Item 8 - Site Plan and Elevations600
600
59518" OAK24" OAK18" OAK7" ELM10" ELM19" ELM17" ELM24" OAK36" OAK18" OAK18" OAK20" OAK18" OAK19" OAK21" OAK22" OAK12" CEDAR2X15" OAK599
599598 59859759640' B.L.40' B.L.
20' B.L.40' B.L.N16' - 0"105' - 10" OVERALL40' - 9 1/4"21' - 1 3/8"21' - 6 7/8"40' - 2 3/4"111' - 4" OVERALL66' - 1 1/8"65' - 7 3/8"N 89°38'18" W 167.58'15' U.E.N 00°21'42" E 249.31'105' - 10"10' U.E.10' U.E.LOT SIZE: 43,638 SQ. FT.~ GENERAL NOTES ~MAXIMUM BUILDING COVEREAGE: 20% OR 8,728 SQ. FT.HOUSE CALCULATION = 6,833/ 43,638 = .1566 or 15.66%~ LOT COVEREAGE SCHEDULE ~ALL WORK MUST CONFORM TO THE 2023 NEC ANDALL AMENDMENTS. ALL WORK MUST CONFORM TO THE 2021 IRC/IBCAND ALL LOCAL AMENDMENTS.BUILDER TO VERIFY LOCATION OF HOUSE, BUILDING LINES, EASEMENTS, AND SIDEYARD SETBACKS PRIOR TO CONSTRUCTION.~ SITE PLAN NOTES ~SCALE: 1"=10.0'10' 20' 40'SUBDIVISION: KEEN HOMEPLACELOT/BLOCK: 6/1STREET: 401 KEEN COURT~ SITE PLAN INFORMATION ~ZONED: SF1-ACITY/STATE: SOUTHLAKECONCRETEDRIVE63' - 9 9/16"401 KEEN COURT40' B.L.40' B.L.40' B.L.20' B.L.S 00°21'42" W 267.47'S 88°25'00" E 54.62'N 83°24'06" E 56.58'42.25'71.25'44.37'16' - 0"10' U.E.L15' - 0"1' - 0"C-1SIDEWALKCONCRETEDRIVESIDEWALK1' - 0"5' - 0"RIDGECREST DRIVECONCRETEWALK83' - 7 1/2"16' - 0"105' - 10" OVERALL40' - 9 1/4"21' - 1 3/8"21' - 6 7/8"40' - 2 3/4"111' - 4" OVERALL66' - 1 1/8"65' - 7 3/8"N 89°38'18" W 167.58'15' U.E.N 00°21'42" E 249.31'105' - 10"10' U.E.10' U.E.CONCRETEDRIVE63' - 9 9/16"401 KEEN COURT40' B.L.40' B.L.40' B.L.20' B.L.S 00°21'42" W 267.47'S 88°25'00" E 54.62'N 83°24'06" E 56.58'42.25'71.25'44.37'16' - 0"10' U.E.L15' - 0"1' - 0"C-1SIDEWALKCONCRETEDRIVESIDEWALKRIDGECREST DRIVECONCRETEWALK83' - 7 1/2"These plans are intended to provide the basic construction information necessary to substantially build the structure. These plans must be verified and checked by the builder or general contractor of this job. Any error and/or emission, if found, is to be brought to the immediate attension of the Designer before construction. Builder should obtain complete engineering services, HVAC, and structural before beginning construction of any kind. NOTE: Federal, State, and Local codes, ordinances and restrictions take precedence over any part of these plans. THESE PLANS AND THEIR USE ARE THE PROPERTY OF J. BOLTON & ASSOCIATES AND ARE NOT TO BE USED FOR CONSTRUCTION, REUSED, TRACED, OR REPRODUCED BY ANY MEANS WITHOUT THE EXPRESSED WRITTEN PERMISSION OF J. BOLTON & ASSOCIATES DIVERSIFIED PLANNING & DEVELOPMENT, INC.COPYRIGHT 2025700 N. CARROLL AVE. SUITE 140SOUTHLAKE, TX. 76092(817)251-9393WWW.JBOLTONDESIGNS.COMAddress:Sheet:Client:Builder:Plan #:Lot/Block:Subdivision:Date:Revision ScheduleDate:Description:401 Keen CourtSouthlake, TX.76092C-101Avnish &Sakuntla PatelCalais CustomHomes(24005)Version 36/1KeenHomeplaceCONSTRUCTIONDOCUMENTS1-29-25
1st F.F.1st F.F.1st F.C.13'1" Plate4:12 Pitch Standing Seam Metal 10'6" Plate13'1" Plate11'1" Plate13'1" Plate17'7" Plate14' - 0"11'1" PlateCement Plaster Finish Walls, Trim & Sills (Typ.)21' - 2" OVERALL9' - 7"11' - 7"16' - 1"11' - 7"9' - 7"F.F.11'1" Plate17'7" Plate13'1" Plate11'1" PlateCement Plaster Finish Walls, Trim & Sills (Typ.)F.F.4:12 Pitch Standing Seam Metal Cement Plaster Finish Walls, Trim & Sills (Typ.)9' - 7"11' - 7"16' - 1"21' - 2"These plans are intended to provide the basic construction information necessary to substantially build the structure. These plans must be verified and checked by the builder or general contractor of this job. Any error and/or emission, if found, is to be brought to the immediate attension of the Designer before construction. Builder should obtain complete engineering services, HVAC, and structural before beginning construction of any kind. NOTE: Federal, State, and Local codes, ordinances and restrictions take precedence over any part of these plans. THESE PLANS AND THEIR USE ARE THE PROPERTY OF J. BOLTON & ASSOCIATES AND ARE NOT TO BE USED FOR CONSTRUCTION, REUSED, TRACED, OR REPRODUCED BY ANY MEANS WITHOUT THE EXPRESSED WRITTEN PERMISSION OF J. BOLTON & ASSOCIATES DIVERSIFIED PLANNING & DEVELOPMENT, INC.COPYRIGHT 2025700 N. CARROLL AVE. SUITE 140SOUTHLAKE, TX. 76092(817)251-9393WWW.JBOLTONDESIGNS.COMAddress:Sheet:Client:Builder:Plan #:Lot/Block:Subdivision:Date:Revision ScheduleDate:Description:401 Keen CourtSouthlake, TX.76092A-103Avnish &Sakuntla PatelCalais CustomHomes(24005)Version 36/1KeenHomeplaceCONSTRUCTIONDOCUMENTS1-29-251/4" = 1'-0"A-1031FRONT ELEVATION1/4" = 1'-0"A-1032RIGHT ELEVATION
13'1" Plate8' - 6"Cement Plaster Finish Walls, Trim & Sills (Typ.)8' - 6"F.F. F.F.10' Tall Folding Glass Doors Inside Porch @ Family Room Wall.4:12 Pitch Standing Seam Metal 11'1" Plate9' - 7"9' - 7"21' - 2"1st F.F.11'1" Plate17'7" Plate13'1" Plate11'1" PlateCement Plaster Finish Walls, Trim & Sills (Typ.)4:12 Pitch Standing Seam Metal 8' - 6"9' - 7"11' - 7"F.F.21' - 2"These plans are intended to provide the basic construction information necessary to substantially build the structure. These plans must be verified and checked by the builder or general contractor of this job. Any error and/or emission, if found, is to be brought to the immediate attension of the Designer before construction. Builder should obtain complete engineering services, HVAC, and structural before beginning construction of any kind. NOTE: Federal, State, and Local codes, ordinances and restrictions take precedence over any part of these plans. THESE PLANS AND THEIR USE ARE THE PROPERTY OF J. BOLTON & ASSOCIATES AND ARE NOT TO BE USED FOR CONSTRUCTION, REUSED, TRACED, OR REPRODUCED BY ANY MEANS WITHOUT THE EXPRESSED WRITTEN PERMISSION OF J. BOLTON & ASSOCIATES DIVERSIFIED PLANNING & DEVELOPMENT, INC.COPYRIGHT 2025700 N. CARROLL AVE. SUITE 140SOUTHLAKE, TX. 76092(817)251-9393WWW.JBOLTONDESIGNS.COMAddress:Sheet:Client:Builder:Plan #:Lot/Block:Subdivision:Date:Revision ScheduleDate:Description:401 Keen CourtSouthlake, TX.76092A-104Avnish &Sakuntla PatelCalais CustomHomes(24005)Version 36/1KeenHomeplaceCONSTRUCTIONDOCUMENTS1-29-251/4" = 1'-0"A-1041REAR ELEVATION1/4" = 1'-0"A-1042LEFT ELEVATION