Loading...
Item 8 - Staff ReportCase No. ZA25-0014 S T A F F R E P O R T March 28, 2025 CASE NO: ZA25-0014 PROJECT: Zoning Change and Development Plan – 500 E. Bob Jones Rd. EXECUTIVE SUMMARY: BridgeRock Developments, LLC., on behalf of Sanford and Zoe Sexhus, is requesting approval of a Zoning Change and a Development Plan for 500 E. Bob Jones Rd., on property described as Lot 1, William Phillips No. 1017 Addition, an addition to the City of Southlake, Denton County, Texas. Current Zoning: “AG” Agriculture District. Requested Zoning: “SF-1A” Single Family Residential Zoning District. SPIN Neighborhood #1. DETAILS: This project is located on approximately 8.38 acres on the north side of E. Bob Jones Rd. adjacent along Corps of Engineers Property. The purpose of this request is to seek approval for a zoning change and concept plan for 7 residential lots. The lots will range in size from a minimum of approximately 43,600 square feet to a maximum of approximately 52,900 square feet. Side Yard Setback Reduction Requested: - The Zoning Ordinance No. 480, as amended, permits the reduction of a side yard setback adjacent to a street from the minimum 40’ to a minimum 20’, with approval of the P & Z/City Council. Applicant is requesting a 20’ side yard building setback along the street for the corner lots at the intersection of E. Bob Jones Rd. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Approval ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Development Review Summary No. 1, dated March 7, 2025 (D) Surrounding Property Owners Map & Responses SPIN Report PowerPoint Presentation Narrative Development Regulations Plans Department of Planning & Development Services Case No. ZA25-0014 STAFF CONTACT: Cyndi Cheng (817) 748-8269 Jenny Crosby (817) 748-8195 Case No. Attachment A ZA25-0014 Page 1 BACKGROUND INFORMATION OWNER: Sanford and Zoe Sexhus APPLICANT: Bridgerock Developments, LLC PROPERTY SITUATION: 500 East Bob Jones Road LEGAL DESCRIPTION: Lot 1, William Phillips No. 1017 Addition LAND USE CATEGORY: Low Density Residential CURRENT ZONING: “AG” Agricultural District PROPOSED ZONING: “SF-1A” Single Family Residential HISTORY: - The property was annexed in 1988. - November 12, 2019; Plat Showing filed for records for a single lot of 8.41 acres (ZA19-0047) SOUTHLAKE COMPREHENSIVE PLAN: Consolidated Future Land Use Plan The future land use designation for the site is “Low Density Residential”. Low Density Residential Purpose and Definition: The purpose of the Low Density Residential land use category is to provide for and to protect low intensity detached single‐family residential development that promotes the openness and rural character of Southlake. The Low Density Residential category is for detached single‐family residential development at a net density of one or fewer dwelling units per acre. Net density is the number of dwelling units per net acre, which excludes acreage in all rights‐of‐way, easement, and lots designated for public or private streets. Other suitable activities are those permitted in the Public Parks / Open Space and Public / Semi‐Public categories. The Low Density Residential category encourages the openness and rural character of the City of Southlake. Master Pathways Plan The Master Pathways Plan calls for a <8’ sidewalk along E. Bob Jones Rd. A minimum 5’ sidewalk is required along E. Bob Jones Rd. and all internal street frontages. TRANSPORTATION ASSESSMENT: The property accesses E. Bob Jones Rd. which is designated as a 2 lane local street with a minimum 50’ right of way. TREE PRESERVATION: The proposed existing tree cover preservation complies with the existing tree cover preservation requirements of the Tree Preservation Ordinance 585-E. There is 7.38% of existing tree cover on the property and a minimum of 70% of the tree cover is required to be preserved. A total of 90.77% is proposed to be preserved and 9.23% to be removed. Case No. Attachment A ZA25-0014 Page 2 UTILITIES: An 6-inch water line and fire hydrant will be installed to serve the lots, extended from the existing 6” water line located along E. Bob Jones Rd. DRAINAGE: Property currently drains northeast and east toward Lake Grapevine and Corp of Engineers property. The proposed drainage plan does not appear to change this general course of flow CITIZEN INPUT: A SPIN meeting was held on March 25, 2025. STAFF COMMENTS: Attached is Development Plan Review Summary No. 1, dated March 7, 2025. Case No. Attachment A ZA25-0014 Page 3 Case No. Attachment A ZA25-0014 Page 4 DEVELOPMENT PLAN REVIEW SUMMARY Case No.: ZA25-0014 Review No.: One Date of Review: 03/07/25 Project Name: Concept Plan – 500 E Bob Jones Rd APPLICANT: OWNER: Jody Boyd Sexhus, Sanford C & Zoe N 404 N. Oak Street 500 E. Bob Jones Road Roanoke, TX 76262 Southlake, TX 76092 Phone: 214-727-1110 Phone: 817-917-7929 Email: jboyd@bridgerockllc.com Email: n2224z@att.net CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 02/27/25 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT WAYNE POWELL AT (817) 748-8281. 1. Provide a written narrative describing the use, operation, phasing, infrastructure to be provided, etc. The narrative needs to include justification for the side yard reductions. 2. Place the City case number “ZA25-0014" in the lower right corner for ease of reference. 3. The Zoning Ordinance No. 480, as amended, permits a reduction of a side yard adjacent to a street from the minimum 40’ to a minimum 20’, with approval of the P & Z/City Council. Applicant is requesting a 20’ side yard building setback along the street for the lots at the intersection of E. Bob Jones Rd. 4. Please amend the Zoning and Development Application from “Development Plan” to “Concept Plan”. 5. Label the adjacent properties and properties across adjoining R.O.W.'s with owner's name (if not platted) or lot/block/subdivision (if platted), existing zoning, and land use map designation ("L.U.D.=_____") 6. Label the distance between buildings and distance from building to property lines 7. Please note which structures will be demolished and which will stay. Some structures and buildings may become non-conforming structures if zoning is approved and/or following future subdivision platting. 8. Show and label the width and type of surface for all sidewalks. Provide sidewalks and/or trails in compliance with Subdivision Ordinance No. 483, as amended and the Master Pathways Plan. A minimum 5’ sidewalk is required along the frontage of E. Bob Jones Rd. and each lot along the new street. 9. Provide a report showing that all lots are suitable for septic installation. (See section 33 of the Zoning Ordinance and the Tarrant County Department of Health standards and regulations). Case No. Attachment A ZA25-0014 Page 5 10. Show the location of the existing on-site sanitary sewer facility and note whether it is to remain or be decommissioned. 11. Show the location, type, and height of all walls, fences, and screening devices. Note whether existing ones are to remain or be removed and any that are proposed. 12. Show and label any existing easements on the property including the Grapevine Lake Flowage Easement. Case No. Attachment A ZA25-0014 Page 6 Tree Conservation/Landscape Review 1. Trees #589, 590 and 595 will most likely be within a future house pad area and be required to be mitigated if shown to be preserved. It is probably best to revise the Tree Conservation Plan to show them to be altered or as Marginal. * The proposed existing tree cover preservation complies with the existing tree cover preservation requirements of the Tree Preservation Ordinance 585-E. there is 7.38% of existing tree cover on the property and a minimum of 70% of the tree cover is required to be preserved. A total of 90.77% is proposed to be preserved and 9.23% to be removed. * Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 – Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site Minimum percentage of the existing tree cover to be preserved* 0% – 20% 70% 20.1 – 40% 60% 40.1% - 60% 50% 60.1% - 80% 40% 80.1% - 100% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights-of-way as approved by City Council. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. * Indicates informational comment. # Indicates required items comment. E-mail: kmartin@ci.southlake.tx.us Keith Martin Landscape Administrator Phone: (817) 748-8229 Case No. Attachment A ZA25-0014 Page 7 Public Works/Engineering Review GENERAL COMMENTS: 1. The minimum radius is 30’ along the firelane and at the proposed connection to Bob Jones. Label the radius along the firelane and at all intersections. 2. A 5’ sidewalk will be required along all street frontage 3. Show and label all proposed easements. *If the existing driveway is to remain in place for the existing residence and barn, a private access easement will be required on Lots 1 and 2. DRAINAGE COMMENTS: *Be aware that cross lot drainage will require the drainage flow to be captured within a closed system, whether it be a swale or storm pipe, and will be required to be located within a private drainage easement. *If detention is not being proposed then it shall be proven during construction plan submittal that there will be no adverse impacts. UTILITY COMMENTS: *The minimum radius for an 8” water line is 200’. Please ensure that the minimum radius is being met. * The septic system for the barn is shown to be located on both Lots 2 and 3. If this is to remain, the septic system will need to be relocated. Sandra Endy, P.E. Development Engineer Phone: (817) 748-8033 E-mail: sendy@ci.southlake.tx.us Case No. Attachment A ZA25-0014 Page 8 Fire Department Review FIRE HYDRANT COMMENTS: Hydrants required at maximum spacing for R-3 Occupancies is 400 feet for subdivisions with un-sprinklered homes. FIRE LANE COMMENTS: Fire access roads in residential subdivision must be at least 31 ft. back of curb to back of curb. (Standard street width) Fire apparatus access requires a minimum 30 foot inside turn radius and a minimum 54 foot outside turn radius Cul-de-Sacs must have 30 ft. inside turn radius and 50-foot radius (100-foot diameter) for approved turnaround. Lorenzo Chavez Fire Marshal Phone: (817) 748-8671 E-mail: lchavez@ci.southlake.tx.us Case No. Attachment A ZA25-0014 Page 9 General Informational Comments * Building permit(s) are required prior to commencement of any work. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * The applicant should be aware that prior to issuance of a building permit a Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Dedication Fee, Roadway Impact Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * In addition to the City of Southlake impact fees, please be aware that through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. * A preliminary plat must be approved prior to submitting a plat revision of a plat vacation and final plat. All plats must comply with the Subdivision Ord. No. 483, as amended. * The property owner developer must contact the US Postal Service to determine appropriate mail delivery methods and requirements. Case No. Attachment D ZA25-0014 Page 1 SURROUNDING PROPERTY OWNERS MAP & RESPONSES SPO # Owner Zoning Physical Address Acreage Response 1 Grapevine Lake, Corp of Engineers AG 8.30 2 JOHNSON, FRED AG 400 E BOB JONES RD 2.56 O 3 Grapevine Lake, Corp of Engineers AG 0.77 4 STUKEL, CATHY & DABBS, DANA L SF1-A 445 E BOB JONES RD 0.44 O 5 HIGGINBOTHAM, RHETT KEVAN & ANGELA STEPHANIE FAMILY TRUST SF1-A 435 E BOB JONES RD 0.00 NR 6 POULSEN, GEORGE H & NANCY K, CO-TRS, POULSEN FAMILY TRUST SF1-A 455 E BOB JONES RD 0.56 O 7 LOVE, MICHAEL G SF1-A 465 E BOB JONES RD 0.58 NR 8 JONES, SAMUEL D & SHERRY H SF1-A 475 E BOB JONES RD 0.53 O 1000 SEXHUS, SANFORD C & ZOE N AG 500 E BOB JONES RD 8.24 Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Seven (7) Responses Received within 300’: In Favor: 0 Opposed: 0 Undecided: 0 No Response: 8