Item 7A - PlanU U
U �
� z
a Q
LL J
w D-
Of X F
U)
V O
X 04 C)
W U
M w
Ir Z
x o
N
W
� OL
c �
LL
W N Q
xc\IU)
Z
00
aW
�= a
wO�rn
Q N
J
" J N
O x (D N N
LL O
W W_ N N
O w � N
N X Q -
gLL0)
\ MICKY D. ETUX
ROSE M.
Q GARY & DIANA CHAMBERLAIN 4� INST. NO. D209054829 K NDRICK
/ EX. BARBED D.R.T.C.T. EX. CREEN WALL
/ WIRE FENCE
N85°16��89*52'55"E
32' E�
48 81, _ OLD LOT LINE -
-_ Z------------- -- r
a) C) X HHP 51.1 ❑HP ❑HP -
24' 30'
rl 10' U S89`43'47"W 332.55' I 2
OLD LOT LINEEX. CHAIN q0
LINK FENCE t 15.6'
it
I
N
z I
o
N
01
O p I
00 1
ml
LOUIS EST & AMERICA KAPOSTA
rpm
VOL. 6478, PAGE 898
0 I
D.R.T.C.T.
r
ZONED AG
m I
LUD - INDUSTRIAL
v
W
Ln I
bo
`I I
I
Zc� r59'
o
S2O�
50R °
52 50
37'
ri 52 52
c4RM cn
o INLET
J
I l m 101x25' OFF STR T I
LOADING SPACE
I EXISTING POND
N EX. 8' CHAIN LINK FENCE -
FIRE HYDRANT-
- - - - - - - I - - - - - %
788°46'20"7261.34' 1
THOMAS FAMILY PARTNERSHIP LLLP
INST. NO. D207134227
D.R.T.C.T.
ZONED SP2
LUD - INDUSTRIAL
10' U.E.-t-i
0II
III
N
W
ml
FIRE
HYDRANT I
L41I
00
CA
III
STORM INLETT
EX. TRASH DUMPSTER WITH
6' HIGH MASONRY SCREENING
WALL -
11.2
10' U.E:
CONCRETE PARKING
8' CHAIN LINK SECURITY I
FENCE RELOCATED
CHANDRACO BROADGATE GROUP
INST. NO. D207280472
D.R.T.C.T.
ZONED SF 1A
LUD - LOW DENSITY RESIDENTIAL \
H
ESADS
SC
R
A
D
F
0
TB
NIL
SPE
K
R
P
L
FI
L
8'
MASONRY
S
R
E
I
G
WALL
ZONED 01
LUD - OFFICE COMMERCIAL I I II \
CHARLESTON COURT LP 5' CONCRETE
INST. NO. D205158792 SIDEWALK
D.R.T.C.T.
S89°26'47"E 252.80' S89°26'47"
FROM PLL 104.37- _
�T Z1P 6 - - ----
R W ------
I I II
II I
T - II III
I � I
II III
I I
S+M INLETI I
II
C
�� I I
1
af
LL_
�II III
BFR
1
10D.E.1
J
I- a III
I� � I I
N I I I
ONED SP1
ILIJ
S MI -PUBLIC
CARROLL ISD
NO. LOCKDIITIONI
I LOT 1
5' CONCRETE
SIDEWALK
1STRM INLET I
II I
I� III
NI I I
N I I
FIR
A & B PROPERTIES INC.
ETAL
INST. NO. D207391683
D.R.T.C.T.
A & B PROPERTIES INC.
ETAL
INST. N0. D207391683
D.R.T.C.T.
I
I
I
I
I
I
L----
\ k$\ Y IUN MAJUINKT U1- ul
_
SCREENING WALL 3
0 1 1
TIRE STORAGE BUILDING FIR LANE &2 5 s j SS A--6°30'26"
\ 1,200 SF i Tlk T
RM INLET 3 i I R=68199'
1 STORY T 1 E I CL=77.41'
HEIGHT=17'-7"
15' U. E. FRpM A=10°49'10"I
s \ EX. 8' HIGH VINYL COATED GRASS FIRE k Si R=681.99' I I
SCREENING FENCE i INLET HYDRANT i BUILDING
/ \ � �g"0jD STORM INLET CL=128.59'
\ STORM INLET I YDRFIRE ANT 10 I
I �
10' TYPE A LANDSCAPE
& \ 94' iz+oo BUFFER
/
STORAGE BUILDING
LOCATION 24'X50'
ZONED 11 \ SS _ SS A & B PROPERTIES INC ETAL
LUD - INDUSTRIAL SS ss INST. NO. D207391683
CAPITAL ONE S L J CONTINENTAL PLAZA LTD 6' CONCRETE A=23°34'57" D.R.T.C.T.
INST. NO. / D209179594 GREEN MEADOW SUBDIVISION SIDE -WALK R=753.00 ZONED 11 D.R. T.C.T. LOT 3R5R CL=307.75 LUD INDUSTRIAL
SITE DATA SUMMARY
EXISTING
PROPOSED
ZONING
SP-1
SP-1
LAND USED DESIGNATION
PUBLIC/
SEMI-PUBLIC
PUBLIC/
SEMI-PUBLIC
GROSS ACREAGE
35.801
34.787
NET ACREAGE
35.801
34.787
NUMBER OF PROPOSED LOTS
1
1
AREA OF OPEN SPACE
11 ACRES
9.987 ACRES
AREA OF IMPERVIOUS COVERAGE
24.80 ACRES
24.80 ACRES
PERCENTAGE OF OPEN SPACE
30.73%
28.71%
PERCENTAGE OF IMPERVIOUS COVERAGE
69.27%
71.29%
BUILDING AREA (BUILDING FOOTPRINT)
STADIUM HOME
44,995
44,995
STADIUM VISITOR
21,540
21,540
FIELD HOUSE
11,590
11,590
MAINTENANCE BUILDING
11,535
11,535
NUMBER OF STORIES
3
3
MAXIMUM BUILDING HEIGHT
80'-0"
80'-0"
PROPOSED FLOOR AREA
STADIUM SEATING
10,700
10,700
HOME
7,683
7,683
VISITOR
3,017
3,017
FLOOR AREA BY USE STADIUM BUILDING:
CONCESSION
3,500
3,500
STORAGE
400
400
OFFICE
1,500
1,500
RESTROOMS
5,090
5,090
PRESS BOX
3,379
3,379
D. R. C
1,700
1,700
FLOOR AREA BY USE MAINTENANCE BUILDING:
SHOP
5,825
5,825
OFFICE
1,750
1,750
STORAGE
2,057
2,057
REQUIRED PARKING/GAME
2,096
2,096
PROVIDED PARKING/GAME
STANDARD
2,052
2,052
HANDICAP
44
44
TOTAL
2,096
2,096
BUSES
44
44
PROVIDED PARKING/NON-GAME
STANDARD
1,911
1,911
HANDICAP
44
44
TOTAL
1,955
1,955
BUSES
94
94
LOADING SPACES: REQUIRED/PROVIDED
TWO/TWO
TWO/TWO
AREA OF OUTSIDE STORAGE
108,150
108,150
PERCENTAGE OF OUTSIDE STORAGE
7.00%
7.13%
START CONSTRUCTION MONTH/YEAR
END CONSTRUCTION MONTH/YEAR
Q
W
�
0.8
N
O
Q
o N
INWOODFo
14
m a o
F
Q
O KNO(�
B114
Ke
6� VO
1709
1
WALL
3 a
WZw
o
a
am
o W m a
SITE
6
26
w
Z
5�
o
W
m
BUFFERYARD SUMMARY BLOCK 1 - LOT 1
LOCATION
LENGTH (ft.)
BUFFERYARD
CANOPY TREES
ACCENT
SHRUBS
FENCING/SCREENING
WIDTH -TYPE
TREES
HEIGHT & MATERIAL
NORTH
REQUIRED
995.94'
10'-C
40
53
160
8' HIGH SCREENING
DEVICE
PROVIDED
995.94'
10'-C
40
53
160
8' HIGH SCREENING
DEVICE
EAST SILICON
REQUIRED
NONE
NONE
NONE
NONE
NONE
NONE
DR.
PROVIDED
NONE
NONE
NONE
NONE
NONE
NONE
SOUTH
REQUIRED
800' a
10'-E
8
16
64
NONE
KIMBALL AVE.
PROVIDED
800' a
10'-E
8
16
64
NONE
WEST
REQUIRED
NONE
NONE
NONE
NONE
NONE
NONE
PROVIDED
NONE
NONE
NONE
NONE
NONE
NONE
INTERIOR LANDSCAPE SUMMARY
REQUIRED/
LANDSCAPE
% AREA
CANOPY
ACCENT
GROUND
PROVIDED
AREA (sq.ft.)
FRONT SIDE
TREES
TREES
SHRUBS
COVER (sq.ft.)
20
REQUIRED
SQ.FT/SPACE
50%
NONE
1 PER ISLAND
NONE
NONE
30,000 SQ.FT.
20
PROVIDED
SQ.FT/SPACE
50%
NONE
1 PER ISLAND
NONE
NONE
32,000 SQ.FT.
*NOTE ANY CREDITS USE IN CALCULATIONS:
A. REQUIRED PLANT MATERIAL HAS BEEN REDUCED BY 20% FOR AN INCREASE IN BUFFERYARD WIDTH.
B. BUFFERYARD LENGTH HAS BEEN REDUCED TO ACCOMMODATE THE SHOWN DRIVES.
NOTES:
1. SPECIFIC PLANT TYPES AND LOCATIONS ARE SUBJECT TO REVIEW BY THE LANDSCAPE ADMINISTRATOR DURING THE BUILDING
PERMIT APPLICATION PROCESS. CREDITS FOR A REDUCTION IN REQUIRED PLANT MATERIALS, AS SPECIFIED BY CITY ORDINANCE,
WILL BE DETERMINED DURING T HIS BUILDING PERMIT PROCESS.
2. A MINIMUM OF 50% OF ALL CANOPY TREES PLANTED ON THE SITE MUST BE 2" IN CALIPER AND 50% MUST BE 4" INCALIPER.
THIS INCLUDES PLANTINGS IN BUFERYARDS AS WELL AS INTERIOR TO THE SITE.
3. ACCENT/UNDERSTORY TREES ARE REQUIRED TO BE A MINIMUM OF 6' IN HEIGHT WHEN PLANTED.
4. ALL PLANT MATERIALS ARE TO BE MAINTAINED IN PERPETUITY.
VICINITY MAP
N.T.S.
N
W � � E
�lr
0 100' 200'
GRAPHIC SCALE 100'
LEGEND
PROPERTY LINE
EXISTING FIRE LANE
EXISTING LIGHT POLE
# PROPOSED LIGHT POLE
s?
� J
Q
W
co
o
Q
�
U O X
11
Oa)_
°'5�q
E
c /^1
L N
U
�/ /
Q
0
N ? �` Ncn
L
4)
+
0)
c
o
(n
W X
W
c>
-r q
w.�
4-
c: U)
NLLI
_0
Z
Z 0 N
:5; U)
ti
� r1
�.J
V co
L N 0)
t�
z
N
~
Q
2
REVISED SITE PLAN
CARROLL ISD No. 6 ADDITION
LOT 1, BLOCKS 1 AND 2
40.333 ACRES (1,756,905)
A.A. McDONALD SURVEY ABSTRACT No. 1013 TARRANT COUNTY, TEXAS
CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS
CITY OF SOUTHLAKE CASE No. ZA21-0069
OWNER ENGINEER
CARROLL ISD BOARD OF TRUSTEES HART GAUGLER + ASSOCIATES, INC.
2400 N. CARROLL AVENUE 12801 N. CENTRAL EXPWY. SUITE 1400
SOUTHLAKE, TEXAS 76092 DALLAS, TEXAS 75243
817-949-8228 972-239-5111 / 972-239-5055 (FAX)
MATT MILLER TEXAS REGISTERED ENGINEERING FIRM #F-5053
MATT.MILLER@SOUTHLAKECARROLL.EDU JOHN D. BLACKER JBLACKER@HARTGAUGLER.COM
SURVEYOR
PEISER & MANKIN SURVEYING, LLC
1604 HART STREET
SOUTHLAKE, TEXAS 76092
PHONE (817) 481-1806
FAX (817) 481-1809
CONTACT: TIMOTHY MANKIN
EMAIL: TMANKIN@PEISERSURVEYING.COM
OCTOBER 10, 2021
JOHN D. BLACKER
...................... ........
I .0 �. 68300
t el
%/ SAL LNG D�
z
O
_MQ
O
o�
W
�
z
}
G
Q
Z)
0
Q
cq
D
0�U
p
Q
Qcoz
0
m
::)
LLi
0
co
_j
V
<JJz�
O
_
O
Q
O
LL
2
LL
Q
O
Q
Q
�
U
c)
Z
L.L
w
I-
V J
0
rw
v
w
N
j
N
O
ai
00
U)
Q
Q
2
a
=
m
(D
Q
N
°
>
-O
Z
4)
�
2�
U
N
cn
SHEET
C0.01