BLDG 3 BLDG 6 BLDG 7 BLDG 8 BLDG 10 BLDG 11 BLDG12 BLDG 13 99' ROW50' ROW50' ROW100' ROW50' ROW 50' ROW55' HALF ROW DEDICATION 100' RO W 45' HALF ROW DEDICATION 430' E X. R O W 6 1 5 4 1 7 2 3 50' ROW This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED8/21/2025 2:16 PMPLOTTED BYBORAWSKI, ALINA 8/21/2025 2:16 PMDWG PATHK:\DAL_CIVIL\067545015-TRADEMARK SOUTHLAKE\CAD\PHASE 1\PLANSHEETSDWG NAMEC-SITE-PLAN OVERALL.DWG , [ OVERALL SITE PLAN ]IMAGES EPSG2276_Date20250115_Lat32.965999_Lon-97.153911_Mpp0.300_Vert :XREFS xArch : xBase : xBndry : xEsmt : xExBase : xExUtil : xHardscape : xLabel : xPlant : xStrm : xUtil : x24X36 : xRoundabout : xSingleFamily : xEsmt-Commerical : xbndy : xHatch : xSite-South : xPave-WC : xHard© 2025 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL RD. TWO GALLERIA OFFICE TOWERSUITE 700 DALLAS, TX 752408/21/2025CITY OF SOUTHLAKE, TXTRADEMARK SOUTHLAKE067545015AGBQEKCMDOVERALL SITE PLANC-100 SITE PLAN FOR CITY REVIEW ONLY TO ILLUSTRATE COMPLIANCE WITH ZONING AND DEVELOPMENTS REGULATIONS. IT IS NOT INTENDED FOR CONSTRUCTION PURPOSES. C-104C-103 C-101 C-102 NORTH 1.ALL SIGNAGE IS APPROVED VIA SEPARATE PERMITTING PROCESS. 2.PARKING SPACE RETURN RADII ARE 3' OR 10' UNLESS OTHERWISE NOTED. 3.DUMPSTER ENCLOSURES SHOULD NOT BE SEEN FROM THE PUBLIC RIGHT-OF-WAY. SCREENING OF THE DUMPSTERS SHALL BE OF THE SAME MASONRY MATERIAL AS THE PRIMARY STRUCTURE AND BE A MINIMUM OF EIGHT (8) FEET IN HEIGHT. SOLID METAL GATES SHALL BE AFFIXED TO THE OPENING AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN BEING SERVICED. 4.ALL LIGHT SOURCES, INCLUDING WALL PACKS, SHALL BE FULL CUT-OFFS (I.E. RECESSED/SHIELDED). 5.ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE SUFFICIENTLY SCREENED FROM VIEW BY PARAPET WALLS, AND GROUND MOUNTED EQUIPMENT SHALL BE SCREENED BY MASONRY WING WALLS THAT MATCH THE MATERIAL OF THE PRIMARY BUILDING OR ADEQUATE LANDSCAPING. 6.NO OVERHEAD UTILITIES ARE PERMITTED ON THE SUBJECT PROPERTY. 7.ALL PARKING SPACES TO BE 9’ X18'. 8.ALL STRIPING IN PARKING LOTS SHALL BE WHITE. 9.HANDICAPPED ACCESS RAMPS SHALL BE PAINTED OR CONSTRUCTED OF CONTRASTING COLORS FROM THE STANDARD PAVEMENT BUT SHALL NOT BE IN COLORS THAT ARE CONSIDERED BRIGHT, NEON, OR GARISH. 10.FIRE APPARATUS ACCESS ROADS TO BE AN ALL-WEATHER SURFACE, ASPHALT OR CONCRETE, 24 FEET WIDE AND ABLE TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS. (MINIMUM OF 85,000 POUNDS GVW). CITY SITE PLAN NOTES NORTH ENGINEER / SURVEYOR / APPLICANT / LANDSCAPE ARCHITECT / IRRIGATOR: KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL ROAD, TWO GALLERIA OFFICE TOWER, SUITE 700, DALLAS, TX. 75240 PHONE: (469) 914-8611 CONTACT: PEYTON MCGEE, P.E. 40.20 ACRES JAMES J. WEST SURVEY, ABSTRACT NO. 1620 CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS SUBMITTED AUGUST 21, 2025 OWNER: SHIVERS FAMILY PARTNERSHIP 1800 N WHITE CHAPEL BLVD SOUTHLAKE, TX 76092-3617 CONTACT: REBECCA UTLEY ARCHITECT: DWELL DESIGN STUDIO CONTACT: RYAN MILLER PHONE: (770) 864-1035 EMAIL: RMILLER@DWELLDESIGNSTUDIO.COM SITE PLAN TRADEMARK SOUTHLAKE CITY CASE NO. ZA25-0045 DEVELOPER: TRADEMARK PROPERTY COMPANY 1701 RIVER RUN #500 FORTH WORTH, TX 76107 CONTACT: BLAKE BICKMORE EMAIL: BBICKMORE@TRADEMARKPROPERTY.COM (TYP.) X LEGEND EX S JB PROPERTY LINE PROPOSED FIRE LANE PROPOSED FIRE HYDRANT PROPOSED CURB INLET PROPOSED FDC/WATER METER PROPOSED SANITARY SEWER MANHOLE PROPOSED GRATE INLET PROPOSED JUNCTION BOX PROPOSED RETAINING WALL ACCESSIBLE PARKING SYMBOL NUMBER OF PARKING SPACES PROPOSED BUILDING ENTRANCE TYPICAL EXISTING PROPOSED LIGHT DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT PUBLIC CONCRETE PAVEMENT FH CI WM PROP. GI JB FDC VICINITY MAP (NOT TO SCALE) VICINITY MAP 10' 40' 40' S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W 8"W8"W S S S S S S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W 8"W8"W S S S S SWOHEOHEOHE OHE OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOH E OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHEOHEN89°28'39"E 1663.12' ∆=18°48'30" R=2658.52' L=872.71' CB=N28°52'26"W C=868.79' N5°38'33"W 83.69' N19°28'10"W 128.15'FLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLF L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLEV EV EV EV CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE LOT 1 BUILDING 4 GROCER SINGLE-STORY - 44'-0" HT 33,798 SF BUILDING 1* BUILDING 5 RETAIL SINGLE-STORY 29'-6" HT 18,551 SF BUILDING 3 RESTAURANT SINGLE-STORY 24' HT 3,914 SF BUILDING 6 RESTAURANT SINGLE-STORY BUILDING 7 RESTAURANT SINGLE-STORY 27' HT 7,500 SF JB PORTION OF A CALLED 55.300 ACRES SOUTHLAKE DOVE ASSOCIATES, LLC DOC. NO. D215094206 O.P.R.T.C.T. PARCEL ID NO. 41248848 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 931 D.R.T.C.T. 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. 6 10 14 14 19 22 4 12 13 22 22 22 22 22 22 20 9 13 13 13 9 9 13 11 25 7 20 6 25 5 7 31 14 9 11 13 9 21 38' 10' BUFFERYARD PROPOSED 4 ' RETAINING WALL FOR DETENTION POND PROPOSED DRIVEWAY PROPOSED DRIVEWAY 247' 68'78'13'13'E K IRKWOOD BLVD STRE E T A18'24'18'18'18'24'11'26'18'18'18'24'18'18'24'10'18'18'24'18'24'18'18'18'24'18'18'24'18'24'18'18'18'24'18'30'18' 19'225' 153' 84' 61' 62'110' 75'57' 50' 50'30' FH FH FH FH FH FH FH FH FH FH JB JB JB JB JB JB JB 18'24'18' PROPOSED DETENTION POND 24' 6' 18' 24' 9' 18'50' BU ILD ING SETBACK60' 62' 69' SOUTHLAKE DOVE ASSOCIATES, LLC CURRENT ZONING = SP2 L.U.D.= MIXED USE CI CI CI CI CI 6 26' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 24' 26'26' GI GI GI GI GI GI 246' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED 20' DRAINAGE EASEMENT EXISTING PAINTED GORE EXISTING PHYSICAL GORE BUILDING 2 RESTAURANT SINGLE-STORY 18'-8" HT 2,861 SF 31' 64'23'23'10'7.5 '18'24'18' 9' 13' 9' 9' 18' 9' 7.5' 18' 26' 18.0'9' 12.5' 13' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 24' 9'13' FH 13' 13' 13' 13'10'7' 704.9'65.0'562' 50' 9'18'18' 18'9'62'155'158'9' CI 204' 33' 24' 6 6 7 11' 15' 13' 18' 48' 18' 20' 1 4 ' 1 ' 1 2 ' 382'5'5' PROPOSED 10' MASONRY SCREEN WALL. JB 12'12' 12'12' 19' 24'3'23' 12'19'50' 100' RO W 50' JB 2668' 9'18' PROPOSED ACCESSIBLE PARKING SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH 7' LOT 2, BLOCK A 9.509 ACRES 414,231 SF LOT 1, BLOCK A 2.996 ACRES 130,492 SF PROPOSED EV PARKING SPACE PROPOSED CART CORRAL LOCATION, PROPOSED 20' DRAINAGE EASEMENT PROPOSED 20' DRAINAGE EASEMENT PROPOSED 25' DRAINAGE EASEMENT PROPOSED DETENTION EASEMENT PROPOSED 15' DRAINAGE EASEMENT PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT SSMH PROPOSED CART CORRAL LOCATION, PROPOSED 4' CONCRETE KNEE WALL R=30.0'R=30.0'R=30.0'R =30.0'R=30.0'R =30.0' R =3 0 .0 'R=30.0'R=30.0'R =30.0'R=15.0'R =15. 0 ' R=30.0' R =3 0 .0 'R=30.0'R=30.0'R=54.0'R=20.0'R=30.0 ' R =5 4 .0 'R=54.0'R=30.0'R =6 0 .0 ' R=3 0. 0 ' R=54.0' R =30.0' R=30.0'R=30.0'R=54.0'R =10.0'R=30.0'R =30.0'R=7 0 .0'R=70.0'R=75.0'R=215.0'R=30.0' R =72.0' R =3 0 .0 'R=3 0 .0 'R=30.0 'R=40.0'=20.0'R=2 0 R =2 0.0'17' R =30.0' FH SSMH 1 R=30.0' CI R =30.0'R =3 0.0' CI 8' PROPOSED 8' SIDEWALK 8' 8' PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK5' FH24'PROPOSED 25' ACCESS EASEMENT R=30.0' R =3 0 .0'*A FUTURE DETAILED SITE PLAN WILL BE SUBMITTED FOR LOT 1, BLOCK A. THE USE WILL COMPLY WITH THE ALLOWED USES IN THE DEVELOPMENT STANDARDS 10' 40' 40' S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W 8"W8"W S S S S S S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W 8"W8"W S S S S SWOHEOHEOHE OHE OHEOHEOHEOHEOHEOHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE N89°28'39"E 1663.12'FLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FLFLFLFLFLFL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLF L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLEV EV EV EV CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE LOT 1 BUILDING 4 GROCER SINGLE-STORY - 44'-0" HT 33,798 SF BUILDING 5 RETAIL SINGLE-STORY 29'-6" HT 18,551 SF BUILDING 3 RESTAURANT SINGLE-STORY 24' HT 3,914 SF BUILDING 6 RESTAURANT SINGLE-STORY BUILDING 7 RESTAURANT SINGLE-STORY 27' HT 7,500 SF JB PORTION OF A CALLED 55.300 ACRES SOUTHLAKE DOVE ASSOCIATES, LLC DOC. NO. D215094206 O.P.R.T.C.T. PARCEL ID NO. 41248848 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 931 D.R.T.C.T. 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 14 14 19 22 4 12 13 22 22 22 22 22 22 20 9 13 13 13 9 9 13 11 25 7 20 6 25 5 7 31 14 9 11 13 9 21 38' 10' BUFFERYARD PROPOSED 4 ' RETAINING WALL FOR DETENTION POND PROPOSED DRIVEWAY 247' 68'78'13'13'E K IRKWOOD BLVD STRE E T A18'24'18'18'18'24'11'26'18'18'18'24'18'18'24'10'18'18'24'18'24'18'18'18'24'18'18'24'18'24'18'18'18'24'18'30'18' 19'225' 153' 84' 61' 62'110' 75'57' 50' 50'30' FH FH FH FH FH FH FH FH FH FH JB JB JB JB JB JB JB 18'24'18' PROPOSED DETENTION POND 24' 6' 18' 24' 9' 18'50' BU ILD ING SETBACK60' 62' 69' CI CI CI CI CI 6 26' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 24' 26'26' GI GI GI GI GI GI PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED 20' DRAINAGE EASEMENT BUILDING 2 RESTAURANT SINGLE-STORY 18'-8" HT 2,861 SF 31' 64'23'23'10'7.5 '18'24'18' 9' 13' 9' 9' 18' 9' 7.5' 18' 26' 18.0'9' 12.5' 13' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 24' 9'13' FH 13' 13' 13' 13'10'7' 704.9'65.0'562' 50' 18'9'9' CI 33' 24' 6 7 11' 15' 13' 18' 48' 18' 20' 1 4 ' 1 ' 1 2 ' 382'5'5' PROPOSED 10' MASONRY SCREEN WALL. JB 12'12' 12'12' 19' 24'3'23' 12'19'50' 100' RO W 50' JB 2668' 9'18' PROPOSED ACCESSIBLE PARKING SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH 7' LOT 2, BLOCK A 9.509 ACRES 414,231 SF LOT 1, BLOCK A 2.996 ACRES 130,492 SF PROPOSED EV PARKING SPACE PROPOSED CART CORRAL LOCATION, PROPOSED 20' DRAINAGE EASEMENT PROPOSED 20' DRAINAGE EASEMENT PROPOSED 25' DRAINAGE EASEMENT PROPOSED DETENTION EASEMENT PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT SSMH PROPOSED CART CORRAL LOCATION, PROPOSED 4' CONCRETE KNEE WALL R=30.0'R=30.0'R=30.0'R =30.0'R=30.0'R =30.0' R =3 0 .0 'R=30.0'R =30.0'R=15.0'R =15. 0 ' R =3 0 .0 'R=30.0'R=30.0'R=54.0'R=20.0'R=30.0 ' R =5 4 .0 'R=54.0'R=30.0'R =6 0 .0 ' R=3 0. 0 ' R=54.0' R =30.0' R=30.0'R=30.0'R=54.0'R =10.0'R=30.0'R =30.0'R=7 0 .0'R=70.0'R=75.0'R=215.0'R=30.0' R =72.0' R =3 0 .0 'R=3 0 .0 'R=30.0 'R=40.0'=20.0'R=2 0 R =2 0.0'17' R =30.0' FH SSMH 1 R=30.0' CI R =30.0'R =3 0.0' CI 8' 8' PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK5' FH PROPOSED 25' ACCESS EASEMENT R=30.0' R =3 0 .0'S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S F L FLFLFLF L FL FLFLFLFLFLFL FLFLEVEV EV EV CITY OF SOUTHLAKEUTILITY EASEMENTVOL. 8405, PG. 1444D.R.T.C.T.15' DRAINAGE EASEMENTDOC. NO. D221095079O.P.R.T.C.T.This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED8/21/2025 3:24 PMPLOTTED BYBORAWSKI, ALINA 8/21/2025 3:37 PMDWG PATHK:\DAL_CIVIL\067545015-TRADEMARK SOUTHLAKE\CAD\PHASE 1\PLANSHEETSDWG NAMEC-SITE-PLAN.DWG , [ 1 OF 4 ]IMAGES EPSG2276_Date20250115_Lat32.965999_Lon-97.153911_Mpp0.300_Vert :XREFS xArch : xBase : xBndry : xEsmt : xExBase : xExUtil : xHardscape : xLabel : xPlant : xStrm : xUtil : x24X36 : xRoundabout : xRow-WC : xPave-WC : xSingleFamily : xEsmt-Commerical : xRoad-New WC : xbndy : xHatch : xHard : xSite-South : xAerial© 2025 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL RD. TWO GALLERIA OFFICE TOWERSUITE 700 DALLAS, TX 752408/21/2025CITY OF SOUTHLAKE, TXTRADEMARK SOUTHLAKE067545015AGBQEKCMDSITE PLAN(1 OF 4)C-101 1.ALL SIGNAGE IS APPROVED VIA SEPARATE PERMITTING PROCESS. 2.PARKING SPACE RETURN RADII ARE 3' OR 10' UNLESS OTHERWISE NOTED. 3.DUMPSTER ENCLOSURES SHOULD NOT BE SEEN FROM THE PUBLIC RIGHT-OF-WAY. SCREENING OF THE DUMPSTERS SHALL BE OF THE SAME MASONRY MATERIAL AS THE PRIMARY STRUCTURE AND BE A MINIMUM OF EIGHT (8) FEET IN HEIGHT. SOLID METAL GATES SHALL BE AFFIXED TO THE OPENING AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN BEING SERVICED. 4.ALL LIGHT SOURCES, INCLUDING WALL PACKS, SHALL BE FULL CUT-OFFS (I.E. RECESSED/SHIELDED). 5.ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE SUFFICIENTLY SCREENED FROM VIEW BY PARAPET WALLS, AND GROUND MOUNTED EQUIPMENT SHALL BE SCREENED BY MASONRY WING WALLS THAT MATCH THE MATERIAL OF THE PRIMARY BUILDING OR ADEQUATE LANDSCAPING. 6.NO OVERHEAD UTILITIES ARE PERMITTED ON THE SUBJECT PROPERTY. 7.ALL PARKING SPACES TO BE 9’ X18'. 8.ALL STRIPING IN PARKING LOTS SHALL BE WHITE. 9.HANDICAPPED ACCESS RAMPS SHALL BE PAINTED OR CONSTRUCTED OF CONTRASTING COLORS FROM THE STANDARD PAVEMENT BUT SHALL NOT BE IN COLORS THAT ARE CONSIDERED BRIGHT, NEON, OR GARISH. 10.FIRE APPARATUS ACCESS ROADS TO BE AN ALL-WEATHER SURFACE, ASPHALT OR CONCRETE, 24 FEET WIDE AND ABLE TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS. (MINIMUM OF 85,000 POUNDS GVW). CITY SITE PLAN NOTES SITE PLAN FOR CITY REVIEW ONLY TO ILLUSTRATE COMPLIANCE WITH ZONING AND DEVELOPMENTS REGULATIONS. IT IS NOT INTENDED FOR CONSTRUCTION PURPOSES. MATC H LI N E S E E S H E E T C-10 3 MATCH LINE SEE SHEET C-102MATC H LI N E S E E S H E E T C-10 4 C-101 C-103 C-104 C-102 KEYMAP NORTH ENGINEER / SURVEYOR / APPLICANT / LANDSCAPE ARCHITECT / IRRIGATOR: KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL ROAD, TWO GALLERIA OFFICE TOWER, SUITE 700, DALLAS, TX. 75240 PHONE: (469) 914-8611 CONTACT: PEYTON MCGEE, P.E. 40.20 ACRES JAMES J. WEST SURVEY, ABSTRACT NO. 1620 CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS SUBMITTED AUGUST 21, 2025 OWNER: SHIVERS FAMILY PARTNERSHIP 1800 N WHITE CHAPEL BLVD SOUTHLAKE, TX 76092-3617 CONTACT: REBECCA UTLEY ARCHITECT: DWELL DESIGN STUDIO CONTACT: RYAN MILLER PHONE: (770) 864-1035 EMAIL: RMILLER@DWELLDESIGNSTUDIO.COM SITE PLAN TRADEMARK SOUTHLAKE CITY CASE NO. ZA25-0045 DEVELOPER: TRADEMARK PROPERTY COMPANY 1701 RIVER RUN #500 FORTH WORTH, TX 76107 CONTACT: BLAKE BICKMORE EMAIL: BBICKMORE@TRADEMARKPROPERTY.COM (TYP.) X LEGEND EX S JB PROPERTY LINE PROPOSED FIRE LANE PROPOSED FIRE HYDRANT PROPOSED CURB INLET PROPOSED FDC/WATER METER PROPOSED SANITARY SEWER MANHOLE PROPOSED GRATE INLET PROPOSED JUNCTION BOX PROPOSED RETAINING WALL ACCESSIBLE PARKING SYMBOL NUMBER OF PARKING SPACES PROPOSED BUILDING ENTRANCE TYPICAL EXISTING PROPOSED LIGHT DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT PUBLIC CONCRETE PAVEMENT FH CI WM PROP. GI JB FDC S S S S S S S S S SW OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE CBLCBLCBLCBLCBLCBLCBLCBLCBLCBLGASCBLCBLCBLGASGASGASGASGASGASOHEOHEOHEOHEOHEOHEOHE S0°18'41"E 1274.60' // / /// LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 CITY OF SOUTHLAKE UTILITY EASEMENT VOL. 8405, PG. 1444 D.R.T.C.T. 15' DRAINAGE EASEMENT DOC. NO. D221095079 O.P.R.T.C.T. PROPOSED 7' RETAINING WALL PROPOSED 7' RETAINING WALL E KIRKWOOD BLVDE KIRKWOOD BLVD STREET B 50' ROW 100' ROW50' ROW24'45' HALF ROW DEDICATION FH FH FH FH JB CI CI CI CI CI CI CI CI JBJB 20' LANDSCAPE BUFFER14'62'11' 11' 11' 11' CARILLON PHASE 1A INST. NO D211101073 P.R.T.C.T. 11' 11' 11' 11' 11' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 31' B-B31' B-B 24'1 15' 13' 18' 48' 18' 20' 76'50'50'12'12'14'12'JB 12'12' 12'12' 12' 19'50'50' 18'18' 66'145'83'103' 2 3 SSMH SSMH SSMH SSMHSSMH 14' 12.5'8' 4' EXISTING CONCRETE DRIVEWAY USE: RESIDENTIAL803' TO NEAREST DRIVER=75.0'R =72.0' R = 3 0.0' R =30.0'R=3 0.0'R=90.0'R=90.0'R=100.0'R=110.0'R= 2 0 .0'R=20.0 'R=3 0 .0 ' R=30.0 'R=30.0'8'12'5'8' 8' PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK 5'PROPOSED 5' SIDEWALK 5'PROPOSED 8' SIDEWALK FH FH5'5'5'8'PROPOSED MAILBOX CLUSTER LOCATION R =3 0 .0'R=30.0' 8"W S S S S S 8"W S S S S SW OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE CBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLGASCBLCBLCBLCBLCBLGASGASGASGASGASGASGASOHEOHEOHEOHEOHEOHEOHE S0°18'41"E 1274.60'//////FL LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. CITY OF SOUTHLAKE UTILITY EASEMENT VOL. 8405, PG. 1444 D.R.T.C.T. 15' DRAINAGE EASEMENT DOC. NO. D221095079 O.P.R.T.C.T. 21 PROPOSED 7' RETAINING WALL PROPOSED 7' RETAINING WALL E KIRKWOOD BLVDE K IRKWOOD BLVD STREET B 50' ROW 100' ROW50' ROW24'45' HALF ROW DEDICATION FH FH FH FH JB JB 18' 69' CI CI CI CI CI CI CI CI JBJB 20' LANDSCAPE BUFFER18'14'62'11' 11' 11' 11' CARILLON PHASE 1A INST. NO D211101073 P.R.T.C.T. 11' 11' 11' 11' 11' GI PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 66'31' B-B31' B-B 24'9' 33' 1 7 18' 11' 15' 13' 18' 48' 18' 20' 76'50'50'12'12'14'12'PROPOSED 10' MASONRY SCREEN WALL. JB 12'12' 12'12' 19' 24'3'23' 12' 19'50' 100' RO W 50' 18'18' 66'145'83'103' 2 3 SSMH SSMH SSMH SSMHSSMH 14' 12.5'8' 4' EXISTING CONCRETE DRIVEWAY USE: RESIDENTIAL803' TO NEAREST DRIVE.0'R=3 0. 0 'R= 7 0 . 0'R=70.0'R=75.0'R=215.0'R =72.0' R = 3 0.0' R =30.0'R=3 0.0'R=90.0'R=90.0'R=100.0'R=110.0'R= 2 0 .0'R=20.0'R=3 0 .0 'R=30.0 'R=30.0'R=140.0R=140.0'8'12'5'FH 8' 8' PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK PROPOSED 8' SIDEWALK 5'PROPOSED 5' SIDEWALK 5'PROPOSED 8' SIDEWALK 5' FH FH5'5'5'8'PROPOSED MAILBOX CLUSTER LOCATION R =3 0 .0'R =3 0.0'R=30.0' S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S F L FLFLFLF L FL FLFLFLFLFLFL FLFLEVEV EV EV This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED8/21/2025 2:14 PMPLOTTED BYBORAWSKI, ALINA 8/21/2025 2:17 PMDWG PATHK:\DAL_CIVIL\067545015-TRADEMARK SOUTHLAKE\CAD\PHASE 1\PLANSHEETSDWG NAMEC-SITE-PLAN.DWG , [ 2 OF 4 ]IMAGES EPSG2276_Date20250115_Lat32.965999_Lon-97.153911_Mpp0.300_Vert :XREFS xArch : xBase : xBndry : xEsmt : xExBase : xExUtil : xHardscape : xLabel : xPlant : xStrm : xUtil : x24X36 : xRoundabout : xRow-WC : xPave-WC : xSingleFamily : xEsmt-Commerical : xRoad-New WC : xbndy : xHatch : xHard : xSite-South : xAerial© 2025 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL RD. TWO GALLERIA OFFICE TOWERSUITE 700 DALLAS, TX 752408/21/2025CITY OF SOUTHLAKE, TXTRADEMARK SOUTHLAKE067545015AGBQEKCMDSITE PLAN(2 OF 4)C-102 1.ALL SIGNAGE IS APPROVED VIA SEPARATE PERMITTING PROCESS. 2.PARKING SPACE RETURN RADII ARE 3' OR 10' UNLESS OTHERWISE NOTED. 3.DUMPSTER ENCLOSURES SHOULD NOT BE SEEN FROM THE PUBLIC RIGHT-OF-WAY. SCREENING OF THE DUMPSTERS SHALL BE OF THE SAME MASONRY MATERIAL AS THE PRIMARY STRUCTURE AND BE A MINIMUM OF EIGHT (8) FEET IN HEIGHT. SOLID METAL GATES SHALL BE AFFIXED TO THE OPENING AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN BEING SERVICED. 4.ALL LIGHT SOURCES, INCLUDING WALL PACKS, SHALL BE FULL CUT-OFFS (I.E. RECESSED/SHIELDED). 5.ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE SUFFICIENTLY SCREENED FROM VIEW BY PARAPET WALLS, AND GROUND MOUNTED EQUIPMENT SHALL BE SCREENED BY MASONRY WING WALLS THAT MATCH THE MATERIAL OF THE PRIMARY BUILDING OR ADEQUATE LANDSCAPING. 6.NO OVERHEAD UTILITIES ARE PERMITTED ON THE SUBJECT PROPERTY. 7.ALL PARKING SPACES TO BE 9’ X18'. 8.ALL STRIPING IN PARKING LOTS SHALL BE WHITE. 9.HANDICAPPED ACCESS RAMPS SHALL BE PAINTED OR CONSTRUCTED OF CONTRASTING COLORS FROM THE STANDARD PAVEMENT BUT SHALL NOT BE IN COLORS THAT ARE CONSIDERED BRIGHT, NEON, OR GARISH. 10.FIRE APPARATUS ACCESS ROADS TO BE AN ALL-WEATHER SURFACE, ASPHALT OR CONCRETE, 24 FEET WIDE AND ABLE TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS. (MINIMUM OF 85,000 POUNDS GVW). CITY SITE PLAN NOTES SITE PLAN FOR CITY REVIEW ONLY TO ILLUSTRATE COMPLIANCE WITH ZONING AND DEVELOPMENTS REGULATIONS. IT IS NOT INTENDED FOR CONSTRUCTION PURPOSES. NORTH MATCH LINE SEE SHEET C-104MATCH LINE SEE SHEET C-101KEYMAP C-101 C-103 C-102 C-104 TYPICAL LOT DIMENSION DETAIL NTS ENGINEER / SURVEYOR / APPLICANT / LANDSCAPE ARCHITECT / IRRIGATOR: KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL ROAD, TWO GALLERIA OFFICE TOWER, SUITE 700, DALLAS, TX. 75240 PHONE: (469) 914-8611 CONTACT: PEYTON MCGEE, P.E. OWNER: SHIVERS FAMILY PARTNERSHIP 1800 N WHITE CHAPEL BLVD SOUTHLAKE, TX 76092-3617 CONTACT: REBECCA UTLEY ARCHITECT: DWELL DESIGN STUDIO CONTACT: RYAN MILLER PHONE: (770) 864-1035 EMAIL: RMILLER@DWELLDESIGNSTUDIO.COM SITE PLAN TRADEMARK SOUTHLAKE CITY CASE NO. ZA25-0045 DEVELOPER: TRADEMARK PROPERTY COMPANY 1701 RIVER RUN #500 FORTH WORTH, TX 76107 CONTACT: BLAKE BICKMORE EMAIL: BBICKMORE@TRADEMARKPROPERTY.COM (TYP.) X LEGEND EX S JB PROPERTY LINE PROPOSED FIRE LANE PROPOSED FIRE HYDRANT PROPOSED CURB INLET PROPOSED FDC/WATER METER PROPOSED SANITARY SEWER MANHOLE PROPOSED GRATE INLET PROPOSED JUNCTION BOX PROPOSED RETAINING WALL ACCESSIBLE PARKING SYMBOL NUMBER OF PARKING SPACES PROPOSED BUILDING ENTRANCE TYPICAL EXISTING PROPOSED LIGHT DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT PUBLIC CONCRETE PAVEMENT FH CI WM PROP. GI JB FDC 40.20 ACRES JAMES J. WEST SURVEY, ABSTRACT NO. 1620 CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS SUBMITTED AUGUST 21, 2025 S S SS S S 8"W 8"W 8"W 8"W 8"W S S S S S S SS S S 8"W 8"W 8"W 8"W 8"W S S S S OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE O H E O H E O H E O H E OH E OHE OHE OHE OHE OHE OHE OHE OHE S89°41'16"W 903.45' ∆=12°47'37" R=1889.86' L=421.99' CB=N44°40'29"W C=421.11'FLFL F L F L F L F L F L FLF L F L F L F L F L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFL F L F L F L F L F L F L F L F L F L F L F L FL FL FL FL FL FL FL FL FLFLFLFLFL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLW STATE HWY 1 1 4 BUILDING 6 RESTAURANT SINGLE-STORY 27' HT 6,000 SF BUILDING 7 RESTAURANT SINGLE-STORY 27' HT 7,500 SF BUILDING 8 RESTAURANT SINGLE-STORY 24'-10" HT 12,598 SF BUILDING 10 FIRST FLOOR RESTAURANT 63'-10" HT 5,100 SF BUILDING 11 FIRST FLOOR RESTAURANT 63'-10" HT 6,646 SF BUILDING 12 OFFICE THREE-STORY 63'-10" HT 1ST FLOOR - 6,000 SF 2ND FLOOR - 17,746 SF 3RD FLOOR - 17,746 SF JB 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. 25 5 7 31 14 32 33 5 9 9 16 10 12 2 11 8 20 16 18 10 11 10 9 11 38' PROPOSED DRIVEWAY PROPOSED DRIVEWAY 68'63'82'74'13'13' STRE E T A 19' 62'97'110'169' 75' 81'20' FH FH FH FH FH FH JB JB JB18'24'18'60'60' CI CI CI CI CI CI CI PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 11' 1 0 0 '26' JB PROPOSED 20' DRAINAGE EASEMENT 51' BUILDING 9 RESTAURANT SINGLE-STORY 22'-5" HT 1,554 SF 31'31'23'7.5 '18'24'18' 9' 7.5' 18' 26' 18.0' 7.5' 18' 26' 18' 18' 18' 24'9' 2 4 ' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 13'13'13' FH 13' 13' 2 6 2 '159' 50' 2 7 0 ' 13'9'18'CI 5 382'76'150'5'5'24'18'9 ' 2 0 ' 20' JB 26 SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH7' LOT 3, BLOCK A 9.350 ACRES 407,266 SF PROPOSED 15' SEWER EASEMENT PROPOSED 15' SEWER EASEMENT PROPOSED 20' DRAINAGE EASEMENT PROPOSED DETENTION EASEMENT 9' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 58'SSMH R=75.0'R=30.0'R =3 0 .0 'R=80.0'R =15.0'R=30.0'R=54.0'R =30.0'R=56.0'R=30.0' R=100.0'R=30.0'R=30.0' R =3 0 .0 'R =30.0'R=40.0'R=20.0'R=2 0 . 0 ' R =2 0.0'RR=260.0'17'24'R =30.0'18' R=30.0'9' SSMH R =5 4 .0 '18'R=3 0 .0 '20' 9' 1 R=30.0' CI R =30.0'R =3 0.0' CI SIDEWALK10' 40' 40' S S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W S S S S S S S S S S S S S S S 8"W 8"W 8"W 8"W 8"W 8"W 8"W S S S S S S XOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE O H E O H E O H E O H E OH E OHE OHE OHE OHE OHE OHE OHE OHE ∆=12°47'37" R=1889.86' L=421.99' CB=N44°40'29"W C=421.11'FLFL F L F L F L F L F L FLF L F L F L F L F L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFL F L F L F L F L F L F L F L F L F L F L F L FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL F L FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLCITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE W STATE HWY 1 1 4 BUILDING 3 RESTAURANT SINGLE-STORY 24' HT 3,914 SF BUILDING 6 RESTAURANT SINGLE-STORY 27' HT 6,000 SF BUILDING 7 RESTAURANT SINGLE-STORY 27' HT 7,500 SF BUILDING 8 RESTAURANT SINGLE-STORY 24'-10" HT 12,598 SF BUILDING 10 FIRST FLOOR RESTAURANT 63'-10" HT 5,100 SF BUILDING 11 FIRST FLOOR RESTAURANT 63'-10" HT 6,646 SF BUILDING 12 OFFICE THREE-STORY 63'-10" HT 1ST FLOOR - 6,000 SF 2ND FLOOR - 17,746 SF 3RD FLOOR - 17,746 SF JB 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T.54' 13 25 7 5 7 31 14 32 33 5 9 9 16 10 12 2 11 8 6 20 16 18 10 11 10 9 11 38' PROPOSED DRIVEWAY PROPOSED DRIVEWAY 68'63'82'74'78'13'13' STRE E T A18'18'18'24' 19' 62'97'110'169' 75' 81' 50'20' FH FH FH FH FH FH FH FH FH JB JB JB JB 18'24'18'60'50' BU ILD ING SETBACK60' CI CI CI CI CI CI CI CI CI JB PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 11' 1 0 0 '26' PROPOSED INTERNAL PARK AREA JB PROPOSED 20' DRAINAGE EASEMENT 51' BUILDING 9 RESTAURANT SINGLE-STORY 22'-5" HT 1,554 SF 31'31' 64'23'23'10'7.5 '18'24'18' 9' 7.5' 18' 26' 18.0' 7.5' 18' 26' 18' 18' 18' 24'9' 2 4 ' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 13'13'13' FH 13' 13' 13'7' 2 6 2 '159'562' 50' 2 7 0 ' 13'9'18'CI 5 1 4 ' 1 ' 1 2 ' 382'76'150'5'5'24'18'9 ' 2 0 ' 20' JB 26 SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH 7' LOT 3, BLOCK A 9.350 ACRES 407,266 SF PROPOSED 15' SEWER EASEMENT PROPOSED 15' SEWER EASEMENT PROPOSED 20' DRAINAGE EASEMENT PROPOSED DETENTION EASEMENT 9' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 58'24' SSMH R=75.0'R=30.0'R =3 0 .0 'R=80.0'R =15.0' R=54.0' R=30.0'R=30.0'R=54.0'R =30.0'R=56.0'R=30.0' R=100.0'R=30.0'R =30.0' R=30.0' R =3 0 .0 'R =30.0'R=40.0'R=20.0'R= 4 0.0R=20.0'R=2 0 . 0 ' R =2 0.0'R =1 9 0 .8 'R =1 6 0 .8 'R=290.0'R=260.0'17'24'R =30.0'18' R =30.0'9' SSMH R =5 4 .0 '18'R=3 0 .0 '20' 9' 1 R=30.0' CI R =30.0'R =3 0.0' CI PROPOSED 5' SIDEWALK PROPOSED MAILBOX CLUSTER LOCATION S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S EVEV EV EV This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED8/21/2025 2:14 PMPLOTTED BYBORAWSKI, ALINA 8/21/2025 2:17 PMDWG PATHK:\DAL_CIVIL\067545015-TRADEMARK SOUTHLAKE\CAD\PHASE 1\PLANSHEETSDWG NAMEC-SITE-PLAN.DWG , [ 3 OF 4 ]IMAGES EPSG2276_Date20250115_Lat32.965999_Lon-97.153911_Mpp0.300_Vert :XREFS xArch : xBase : xBndry : xEsmt : xExBase : xExUtil : xHardscape : xLabel : xPlant : xStrm : xUtil : x24X36 : xRoundabout : xRow-WC : xPave-WC : xSingleFamily : xEsmt-Commerical : xRoad-New WC : xbndy : xHatch : xHard : xSite-South : xAerial© 2025 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL RD. TWO GALLERIA OFFICE TOWERSUITE 700 DALLAS, TX 752408/21/2025CITY OF SOUTHLAKE, TXTRADEMARK SOUTHLAKE067545015AGBQEKCMDSITE PLAN(3 OF 4)C-103 1.ALL SIGNAGE IS APPROVED VIA SEPARATE PERMITTING PROCESS. 2.PARKING SPACE RETURN RADII ARE 3' OR 10' UNLESS OTHERWISE NOTED. 3.DUMPSTER ENCLOSURES SHOULD NOT BE SEEN FROM THE PUBLIC RIGHT-OF-WAY. SCREENING OF THE DUMPSTERS SHALL BE OF THE SAME MASONRY MATERIAL AS THE PRIMARY STRUCTURE AND BE A MINIMUM OF EIGHT (8) FEET IN HEIGHT. SOLID METAL GATES SHALL BE AFFIXED TO THE OPENING AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN BEING SERVICED. 4.ALL LIGHT SOURCES, INCLUDING WALL PACKS, SHALL BE FULL CUT-OFFS (I.E. RECESSED/SHIELDED). 5.ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE SUFFICIENTLY SCREENED FROM VIEW BY PARAPET WALLS, AND GROUND MOUNTED EQUIPMENT SHALL BE SCREENED BY MASONRY WING WALLS THAT MATCH THE MATERIAL OF THE PRIMARY BUILDING OR ADEQUATE LANDSCAPING. 6.NO OVERHEAD UTILITIES ARE PERMITTED ON THE SUBJECT PROPERTY. 7.ALL PARKING SPACES TO BE 9’ X18'. 8.ALL STRIPING IN PARKING LOTS SHALL BE WHITE. 9.HANDICAPPED ACCESS RAMPS SHALL BE PAINTED OR CONSTRUCTED OF CONTRASTING COLORS FROM THE STANDARD PAVEMENT BUT SHALL NOT BE IN COLORS THAT ARE CONSIDERED BRIGHT, NEON, OR GARISH. 10.FIRE APPARATUS ACCESS ROADS TO BE AN ALL-WEATHER SURFACE, ASPHALT OR CONCRETE, 24 FEET WIDE AND ABLE TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS. (MINIMUM OF 85,000 POUNDS GVW). CITY SITE PLAN NOTES SITE PLAN FOR CITY REVIEW ONLY TO ILLUSTRATE COMPLIANCE WITH ZONING AND DEVELOPMENTS REGULATIONS. IT IS NOT INTENDED FOR CONSTRUCTION PURPOSES. MATC H LI N E S E E S H E E T C-10 1 MATCH L INE SEE SHEET C-104 KEYMAP C-101 C-103 C-102 C-104 NORTH ENGINEER / SURVEYOR / APPLICANT / LANDSCAPE ARCHITECT / IRRIGATOR: KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL ROAD, TWO GALLERIA OFFICE TOWER, SUITE 700, DALLAS, TX. 75240 PHONE: (469) 914-8611 CONTACT: PEYTON MCGEE, P.E. OWNER: SHIVERS FAMILY PARTNERSHIP 1800 N WHITE CHAPEL BLVD SOUTHLAKE, TX 76092-3617 CONTACT: REBECCA UTLEY ARCHITECT: DWELL DESIGN STUDIO CONTACT: RYAN MILLER PHONE: (770) 864-1035 EMAIL: RMILLER@DWELLDESIGNSTUDIO.COM SITE PLAN TRADEMARK SOUTHLAKE CITY CASE NO. ZA25-0045 DEVELOPER: TRADEMARK PROPERTY COMPANY 1701 RIVER RUN #500 FORTH WORTH, TX 76107 CONTACT: BLAKE BICKMORE EMAIL: BBICKMORE@TRADEMARKPROPERTY.COM (TYP.) X LEGEND EX S JB PROPERTY LINE PROPOSED FIRE LANE PROPOSED FIRE HYDRANT PROPOSED CURB INLET PROPOSED FDC/WATER METER PROPOSED SANITARY SEWER MANHOLE PROPOSED GRATE INLET PROPOSED JUNCTION BOX PROPOSED RETAINING WALL ACCESSIBLE PARKING SYMBOL NUMBER OF PARKING SPACES PROPOSED BUILDING ENTRANCE TYPICAL EXISTING PROPOSED LIGHT DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT PUBLIC CONCRETE PAVEMENT FH CI WM PROP. GI JB FDC 40.20 ACRES JAMES J. WEST SURVEY, ABSTRACT NO. 1620 CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS SUBMITTED AUGUST 21, 2025 10' 40' S S S S S S S 8"W 8"W 8"W8"W S S S S S S S S S S S S S S S 8"W 8"W 8"W8"W S S S S S S S S XOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE CBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLGASGASGASGASGASGASGASGASOHES89°41'16"W 903.45' F L F L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLF L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL F L FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE N WHITE CHAPEL BLVDBUILDING 8 RESTAURANT SINGLE-STORY 24'-10" HT 12,598 SF BUILDING 10 FIRST FLOOR RESTAURANT 63'-10" HT 5,100 SF BUILDING 11 FIRST FLOOR RESTAURANT 63'-10" HT 6,646 SF BUILDING 12 OFFICE THREE-STORY 63'-10" HT 1ST FLOOR - 6,000 SF 2ND FLOOR - 17,746 SF 3RD FLOOR - 17,746 SF BUILDING 13 FUTURE RESTAURANT SINGLE-STORY 9,514 SF JB 126'54' 9 10 12 2 11 8 6 20 16 18 10 11 10 9 12 12 13 15 15 15 12 14 15 17 14 863'82'74' EXISTING CONCRETE DRIVEWAY USE: COMMERCIAL STREET C 50' ROW50' ROW99' ROW 55' HALF ROW DEDICATION 18'882.1' DRIVEWAY SPACING169' 81'106'50' ROW 20' FH FH FH FH FH FH FH FH FH JB JB CI CI CI CI CI CI CI CI CI CI CI CI JB JB JB 18' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 100'101'EX. 44' ROW DEDICATION BY CARILLON PARC PHASE 1A PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED INTERNAL PARK AREA JB PROPOSED 20' DRAINAGE EASEMENT 66' 7.5' 18' 26' 18.0' 7.5' 18' 26' 18' 18' 18' 24'9'18'18'18'18'24'24'24'7'6.5'24'31' B-B10' 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. 13'13'13'13'13'88.0'81.1' 13'9'18'24'18'90' CI 4 18' 1 4 ' 1 ' 1 2 '76'150'24'125'125'125'80'125'20' JB 26 FH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH LOT 3, BLOCK A 9.350 ACRES 407,266 SF LOT 3, BLOCK A 9.350 ACRES 407,266 SF PROPOSED 15' SEWER EASEMENT PROPOSED 15' SEWER EASEMENT PROPOSED 20' DRAINAGE EASEMENT 9' 9' 24' SSMH 23'70' 80' 70' R=75.0'R=30.0'R =30.0'R =3 0 .0 'R=80.0'15.0' R =30.0'R=56.0'R=30.0' R=100.0' R= 3 0 .0 ' R =30.0' R =30.0'R= 7 0 . 0'R=215.0'R=30.0' R =30.0'R=140.0'R=140.0'R=160.0'R=160.0'R=20.0'R=20.0' R = 2 0 .0' R= 2 5.0'R=40.0'R=20.0'R=20.0'R= 4 0.0'R =2 0 .0 'R=20.0'R=2 0 . 0 ' R =2 0.0'R=20.0' R =25.0'R =1 9 0 .8 'R =1 6 0 .8 'R=290.0'R=260.0' 31' B-B 5'5'18' R =30.0'9' SSMH 9'R=30 . 0' R =54.0' R=54.0' R =30.0' R=30.0' R = 5 4 . 0 ' R =5 4 .0 ' 20' 9'5'5'5'5'PROPOSED 5' SIDEWALK PROPOSED 5' SIDEWALK PROPOSED MAILBOX CLUSTER LOCATION10' 40' 40' S S S S S S S S S 8"W 8"W 8"W 8"W8"W S S S S S S S S S S S S S S S S S S S 8"W 8"W 8"W 8"W8"W S S S S S S S S S S XOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEO H E OH E OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE CBLCBLGASCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLCBLGASGASGASGASGASGASGASGASOHES89°41'16"W 903.45' F L F L F L F L FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLF L F L F L FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FL FL FL FL FL FL FL F L FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FLFLFLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLCITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE CITY OF SOUTHLAKE 40'X10' VISIBILITY TRIANGLE N WHITE CHAPEL BLVDBUILDING 8 RESTAURANT SINGLE-STORY 24'-10" HT 12,598 SF BUILDING 10 FIRST FLOOR RESTAURANT 63'-10" HT 5,100 SF BUILDING 11 FIRST FLOOR RESTAURANT 63'-10" HT 6,646 SF BUILDING 12 OFFICE THREE-STORY 63'-10" HT 1ST FLOOR - 6,000 SF 2ND FLOOR - 17,746 SF 3RD FLOOR - 17,746 SF BUILDING 13 FUTURE RESTAURANT SINGLE-STORY 9,514 SF JB 126'54' 9 7 5 9 9 16 10 12 2 11 8 6 20 16 18 10 11 10 9 11 12 12 13 15 15 15 12 14 15 17 14 8247'63'82'74' EXISTING CONCRETE DRIVEWAY USE: COMMERCIAL STREET C 50' ROW50' ROW99' ROW 55' HALF ROW DEDICATION 18'882.1' DRIVEWAY SPACING169' 75' 81'106'50' ROW 20' FH FH FH FH FH FH FH FH FH FH FH JB JB JB CI CI CI CI CI CI CI CI CI CI CI CI CI JB JB JB 18' PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS 100'101'EX. 44' ROW DEDICATION BY CARILLON PARC PHASE 1A PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED SCREEN WALL. REFER TO LANDSCAPE PLANS FOR DETAILS PROPOSED INTERNAL PARK AREA JB PROPOSED 20' DRAINAGE EASEMENT 66' 51'31' 64'23'23'10' 7.5' 18' 26' 18.0' 7.5' 18' 26' 18' 18' 18' 24'9'18'18'18'18'24'24'24'7'6.5'24'31' B-B10' 10' WIDE PORTION OF A CALLED 20' WIDE RIGHT-OF-WAY EASEMENT TRI-COUNTY ELECTRIC CO-OPERATIVE, INC. VOL. 9300, PG. 933 D.R.T.C.T. 13'13'13'13'13'88.0'81.1' 13'9'18'24'18'90' CI 4 18' 48' 18' 20'12'1 4 ' 1 ' 1 2 '76'150'24'125'125'125'80'125'2 0 ' 20' JB 26 FH 2 SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH SSMH LOT 3, BLOCK A 9.350 ACRES 407,266 SF LOT 3, BLOCK A 9.350 ACRES 407,266 SF PROPOSED 15' SEWER EASEMENT PROPOSED 15' SEWER EASEMENT PROPOSED 20' DRAINAGE EASEMENT PROPOSED 25' DRAINAGE EASEMENT 9' PROPOSED 26' ACCESS, DRAINAGE AND UTILITY EASEMENT 9' 24' SSMH 23'70' 80' 70' R=75.0'R=30.0'R =30.0'R =3 0 .0 'R=80.0'R =15.0' R =30.0' R=30.0' R =30.0'R=56.0'R=30.0' R=100.0' R= 3 0 .0 ' R =30.0' R =30.0'R= 7 0 .0'R=70R=215.0'R=30.0' R = 3 0.0' R =30.0'R=30.0'R=140.0'R=140.0'R=160.0'R=160.0'R=20.0'R=20.0' R = 2 0 .0' R= 2 5.0'R=40.0'R=20.0'R= 20.0'R= 4 0.0'R =2 0 .0 'R=20.0'R=2 0 .0 ' R =2 0.0'R=20.0' R =25.0'R =1 9 0 .8 'R =1 6 0 .8 'R=290.0'R=260.0'5'31' B-B 5'5' R =30.0'18' R =30.0'9' SSMH 9'R=30 .0' R =54.0' R=54.0' R =30.0' R=30.0' R = 5 4 .0 ' R =5 4 .0 ' 20' 9' R =30.0'R =3 0.0'5'5'5'5'PROPOSED 5' SIDEWALK PROPOSED 5' SIDEWALK FH5'PROPOSED MAILBOX CLUSTER LOCATION R=30.0' S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S F L FLFLFLF L FL FLFLFLFLFLFL FLFLEVEV EV EV This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.BYDATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED8/21/2025 2:14 PMPLOTTED BYBORAWSKI, ALINA 8/21/2025 2:17 PMDWG PATHK:\DAL_CIVIL\067545015-TRADEMARK SOUTHLAKE\CAD\PHASE 1\PLANSHEETSDWG NAMEC-SITE-PLAN.DWG , [ 4 OF 4 ]IMAGES EPSG2276_Date20250115_Lat32.965999_Lon-97.153911_Mpp0.300_Vert :XREFS xArch : xBase : xBndry : xEsmt : xExBase : xExUtil : xHardscape : xLabel : xPlant : xStrm : xUtil : x24X36 : xRoundabout : xRow-WC : xPave-WC : xSingleFamily : xEsmt-Commerical : xRoad-New WC : xbndy : xHatch : xHard : xSite-South : xAerial© 2025 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL RD. TWO GALLERIA OFFICE TOWERSUITE 700 DALLAS, TX 752408/21/2025CITY OF SOUTHLAKE, TXTRADEMARK SOUTHLAKE067545015AGBQEKCMDSITE PLAN(4 OF 4)C-104 1.ALL SIGNAGE IS APPROVED VIA SEPARATE PERMITTING PROCESS. 2.PARKING SPACE RETURN RADII ARE 3' OR 10' UNLESS OTHERWISE NOTED. 3.DUMPSTER ENCLOSURES SHOULD NOT BE SEEN FROM THE PUBLIC RIGHT-OF-WAY. SCREENING OF THE DUMPSTERS SHALL BE OF THE SAME MASONRY MATERIAL AS THE PRIMARY STRUCTURE AND BE A MINIMUM OF EIGHT (8) FEET IN HEIGHT. SOLID METAL GATES SHALL BE AFFIXED TO THE OPENING AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN BEING SERVICED. 4.ALL LIGHT SOURCES, INCLUDING WALL PACKS, SHALL BE FULL CUT-OFFS (I.E. RECESSED/SHIELDED). 5.ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE SUFFICIENTLY SCREENED FROM VIEW BY PARAPET WALLS, AND GROUND MOUNTED EQUIPMENT SHALL BE SCREENED BY MASONRY WING WALLS THAT MATCH THE MATERIAL OF THE PRIMARY BUILDING OR ADEQUATE LANDSCAPING. 6.NO OVERHEAD UTILITIES ARE PERMITTED ON THE SUBJECT PROPERTY. 7.ALL PARKING SPACES TO BE 9’ X18'. 8.ALL STRIPING IN PARKING LOTS SHALL BE WHITE. 9.HANDICAPPED ACCESS RAMPS SHALL BE PAINTED OR CONSTRUCTED OF CONTRASTING COLORS FROM THE STANDARD PAVEMENT BUT SHALL NOT BE IN COLORS THAT ARE CONSIDERED BRIGHT, NEON, OR GARISH. 10.FIRE APPARATUS ACCESS ROADS TO BE AN ALL-WEATHER SURFACE, ASPHALT OR CONCRETE, 24 FEET WIDE AND ABLE TO SUPPORT THE IMPOSED LOADS OF FIRE APPARATUS. (MINIMUM OF 85,000 POUNDS GVW). CITY SITE PLAN NOTES SITE PLAN FOR CITY REVIEW ONLY TO ILLUSTRATE COMPLIANCE WITH ZONING AND DEVELOPMENTS REGULATIONS. IT IS NOT INTENDED FOR CONSTRUCTION PURPOSES. MATC H LI N E S E E S H E E T C-10 1 MATCH LINE SEE SHEET C-101 MATCH L INE SEE SHEET C-103 C-101 C-103 C-102 KEYMAP C-104 NORTH TYPICAL LOT DIMENSION DETAIL NTS ENGINEER / SURVEYOR / APPLICANT / LANDSCAPE ARCHITECT / IRRIGATOR: KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL ROAD, TWO GALLERIA OFFICE TOWER, SUITE 700, DALLAS, TX. 75240 PHONE: (469) 914-8611 CONTACT: PEYTON MCGEE, P.E. OWNER: SHIVERS FAMILY PARTNERSHIP 1800 N WHITE CHAPEL BLVD SOUTHLAKE, TX 76092-3617 CONTACT: REBECCA UTLEY ARCHITECT: DWELL DESIGN STUDIO CONTACT: RYAN MILLER PHONE: (770) 864-1035 EMAIL: RMILLER@DWELLDESIGNSTUDIO.COM SITE PLAN TRADEMARK SOUTHLAKE CITY CASE NO. ZA25-0045 DEVELOPER: TRADEMARK PROPERTY COMPANY 1701 RIVER RUN #500 FORTH WORTH, TX 76107 CONTACT: BLAKE BICKMORE EMAIL: BBICKMORE@TRADEMARKPROPERTY.COM (TYP.) X LEGEND EX S JB PROPERTY LINE PROPOSED FIRE LANE PROPOSED FIRE HYDRANT PROPOSED CURB INLET PROPOSED FDC/WATER METER PROPOSED SANITARY SEWER MANHOLE PROPOSED GRATE INLET PROPOSED JUNCTION BOX PROPOSED RETAINING WALL ACCESSIBLE PARKING SYMBOL NUMBER OF PARKING SPACES PROPOSED BUILDING ENTRANCE TYPICAL EXISTING PROPOSED LIGHT DUTY CONCRETE PAVEMENT HEAVY DUTY CONCRETE PAVEMENT PUBLIC CONCRETE PAVEMENT FH CI WM PROP. GI JB FDC 40.20 ACRES JAMES J. WEST SURVEY, ABSTRACT NO. 1620 CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS SUBMITTED AUGUST 21, 2025