Loading...
Item 6C - Staff ReportS0UTHLA1<,..-E PLANNING & DEVELOPMENT SERVICES STAFF REPORT August 13, 2024 CASE NO: ZA24-0011 PROJECT: Site Plan for Restoration Church EXECUTIVE SUMMARY: Darren Andrews P.E. with The John R. McAdams Company Inc., on behalf of Restoration Church, is requesting approval of a Site Plan, on property described as Lot 4, F. Throop No. 1511 Addition, City of Southlake, Tarrant County, Texas, and located at 1280 E Highland St. Current Zoning: "CS" Community Service District. SPIN Neighborhood #3. DETAILS: The applicant is proposing a 2 story 12,516 sq. ft addition to be utilized as classroom and meeting space and the expansion of the existing parking area from 48 spaces to 147 spaces. Site Data Summary Proposed Current Zoning "CS" Proposed Zoning 'CS" Land use Designation Public/Semi-Public Gross Acreage 7.246 acres Number of Lots 1 Total Building Area 27,998 sf Percentage of Building 8 87% Coverage Percentage of Open Space 69.65% Number of Stories 2 Proposed Building Height Maximum of 35 ft Percentage of Impervious 29 32% Coverage Required/Provided Parking 140/148 spaces VARIANCES: 1) Section 39.6 of the Zoning Ord. No. 480, requiring a minimum 8' solid fence meeting 39.2.b. along the boundary lines abutting the residential lot or dwelling. Applicant requests fencing/screening to remain as currently exists. 2) Driveway Ordinance No. 634. requiring a min. stacking depth of 75'. The existing west driveway currently has no stacking depth and the applicant proposes improving the stacking depth to approximately 50'. Case No. ZA24-0011 ACTION NEEDED: 1) Conduct a Public Hearing 2) Consider Approval of a Site Plan ATTACHMENTS: (A) Background Information (B) Vicinity Map (C) Plan Review Summary No. 3, dated August 13, 2024 (D) Surrounding Property Owners Map (E) Surrounding Property Owners Responses Full Size Plans (for Commission and Council members only) STAFF CONTACT: Narrative PowerPoint Presentation Plans Dennis Killough (817) 748-8072 Morgan Barclay (817) 748-8127 Case No. ZA24-0011 BACKGROUND INFORMATION OWNER: Restoration Church APPLICANT: Darren Andrews, P.E., The John R McAdams Company Inc. PROPERTY SITUATION: 1280 E Highland St. LEGAL DESCRIPTION: Lot 4, F. Throop No. 1511 Addition, City of Southlake, Tarrant County, Texas LAND USE CATEGORY: Public/Semi-Public CURRENT ZONING: "CS" Community Service District HISTORY: The property was annexed into the City with Ord. 84 in 1957. The property was zoned "CS" Community Service district with the adoption of the Official Zoning M of the City of Southlake under the Zoning Ordinance No. 480 on September 19, 1989. A Plat Showing for Carroll Road Baptist Church was approved in May of 1993. SOUTHLAKE COMPREHENSIVE PLAN: Consolidated Future Land Use Plan The future land use designation for the site is "Public/Semi-Public". The Public/Semi-Public areas are suitable for a wide range of public, civic, and religious uses, such as government offices and facilities, public and private schools, churches and related facilities (including parsonage and parochial schools), cemeteries, and Public Parks/Open Space uses in conjunction with these developments. Mobilitv & Master Thoroughfare Plan The property is located along E. Highland St. This section of E. Highland St. is designated as a 4-lane divided arterial with a 88' ROW. Pathways Master Plan & Sidewalk Plan The pathways plan shows an existing < 8' sidewalk along this portion of E. Highland St. There is an existing 6' sidewalk through the frontage of this site. UTILITIES: There is an existing 12" water line located along E. Highland St. There is an existing 8" sewer line located along E. Highland. Case No. Attachment B ZA24-0011 Page 1 PLANNING AND ZONING COMMISSION: August 8, 2024, APPROVED (5-0) Subject to Staff Report dated August 8, 2024, and subject to Staff Review Summary No 2 Revised dated August 8, 2024, noting the applicant will review widening the ingress/egress point located on the west side of the building, and consider relocating the dumpster enclosure to the west side of the property, and noting denial of the variance requested for the stacking depth. STAFF COMMENTS: Attached is Site Plan Review Summary No. 3, revised August 13, 2024. Case No. Attachment B ZA24-0011 Page 1 SPO Map ZA24-0011 1280 E Highland St -__-________-__ -- aw � 4 _ f tion 2 i iementary f 5chnal Jahntan F1rm2rtnr 3 k :enter t 1 1 Make I I I I � I I � I � I ( I w 4 J J I 1000 � 6 � I � I I � I 1 � L;u rail 9rpilst �} � �Ch�lrrh l I - y-HIGHaND 5T l �a 11 12 13 ti Sauthla" r saptistchur4 - x ` — — — — — — — — — — - Legend City Parcels Right Of Way r — ti City I_I11'11t Parcels Withirt Buffer _ J 300 Foot Buffer G 130 250 520 Feet 0 200 Font Buffer Case Parcel(s) Case No. Attachment B ZA24-0011 Page 1 SITE PLAN REVIEW SUMMARY Case No.: ZA24-0011 Review No.: Three Proiect Name: Site Plan — Restoration Church APPLICANT: John R. McAdams Co., Inc. Darren Andrews 4400 SH 121, Suite 800 Lewisville, TX 75056 Phone: (972) 436- 9712 Email: dandrews@mcadamsco.com Date of Review: 08/13/24 Owner: Restoration Church — Bryan Smith 1280 E. Highland St. Southlake, Texas 76092 Phone: 817.242.8530 Email: bsmith@restorationtx.com CITY STAFF HAS REVIEWED THE ABOVE REFERENCED PROJECT RECEIVED BY THE CITY ON 08/13/24 AND WE OFFER THE FOLLOWING STIPULATIONS. THESE STIPULATIONS ARE HEREBY MADE CONDITIONS OF SITE PLAN APPROVAL UNLESS SPECIFICALLY AMENDED BY THE CITY COUNCIL. IF YOU HAVE ANY QUESTIONS OR NEED FURTHER CLARIFICATION, PLEASE CONTACT MORGAN BARCLAY AT (817) 748-8127. Morgan Barclay Planning Technician (817) 748-8127 MBarclav(a)citvofsouthlake. com The drainage easement will be required to be abandoned and re -dedicated through an appropriate process prior to issuance of a building permit. 2. Correctly reflect all minimum yard/building lines. The minimum yard/building line along the boundaries adjacent to single family zoned (adjacent Highland Estates) per the Zoning Ordinance No. 480, as amended, Residential Adjacency Overlay, Section 43.13.a (8), is 40' unless the subject building is greater than 1 story or 20 feet in height, then the building must bet setback such that no portion of the building encroaches above a 4:1 slope from the residential property boundary. All other side yard(s) are a minimum of 15', front yard is 30' and the rear yard is 10'. The east boundary still shows a 15' side yard, where the minimum is 40' or a 4:1 slope from boundary. 3. Provide the existing, new and total floor area of the building(s). The response indicates this is provided, however, only building coverage is shown, no floor area is provided in the data summary. 4. All buildings must be designed such that no mechanical equipment (HVAC, etc.) or satellite dishes shall be visible. This shall include equipment on the roof, on the ground or otherwise attached to the building or located on the site. Please verify screening compliance. 5. Show the location, type, and height of all walls, fences, and screening devices for the development. Note whether existing or proposed. Per Section 39.6 of the Zoning Ord. No. 480, amended, where a non-residential use abuts a residentially zoned lot or tract or lot having an occupied residential dwelling, a minimum 8' solid fence meeting requirements of Section 39.2(b) must be provided along the side and rear boundary lines abutting the residential lot or dwelling unless a variance is approved by the City Council. (Variance Requested) Case No. Attachment C ZA24-0011 Page 1 6. Show any intended lighting. All lighting must comply with Lighting Ordinance No. 693, as amended regarding type of lighting, intensity, glare and spill -over. 7. All driveways must conform with Driveway Ordinance No. 634. The following needs to be addressed: a. The existing west driveway requires a minimum stacking depth of 75 feet measured from ROW per Section 5.2.d. This driveway as it currently exists has no stacking depth from the ROW. The proposed driveway increases stacking depth to approximately 50'. (Variance Requested) b. The re -striping plan at the transition area between E. Highland St. and E. Kirkwood Blvd. is subject to final design approval by the City Engineer prior to installation of the east driveway. Case No. Attachment C ZA24-0011 Page 2 Tree Conservation/Landscape Review Case No. ZA24-0011 Review No. One Dated: March 20, 2024 Number of Pages Project Name: Restoration Church (Site Plan) Contact: Keith Martin Phone: (817) 748-8229 Fax: (817) 481-5713 The following comments are based on the review of plans received on March 11, 2024. Comments designated with a number may be incorporated into the formal review to be considered by either the Planning and Zoning Commission or City Council. Other items will not be addressed by either the P&Z or City Council. It is the applicant's responsibility to contact the department representative shown above and make modifications as required by the comment. TREE CONSERVATION COMMENTS: * The proposed tree conservation complies with the Existing Tree Cover Preservation Requirements of the Tree Preservation Ordinance. There is 25% of existing tree cover on the site and a minimum of 60% is required to be preserved. A maximum of 18% is proposed to be removed, and a minimum of 82% is proposed to be preserved. * Except as provided by subsection 7.2.b. of the Tree Preservation Ordinance, a Tree Conservation Analysis or Tree Conservation Plan shall be approved if it will preserve existing tree cover in accordance with the percentage requirements established by Table 2.0. If the property has previously received a tree permit related to development, the percentage of existing tree cover at the time the first such permit was issued shall be used to calculate the minimum existing tree cover that must be preserved under this section. Table 2.0 — Existing Tree Cover Preservation Requirements Percentage of existing tree cover on the entire site 0% — 20% 20.1 — 40% 40.1 % - 60% 60.1 % - 80% 80.1 % - 100% Minimum percentage of the existing tree cover to be preserved* 70% 60% 50% 40% 30% *The minimum percentage of existing tree cover to be preserved shall exclude any area in public rights - of -way as approved by City Council. * Please be aware that all existing trees shown to be preserved on the City Council approved Tree Conservation Plan must be preserved and protected during all phases and construction of the development. Alteration or removal of any of the existing trees shown to be preserved on the approved Tree Conservation Plan is a violation of the Tree Preservation Ordinance and the zoning as approved by the Southlake City Council. Please ensure that the layout of all structures, easements, utilities, structures grading, and any other structure proposed to be constructed do not conflict with existing trees intended to be preserved. Case No. Attachment C ZA24-0011 Page 3 LANDSCAPE COMMENTS: * Per response letter, previous requirements have been met. * Indicates informational comment. # Indicates required items comment. Engineering/Public Works Review Contact: Sandy Endy, P.E. Email: sendy@ci.southlake.tx.us Phone: (817) 748-8033 GENERAL COMMENTS: * Retaining walls greater than 4' in height, measured from the bottom of footing to the top of pipe, will require a separate building permit. *Since there are no proposed public improvements, a separate public works permit is not required. The civil construction plans shall be submitted with the building permit. GRADING AND DRAINAGE: Provide a Drainage Area Plan sheet for both Existing and Proposed conditions and ensure that the associated flow calculations are also provided. * Per the Storm Drainage Policy, detention ponds shall be designed to contain the 100-year storm plus one foot of free board. *The drainage easement will be required to be abandoned and re -dedicated through separate instrument or by an appropriate replat. Case No. Attachment C ZA24-0011 Page 4 Lorenzo Chavez Deputy Fire Inspector Phone: (817) 748-8233 E-mail: LChavez@ci.southlake.tx.us Fire Department Review GENERAL COMMENTS: The Fire Department Connection for the sprinkler system must be within 100 feet of a fire hydrant, and within 50 feet of fire department fire lanes on the property. (FDC location not indicated on the plans) Add FDC location, wall mount or remote connection to meet the distance requirements or add a fire hydrant. FIRE LANE COMMENTS: Fire lanes require a minimum 30 foot inside turn radius and a minimum 54 foot outside turn radius. (Turn radii not indicated on plans) Fire apparatus access needs to be an all-weather surface, asphalt or concrete, 24 feet wide and able to support the imposed loads of fire apparatus. (Minimum of 85,000 pounds GVW) Concrete fire lanes shall be a minim 5" thick, 3,600 psi 5.5 sack concrete reinforced with #4 rebar @ 18" O.C. (plans indicate #3 rebar) FIRE HYDRANT COMMENTS: Fire hydrants are required at a maximum spacing of 300 feet for commercial locations that have both un- sprinklered and sprinklered buildings. (Plans indicate only one fire hydrant, which does not meet the distance requirements) Case No. Attachment C ZA24-0011 Page 5 General Informational Comments No review of proposed signs is intended with this site plan. A separate building permit is required prior to construction of any signs. All mechanical equipment must be screened of view from right-of-ways and residential properties in accordance with the Zoning Ordinance No. 480, as amended. All lighting must comply with the Lighting Ordinance No. 693, as amended. All development must comply with the Drainage Ordinance No. 605 and the Erosion and Sediment Control Ordinance No. 946, as amended. It appears that this property lies within the 65 LDN D/FW Regional Airport Overlay Zone and will require construction standards that meet requirements of the Airport Compatible Land Use Zoning Ordinance No. 479 and execution of an avigation easement and release. Development must comply with all requirements in Zoning Ordinance No. 480, Section 43, Overlay Zones. Denotes Informational Comment Case No. Attachment C ZA24-0011 Page 6 SURROUNDING PROPERTY OWNERS MAP & RESPONSES Restoration Church a 61 r � } t k 3 y hlakro I � � 14 — 4 4 I o y 6 � r i 7 g -o,,,r; h r L y HIGHLAND 5T 4 10 4 11 12 13 } Sovthlal� { �i �p ��• Baptistchurclr r SPO # Owner Zoning Address Acrea ge Resp onse CARROLL, ISD CS 1301 N CARROLL AVE 5.8907 NR 1. 39847 LORIO, SIDNEY SF1-A 1212 ASHMOORE CT 0.1463 NR 2. 4101 STEWART, KRISTOPHER SF1-A 1210 ASHMOORE CT 0.5788 NR 3. 69413 VAGHANI, BHUPAT SF1-A 1206 ASHMOORE CT 0.5956 NR 4. 79141 SCHULZ, RICHARD J SF1-A 1204 BLYTHE LN 0.5071 NR 5. 63136 MCLARTY, BRYAN SF1-A 1202 BLYTHE LN 1.0064 O 6. 96738 Case No. Attachment D ZA24-0011 Page 1 D'SOUZA, ADAM SF1-A 1200 BLYTHE LN 0.7888 NR 7. 1403 RESTORATION CHURCH CS 1282 E HIGHLAND ST 0.9963 NR 8. OF SOUTH LAK 2566 PST HOLDINGS LLC SP1 1201 N CARROLL AVE 0.2435 NR 9. 5704 CARROLL, ISD CS 1101 N CARROLL AVE 0.4031 NR 10. 86389 CARROLL, ISD CS 1301 E HIGHLAND ST 0.8061 NR 11. 28223 CARROLL, ISD CS 1335 E HIGHLAND ST 0.3465 NR 12. 79324 CARROLL, ISD AG 1349 E HIGHLAND ST 0.1280 NR 13. 21788 SCHMIDT, ROBERT SF1-A 1203 BLYTHE LN 1.0319 NR 14. 66429 BHAGAT, ALPA SF1-A 1350 E HIGHLAND ST 0.9009 NR 15. 95207 SNEAD, AUDRA SF1-A 1214 ASHMOORE CT 1.1165 NR 16. 45172 SOUTHLAKE, CITY OF AG 0.0691 NR 17. 02502 SOUTHLAKE, CITY OF AG 1371 E HIGHLAND ST 0.1265 NR 18. 7079 SUPERINTENDENT OF NR 19. CARROLL ISD RESTORATION CHURCH CS 1280 E HIGHLAND ST 6.9410 NR 1000 OF SOUTH LAK 41401 F: In Favor O: Opposed To U: Undecided NR: No Response Notices Sent: Sixteen (16) Responses Received within 300 feet: In Favor: 0 Opposed: 1 Undecided: 0 Surrounding Property Owner Responses Outside the Notice Area: In Favor: 0 Opposed: 1 Undecided: 0 Case No. Attachment D ZA24-0011 Page 2