Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
SB Item 6 - Demonstration and Plans
SIGN VARIANCE APPLICATION Demonstration Please demonstrate that the following conditions are applicable to the requested sign variance: 1. That a literal enforcement of the sign regulation will create an unnecessary hardship or practical difficulty on the applicant. 2. That the situation causing the unnecessary hardship or practical difficulty is unique to the affected property and is not self imposed. 3. That the variance will not injure and will be wholly compatible with the use and permitted development of adjacent properties. 4. That the variance will be in harmony with the spirit and purpose of the sign ordinance. Page 1 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Perspire Sauna Studio 2251 E. Southlake Blvd. Suite 100 Southlake, TX 76092 Drawing Prepared For : Version 10.0C December 20, 2024 Page 2 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C E. Southlake Blvd. SUITE 100 24’-0” STOREFRONT WIDTH S. Kimball Ave.Site Plan Not To Scale 401’-0” SETBACK FROM E. SOUTHLAKE RD. SIGN LOCATIONC Page 3 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Tenant Floor Plan Scale: 3/16” = 1’-0” SIGN LOCATIONC PLACEMENT OPTION A SIGN LOCATIONC PLACEMENT OPTION C SIGN LOCATIONC PLACEMENT OPTION B SIGN LOCATIONC PLACEMENT OPTION D Page 4 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Sign Type C (Rear Elevation Channel Letter Sign): Manufacture & install one (1) set of face-illuminated channel letters. 5” deep 0.040” thick aluminum channel letter return 1” Jewelite trim cap .118” 7328 translucent white acrylic face 6500K white LED module drain hole with light baffle SealTite through-wall conduit; all wall penetrations sealed with non-hardening weatherproof sealant low-voltage LED cable Class II LED power supply MC12/2 flexible conduit primary junction box with service disconnect (existing) incoming dedicated 120V/20A sign circuit (existing) 10-24x3/8” pan head trimcap retaining screws, painted to match trim cap color 3/8”x4” S.S. lag screws with 1/2” S.S. spacers, min. 3 per letter 0.063” thick aluminum back Code Allowance: Total Sign Area: Sign Width: 24 sq. ft. (1 sq. ft. per lin. foot of frontage) 23.8 sq. ft. (99% of allowance) 9’-4½” (39% of 24’-0” frontage) 01 Channel Letters: •Faces: M1 1/8” thick translucent white 7328 acrylic •Trimcap: 1” Jewelite, painted P1 MP White Wonder •Returns: 5” deep 0.040” thick aluminum, painted P1 White Wonder •Backs: 0.063” thick aluminum, pre-finished white •Illumination: 6500K white LEDs •Power Supplies: 12V, remotely mounted behind wall •Installation: mounted to wall with 1/2” stainless steel spacers (verify wall construction and hardware)3”1½”5” M1 P101 A A Material Finishes: Matthews Paint MP32071 White Wonder, Satin Finish M1 P1 Paint Colors: Acrylic 7328 Translucent White End View Scale: ¾” = 1’-0” End View Scale: ¾” = 1’-0” Face View Scale: ¾” = 1’-0” 5” deep 0.040” thick aluminum channel letter return 1” Jewelite trim cap translucent white acrylic face Section Detail A-A (Typical) - Not To Scale 9'-4½" (112½")2'-6½" (30½")5” Page 5 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Sign Type C - Elevation View - Placement Option A Scale: ½” = 1’-0” 27’-4” WALL WIDTH 11’-1” SIGN WIDTH (46% OF SIGN BAND WIDTH)EQ 2’-6½” SIGN HT EQ 6'-10¼" A.F.G. TO BASELINE OF SIGN12” EQ 9’-4½” SIGN WIDTH12”7'-3¾" A.F.G. TO BASELINE OF SIGN24’-0” STOREFRONT WIDTH 24’-0” TENANT SPACE WIDTH 3’-10” 7’-0” END OF BUILDING TO TENANT SPACE Page 6 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Daytime Elevation Rendering - Placement Option A Not To Scale Simulated Nighttime Rendering - Placement Option A Not To Scale Page 7 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Sign Type C - Elevation View - Placement Option B Scale: ½” = 1’-0” 27’-4” WALL WIDTH 11’-1” SIGN WIDTH (46% OF SIGN BAND WIDTH)EQ 2’-6½” SIGN HT EQ 7'-0” A.F.G. TO BASELINE OF SIGN12” EQ 9’-4½” SIGN WIDTH12”7'-5” A.F.G. TO BASELINE OF SIGN24’-0” STOREFRONT WIDTH 24’-0” TENANT SPACE WIDTH7’-0” END OF BUILDING TO TENANT SPACE 8’-0” END OF BUILDING TO SIGN Page 8 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Daytime Elevation Rendering - Placement Option B Not To Scale Simulated Nighttime Rendering - Placement Option B Not To Scale Page 9 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Sign Type C - Elevation View - Placement Option C Scale: ½” = 1’-0” 27’-4” WALL WIDTH 11’-1” SIGN WIDTH (46% OF SIGN BAND WIDTH)EQ 2’-6½” SIGN HT EQ 7'-3” A.F.G. TO BASELINE OF SIGN12” EQ 9’-4½” SIGN WIDTH 12”7'-8” A.F.G. TO BASELINE OF SIGN24’-0” STOREFRONT WIDTH 24’-0” TENANT SPACE WIDTH7’-0” END OF BUILDING TO TENANT SPACE 12'-8 ¾" END OF BUILDING TO SIGN Page 10 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Daytime Elevation Rendering - Placement Option C Not To Scale Simulated Nighttime Rendering - Placement Option C Not To Scale Page 11 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Sign Type C - Elevation View - Placement Option D Scale: ½” = 1’-0” 27’-4” WALL WIDTH 11’-1” SIGN WIDTH (46% OF SIGN BAND WIDTH)EQ 2’-6½” SIGN HT EQ 7'-1” A.F.G. TO BASELINE OF SIGN12” EQ 9’-4½” SIGN WIDTH 7'-6” A.F.G. TO BASELINE OF SIGN24’-0” STOREFRONT WIDTH 24’-0” TENANT SPACE WIDTH7’-0” END OF BUILDING TO TENANT SPACE 8'-11" END OF BUILDING TO SIGN (EQ)8'-11" END OF BUILDING TO SIGN (EQ) Page 12 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C Daytime Elevation Rendering - Placement Option D Not To Scale Simulated Nighttime Rendering - Placement Option D Not To Scale Page 13 of 13 All artwork designed by United Image Group is the sole property of United Image Group and may not be reproduced without written permission. Any and all artwork proofs are also the property of United Image Group and may not be used for any other purpose. Customer Approval Signature:Date: 4676 Freedom Drive, Ann Arbor, MI 48108 734-662-5964 | unitedimagegroup.com © Copyright 2024 United Image Group, All Rights Reserved Perspire Sauna Studio - Southlake, TX | Exterior Signage Date: Sales Rep: Designer: Version: 12/20/2024 BL LB 10.0C