Loading...
Item 10 - Staff ReportCase No. ZA24-0061 STAFF REPORT November 1, 2024 CASE NO: ZA24-0061 PROJECT: Zoning Change and Development Plan for WillowTree Gardens EXECUTIVE SUMMARY: Redinger Group, LLC, on behalf of WTG Overlook, LLC, are requesting approval of a Preliminary Plat for WillowTree Gardens, on property described as Tract 3C, and portions of Tracts 3D03, and 3D03A, W.W. Hall Survey Abstract 695, City of Southlake, Tarrant County, Texas and located at 240 N. Carroll Avenue and portions of 918-1050 E. Southlake Blvd., Southlake, Texas. Current Zoning:: “TZD” Transitional Zoning District. SPIN Neighborhood #7. DETAILS: This project is located primarily along the west side of N. Carroll Ave, approximately 750 feet north of the E. Southlake Blvd. intersection. The purpose of this request is to approve a Preliminary Plat in conformance with the Zoning Change and a Development Plan. ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Preliminary Plat Approval Department of Planning & Development Services Case No. ZA24-0061 ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plat Review Summary No 1. dated November 1, 2024. (D) Surrounding Property Owners Map & Responses PowerPoint Presentation Plat & Supporting Plans STAFF CONTACT: Dennis Killough (817) 748-8072 Case No. Attachment A ZA24-0061 Page 1 BACKGROUND INFORMATION OWNER: WTG Overlook, LLC APPLICANT: Redinger Group, LLC PROPERTY SITUATION: 240 N. Carroll Avenue and portions of 918 -1050 E. Southlake Blvd., Southlake, Texas. PROPERTY DESCRIPTION: Tract 3C, and portions of Tracts 3D03, and 3D03A, W.W. Hall Survey Abstract 695, City of Southlake, Tarrant County, Texas LAND USE CATEGORY: Medium Density Residential CURRENT ZONING: TZD” Transitional Zoning District HISTORY: “AG” zoning was placed on the entirety of the property upon the adoption of the first zoning ordinance. A portion of the property zoned was zoned “A -3”, under Zoning Ord. No 161, on June 5, 1979. It was rezoned to “SF -1” on August 19, 1986. “SF - 1A” zoning was placed on the property with the adoption of Zoning Ordinance No. 480 in 1989. On May 21, 2024, the City Council approved a Zoning Change and Development Plan (Case ZA23-0072, Ord. 480-810) to “TZD” subject to “Development Plan D” with the following changes: Noting that the applicant has agreed there will be no more than a total of twenty (20) residences in the residential portion, that is the total property both inside and outside of the gated area including the Cross Lane properties. Noting the applicant has agreed that there will be resident only gate access on both the east and west entry points to the residential area. The applicant will work with staff to identify appropriate technology specifically not keypad technology to minimize the ability to circumvent access restrictions to residents only. The five (5) lots represented west off of Cross Lane shall be at least the size represented on “Development Plan D”. There shall be a full masonry wall from north to south covering the western edge of divider between the five (5) Cross Lane lots and the gated area and Cross Lane. Noting that a Site Plan shall be submitted for staff and City Council design review to ensure compliance with location, access points, and consistency with what was approved in this motion. Case No. Attachment A ZA24-0061 Page 2 On September 17, 2024, the City Council approved a Site Plan for The Overlook and WillowTree Gardens , “Development Plan D – Alternative 2” SOUTHLAKE COMPREHENSIVE PLAN: Consolidated Future Land Use Plan The future land use designation for the site is “Office Commercial” (approved by case CP24 -0001) on the eastern quarter of the site and “Medium Density Residential” on the western three-quarters. The Office Commercial category is a commercial category designed and intended for the exclusive use of office and limited office‐related activities. It is established for and will be allocated to tho se districts best suited for supporting commercial activity of an office character. It has been established to encourage and permit general professional and business offices of high quality and appearance, in attractive landscaped surroundings with the types of uses and design exterior appearance so controlled as to be generally compatible with existing and future adjacent and surrounding residential development. Properties with this designation may serve as a transition between established residential neighborhoods, major roadways, and retail development. The purpose of the Medium Density Residential land use category is to promote a neighborhood setting primarily comprised of single family detached houses. The Medium Density Residential category is suitable for any single‐family detached residential development. Other suitable activities are those permitted in the Public Parks/Open Space and Public/Semi‐Public categories previously discussed. Mobility & Master Thoroughfare Plan The subject property is bounded by N. Carrol l Ave to the east and E. Southlake Blvd. to the south, though this development is not proposed to connect to this roadway. N. Carroll Ave. is a fully developed four lane divided arterial with 100’ of right of way. Pathways Master Plan & Sidewalk Plan The Pathways Plan shows a less than 8’ sidewalk along the west side of N. Carroll Ave. The applicant is proposing a 5’ sidewalk along their developed portion of Carroll Ave., and has noted a willingness to construct a 5’ sidewalk north to Ownby Lane to connect the development to Southlake Town Square. Case No. Attachment A ZA24-0061 Page 3 Site Specific Recommendations • Retain the Medium Density Residential land use designation. • For properties fronting on Carroll Ave., garden office uses may be considered if development is planned in a comprehensive manner. • Buffer existing and future residential uses from office uses. • Any future connection of Cross Lane to Carroll Ave. is not intended. • Any office development along Carroll Ave. should have cross access back to the traffic signal at F.M. 1709/Tower Plaza as well as to the office properties to the south to access the existing drive cut on Carroll Ave. • A new drive cut at Carroll Ave. and Main Street is not recommended due to existing traffic conditions/volumes at this intersection and the close proximity to the light. TRANSPORTATION ASSESSMENT: Area Road Network and Conditions The proposed “TZD” zoning request has two entrances onto N. Carroll Ave. (Note separation variance request.) An emergency only access gate is also proposed to connect to Cross Lane to the west. The Traffic Impact Analysis r e c o m m e n d s a n o rth bound left turn into the development at the northern driveway of the site along Carroll Ave. Traffic Counts N. Carrol Ave. (65) (Between E. Southlake Blvd. & E. SH 114) 24hr North Bound (11,458) South Bound (11,746) AM Peak (821) 11:45AM – 12:45PM Peak (956) 11:30AM – 12:30PM PM Peak (928) 12:45 – 1:45PM Peak (1,199) 4:45 – 5:45PM * Based on the (2017-2018) City of Southlake Traffic Count Report TREE PRESERVATION: The site is subject to the City’s Tree Preservation Ordinance No. 585 -D. The approved Tree Preservation Plan showed t here is 24.5% of existing tree cover on the property. A 71.52% is proposed to be removed and a 28.48% is proposed to be preserved. UTILITIES: The property is served by an existing 8” water line along N. Carroll Ave. and an existing 8” sanitary sewer line along the west boundary of the Case No. Attachment A ZA24-0061 Page 4 property under consideration. DRAINAGE: An on-site retention/detention facility is proposed. CITIZEN INPUT: The following meetings were held to discuss the development: A SPIN meeting was held for this project on August 22, 2023. The item was heard by the Corridor Planning Committee on January 30, 2024. PLANNING & ZONING COMMISSION ACTION: CITY COUNCIL ACTION: STAFF COMMENTS: Attached is Plat Review Summary No. 1, dated November 1, 2024. Case No. Attachment B ZA24-0061 Page 1 Case No. Attachment C ZA24-0061 Page 1 PLAT REVIEW SUMMARY Case No.: ZA23-0072 Review No.: One Date of Review: 11/01/24 Project Name: Preliminary Plat – Willowtree Gardens APPLICANT: OWNER: Redinger Group, LLC WTG Overlook, LLC P.O. Box 93206 680 N Carroll Avenue, Suite 100 , Southlake, Texas 76092 Southlake, Texas Phone: 817-253-5727 Phone: 817-617-9105 Email: cr@redingergroup.com Email: jody@willowtreetx.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 10/14/24 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT DENNIS KILLOUGH AT (817) 748-8072. The following changes are needed according to the Subdivision Ordinance, as amended, Sections 3.01, 3.02, & 8.01 1. Place the City case number “ZA24-0061" in the lower right-hand corner of the plat. 2. Show and label all survey lines. Show the W.W. Hall & R. Eads Survey line which generally runs along the original center line of Carroll Ave. 3. The Following Changes are needed regarding the streets and access per Section 5 of the Subdivision Ord. No. 483: a. The portion of the street that is to be gated and private must be designated as a Private Access, Emergency Access, Drainage and Utility Easement and must be a separate lot dedicated to and maintained by the owner’s association. It must comply with the standards under Section 5.05. b. The extension and turn-around for Cross Lane must be public ROW meeting City street standards and dedicated to the City. c. The driveways accessing Carroll Ave. up to the residential entry gate and the driveway stub to the Strunck tract shown on the development plan must be in Common Access Easements with a minimum widthg of 24’ and covering the full width of the driveway. 4. The retention/detention pond open space lots need to be in uniquely numbered ‘X’ lots. 5. Any HOA maintained walls or landscape areas that are not in a HOA “X” lot should be in a private HOA easement for wall or landscape. 6. Show and label the existing R.O.W. with dimensions, i.e., public streets, highways, alleys, private street/drives, railroads, etc. Also provide dimensional centerline references to existing or approved street intersections on the perimeter of the subdivision or within 200 feet of the perimeter. Case No. Attachment C ZA24-0061 Page 2 7. Sidewalks should be in a public pedestrian easement Case No. Attachment C ZA24-0061 Page 3 Tree Conservation TREE CONSERVATION COMMENTS: 1. The submitted Tree Conservation Plan generally conforms to the approved Tree Conservation Plan. Some of the protected trees as shown on the approved Tree Conservation Plan are shown to be removed. 2. Provide the existing tree cover preservation calculations on the Tree Conservation Plan. The existing tree cover calculations consist of the total percentage of existing tree cover on the property, the total percentage of existing tree cover proposed to be removed, and the total percentage of existing tree cover proposed to be preserved. * Indicates informational comment. # Indicates required items comment. E-mail: kmartin@ci.southlake.tx.us Keith Martin Landscape Administrator Phone: (817) 748-8229 Case No. Attachment C ZA24-0061 Page 4 Public Works/Engineering Review GRADING AND DRAINAGE: 1. Provide a preliminary grading plan. UTILITY 2. Sanitary sewer shall be located a minimum of 5’ behind curb. The proposed sewer adjacent to the on street parking doesn’t meet this. Sandra Endy , P.E. Development Engineer Phone: (817) 748-8033 E-mail: sendy@ci.southlake.tx.us Case No. Attachment C ZA24-0061 Page 5 Fire Department Review The required backflow protection (double check valve) for the sprinkler systems can be located on the riser if the riser is within 100 feet of the water main, measured linearly along the length of the pipe. If the riser is further than 100 feet from the main, the double check valve shall be in a vault. Riser rooms shall be a minimum of 5’X5’ if the double check is located in a vault, or a minimum of 6’X6’ if it is located on the riser. (No riser room location or size indicated on the site plan) FIRE LANE COMMENTS: Fire apparatus access fire lanes need to be provided within 150 feet of all exterior portions of the perimeter of buildings on a “hose -lay” basis for non-sprinkled buildings and within 250 feet of sprinklered buildings. Fire apparatus access needs to be an all -weather surface, asphalt or concrete, a minimum of 24 feet wide and able to support the imposed loads of fire apparatus. (Minimum of 85,000 pounds GVW) Dead-end fire apparatus access cannot exceed 150 feet. Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, a minimum of 26 feet wide fire apparatus access fire lane is required. (Site plan does not indicate the minimum requirements for a 26 feet wide fire lane due to the max height indicated) Where the fire apparatus access fire lane consists of a divided roadway at the access gates, the gate width must not be less than 12 feet. The access gate must be provided with a manual means of operating the gate and an automatic means. FIRE HYDRANT COMMENTS: Fire hydrants are over spaced between the commercial and residential portions of the development, add an additional fire hydrant near the entrance into the residential area. (No hydrants indicated on the most recent site plan) Case No. Attachment C ZA24-0061 Page 6 General Informational Comments * The remainder of the tracts must be appropriately zoned and platted prior to further development or conveyance. * Developer must comply with US postal delivery methods per Post Master. * All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. * All development must comply with the standards of the “TZD” Transition Zoning District and approved Development Plan or Site Plan. * A Developers Agreement is required prior to construction of any public infrastructure. The Developer's Agreement for this addition should consider streets, drainage, park dedication requirements and fees, off-site sewer extensions, off -site drainage and utility easements and impact fees. * The applicant should be aware that prior to issuance of a building permit a Final Plat must be processed and filed in the County Plat Records, a fully corrected site plan, landscape plan, irrigation plan, and building plans, must be submitted for approval and all required fees must be paid. This may include but not be limited to the following fees: Park Fee, Roadway Impact Fee, Water & Sewer Impact and Tap Fees, and related Permit Fees. * In addition to the City of Southlake impact fees, please be aware that through the wholesale water customer contract with the City of Fort Worth, all new water connections are required to pay the City of Fort Worth impact fee. The City of Fort Worth impact fee assessment is based on the final plat recordation date and building permit issuance. The applicant is encouraged to review the City of Fort Worth's assessment and collection of Impact Fees Guide to determine the fee amount. * Denotes Informational Comment Case No. Attachment D ZA24-0061 Page 1 SURROUNDING PROPERTY OWNERS MAP & RESPONSES Responses: F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Forty-two (42) Responses Received within 300’: Responses Received outside 300’: