Loading...
Item 12 - ExhibitsNarrative Mustang Court Business Park is a commerce center for light industrial uses located within the City of Southlake off Mustang Court road. The proposed EV chargers will be installed for tenant utilization and will be maintained by Brookfield Properties (landlord). In total, the park will have (7) total chargers that are able to serve (14) parking spaces. •Ex. CED, a current tenant within the park, has requested chargers to be installed for employees to charge their electric vehicles during work hours. J J J J J J J J 1 A 2 3 4 5 6 7 8 9 10 B C D E F G H J K 1 UTILITY PAD MOUNTED TRANSFORMER 2 WP WP LA2-34,36 2#2/0,1#2/0N,1#1G-2"C 3 4 WP WP LA2-30,32 2#4,1#4N,1#4G-1 1/4"C 3 4 WP WP LA2-44,46 2#2/0,1#2/0N,1#1G-2"C 34 WP WP LA2-38,40 2#3,1#3N,1#4G-1 1/4"C 3 4 OB OB OBOB OB OB OB OB OB OB OB OB OB OB OB OB OA OA OA HA2-5,7 HA2-9,11 HA2-13,15 5 GENERAL NOTES 1 COORDINATE EXACT LOCATION OF EXTERIOR BUILDING MOUNTED LIGHTS WITH ARCHITECTURAL ELEVATIONS. 2 ALL POLE MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED ON 37' ROUND TAPERED STEEL POLE AND 36" CONCRETE POLE BASE FOR A TOTAL MOUNTING HEIGHT NOT TO EXCEED 40'. COORDINATE EXACT LOCATION WITH CIVIL, PRIOR TO ROUGH-IN. 3 COORDINATE UTILITY PRIMARY SERVICE REQUIREMENTS WITH PROVIDER. 4 ALL POLE BASE HEIGHTS SHALL BE COORDINATED WITH LOCAL CODES AND HEIGHT RESTRICTIONS. 5 ALL CONDUCTORS SHALL BE #10 AWG, UNLESS OTHERWISE NOTED. 6 ALL UNDERGROUND CONDUITS SHALL BE A MINIMUM 1" SCHEDULE 40 PVC AND SHALL INCLUDE A GROUND WIRE SIZED FOR THE CIRCUIT, UNLESS OTHERWISE NOTED. 7 ALL CIRCUITS SHALL BE ROUTED THROUGH LIGHTING CONTACTOR AND CONTROLLED VIA PHOTOSENSOR AND TIMECLOCK. PROVIDE ROOF MOUNTED PHOTOSENSOR, FACING TRUE NORTH. PHOTOSENSOR AND PHOTOSENSOR CONTROL CARD SHALL BE LIGHTING CONTROL & DESIGN MODEL #GR2400-PCC1 2WO-SMNE4 WITH MOUNTING BOX. 8 EQUAL PRODUCTS BY HUBBELL LIGHTING ARE ACCEPTABLE. PROVIDE FULL PHOTOMETRIC PLAN FOR APPROVAL 9 ALL SERVICE ENTRANCE FEEDERS RUN OUTSIDE BUILDING SHALL BE RUN UNDERGROUND. 10 ALL POLE BASES IN TRUCK PARKING AREAS SHALL BE SET BACK A MINIMUM OF 15' FROM BACK OF CURB 11 ALL POLE LOCATIONS SHALL BE COORDINATED WITH CIVIL ENGINEER, LANDSCAPE ARCHITECT AND ARCHITECT PRIOR TO BEGINNING WORK. ROOF MOUNTED PHOTOCELL FACING TRUE NORTH PHOTOCELL CONTROL RELAY PANEL TO EXTERIOR SIGNS & LIGHTING $INSTALL TOGGLE SWITCH ADJACENT TO CONTACTOR AND LABEL "EXTERIOR LIGHTING OVERRIDE SWITCH" TIME CLOCK, SEE SPECIFICATIONS MECHANICALLY HELD CONTACTOR (POLES AS REQUIRED) 3 #12, 1/2" CONDUIT ROOF HA2 (FOR USE IN LANDSCAPED AREAS GREATER THAN 4' FROM CURB) 3000 PSI CONCRETE BASE WITH "V" BARS VERTICAL AND WITH #"T" TIES "T" O.C. LOCATE FIRST 3 TIES WITHIN TOP 5" OF POLE BASE CONDUIT, QUANTITY AND DIRECTION AS REQUIRED POLE ANCHORBOLTS COVER TO MATCH POLE FINISH 1" CHAMFER ALL AROUND FINISHED GRADE HANDHOLE BUSHING (S) BOND METAL CONDUIT (S), EQUIP. GROUNDING CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR TO POLE 3/4" x 8' - 0" COPPERWELD GROUND ROD 3" MIN"D".BOLT CENTER DIAMETER 3" MIN 4" MIN"E".1 #6 CU GND.2" MINWIND SPEED OF 90 MPH OR LESS POLE HEIGHT ≤15 16' ~ 25' 26' ~ 35' 36' ~ 40' ≤2 LIGHT FIXTURES ON POLE 3 OR 4 LIGHT FIXTURES ON POLE EMBEDMENT (E)DIAMETER (D)DIAMETER (D)EMBEDMENT (E)"V" BARS "T" BARS 1' -6" 2' -0" 2' -6" 3' -0" 4' -6" 5' -3" 5' -9" 6' -0" 1' -6" 2' -0" 2' -6" 3' -0" 4' -9" 5' -6" 6' -3" 6' -3" (6) #5 (6) #6 (6) #7 (6) #8 #3@10" #3@12" #3@14" #3@16"12"3' -0"*STRUCTURAL ENGINEER TO CONFIRM Macgregor Associates Architects, Inc. - 1987-2022C THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE DESIGN PROFESSIONAL. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH EACH PHASE OF HIS WORK. NUMBER DATE DESCRIPTION 2727 Paces Ferry Road SE Building Two, Suite 1400 Atlanta, Georgia 30339 T 770.432.9400 F 770.432.9934 MUSTANG BUSINESS PARK BLDG - 1 PROJECT MUSTANG TEXAS REGISTERED ENGINEERING FIRM F-4990 6/26/2023 6:16:35 PMSITE PLAN - ELECTRICAL E-101 2020-16806/23/22 1855 MUSTANG CT SOUTHLAKE, TX 76092 22010161 AJMc RSP Jordan & Skala Engineers 4275 Shackleford Rd., ● Suite 200 Norcross, GA 30093-2997 p. 770.447.5547 ● f. 770.448.0262 Project Number: Drawn By:Checked By: 1" = 30'-0" 1 SITE PLAN - ELECTRICAL NOTES: UNLESS NOTED OTHERWISE, CONTACTOR(S) SHALL BE IN A NEMA 1 ENCLOSURE. MODEL # TORK K800 TIME CLOCK SHALL BE LOCATED IN ELECTRICAL ROOM. 10 9 SPARE 277 20 1 277 PHOTO TC 8 SPARE 277 20 1 277 PHOTO TC 7 SPARE 480 20 2 277 PHOTO TC 6 SPARE 480 20 2 277 PHOTO TC 5 WALL PACKS 480 20 2 HA2-13,15 277 HA2-24 PHOTO TC 4 WALL PACKS 480 20 2 HA2-9,11 277 HA2-24 PHOTO TC 3 POLE LIGHTS 480 20 2 HA2-5,7 277 HA2-24 PHOTO TC 2 ENTRY CANOPY LIGHTS 277 20 1 HA2-3 277 HA2-22 PHOTO TC 1 ENTRY CANOPY LIGHTS 277 20 1 HA2-1 277 HA2-22 PHOTO TC VOLT AMPS POLE CIRCUIT NUMBERS VOLT CKT. NO. PHOTO/TC PHOTO/TC CONT. NO.LOAD DESCRIPTION CONTACTOR CIRCUIT(S) CONTROL CIRCUIT ON OFF LIGHTING CONTACTOR SCHEDULE NO SCALE 3 EXTERIOR LIGHTING CONTROL DETAIL KEYNOTES 1 PROVIDE 2-4" CONDUITS WITH PULL STRINGS TO PROPERTY LINE FOR TELECOMMUNICATIONS SERVICE. COORDINATE CONDUIT ROUTING AND EXACT DEMARCATION POINT WITH SERVICE PROVIDER. PROVIDE PULL BOXES AS NECESSARY. 2 PROVIDE 1" UNDERGROUND CONDUIT WITH PULL STRINGS FOR FUTURE MONUMENT SIGN. 3 PROVIDE WEATHERPROOF JUNCTION BOX FOR CONNECTION TO ELECTRIC VEHICLE DUAL CHARGING STATIONS. CHARGER SHALL BE CHARGEPOINT CT4000 SERIES. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND LOCATION WITH ARCHITECT/TENANT PRIOR TO ROUGH-IN. 4 PROVIDE WEATHERPROOF TAP BOX TO SPLICE CONDUCTORS, SIZE TAP BOX AS REQUIRED. EXTEND EVC BRANCH CIRCUITS TO TAP BOX, INTERCEPT BRANCH CIRCUIT HOMERUN AND SPLICE AS REQUIRED. SPLICED BRANCH CIRCUIT LENGTH SHALL BE KEPT AS SHORT AS POSSIBLE (MAXIMUM 36"). BRANCH CIRCUIT LENGTH FROM TAP BOX TO EACH EV CHARGERS SHALL BE 2#8, 1#10G IN 3/4"C UNDERGROUND CONDUIT. 06/23/22 PERMIT SET 1 10/07/22 PERMIT COMMENTS 4 04/13/23 CB#4 5 06/26/23 CB#5 NO SCALE 2 EXTENDED POLE BASE JJJJ1A2345678910BCDE9.1A.11.1OBOBOBOBOBOBOBOBOBOBOBOBOBWP4WP3WPWP34LA2-30,324#1/0,2#1/0N,1#1G-2"CLA2-22,244#3,2#3N,1#4G-1 1/4"CUTILITY PAD MOUNTED TRANSFORMER12HA2-7,9HA2-3,55555GENERAL NOTES1COORDINATE EXACT LOCATION OF EXTERIOR BUILDING MOUNTED LIGHTS WITH ARCHITECTURAL ELEVATIONS.2EQUAL PRODUCTS BY HUBBELL LIGHTING ARE ACCEPTABLE. PROVIDE FULL PHOTOMETRIC PLAN FOR APPROVAL 3COORDINATE UTILITY PRIMARY SERVICE REQUIREMENTS WITH PROVIDER.4ALL CONDUCTORS SHALL BE #10 AWG, UNLESS OTHERWISE NOTED.5ALL UNDERGROUND CONDUITS SHALL BE A MINIMUM 1" SCHEDULE 40 PVC AND SHALL INCLUDE A GROUND WIRE SIZED FOR THE CIRCUIT, UNLESS OTHERWISE NOTED.6ALL CIRCUITS SHALL BE ROUTED THROUGH LIGHTING CONTACTOR AND CONTROLLED VIA PHOTOSENSOR AND TIMECLOCK. PROVIDE ROOF MOUNTED PHOTOSENSOR, FACING TRUE NORTH. PHOTOSENSOR AND PHOTOSENSOR CONTROL CARD SHALL BE LIGHTING CONTROL & DESIGN MODEL #GR2400-PCC1 2WO-SMNE4 WITH MOUNTING BOX.7ALL SERVICE ENTRANCE FEEDERS RUN OUTSIDE BUILDING SHALL BE RUN UNDERGROUND.ROOF MOUNTED PHOTOCELLFACING TRUE NORTHPHOTOCELLCONTROLRELAYPANELTO EXTERIOR SIGNS& LIGHTING$INSTALL TOGGLE SWITCH ADJACENT TO CONTACTOR AND LABEL "EXTERIOR LIGHTING OVERRIDE SWITCH"TIME CLOCK, SEE SPECIFICATIONSMECHANICALLY HELD CONTACTOR(POLES AS REQUIRED)3 #12, 1/2" CONDUITROOFHA2Macgregor Associates Architects, Inc. - 1987-2022CTHIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE DESIGN PROFESSIONAL.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH EACH PHASE OF HIS WORK.NUMBERDATEDESCRIPTION2727 Paces Ferry Road SEBuilding Two, Suite 1400Atlanta, Georgia 30339T 770.432.9400 F 770.432.9934MUSTANG BUSINESS PARKBLDG - 2PROJECT MUSTANGTEXAS REGISTERED ENGINEERING FIRM F-49906/28/2023 10:45:52 AMSITE PLAN -ELECTRICALE-1012021-03506/23/221825 MUSTANG CT,SOUTHLAKE, TX 7609222010162AJMcRSPJordan & SkalaEngineers4275 Shackleford Rd., ● Suite 200Norcross, GA 30093-2997p. 770.447.5547 ● f. 770.448.0262Project Number:Drawn By:Checked By:1" = 20'-0"1SITE PLAN - ELECTRICALKEYNOTES1 PROVIDE 2-4" CONDUITS WITH PULL STRINGS TO PROPERTY LINE FORTELECOMMUNICATIONS SERVICE. COORDINATE CONDUIT ROUTING AND EXACTDEMARCATION POINT WITH SERVICE PROVIDER. PROVIDE PULL BOXES ASNECESSARY.2 PROVIDE 1" UNDERGROUND CONDUIT WITH PULL STRINGS FOR FUTURE MONUMENTSIGN.3 PROVIDE WEATHERPROOF JUNCTION BOX FOR CONNECTION TO ELECTRIC VEHICLEDUAL CHARGING STATIONS. CHARGER SHALL BE CHARGEPOINT CT4000 SERIES.COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND LOCATION WITHARCHITECT/TENANT PRIOR TO ROUGH-IN.4 PROVIDE WEATHERPROOF TAP BOX TO SPLICE CONDUCTORS, SIZE TAP BOX ASREQUIRED. EXTEND EVC BRANCH CIRCUITS TO TAP BOX, INTERCEPT BRANCHCIRCUIT HOMERUN AND SPLICE AS REQUIRED. SPLICED BRANCH CIRCUIT LENGTHSHALL BE KEPT AS SHORT AS POSSIBLE (MAXIMUM 36"). BRANCH CIRCUIT LENGTHFROM TAP BOX TO EACH EV CHARGERS SHALL BE 2#8, 1#10G IN 3/4"CUNDERGROUND CONDUIT.NOTES: UNLESS NOTED OTHERWISE, CONTACTOR(S) SHALL BE IN A NEMA 1 ENCLOSURE.MODEL # TORK K800 TIME CLOCK SHALL BE LOCATED IN ELECTRICAL ROOM.10987 SPARE 277 20 1 277 PHOTO TC6 SPARE 277 20 1 277 PHOTO TC5 SPARE 480 20 2 277 PHOTO TC4 SPARE 480 20 2 277 PHOTO TC3 WALL PACKS 480 20 2 HA2-7,9 277 HA2-20 PHOTO TC2 WALL PACKS 480 20 2 HA2-3,5 277 HA2-20 PHOTO TC1 ENTRY CANOPY LIGHTS 277 20 1 HA2-1 277 HA2-20 PHOTO TCVOLT AMPS POLE CIRCUIT NUMBERS VOLT CKT. NO. PHOTO/TC PHOTO/TCCONT.NO.LOAD DESCRIPTIONCONTACTOR CIRCUIT(S) CONTROL CIRCUIT ON OFFLIGHTING CONTACTOR SCHEDULENO SCALE2EXTERIOR LIGHTING CONTROLDETAIL06/23/22 PERMIT SET1 10/07/22 PERMIT COMMENTS4 04/13/23 CB#45 06/26/23 CB#5 J JJ J GENERAL NOTES 1 COORDINATE EXACT LOCATION OF EXTERIOR BUILDING MOUNTED LIGHTS WITH ARCHITECTURAL ELEVATIONS. 2 ALL POLE MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED ON 37' ROUND TAPERED STEEL POLE AND 36" CONCRETE POLE BASE FOR A TOTAL MOUNTING HEIGHT NOT TO EXCEED 40'. COORDINATE EXACT LOCATION WITH CIVIL, PRIOR TO ROUGH-IN. 3 COORDINATE UTILITY PRIMARY SERVICE REQUIREMENTS WITH PROVIDER. 4 ALL POLE BASE HEIGHTS SHALL BE COORDINATED WITH LOCAL CODES AND HEIGHT RESTRICTIONS. 5 ALL CONDUCTORS SHALL BE #10 AWG, UNLESS OTHERWISE NOTED. 6 ALL UNDERGROUND CONDUITS SHALL BE A MINIMUM 1" SCHEDULE 40 PVC AND SHALL INCLUDE A GROUND WIRE SIZED FOR THE CIRCUIT, UNLESS OTHERWISE NOTED. 7 ALL CIRCUITS SHALL BE ROUTED THROUGH LIGHTING CONTACTOR AND CONTROLLED VIA PHOTOSENSOR AND TIMECLOCK. PROVIDE ROOF MOUNTED PHOTOSENSOR, FACING TRUE NORTH. PHOTOSENSOR AND PHOTOSENSOR CONTROL CARD SHALL BE LIGHTING CONTROL & DESIGN MODEL #GR2400-PCC1 2WO-SMNE4 WITH MOUNTING BOX. 8 EQUAL PRODUCTS BY HUBBELL LIGHTING ARE ACCEPTABLE. PROVIDE FULL PHOTOMETRIC PLAN FOR APPROVAL 9 ALL SERVICE ENTRANCE FEEDERS RUN OUTSIDE BUILDING SHALL BE RUN UNDERGROUND. 10 ALL POLE BASES IN TRUCK PARKING AREAS SHALL BE SET BACK A MINIMUM OF 15' FROM BACK OF CURB 11 ALL POLE LOCATIONS SHALL BE COORDINATED WITH CIVIL ENGINEER, LANDSCAPE ARCHITECT AND ARCHITECT PRIOR TO BEGINNING WORK. 1 A B C D 2 3 4 5 6 7 8 9 10 OA OB OA OA OA2OA2 OBOBOB OB OB OB OB OB OB OB OB UTILITY PAD MOUNTED TRANSFORMER 1 2 WP 4 WP 3 WP WP 3 4 LA2-28,30 4#4,2#4N,1#4G-1 1/4"C LA2-24,26 4#1/0,2#1/0N,1#1G-2"C HA2-15,17 HA2-11,13 HA2-7,9 HA2-3,5 5 5 ROOF MOUNTED PHOTOCELL FACING TRUE NORTH PHOTOCELL CONTROL RELAY PANEL TO EXTERIOR SIGNS & LIGHTING $INSTALL TOGGLE SWITCH ADJACENT TO CONTACTOR AND LABEL "EXTERIOR LIGHTING OVERRIDE SWITCH" TIME CLOCK, SEE SPECIFICATIONS MECHANICALLY HELD CONTACTOR (POLES AS REQUIRED) 3 #12, 1/2" CONDUIT ROOF HA2 (FOR USE IN LANDSCAPED AREAS GREATER THAN 4' FROM CURB) 3000 PSI CONCRETE BASE WITH "V" BARS VERTICAL AND WITH #"T" TIES "T" O.C. LOCATE FIRST 3 TIES WITHIN TOP 5" OF POLE BASE CONDUIT, QUANTITY AND DIRECTION AS REQUIRED POLE ANCHORBOLTS COVER TO MATCH POLE FINISH 1" CHAMFER ALL AROUND FINISHED GRADE HANDHOLE BUSHING (S) BOND METAL CONDUIT (S), EQUIP. GROUNDING CONDUCTOR AND GROUNDING ELECTRODE CONDUCTOR TO POLE 3/4" x 8' - 0" COPPERWELD GROUND ROD 3" MIN"D".BOLT CENTER DIAMETER 3" MIN 4" MIN"E".1 #6 CU GND.2" MINWIND SPEED OF 90 MPH OR LESS POLE HEIGHT ≤15 16' ~ 25' 26' ~ 35' 36' ~ 40' ≤2 LIGHT FIXTURES ON POLE 3 OR 4 LIGHT FIXTURES ON POLE EMBEDMENT (E)DIAMETER (D)DIAMETER (D)EMBEDMENT (E)"V" BARS "T" BARS 1' -6" 2' -0" 2' -6" 3' -0" 4' -6" 5' -3" 5' -9" 6' -0" 1' -6" 2' -0" 2' -6" 3' -0" 4' -9" 5' -6" 6' -3" 6' -3" (6) #5 (6) #6 (6) #7 (6) #8 #3@10" #3@12" #3@14" #3@16"12"3' -0"*STRUCTURAL ENGINEER TO CONFIRM Macgregor Associates Architects, Inc. - 1987-2022C THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL AND SHALL NOT BE REPRODUCED, PUBLISHED OR USED IN ANY WAY WITHOUT THE PERMISSION OF THE DESIGN PROFESSIONAL. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING WITH EACH PHASE OF HIS WORK. NUMBER DATE DESCRIPTION 2727 Paces Ferry Road SE Building Two, Suite 1400 Atlanta, Georgia 30339 T 770.432.9400 F 770.432.9934 MUSTANG BUSINESS PARK BLDG - 3 PROJECT MUSTANG TEXAS REGISTERED ENGINEERING FIRM F-4990 6/26/2023 6:42:04 PMSITE PLAN - ELECTRICAL E-101 2021-03606/23/22 1850 MUSTANG CT SOUTHLAKE, TX 76092 22010163 AJMc RSP Jordan & Skala Engineers 4275 Shackleford Rd., ● Suite 200 Norcross, GA 30093-2997 p. 770.447.5547 ● f. 770.448.0262 Project Number: Drawn By:Checked By: NOTES: UNLESS NOTED OTHERWISE, CONTACTOR(S) SHALL BE IN A NEMA 1 ENCLOSURE. MODEL # TORK K800 TIME CLOCK SHALL BE LOCATED IN ELECTRICAL ROOM. 10 9 SPARE 277 20 1 277 PHOTO TC 8 SPARE 277 20 1 277 PHOTO TC 7 SPARE 480 20 2 277 PHOTO TC 6 SPARE 480 20 2 277 PHOTO TC 5 POLE LIGHTS 480 20 2 HA2-15,17 277 HA2-26 PHOTO TC 4 POLE LIGHTS 480 20 2 HA2-11,13 277 HA2-26 PHOTO TC 3 WALL PACKS 480 20 2 HA2-7,9 277 HA2-26 PHOTO TC 2 WALL PACKS 480 20 2 HA2-3,5 277 HA2-24 PHOTO TC 1 ENTRY CANOPY LIGHTS 277 20 1 HA2-1 277 HA2-24 PHOTO TC VOLT AMPS POLE CIRCUIT NUMBERS VOLT CKT. NO. PHOTO/TC PHOTO/TC CONT. NO.LOAD DESCRIPTION CONTACTOR CIRCUIT(S) CONTROL CIRCUIT ON OFF LIGHTING CONTACTOR SCHEDULE 1" = 30'-0" 1 SITE PLAN - ELECTRICAL NO SCALE 3 EXTERIOR LIGHTING CONTROL DETAIL 06/23/22 PERMIT SET 1 10/07/22 PERMIT COMMENTS 4 04/13/23 CB#4 5 06/26/23 CB#5 KEYNOTES 1 PROVIDE 2-4" CONDUITS WITH PULL STRINGS TO PROPERTY LINE FOR TELECOMMUNICATIONS SERVICE. COORDINATE CONDUIT ROUTING AND EXACT DEMARCATION POINT WITH SERVICE PROVIDER. PROVIDE PULL BOXES AS NECESSARY. 2 PROVIDE 1" UNDERGROUND CONDUIT WITH PULL STRINGS FOR FUTURE MONUMENT SIGN. 3 PROVIDE WEATHERPROOF JUNCTION BOX FOR CONNECTION TO ELECTRIC VEHICLE DUAL CHARGING STATIONS. CHARGER SHALL BE CHARGEPOINT CT4000 SERIES. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND LOCATION WITH ARCHITECT/TENANT PRIOR TO ROUGH-IN. 4 PROVIDE WEATHERPROOF TAP BOX TO SPLICE CONDUCTORS, SIZE TAP BOX AS REQUIRED. EXTEND EVC BRANCH CIRCUITS TO TAP BOX, INTERCEPT BRANCH CIRCUIT HOMERUN AND SPLICE AS REQUIRED. SPLICED BRANCH CIRCUIT LENGTH SHALL BE KEPT AS SHORT AS POSSIBLE (MAXIMUM 36"). BRANCH CIRCUIT LENGTH FROM TAP BOX TO EACH EV CHARGERS SHALL BE 2#8, 1#10G IN 3/4"C UNDERGROUND CONDUIT. NO SCALE 2 EXTENDED POLE BASE J J J J J J J 1 A 2 3 4 5 6 7 8 9 10 B C D E F G H J K 1 UTILITY PAD MOUNTED TRANSFORMER 2 WP WP LA2-34,36 2#2/0,1#2/0N,1#1G-2"C 3 4 WP LA2-30,32 2#4,1#4N,1#4G-1 1/4"C 3 J WP 4 WP LA2-44,46 2#2/0,1#2/0N,1#1G-2"C 3 WP4WP LA2-38,40 2#3,1#3N,1#4G-1 1/4"C WP 3 4 OB OB OBOB OB OB OB OB OB OB OB OB OB OB OB OB OA OA OA HA2-5,7 HA2-9,11 HA2-13,15 5 JJ 1 A 2 3 4 5 6 7 8 9 10 B C D E 9.1 A.1 1.1 OB OB OB OB OB OB OB OBOBOB OB OB OB WP 4 WP J 3 WP 3 WP J 4 LA2-30,32 4#1/0,2#1/0N,1#1G-2"C LA2-22,24 4#3,2#3N,1#4G-1 1/4"C UTILITY PAD MOUNTED TRANSFORMER 1 2 HA2-7,9 HA2-3,5 5 5 5 5 J 1 A B C D 2 3 4 5 6 7 8 9 10 OB OA OA2OA2 OBOBOB OB OB OB OB OB OB OB OB UTILITY PAD MOUNTED TRANSFORMER 1 2 J WP 4 J WP 3 WP 3 J WP LA2-28,30 4#4,2#4N,1#4G-1 1/4"C 4 LA2-24,26 4#1/0,2#1/0N,1#1G-2"C HA2-15,17 HA2-11,13 HA2-7,9 HA2-3,5 5 5