Loading...
ZA25-0018-ZSP-1963 W Southlake Blvd & 200 S Peytonville Ave PUBLIC HEARING NOTICE ZA25-0018 • Zoning Change, Development Plan and Site Plan for Liberty Commons, on property described as Tracts 3D and 3C02, W R Eaves Survey Abstract No. 500, City of Southlake, Tarrant County, Texas and located at 1963 W. Southlake Blvd and 200 S. Peytonville Ave. • Current Zoning: “S-P-1” Site Plan District and “O-1” Office District • Requested Zoning: “RPUD” Residential Planned Unit Development and “S-P-1” Detailed Site Plan District. • The purpose of this request is to seek approval for a zoning change, development plan and site plan for 14 single-family residential lots and 5 office/retail/commercial lots on approximately 15.1 acres. Dear Property Owner, Your property has been identified as being within 300 feet of the above referenced Zoning Change, Development Plan and Site Plan application. If you wish to register your opposition or support to this case, you may complete the attached Notification Response Form and either mail to the Planning & Development Services Department (address listed at the top of notice) or email (e-mail listed at the bottom of the notice). You are encouraged to follow the requested action through final approval because changes are often made during the review process. Please contact the Planning and Development Services Department at (817) 748-8621 or mburnett@ci.southlake.tx.us if you have any questions. Thank you. CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817)748-8621 www.cityofsouthlake.com Planning and Zoning Commission Thursday, April 17,2025 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZA25-0018: Zoning Change, Development Plan, and Site Plan for Liberty Commons. Meeting Date: April 17, 2025 Fill out: Owner: _____________________________ Address: ____________________________ City, State, Zip Code: __________________ PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed application referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s). Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone : (817) 748-8621 Residential Planned United Development District- Land Use and Development Regulations and Open Space Management Plan for the 10.72 acre development known as Carroll Crossing Residential Southlake, Texas 17 March 2025 Case # ZA25-00XX Sage Group, Inc. This Residential Planned Unit Development shall abide by the all conditions of the City of Southlake Comprehensive Zoning Ordinance No. 480, as amended, as it pertains to the “SF-20A” Single-Family Residential zoning district and the City of Southlake Subdivision Ordinance No. 483, as amended, with the following exceptions: Lot Width: Lot widths shall be measured along the Front Yard setback line for each lot as indicated on the Zoning Development Plan. Lot Coverage: All buildings or structures shall have a maximum lot coverage not exceeding forty five percent (45%) of the lot area, except the sum total of accessory buildings shall not exceed 600 square feet. Setbacks: Front Yard: 30’ Side Yard: 10’ Street Side Yard: 15’ Rear Yard: 30’ The following regulations shall apply to the lots: Minimum House Size: All new houses constructed shall be a minimum of 3,500 s.f. in floor area. Streets: A 31’ B-B pavement section with standard 6” curb & 50’ Private Street R.O.W. shall be provided along the frontage of all residential lots. The cul-de-sac shall be the standard 100’ B-B diameter paving, in a one hundred ten (110’) foot diameter Private Street ROW. Sidewalks: A minimum 5’ wide concrete sidewalk shall be required along the internal street frontage of all Residential Lots. Sidewalks and Trails within the Open Space Lots shall be as shown on the Zoning Development Plan and Pedestrian Access Plan. Side and rear lot lines shall be configured as shown on the Development Plan. This development shall have one primary, gated vehicular entry from Peytonville Avenue, with an additional resident-only access point meeting the fire safety requirements to/from Players Circle (as shown on the Development Plan) and private streets, built to standard city specifications. Open Space Management Plan: Intended Usage: The common open space areas of the project are intended for the quiet enjoyment of the residents within the development. The HOA will maintain all open space areas. All sidewalks and trails are intended for recreational pedestrian traffic, shall be kept in good condition, and accessible to the residents. Any significant changes to the plan must be approved by the City Council. All Common Open Space shall be owned and maintained by a Homeowners Association (HOA), to be established for the development. All other areas shall be the responsibility of the individual property owners, including the front yards a nd required streetscape trees of the residential lots. All property owners shall be required to be a member of the HOA. Dues assessments, required for the maintenance of the common areas and other HOA activities, shall be mandatory. The HOA, through a resident Board of Directors, shall be responsible for the maintenance and operation of the protected open space within the development , either directly or through a third-party management company. No full-time employees are contemplated to be necessary. The expenses required to maintain the common areas at a quality level shall be estimated annually by the HOA Board, and dues shall be determined and assessed on each property owner in an equitable fashion at such a rate as necessary to ma intain such a level of quality. Authority to enforce these requirements, and to place a lien on the property if such dues are not paid, shall be in the form of written Deed Restrictions and Covenants, agreed to by all property owners in the HOA at purchase, and shall run with the land. Provisions shall be made, in the HOA bylaws and Deed Restrictions, that in the unlikely event the HOA fails to maintain all or a portion of the protected open space in reasonable order and condition, the City of Southlake may, but is not required to, assume responsibility for its maintenance and take corrective action, including the provision of extended maintenance. The costs of such maintenance may be charged to the HOA or individual property owners that make up the HOA, and may include administrative costs and penalties which shall become a lien on all property in the development. Page 1 of 2 Detailed Site Plan (SP-1) District- Land Use and Development Regulations for Carroll Crossing- Commercial, on a 4.405 acre parcel on Southlake Blvd., just west of Peytonville Avenue Southlake, Texas Zoning Case #: ZA25-00XX Prepared by Sage Group, Inc. 17 March 2025 This Detailed Site Plan (SP-1) district shall abide by the all conditions of the City of Southlake Comprehensive Zoning Ordinance No. 480, as amende d, and the City of Southlake Subdivision Ordinance No. 483, as amended. All previous conditions of approval in Ordinance No. 480-744 remain in effect. Permitted Uses: This property shall be subject to the development regulations for the “O-1” Office District on Lots 1-4; and “C-1” Commercial District, including Restaurants, Tea Rooms, Cafeterias, Fast Food and “take out” food Restaurants including Drive-thru without size limitation, on Lot 5; and all other applicable regulations, with the following exceptions: Development Regulations: 1. Minimum Side Building Setbacks shall be fifteen (15’) feet, except that setbacks along internal property lines shall not be required. 2. Buffer Yards along internal lot lines shall not be required. 3. The maximum impervious coverage for the overall “SP-1” boundary shall be 80%; however, the maximum impervious coverage requirement shall not apply to individual lots within the boundary. 4. A shared parking, cross-access easement and shared maintenance agreement shall be required. Required parking for all built uses shall be provided within the “SP-1” boundary; parking requirements for individual lots shall not apply. 5. Parking Space Requirements: All Uses: One (1) space for each two-hundred twelve (212) square feet of Net Leasable area. Page 2 of 2 6. Dumpster Enclosure Location: Dumpster enclosures shall be permitted as shown on the Site Plan. 7. A maximum of one (1) ground mounted monument sign shall be allowed per building/ site. Open Space Management Plan: Intended Usage: The common open space areas of the project are intended for the quiet enjoyment of the occupants within the development. All sidewalks are intended for pedestrian traffic, shall be kept in good condition, and accessible to the occupants and customers. Any significant changes to the plan must be approved by the City Council All Open Space shall be maintained by the property owners or the Property Owners Association (POA). All property owners shall be required to be a member of the POA. Dues assessments, required for the maintenance of the open space areas and other POA activities, shall be mandatory. The POA shall be responsible for the maintenance and operation of the open space within the development. The expenses required to maintain the common areas at a quality level shall be estimated annually by the POA Board, and dues shall be determined and assessed on each property owner in an equitable fashion at such a rate as necessary to maintain such a level of quality. Authority to enforce these requirements, and to place a lien on the property if such dues are not paid, shall be in the form of written Deed Restrictions and Covenants, agreed to by all property owners at purchase, and shall run with the land. Provisions shall be made, in the POA bylaws and Deed Restrictions, that in the unlikely event the POA fails to maintain all or a portion of the open space in reasonable order and condition, the City of Southlake may, but is not required to, assume responsibility for such maintenance and take corrective action, including the provision of extended maintenance. The costs of such maintenance may be charged to the POA or individual property owners that make up the POA, and may include administrative costs and penalties which shall become a lien on all property in the development. SOUTHLAK E B L V D KILLDEERCTINDIAN PAINTBRUSH WAYSTARLINGCT STONEBURYDRSWALLOW CTCORPORATE CIRPEYTONVILLE AVEPEYTONVILLE AVEPLAYERS CIRMEADOWLARK LN1 2 6 10 23 22 21 20 19 18 17 14 272628 12 7 9 8 13 2425 16 15 11 3 5 41000 1001 SPO Map ZA25-0018 ® 0 350 700175 Feet 200 S Peytonville Ave, 1963 W Southlake Blvd Legend City Parcels Right Of Way City Limit Case Parcel(s) dissolvedParcel 200 Foot Buffer 300 Foot Buffer bufferCut Parcels Within Buffer rowClip DET. POND41,305 s.f.OPEN SPACE 67,245 s.f.620,397 s.f.720,006 s.f.924,574 s.f.820,001 s.f.Gated Residential Entry21'200'100'OPEN SPACE 19,216 s.f.Existing Zoning: C-2L.U.D.=Retail Commercial24' Access EasementAccess gatesExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: SP-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office District24'165'1026,784 s.f.1126,004 s.f.1220,014 s.f.1320,130 s.f.1423,072 s.f.420,031 s.f.520,119 s.f.321,950 s.f.220,000 s.f.123,014 s.f.100'100'122'200'165' 200' 200'200'100'110'100'112'R55'R50'Existing Zoning: C-3L.U.D.=General Commercial 20' Type "O" Bufferyard 24' Fire Lane 24' Fire Lane24' Fire Lane20' Type "O" Bufferyard10' Type "B" Bufferyard10' Type "B" Bufferyard 10' Type "B" Bufferyard 24' Fire Lane 24' Fire Lane10' Type "B" Bufferyard10' Type "B" Bufferyard10' Type "B" Bufferyard 40'EXISTING SIDEWALKEXISTING SIDEWALKLot 5 /Bldg 5RestaurantOne Story3,375 s.f.Lot 4 /Bldg. 4One Story9,600 s.f.(under roof)Lot 3 / Bldg. 3One Story7,080 s.f.(under roof)Lot 1 / Bldg.1One Story7,800 s.f. (under roof)Lot 2 / Bldg. 2One Story5,700 s.f.(under roof)Existing Zoning: C-3L.U.D.=General Commercial CONTINUOUS LANDSCAPE SCREENING (TYP)75'SSMHSSMHSSMHSSMHHYDHYDHYDHYDHYDPROP. 2-5x3MBCEX. 2-5x3MBCEX. 2-5x3MBC"Y" INLETCURB INLET24" RCP8" WATER8" SEWER8" WATER8" SEWER8" SEWER 8" WATER8" WATER 12" x 8" WATERCONNECTION12" x 8" WATERCONNECTIONOUTLET CONTROLSTRUCTURESSMHCONNECT TOEXISTING SSMH24" RCPBLDG. 4 TOCONNECT TOEXISTING SSMHEX. 8" SEWEREX. 8"SEWERWWWWWWWWWWW W W W W W W W W WWWWWWWWWWWWWWWWWWWWWWW W W W WSSMH EX. 8" SEWER8" SEWEREX. 12" WATERSSMHCURB INLET24" RCPCURBINLET24" RCPHYD8" WATER 2 - CURB INLET2 - 24" RCP8" x 8" WATERCONNECTIONSSMHEX. 8" WATER EX.HYDCONNECT TO EX.8" STUB.8" WATEREX.HYDDETENTION POND AND OUTLET CONTROLSTRUCTURE TO LIMIT PROPOSED FLOWRATES TO OR BELOW EXISTING FLOWS.C1PRELIMINARY WATER, SEWER AND DRAINAGE PLAN CARROLL CROSSING SOUTHLAKE, TEXAS C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC. 112 Keystone Drive Southlake, Texas 76092 817-337-8899 (Office) PREPARED FOR:OLERIO HOMES Contact: Lou Olerio 6310 Lemmon Avenue, Suite 202 Dallas, Texas 75209 (469) 853-2039NOTES:1.ALL SEWER LINE SHALL BE SDR-35 PVC.2.ALL WATER PIPE SHALL BE SDR-18 C-900.3.ALL CONSTRUCTION SHALL BE IN CONFORMANCEWITH THE CITY OF SOUTHLAKE STANDARDS FORPUBLIC WORKS CONSTRUCTION.4.ALL SEWER SERVICES ARE PRIVATE.5.ALL WATER SERVICES ARE PRIVATE FROM THEBUILDING TO THE METER AND PUBLIC FROM THEMETER TO THE WATER MAIN.6.ALL WATERLINE SHALL HAVE A MINIMUM 2' VERTICALCLEARANCE FROM DRAINAGE STRUCTURES ANDSEWER SERVICES.7.THE LOCATION OF EXISTING WATER AND SANITARYSEWER UTILITIES ARE APPROXIMATE. FINALENGINEERING REVIEW AND COORDINATION MAYRESULT IN SOME MINOR ADJUSTMENTS TO THISPLAN.8.ALL WATERLINE SHALL BE INSTALLED WITH AMINIMUM COVER OF 42" UNLESS OTHERWISE NOTEDOR EXPLICITLY APPROVED BY THE CITY ENGINEER.9.FIRE HYDRANTS SHALL BE PLACED WITH STEAMERNOZZLE AT LEAST 3' BEHIND BACK OF CURB.10.PRIVATE SANITARY SEWER SERVICES NEED APLUMBING PERMIT AND MUST BE INSPECTED BYBUILDING INSPECTIONS PRIOR TO BURIAL.LEGENDWPROP. WATER LINEPROP. SEWER LINEEXIST. WATER MAINPROP. FIRE HYDRANTPROP. CULVERTEXIST. SEWER MAINPROP. SEWER MANHOLE0603060120 C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC. 112 Keystone Drive Southlake, Texas 76092 817-337-8899 (Office) PREPARED FOR:OLERIO HOMES Contact: Lou Olerio 6310 Lemmon Avenue, Suite 202 Dallas, Texas 75209 (469) 853-2039 W. SOUTHLAKE BOULEVARDW. SOUTHLAKE BOULEVARDDET. POND41,305 s.f.OPEN SPACE 67,245 s.f.620,397 s.f.720,006 s.f.924,574 s.f.820,001 s.f.Gated Residential Entry21'200'100' S. PEYTONVILLE AVENUE PLAYERS CIRCLE OPEN SPACE 19,216 s.f.S. PEYTONVILLE AVENUE Existing Zoning: C-2L.U.D.=Retail Commercial24' Access EasementAccess gatesExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: SP-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office DistrictExisting Zoning: O-1L.U.D.=Office District24'165'1026,784 s.f.1126,004 s.f.1220,014 s.f.1320,130 s.f.1423,072 s.f.420,031 s.f.520,119 s.f.321,950 s.f.220,000 s.f.123,014 s.f.100'100'122'200'165' 200' 200'200'100'110'100'112'R55'R50'W. SOUTHLAKE BOULEVARDW. SOUTHLAKE BOULEVARDExisting Zoning: C-3L.U.D.=General Commercial 20' Type "O" Bufferyard 20' Type "O" Bufferyard10' Type "B" Bufferyard10' Type "B" Bufferyard 10' Type "B" Bufferyard10' Type "B" Bufferyard10' Type "B" Bufferyard10' Type "B" Bufferyard5' SIDEWALK (TYP)40'EXISTING SIDEWALKEXISTING SIDEWALKExisting Zoning: C-3L.U.D.=General Commercial CONTINUOUS LANDSCAPE SCREENING (TYP)75'5' SIDEWALK (TYP)C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC. 112 Keystone Drive Southlake, Texas 76092 817-337-8899 (Office) PREPARED FOR:OLERIO HOMES Contact: Lou Olerio 6310 Lemmon Avenue, Suite 202 Dallas, Texas 75209 (469) 853-2039NOTE:MAX CAPACITY OF 2-5X3 MBC AT 1% SLOPE IS:Q = 2 x (C=1630) *S^0.5Q = 326 CFSMAX Q (des) = 278 CFS C I V I L E N G I N E E R I N G TBPE No. F-003116 DEOTTE, INC. 112 Keystone Drive Southlake, Texas 76092 817-337-8899 (Office) PREPARED FOR:OLERIO HOMES Contact: Lou Olerio 6310 Lemmon Avenue, Suite 202 Dallas, Texas 75209 (469) 853-2039 W. SOU T H L A K E B O U L E V A R D W. SOU T H L A K E B O U L E V A R D S. PEYTONVILLE AVENUEPLAYERS CIRCLEExisting Zoning: C-3L.U.D.=General Commercial20' Ty p e " O " B u f f e r y a r d 24' Fire Lane24' Fire La n e 24' Fire Lane 20' Type " O " B u f f e r y a r d 10' Type "B" Bufferyard 10' Type "B" Bufferyard10' Type "B" Bufferyard24' Fire Lane24' Fire Lane 10' Type "B" Bufferyard10' Type "B" Bufferyard10' Type "B" BufferyardS. PEYTONVILLE AVENUEExisting Zoning: C-2 L.U.D.=Retail Commercial 30' 30' 9'18'22' 18'9'9' 5'18'24' 24' 24' 24' 24' 2 4 ' R 3 0 'R30'24' 13' R30'R30'R 3 0 ' 5' SIDEWALK (TYP) 10' 11' R3 0 'R54' R30'R54'R54'R54' 40'136'16' 15' 15' 15' 15'11'40'39' 22'40' EXISTING SIDEWALK EXISTING SIDEWALK Lot 5 / Bldg 5 Restaurant One Story 3,375 s.f. Lot 4 / Bldg. 4 One Story 9,600 s.f. (under roof) Lot 3 / Bldg. 3 One Story 7,080 s.f. (under roof)Lot 1 / Bldg.1 One Story 7,800 s.f. (under roof) Lot 2 / Bldg. 2 One Story 5,700 s.f. (under roof)Existing Zoning: C-3L.U.D.=General Commercial50' BU I L D I N G SETBA C K 50' CONTINUOUS LANDSCAPE SCREENING (TYP)52'71' 80'63'100'93'50' BUILDING SETBACK50'84'96'R30'75' 427' 5' SIDEWALK (TYP)R54'Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: SP-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District8'22'8'Legend Existing Saved Tree Interior LandscapeCanopy Tree - 4" Interior Landscape Accent Tree - 6' Height Min. Interior Landscape Shrub (& Parking) - 3 Gal. Min. Groundcover - 4" Containers Min. (12" O.C.) Seasonal Color - 4" Containers Min. Bufferyard 17 MAR 25 0 100'200'400' 1" = 100' Southlake, Tarrant County, Texas Carroll CrossingLandscape Plan SAGE GROUP, INC. Master Planning Urban Design Architecture Landscape Architecture 1130 N. Carroll Ave., Ste. 200 Southlake, Texas 76092 TEL. 817-424-2626 Planner: Case #ZA24-0059 GENERAL NOTES 1.MECHANICAL EQUIPMENT SHALL BE SCREENED FROM VIEW. 2.ALL EXTERIOR LIGHTING SHALL BE IN ACCORDANCE WITH LIGHTING ORDINANCE. 3.ALL SIDEWALKS TO BE MONOLITHIC BROOM FINISH. 4.ALL PARKING AREAS TO BE ALL WEATHER SURFACE. Engineer: Deotte, Inc. 420 Johnson Rd., ste. 303 Keller, TX 76248 TEL. 817-337-8899 Contact: Richard DeOtte, P.E. Surveyor: Blue Sky Surveying and Mapping 11015 Midway Road Dallas, TX 75229 TEL. 214-358-4500 Eaves, WR Survey, Abstract 500, Tracts 3D & 3C02 Owner: Carroll Crossing, LCC 6310 Lemmon Ave Ste 202 Dallas, Texas 75209 Developer: Paul Moss TAK Enterprises, Inc. 8821 Davis Blvd. #220 Keller, Texas 76248 TEL. 817-431-5626 W. SOU T H L A K E B O U L E V A R D W. SOU T H L A K E B O U L E V A R D S. PEYTONVILLE AVENUEPLAYERS CIRCLEExisting Zoning: C-3L.U.D.=General Commercial20' Ty p e " O " B u f f e r y a r d 24' Fire Lane24' Fire L a n e 24' Fire Lane 20' Type " O " B u f f e r y a r d 10' Type "B" Bufferyard 10' Type "B" Bufferyard10' Type "B" Bufferyard24' Fire Lane24' Fire Lane 10' Type "B" Bufferyard10' Type "B" Bufferyard10' Type "B" BufferyardS. PEYTONVILLE AVENUEExisting Zoning: C-2 L.U.D.=Retail Commercial 5' SIDEWALK (TYP) EXISTING SIDEWALK EXISTING SIDEWALK Lot 5 / Bldg 5 Restaurant One Story 3,375 s.f. Lot 4 / Bldg. 4 One Story 9,600 s.f. (under roof) Lot 3 / Bldg. 3 One Story 7,080 s.f. (under roof)Lot 1 / Bldg.1 One Story 7,800 s.f. (under roof) Lot 2 / Bldg. 2 One Story 5,700 s.f. (under roof)Existing Zoning: C-3L.U.D.=General Commercial50' BU I L D I N G SETBA C K 50' 50' BUILDING SETBACK 5' SIDEWALK (TYP) Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: SP-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Less R.O.W - - - Trees Saved Trees Trees to be Altered Total Trees Total Trees 1 20 21 Trees Net of R.O.W. 1 20 21 150,512 s.f. ≈9,083 s.f. -->6.03% ≈452 s.f. --> 4.98% ≈8,631 s.f. --> 95.02% ≈9,083 s.f. -->100.00% Tree Canopy Coverage Total site area Total existing canopy Preserved tree canopy Preserved tree canopy (green) Removed tree canopy (red) 17 MAR 25 0 20'40'80' 1" = 20' Southlake, Tarrant County, Texas Tree Conservation Plan SAGE GROUP, INC. Master Planning Urban Design Architecture Landscape Architecture 1130 N. Carroll Ave., Ste. 200 Southlake, Texas 76092 TEL. 817-424-2626 Planner: Case #ZA24-0059 Carroll Crossing Engineer: Deotte, Inc. 420 Johnson Rd., ste. 303 Keller, TX 76248 TEL. 817-337-8899 Contact: Richard DeOtte, P.E. Surveyor: Blue Sky Surveying and Mapping 11015 Midway Road Dallas, TX 75229 TEL. 214-358-4500 Eaves, WR Survey, Abstract 500, Tracts 3D & 3C02 Owner: Carroll Crossing, LCC 6310 Lemmon Ave Ste 202 Dallas, Texas 75209 Developer: Paul Moss TAK Enterprises, Inc. 8821 Davis Blvd. #220 Keller, Texas 76248 TEL. 817-431-5626 W. SOU T H L A K E B O U L E V A R D W. SOU T H L A K E B O U L E V A R D DET. POND 41,305 s.f. OPEN SPACE 67,245 s.f. 6 20,397 s.f. 7 20,006 s.f. 9 24,574 s.f. 8 20,001 s.f. Gated Residential Entry 21'200'100'30' FRONT SETBACK 30' REAR SETBACK 10' SIDE SETBACK50'R.O.W.S. PEYTONVILLE AVENUEPLAYERS CIRCLEOPEN SPACE 19,216 s.f.S. PEYTONVILLE AVENUEExisting Zoning: C-2 L.U.D.=Retail Commercial 18'30'F-F50'ROW24' Access Easement Access gates 24'Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: SP-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District 24'165'10 26,784 s.f. 11 26,004 s.f. 12 20,014 s.f. 13 20,130 s.f. 14 23,072 s.f. 4 20,031 s.f. 5 20,119 s.f. 3 21,950 s.f. 2 20,000 s.f. 1 23,014 s.f. 50' R.O.W.100'100'122'200'165'200'200'200'100'110'100'112'10' SIDE SETBACK10' SIDE SETBACK10' SIDE SETBACK30' FRONT SETBACK30' FRONT SETBACK30' FRONT SETBACK10' SI D E S E T B A C K 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK 30' REAR SETBACK 30' REAR SETBACK30' REAR SETBACK30' FRONT SETBACK30' FRONT SETBACK 30' FRONT SETBACK 15' STREET SIDE SETBACK18'R55'R50'W. SOU T H L A K E B O U L E V A R D W. SOU T H L A K E B O U L E V A R D DET. POND 41,305 s.f. OPEN SPACE 67,245 s.f. 6 20,397 s.f. 7 20,006 s.f. 9 24,574 s.f. 8 20,001 s.f. 30' FRONT SETBACK 30' REAR SETBACK 10' SIDE SETBACKS. PEYTONVILLE AVENUEPLAYERS CIRCLEOPEN SPACE 19,216 s.f.S. PEYTONVILLE AVENUEExisting Zoning: C-2 L.U.D.=Retail Commercial Access gates Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: SP-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District 10 26,784 s.f. 11 26,004 s.f. 12 20,014 s.f. 13 20,130 s.f. 14 23,072 s.f. 4 20,031 s.f. 5 20,119 s.f. 3 21,950 s.f. 2 20,000 s.f. 1 23,014 s.f.10' SIDE SETBACK10' SIDE SETBACK10' SIDE SETBACK30' FRONT SETBACK30' FRONT SETBACK30' FRONT SETBACK10' SI D E S E T B A C K 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK 30' REAR SETBACK 30' REAR SETBACK30' REAR SETBACK30' FRONT SETBACK30' FRONT SETBACK 30' FRONT SETBACK 15' STREET SIDE SETBACKFence Legend 8' Retain/ Repair/ Replace Existing Wood Fence 8' Wood Fence 6' Masonry Wall 6' Decorative Iron Fence 17 MAR 25 0 100'200'400' 1" = 100' Southlake, Tarrant County, Texas Carroll CrossingDevelopment Plan Eaves, WR Survey, Abstract 500, Tracts 3D & 3C02 SAGE GROUP, INC. Master Planning Urban Design Architecture Landscape Architecture 1130 N. Carroll Ave., Ste. 200 Southlake, Texas 76092 TEL. 817-424-2626 Planner: Case #ZA25-00XX SP-1 & O-1 RPUDRetail- Commercial & Med Density Residential Number of Residential Lots Existing Zoning Open Space (s.f.) Residential Site Data Summary Chart Proposed Zoning Existing Land Use 21,864 Average Res Lot Size (s.f.) Gross Density (Dwelling units per gross ac) 87,7101.3014 Notes: 1.All sidewalks are concrete. 2.Entrances & exits to buildings 3.All sidewalks are 5' wide. Engineer: Deotte, Inc. 420 Johnson Rd., ste. 303 Keller, TX 76248 TEL. 817-337-8899 Contact: Richard DeOtte, P.E. Open Space % 18.78% Gross Acreage 10.72 FENCE AND WALL DIAGRAM Not To Scale Developer: Paul Moss TAK Enterprises, Inc. 8821 Davis Blvd. #220 Keller, Texas 76248 TEL. 817-431-5626 Owner: Carroll Crossing, LCC 6310 Lemmon Ave Ste 202 Dallas, Texas 75209 Surveyor: Blue Sky Surveying and Mapping 11015 Midway Road Dallas, TX 75229 TEL. 214-358-4500 W. SOU T H L A K E B O U L E V A R D W. SOU T H L A K E B O U L E V A R D DET. POND 41,305 s.f. OPEN SPACE 67,245 s.f. 6 20,397 s.f. 7 20,006 s.f. 9 24,574 s.f. 8 20,001 s.f. Gated Residential Entry 21'200'100'30' FRONT SETBACK 30' REAR SETBACK 10' SIDE SETBACKS. PEYTONVILLE AVENUEPLAYERS CIRCLEOPEN SPACE 19,216 s.f.S. PEYTONVILLE AVENUEExisting Zoning: C-2 L.U.D.=Retail Commercial 24' Access Easement Access gates Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: SP-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District Existing Zoning: O-1 L.U.D.=Office District 24'165'10 26,784 s.f. 11 26,004 s.f. 12 20,014 s.f. 13 20,130 s.f. 14 23,072 s.f. 4 20,031 s.f. 5 20,119 s.f. 3 21,950 s.f. 2 20,000 s.f. 1 23,014 s.f.100'100'122'200'165'200'200'200'100'110'100'112'10' SIDE SETBACK10' SIDE SETBACK10' SIDE SETBACK30' FRONT SETBACK30' FRONT SETBACK30' FRONT SETBACK10' SI D E S E T B A C K 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK 10' SIDE SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK30' REAR SETBACK 30' REAR SETBACK 30' REAR SETBACK30' REAR SETBACK30' FRONT SETBACK30' FRONT SETBACK 30' FRONT SETBACK 15' STREET SIDE SETBACKR55'R50'Less R.O.W - - - Trees Saved Trees Trees to be Altered Total Trees Total Trees 89 221 310 Trees Net of R.O.W. 89 221 310 658,919 s.f. ≈131,351 s.f. -->19.93% ≈50,279 s.f. --> 38.28% ≈81,072 s.f. --> 61.72% ≈131,351 s.f. -->100.00% Tree Canopy Coverage Total site area Total existing canopy Preserved tree canopy Preserved tree canopy (green) Removed tree canopy (red) 17 MAR 25 0 20'40'80' 1" = 20' Southlake, Tarrant County, Texas Tree Conservation Plan SAGE GROUP, INC. Master Planning Urban Design Architecture Landscape Architecture 1130 N. Carroll Ave., Ste. 200 Southlake, Texas 76092 TEL. 817-424-2626 Planner: Case #ZA24-0059 Carroll Crossing Engineer: Deotte, Inc. 420 Johnson Rd., ste. 303 Keller, TX 76248 TEL. 817-337-8899 Contact: Richard DeOtte, P.E. Surveyor: Blue Sky Surveying and Mapping 11015 Midway Road Dallas, TX 75229 TEL. 214-358-4500 Eaves, WR Survey, Abstract 500, Tracts 3D & 3C02 Owner: Carroll Crossing, LCC 6310 Lemmon Ave Ste 202 Dallas, Texas 75209 Developer: Paul Moss TAK Enterprises, Inc. 8821 Davis Blvd. #220 Keller, Texas 76248 TEL. 817-431-5626 17 MAR 25 0 20'40'80' 1" = 20' Southlake, Tarrant County, Texas Tree Conservation Plan SAGE GROUP, INC. Master Planning Urban Design Architecture Landscape Architecture 1130 N. Carroll Ave., Ste. 200 Southlake, Texas 76092 TEL. 817-424-2626 Planner: Case #ZA24-0059 Carroll Crossing Engineer: Deotte, Inc. 420 Johnson Rd., ste. 303 Keller, TX 76248 TEL. 817-337-8899 Contact: Richard DeOtte, P.E. Surveyor: Blue Sky Surveying and Mapping 11015 Midway Road Dallas, TX 75229 TEL. 214-358-4500 Eaves, WR Survey, Abstract 500, Tracts 3D & 3C02 Owner: Carroll Crossing, LCC 6310 Lemmon Ave Ste 202 Dallas, Texas 75209 Developer: Paul Moss TAK Enterprises, Inc. 8821 Davis Blvd. #220 Keller, Texas 76248 TEL. 817-431-5626