Loading...
Item 6 - HteaO Plans05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 1 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 LOCATIONDAVIS BLVDW SO UT HLAKE BLV D 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 2 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 X-CUT FND 5/8" IRF5/8" IRF 302 307318 319 320 321 322 323 324 325 326 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 637 CURB LINE IS 3.5' OVER PROPERTY LINE ZONE "X" APPARENT PUBLIC ACCESS T 2" METAL PIPE 4"X4" METAL POST BASE4"X4" METAL POST BASE4"X4" METAL POST BASE T GMKD.R.T.C.T.WS"6 S"6 6"S S"6 6"S 6" S 6" S 6" S W W W W GGG G G G G G SILT FENCE LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD FSFSFSFSFSFSFSFSFSFSFSFSFS SF S F SFFS SFSFSF '00.0225.00'LODLODDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLLODLODLO D LODLODLODLODLODLOD LODLODLODDOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL LODDOL DOL DOL DOL DOL DOL LODLODLODLODLODDOL DOL LODSFSFSF SF SF FS FS FS FS FS FS FS FS SFSFSFSF SFGMK S UTILITY Water Line Electric Line Gas Line SIGN LOCATIONDISTANCE FROM PROPERTY LINE MONUMENT WALL SIGN WALL SIGN MENU SIGN ENTER SIGN EXIT SIGN 50’7’ 17’ 44’ 21’ 42’ A.1 A.2 B.1 C.1 D.1 D.2 EXIT SIGN 13’D.3 ENTER SIGN 53’D.4 SEATBACK DISTANCE FROM FM 1968 (DAVIS BOULEVARD) MONUMENT WALL SIGN ENTER SIGN140’95’ 35’ A.1 WALL SIGN 115’A.2 B.1 D.1 EXIT SIGN 70’D.2 EXIT SIGN 110’D.3 MENU SIGN 266’C.1 ENTER SIGN 51’D.4 B.1C.1 D.1D.3A.2A.1 44’ 53’50’ 7’ 21’ 42’ 13’ PROPERTY LINE10’ LANDSCAPE 5’ LANDSCAPE 50’ BUILDING SETBACK 40’ BUILDING SETBACK 15’ LANDSCAPE 24’ WIDE COMMON ACCESS EASEMENT 5’ X 10’ WATER EASEMENT 90’ BUILDING SETBACK 5’ LANDSCAPE 10’ TRAIL EASEMENT 15’ UTILITY EASEMENT D.2D.4 17’ 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 3 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 CHANNEL LETTER2" N.T.S.1/4" DRAIN HOLES LED .125" ALUMINUM CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT .063" ALUMINUM2" RETURN PRIMARY ELECTRICAL(NEC 600-5) SEE ELEC. NOTES FASTENERS ASREQ'D. BY LOCALJURISDICTION ALUMINUMENCLOSURE ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLYLISTED BUSHING 3/16" CLEAR LEXAN™ SPACER Reverse Lit Channel Letters w/ LED, Individually Mounted For Permit INTERNALLY ILLUMINATED REVERSE LIT CHANNEL LETTERS QUANTITY: ONE (1) Overall Height: 8’ Overall Length:11’ - 7” Total Sq.Ft.: 46.9 Face/Returns: Aluminum Finish Backs: Clear Lexan Backs Illumination: White premium LED NOTES: • Individually Mounted • WHITE interiors for increased illumination “BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters TOTAL SQ FT 46.9 A.1 A.1 NORTH ELEVATION A.1 11’-7” 8’0’-5” TOTAL BUILDING SQ. FT.: 2,030 84’-7”24’16’-1”8’11’-7” 7.0 SQ.FT. 4 65 1 14.4 SQ.FT. 3.8 SQ.FT. 1.3 SQ.FT. 3.0 SQ.FT.1.5 SQ.FT. W:34” H: 30”1 2 3 5 6 W:26” H: 80” W:22” H: 25” W:15” H: 15” W:21” H: 21” 4 W:47” H: 47” 3 2 15.6 SQ.FT. 7 7 W:38” H: 5” 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 4 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 CHANNEL LETTER2" N.T.S.1/4" DRAIN HOLES LED .125" ALUMINUM CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT .063" ALUMINUM2" RETURN PRIMARY ELECTRICAL(NEC 600-5) SEE ELEC. NOTES FASTENERS ASREQ'D. BY LOCALJURISDICTION ALUMINUMENCLOSURE ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLYLISTED BUSHING 3/16" CLEAR LEXAN™ SPACER Reverse Lit Channel Letters w/ LED, Individually Mounted For Permit INTERNALLY ILLUMINATED REVERSE LIT CHANNEL LETTERS QUANTITY: ONE (1) Overall Height: 6’ Overall Length:8’ - 8” Total Sq.Ft.: 27.4 Face/Returns: Aluminum Finish Backs: Clear Lexan Backs Illumination: White premium LED NOTES: • Individually Mounted • WHITE interiors for increased illumination “BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters TOTAL SQ FT 27.4 A.2 A.2 SOUTH ELEVATION SOUTH ELEVATION 8’-8” 10’-1” 6’ A.2 84’-7” 24’6’8’-8” 3.8 SQ.FT. 4 65 1 9.24 SQ.FT. 2.9 SQ.FT. 0.6 SQ.FT. 1.5 SQ.FT.0.8 SQ.FT. W:25” H: 22”1 2 3 5 6 W:19” H: 70” W:19” H: 22” W:11” H: 11” W:15” H: 15” 4 W:34” H: 36” 3 2 8.5 SQ.FT. 7 7 W:29” H: 3” 16’-1” 0’-4” 307318 319 320 321 322 323 324 325 326 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 637 CURB LINE IS 3.5' OVER PROPERTY LINE ZONE "X" T D.R.T.C.T.S"6 S"6 6"S S"6 6"S 6" S 6" S 6" S GGSILT FENCE FSFSFSFSFSFSFSFS SF S F SFFS SF'00.0225.00'DOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLLODLODLO D LODLODLODLODLODLOD LODLODLODDOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOLSFSFSFSFSFFSFSFSFSFS S 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 5 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 MONUMENT SIGNB.1 FRONT VIEW SECTION VIEW 14’8’-6”66”18”18”8’-6”16” Monument Sign • Reverse Lit Channel Letters w/ LED For Permit INTERNALLY ILLUMINATEDREVERSE LIT CHANNEL LETTER QUANTITY: (2) One per side Overall Height: 8'-6" Overall Length: 14' Sign Height:4'-5" Sign Length:6'-5” 16Total Sq.Ft.: Face: .125 Aluminum Returns: .063 Aluminum Illumination: White premium LED Pipe:6” Sq. TubeStructure:1 1/2” Steel Tube NOTES: • Individually Mounted • WHITE interiors for increased illumination • All paint two-stage automotive acrylic “BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters “Address” Non Illuminated Flush Mounted FCO Letters 2" N.T.S. 1/4" DRAIN HOLES LED .125" ALUMINUM CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT .063" ALUMINUM2" RETURN ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLY LISTED BUSHING .19" CLEAR LEXAN™ SPACER 1 1 2 2 N.T.S. MARQUEE CABINET • INTERNALLY ILLUMINATED • TYPICAL SECTION .063’’ ALUMINUM SIDE .063’’ ALUMINUM SIDE 2” RETAINERS 2” RETAINERS .125’’ ALUMINUM BAR 3/16’’ WHITE ACRYLIC 7328 LED 3/16’’ WHITE ACRYLIC 7328 LED ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLY 1” CHANNELS 1” CHANNELS INTERNALLY ILLUMIN For Permit ATED QUANTITY: (2) One per side Cabinet Height: 4’- 5” Cabinet Width: 6’ Illumination: White premium LED Monument Sign • Marquee Sign • LED Illuminated Cabinet Box 3 3 Monument Sign •Cabinet Box Double Sided • Internally Illuminated For Permit QUANTITY: (2) One per side Cabinet Height: 1’-6” Cabinet Width: 14’ Letters Height: 1’ Letters Width: 8’-1” .125 Aluminum / .5 White Acrylic 7328.063 Black &White AluminumFace: Sides:White Premium LEDIllumination: PUSH-THRU LETTERS SIGN INTERNALLY ILLUMINATED (TOP SECTION) N.T.S. PUSH-THRU CABINET • INTERNALLY ILLUMINATED • TYPICAL SECTION .063’’ ALUMINUM SIDE .063’’ ALUMINUM SIDE .125’’ ALUMINUM FACE .125’’ ALUMINUM BAR .125’’ ALUMINUM FACE .125’’ ALUMINUM BAR .125’’ ALUMINUM FACE .125’’ ALUMINUM FACE LED ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLY 1/2’’ WHITE ACRYLIC 7328 LED 1/2’’ WHITE ACRYLIC 7328 15’ LANDSCAPE PROPERTY LINE 24’ WIDE COMMON ACCESS EASEMENT 5’ X 10’ WATER EASEMENT 90’ BUILDING SETBACK X-CUT FND 5/8" IRF5/8" IRF 302 APPARENT PUBLIC ACCESS T 2" METAL PIPE 4"X4" METAL POST BASE4"X4" METAL POST BASE4"X4" METAL POST BASE GMK WW W W G G G G G LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD FSFSFSFS SFSF LODLODDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOL DOL DOL LODDOL DOL DOL DOL DOL DOL LODLODLODLODLODDOL DOL LODFS FS SFSFSFSF SFGMK B.1 21’ 6’-5”4’-5”1 2’ 7’ CONCRETE FOOTING 4000PSI 6” STEEL SQ TUBE 1/4” THICK FOOTING SPECIFICATIONSIGN LOCATION 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 6 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 MENU SIGNC.1 C.1 T Externally Illuminated Menu Sign For Permit QUANTITY: ONE (1) Overall Height: 7'-3”Menu Height:5'-0 3/4"Menu Length: 7’-6 1/2" 38.2otal Sq.Ft.: Face: .125" Aluminum Framming: NOTES: • The structure must be beige painted 1" Steel Angle Pole: 4" Sq. Steel Tube Menu board: 3/16" PVC 3’-113/4” 2’ 13” 2” 14”2’-5” 7’-61/2” 5’51/4” 7’-3” 1” Steel Angle Framing SIDE VIEWFRONT VIEW 4” Steel Sq. Tube .5 Steel Plate ULTIMATE SHEAR (IN CONCRETE) Anchor Diameter Embedment Depth Concrete Compressive Strength 3,000 psi 5/16” 1-3/4” 3,045 lbs. 3/8” 2-1/2” 5,955 lbs. 10% higher than wedge 28% higher than sleeve 1/2" 3” 11,960 lbs. equal to wedge 22% higher than sleeve QTY: 6 Pole Street Light Outdoor For Permit OUTDOOR ILLUMINATION QUANTIT :TWO (2) Wattage:65W Voltage:120V 60Hz Brightness:6670 lm Waterproof:IP65 Material:Aluminum PackageDimensions: 7.8" x 4.7" x 9.8” Certification:Certified by UL, DLC Premium, RoHS Compliant 2 2 1 1 05/01/23 Architect Firm: NA Architect: NA Engineer: NA Construction Co: NA General Contractor: NA Design Leader: Kat Sullon Design Team: Design Coord: 3D Rendering: Design View Print Mgr: Christina H Finishing Mgr: Gerry G CNC: David Paint: Admin: Marie Cuellar Project Mgr: Mark Song Assist Project Mgr: Victor Martins Master Electrician: Tomas Eggers Fabrication Mgr: Elizabeth Wright Installation Mgr: Mike R. 3D SCAN AERIAL FIELD CL PROVIDED AS NOTED 7 PERMIT SET HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092 • 3’-5” x 14“ x 7” • Cabinet painted with two-stage automotive acrylic • Cabinet Color : Black • Interior painted for increased illumination: white • Face: 3/16” White Acrylic 7328 • First Surface Fill: 3M Black Matte Cast Vinyl • Retainers: 1 1/2” Aluminum Angle • Pipe: 4” Sq. Aluminum Pipe • Total Sq. Ft.: 3.9 Illuminated Cabinet • Double Sided • Typical Section For Permit N.T.S. CABINET • INTERNALLY ILLUMINATED • TYPICAL SECTION .063’’ ALUMINUM SIDE .063’’ ALUMINUM SIDE 1 1/2” RETAINERS 1 1/2” RETAINERS .125’’ ALUMINUM BAR 3/16’’ WHITE ACRYLIC 7328 LED 3/16’’ WHITE ACRYLIC 7328 LED ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral Each sign must have: LED POWER SUPPLY BLACK CAST VINYL BLACK CAST VINYL DIRECTIONAL SIGNSD.1 D.2D.3 D.4 D.1 D.2 D.3 D.4 41“41“ 14”14” 46”46” ULTIMATE SHEAR (IN CONCRETE) Anchor Diameter Embedment Depth Concrete Compressive Strength 3,000 psi 5/16” 1-3/4” 3,045 lbs. 3/8” 2-1/2” 5,955 lbs. 10% higher than wedge 28% higher than sleeve 1/2" 3” 11,960 lbs. equal to wedge 22% higher than sleeve QTY: 4 ULTIMATE SHEAR (IN CONCRETE) Anchor Diameter Embedment Depth Concrete Compressive Strength 3,000 psi 5/16” 1-3/4” 3,045 lbs. 3/8” 2-1/2” 5,955 lbs. 10% higher than wedge 28% higher than sleeve 1/2" 3” 11,960 lbs. equal to wedge 22% higher than sleeve QTY: 4