Loading...
Item 9B - Proposed SignageMARRIOTT SITE ADDRFS� Marriott Contact: MC Project Manager: Tim Fenske MC Sales: James Peake g r o u p Building Better Brands 440.209.6200 800.627.4460 theMCgroup.com OWNER'S SCOPE OF WORK: - Owner to provide (1) primary circuit (120v) for EACH sign location. - Sign contractor is responsible for all secondary wiring. If primary is not present at time of install, the owner is responsible for making the final connection. - Owner is to provide unrestricted access to the area behind where each sign is located. - The access panel is to be approx. 24" x 36". - 5/8" plywood blocking is to be provided behind where each sign and lighting is to be installed. SIGN PACKAGE: (2) LETTERSETS - WEST & EAST ELEVATIONS (1) LETTERSET - NORTH ELEVATION (2) MONUMENT LETTERSETS PERMITTING DETAILS: .M CUSTOMER APPROVAL / SIGNATURE: SIGNATURE: DATE: MLWEST ELEVATION 13 60INCH STACKED `_ 71 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com ALL SIGN SIZES HAVE BEEN CALCULATED OFF SI773 S jm;'1 ARCHITECTURAL PRINTS AS SHOWN �ltli01311li1) J� 0. STRUCTU� T.O. PARAPET 173' 4" T.D.S ETE L 171' - 4" 6TH FLOOR 18D'-8" � 5TH FLOOR 150' - 0" 4TH FLOOR 139' - 4" 3RQ FLOOR h 128' - 8" >� 2NN FLO� 118'-0" 1ST FLOOR 1D0'-D-D" { CLIENT: D DELTA HOTELS TICKET NO.: DATE: REVISION HISTORY: 04/02/20 KW 584990 04/02/20 CLIENT SIGNATURE: Added plywood backing MARRIOTT PROJECT MANAGER: DESIGNER: JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ADDRESS: PAGE NO. 2 251 E SH 114 Southlake, TX 76092 ELECTRONIC FILE NAME: MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels_Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MLEAST ELEVATION 3 60INCH STACKED • • '' W 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com ALL SIGN SIZES HAVE BEEN CALCULATED OFF SI773 S jm;'1 ARCHITECTURAL PRINTS AS SHOWN �ltli01311li1) J� ICTUR FLOG 1 6Vr - 8" 1501 - 0" Ir F9-4 139-4" FLO 128' - $" FLOOR 118'-0" FLOOR 100'-0" CLIENT: D DELTA HOTELS TICKET NO.: DATE: REVISION HISTORY: 04/02/20 KW 584990 04/02/20 CLIENT SIGNATURE: Added plywood backing MARRIOTT PROJECT MANAGER: DESIGNER: JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ADDRESS: PAGE NO. 3 251 E SH 114 Southlake, TX 76092 ELECTRONIC FILE NAME: MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels_Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MFACE LIT CHANNEL LETTERS Scale: 01360 INCH STACKED •' •' 41 18'-8-1/4" 19'-9-1 /4" X - " PLYWOOD BACKING r----— — — — — — — — — — — — — i 161.6sgft I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 3'-3/8" I I I I I I I I I I 11 8"� HOTELS1 I I I 1-7/8" I I I I -------------I 10'-5-3/4" MC g r o u p Building Better Brands 14'-11-3/4" r 4'-6-1/2" 1 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com FACES: 3/16" #7328 white acrylic RETAINERS: 3/4" alum. retainers - painted black ('D' logo only) TRIMCAP: 1 " Black jewelite (DELTA HOTELS, UNDERSCORE, MARRIOTT) RETURNS: 5" deep .080 alum. - insides pre -painted White; Outsides painted Black BACKS: .063 Alum. - pre -painted White ILLUM.: GE White LED as required by manufacturer; Remote Power supplies EAST ELEVATION LETTERSET ONLY Letters to be pre -wired during a special trip. "D" logo, secondary wire to be brought out through the bottom of the logo so it can be accessed from the guest room rather than the roof WALL Not provided at this time MATERIAL: INSTALL: Letters to be mounted flush to fascia using lag bolts and shields as required QUANTITY: (2) TWO lettersets required for WEST AND EAST elevation CLIENT: D DELTA HOT MARRIOTT ADDRESS: 251 E SH 114 Southlake, TX 76092 iMatthews MAP-LSV929 Carbon Black, satin finish a 3/16" #7328 white acrylic 1/2" DIA SPACER FROM WALL SHEATHING BACK OF LETTER TO FACE OF BLOCKING typical 3/8" DIA. THRU BOLT W/— NUT, FLAT & LOCK WASHERS typical 2X4 WOOD BLOCKING BETWEEN STUDS; ATTACH BLOCKING AT EACH END TO STUDS 7 ��IIIII!IIIII' �dI/ TYPICAL FRAMED WALL MOUNTING DETAIL WALL STUD ON 16" CENTERS SITE SUILVEI 11E111I11ED Daytime Appearance Nighttime Appearance Side Profile LEDCHANNEL-REMOTE.FLUSH-GENERIC INSTALL Lag Bolt & Shields Aluminum returns Trim cap Power supply housing Acrylic face Electronic power supply /� Aluminum backs 0 Listed disconnect/ LED illumination Switch 12 volt jacketed cable Greenfield conduit '/2" minimum Primary electrical Weep holes ''/4" dia. source exterior locations only *MOUNTING METHOD: x°. xrra (Use appropriate method following wall inspection) 4�x°�xxp+xax ° Thin bolt- all thread fasteners w/wood blacking or angle irn stringer Toggle bolts w/hollow re -plywood backing o �x ELEQWC SIGN s .. Kwik Bolts or Expansion lag bolts&shields w/sohdcomete TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: E L S 584990 04/02/20 04/02/20 KW 05/18/20 PS Updated size, mounting, and added plywood backing Added width of logo PROJECT MANAGER: DESIGNER: PAGE NO. JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ELECTRONIC FILE NAME. 4 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MLWEST ELEVATION 13 54INCH STACKED `_ 71 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com ALL SIGN SIZES HAVE BEEN CALCULATED OFF SI773 S jm;'1 ARCHITECTURAL PRINTS AS SHOWN �ltli01311li1) J� 0. STRUCTU� T.O. PARAPET 173' 4" T.D.S ETE L 171' - 4" 6TH FLOOR 18D'-8" � 5TH FLOOR 150' - 0" 4TH FLOOR 139' - 4" 3RQ FLOOR h 128' - 8" >� 2NN FLO� 118'-0" 1ST FLOOR 1D0'-D-D" { CLIENT: D TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: DELTA HOTELS 584990 04/02/20 MARRIOTT PROJECT MANAGER: DESIGNER: ADDRESS: PAGE NO. JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: 251 E SH 114 ELECTRONIC FILE NAME: Southlake, TX 76092 5 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels —South lake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MLEAST ELEVATION 1 54INCH 3 STACKED u 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com ALL SIGN SIZES HAVE BEEN CALCULATED OFF SI773 S jm;'1 ARCHITECTURAL PRINTS AS SHOWN �ltli01311li1) J� ICTUR FLOG 16V - 8" 1501 - 0" Ir F9-4 139-4" FLO 128' - $" FLOOR 118'-0" FLOOR 1a0'-0" CLIENT: D TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: DELTA HOTELS 584990 04/02/20 MARRIOTT PROJECT MANAGER: DESIGNER: ADDRESS: PAGE NO. JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: 251 E SH 114 6 ELECTRONIC FILE NAME: Southlake, TX 76092 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels —South lake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MFACE LIT CHANNEL LETTERS Scale: 1 01354INCH STACKED u 16'-9-3/4" 13'-5-7/8" 1 T-9-3/4" X ILL " r- --------------------------4'-1PLYWOOD BACKING, 130.3 sq ft I I I ' I I I I I I I I I I I I I I I I I I I I I I I I I I -- A111 l 2'-8-7/8" — � I I I I I 1' 6"H071ELS � i I I I I I I 1-5/8" I I I L_____--------------------- 9'-5-1/8" MC g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com FACES: 3/16" #7328 white acrylic RETAINERS: 3/4" alum. retainers - painted black ('D' logo only) TRIMCAP: 1 " Black jewelite (DELTA HOTELS, UNDERSCORE, MARRIOTT) RETURNS: 5" deep .080 alum. - insides pre -painted White; Outsides painted Black BACKS: .063 Alum. - pre -painted White ILLUIll GE White LED as required by manufacturer; Remote Power supplies EAST ELEVATION LETTERSET ONLY Letters to be pre -wired during a special trip. "D" logo, secondary wire to be brought out through the bottom of the logo so it can be accessed from the guest room rather than the roof WALL Not provided at this time MATERIAL: INSTALL: Letters to be mounted flush to fascia using lag bolts and shields as required QUANTITY: (2) TWO lettersets required for WEST AND EAST elevation CLIENT: D DELTA HOT MARRIOTT ADDRESS: 251 E SH 114 Southlake, TX 76092 iMatthews MAP-LSV929 Carbon Black, satin finish a 3/16" #7328 white acrylic 1/2" DIA SPACER FROM WALL SHEATHING BACK OF LETTER TO FACE OF BLOCKING typical 3/8" DIA. THRU BOLT W/— NUT, FLAT & LOCK WASHERS typical 2X4 WOOD BLOCKING BETWEEN STUDS; ATTACH BLOCKING AT EACH END TO STUDS 7 ��IIIII!IIIII' �dI/ TYPICAL FRAMED WALL MOUNTING DETAIL WALL STUD ON 16" CENTERS SITE SUILVEI 11E111I11ED Daytime Appearance Nighttime Appearance Side Profile LEDCHANNEL-REMOTE.FLUSH-GENERIC INSTALL Lag Bolt & Shields Aluminum returns Trim cap Power supply housing Acrylic face Electronic power supply /� Aluminum backs 0 Listed disconnect/ LED illumination Switch 12 volt jacketed cable Greenfield conduit '/2" minimum Primary electrical Weep holes ''/4" dia. source exterior locations only *MOUNTING METHOD: x°. xrra (Use appropriate method following wall inspection) Th. blto- all dread fasteners w/wood blocking or angle iron stringer Toggle bolts w/hollow re -plywood backing e�.ernie sicx s .. Kwik Bolts or Expansion lag bolls &shields w/solid concrete TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: E L S 584990 04/02/20 05/18/20 PS Added width of logo PROJECT MANAGER: DESIGNER: PAGE NO. JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ELECTRONIC FILE NAME. 7 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. ML NORTH ELEVATION 0 IS INCH STACKED 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com SITE SUILVEI 11E111I11ED STRUCTURE 182' - Q" T.O. PARAPET - 4" T.O. STEEL 171' -4" 6TH FLOOR 160' - 8" 5TH FLOOR 150` - QQ" � 4TH FLOOR 139` - 4" 3RD FLOOR h 128' - 8" 2Na FLOOR 118'-Q" 15T FLOOR 1QQ'-0" CLIENT: D DELTA HOTELS TICKET NO.: DATE: REVISION HISTORY: 04/02/20 KW 584990 03/31/20 CLIENT SIGNATURE: Added plywood backing MARRIOTT PROJECT MANAGER: DESIGNER: JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ADDRESS: PAGE NO. 8 251 E SH 114 Southlake, TX 76092 ELECTRONIC FILE NAME. MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels_Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. FACE LIT CHANNEL LETTERS In Scale: 1/2"=11-0"16 39.2 square feet ;. Vlil ELECTRICAL ACCESS TO BE CONFIRMED TO SITE S111r ENSURE REMOTE POWER SUPPLIES ARE POSSIBLE! �11T111I11ED 0 IS INCH STACKED 6-3-1/2" X 8'-5" PLYWOOD BACKING 7'-551 ------- ---- I I I I I I I 1'-6" liI,D I I I I I I I H TEL T-3-1/2" 9-7/$" I I I I I I I I� I I I I I 6-7/ MARRIOTT I L------- — ------I I I —— T-2-1/4" MC g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com FACES: 3/16" #2447 white acrylic with surface applied dual color black vinyl overlays; To illuminate white at night TRIMCAP: 1 " Black jewelite RETURNS: 5" deep .050 alum. - insides pre -painted White; Outsides painted Black BACKS: .063 Alum. - pre -painted White ILLUM.: GE White LED as required by manufacturer, - Remote Power supplies - TO BE CONFIRMED WALL Not provided at this time MATERIAL: INSTALL: Letters to be mounted flush to fascia using lag bolts and shields as required QUANTITY: (1) ONE letterset required for NORTH elevation i3M 3635-222 Black dual -color film a3/16" 2447 white acrylic (channel letters) 1/2" DIA SPACER FROM WALL SHEATHING BACK OF LETTER TO FACE OF BLOCKIN typical 3/8" DIA. THRU BOLT W/ NUT, FLAT & LOCK WASH typical 2X4 WOOD BLOCKING BETWEEN /STUDS; ATTACH BLOCKING AT r EACH END TO STUDS 1 �1�111111� C� , *t"" Ill TYPICAL FRAMED WALL MOUNTING DETAIL WALL STUD ON W CENTERS Daytime Appearance Nighttime Appearance Side Profile LEDCHANNEL-REMOTE.FLUSH-GENERIC INSTALL Lag Bolt & 1 Shields Aluminum returns Trim cap Power supply housing Acrylic face Electronic power < supply CMP�p` Aluminum backs 0 Lisle disconnect LED illumination Switch 12 volt jacketed cable Greenfield conduit 1/2" minimum - Primary electrical Weep holes'/4" dia. source exterior locations only *MOUNTING METHOD: ° (Use appropriate method following wall inspection) Thro bolt- all dread fasteners w/wood blacking w angle irn stringer Togeeboltsw/holl e-plywood baddngo LEW71C SIGN s . Kwik Bolts a Expansion lag bolts & shields w/solid concrete CLIENT: D REVISION HISTORY: TICKET NO.: DATE: CLIENT SIGNATURE: DELTA HOTELS 04/02/20 KW 584990 03/31/20 Updated size, mounting, and added plywood backing MARRIOTT PROJECT MANAGER: DESIGNER: JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ADDRESS: PAGE NO. 9 251 E SH 114 Southlake, TX 76092 ELECTRONIC FILE NAME: MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels_Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. MPROPOSED MONUMENT L TYPICAL OF (2) LOCATIONS 11 INCH LINEAR 4 mc g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com SITE SUILVEI 11E111I11ED MASONRY BRICK MOCK UP CLIENT: D TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: DELTA HOTELS 584990 04/21/20 MARRIOTT PROJECT MANAGER: DESIGNER: ADDRESS: PAGE NO. JAMES PEAKE / TIM FENSKE KW - APPROVAL DATE: 251 E SH 114 10 ELECTRONIC FILE NAME. Southlake, TX 76092 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels -South lake 7F PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. 4 1 HALO LIT LETTERSET In Scale: 3/4"=1'-0" 16 15.78 square feet [a 11 INCH LINEAR 17'-2-5/8" 1 V-2-3/8" 11-3 8" 11" 17- F 10-1 2 51 FACES: .090 alum. painted White RETURNS: 3" deep .063 alum. welded to faces - all welds to be sanded smooth ; painted Black BACKS: 1/4" Clear polycarbonate ILLUMINATION: GE White LED as required by manufacturer; Remote Power supplies Letters to be pre -wired during a special trip INSTALL: 1-1/2" stand off from rock wall surface; Spacers to be provided painted to match bkgd.; Wall has a radius curve of 20'-10" ADDRESS: 1/2" flat acrylic cut outs, painted black; Letters drilled and tapped to accept studs for flush mounting; All penetrations filled with silicone MASONRY BRICK MOCK UP 5'-3-5/8" NARR�(077 6-7/8" jD D Daytime Appearance Nighttime Appearance Side Profile SITE SUILVEl ILE011I11E1) QUANTITY: (2) Two lettersets required; (1) One of each side of entrance ___ iMatthews MAP-LSV929 Carbon Black, satin finish � White MC g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com CLIENT: D DELTA HOT MARRIOTT ADDRESS: 251 E SH 114 Southlake, TX 76092 TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: 04/02/20 KW Added note about pre wiring E L S 584990 03/31/20 PROJECT MANAGER: DESIGNER: PAGE NO. JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ELECTRONIC FILE NAME. 111 MARRIOTT\DELTA H0TEL\2020\TX\De1ta Hotels Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP. ACCENT LIGHTING 'Soa a - ---- t MEN Wfi ! 1�1 SITE PLAN 416 FOR REFERENCE _ 11 INCH LINEAR $� �� sTA 5 w� • o.ai� T HI ao any r WHI-E CH4P EL- I— VILLAGE CEKTER PAR71iERS,T.� _O PROJECT NORTH OOC. NO. O2C5223159, r C.R. T.C. T. Z A i4 N a IL .1 se 1 REMAINDER OF TRACT I —_ CHIVERS ADDITION I VOLUME 3BB-142, PC, 47 l a ■ ACCENT LIGHTING .I;, PR.T.C.T. :,. DONE BY OTHERS 1 - _ __ 18 INCH II r-r I i I STACKED 72INCH b ' II s•I , STACKEDg 1 1 �1 . 'F7 172INCH STACKED iL-j • I � I `r' I M M � a 11 •� � o �• If I u� L I r l 1 •I �E.� r � I I I I I 11 INCH LINEAR r J ----- - =-_ - _ r 1I t ianc«a I ! ea' I Ill r -l. � � -- - -- -- - J•'• i o II r 0111 """""""""'—""""""""----- —" 1 Q t m g r o u p Building Better Brands 8959 Tyler Boulevard Mentor, Ohio 44060 440.209.6200 800.627.4460 theMCgroup.com CLIENT: D TICKET NO.: DATE: REVISION HISTORY: CLIENT SIGNATURE: DELTA HOTELS 584990 03/31/20 04/02/20 KW Updated sign location D MARRIOTT PROJECT MANAGER: DESIGNER: JAMES PEAKE / TIM FENSKE KW APPROVAL DATE: ADDRESS: PAGE NO. 13 251 E SH 114 ELECTRONIC FILE NAME: Southlake, TX 76092 MARRIOTT\DELTA HOTEL\2020\TX\Delta Hotels_Southlake PRINTS ARE THE EXCLUSIVE PROPERTY OF MC GROUP. THIS MATERIAL SHALL NOT BE USED, DUPLICATED, OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF MC GROUP.