Loading...
Item 6 - Demonstration and ExhibitsSIGN VARIANCE APPLICATION 1400 Main Street, Suite 310, Southlake, TX 76092 Phone: (817) 748-8215 Fax: (817) 748-8077 Revised January 2023 2 Demonstration Please demonstrate that the following conditions are applicable to the requested sign variance: 1.That a literal enforcement of the sign regulation will create an unnecessary hardship or practical difficulty on the applicant. 2.That the situation causing the unnecessary hardship or practical difficulty is unique to the affected property and is not self imposed. 3.That the variance will not injure and will be wholly compatible with the use and permitted development of adjacent properties. 4.That the variance will be in harmony with the spirit and purpose of the sign ordinance. N0°34'40"W625.37'TGSITE PLAN KEYNOTES 01 ACCESSIBLE CURB RAMP, REF. TO DTL. 05/A1.20 08 FDC MOUNTED TO BLDG. EXTERIOR WALL 02 ACCESSIBLE PARKING SIGNAGE, REF. TO DTL.03/A1.20 06 6" CONCRETE CURB, REF. TO DTL. 06/A1.20 03 PAINTED ACCESSIBLE PARKING SYMBOL, REF. TO DTL. 02/A1.20 07 LANDSCAPE AREA 09 FIRE HYRDRANT 10 PAD-MOUNTED TRANSFORMER, REFER TO MEP 05 PAINTED STRIPPING, REF. TO DTLS. 01 & 02/A1.20 04 WHEEL STOP, REF. TO DTL. 07/A1.20 GENERAL NOTES: 1. SIDEWALKS AND ACCESSIBLE ROUTES SHALL HAVE A RUNNING SLOPE NO GREATER THAN 1:20 (5%) AND A CROSS SLOPE NO GREATER THAN 1:48 (2%). 2. PROVIDE BOLLARDS AT ALL PAD MOUNTED TRANSFORMERS. 3. PROVIDE SIDEWALK EXPANSION JOINTS APPROXIMATELY 20' -30' O.C. 4. HOLD PAVEMENT 1/4" BELOW FINISH FLOOR AT ALL ENTRANCE DOORS. 11 POLE MOUNTED LIGHT FIXTURE, REF. TO DTL. 10/A1.20 12 GAS METER, REF. TO MEP 13 EXTENTS OF FIRE LANE, REF. CIVIL 15 MOTORIZED ROLLING ACCESS GATE 16 ACCESS CONTROL SLIDE GATE OPERATOR 17 6" DIA. STEEL PIPE BOLLARD SET IN 18" DIA. X 3'-6" DEEP CONC. PAINT DARK BRONZE WITH 4" YELLOW SAFETY STRIPE 14 8'-0" TALL MASONRY SCREEN WALL AND 5'-0" RETAINING WALL BY OTHERS A A B B C C D D E E 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A.5 C.8 D.5 7.5 7.5 B.7 B.1 C.3 7.6 7.6 7.22 7.3 7.3 B.5 C.5 01 03 04 02 02 03 01 03 04 02 02 01 03 04 02 02 03 05 05 03 05 07 07 07 07 07 07 07 07 07 07 07 07 07 07 07 0707070707 06 06 06 06 06 06 06 A1.20 17 C.4 C.7 D.2 D.8 7.87.98.1 PROPOSED WAREHOUSE W/ 2-STORY OFFICE BUILDING MSL = 678.00' F.F. = 100.00' INDUSTRIAL S.F. = 57,648 SF OFFICE S.F. = 22,967 SF TOTAL S.F. = 80,615 09 09 09 09 08 10 11 11 11 11 11 11 11 1111 1111 11 12 A1.21 01 0606 13 06 13 14 15 15 16 16 17 17 14 14 14 14 SD1.1 1 A1.21 4 A1.21 6 CHRISTOPHER SEAN O'BRIEN ARCHITECT REGISTRATION NO. 24878 COPYRIGHT © 2020 O'BRIEN THESE DRAWINGS, OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM, BY ANY METHOD, FOR ANY PURPOSE, WITHOUT THE PRIOR WRITTEN CONSENT FROM O'BRIEN SHEET NO. ISSUE DATE PROJECT # ISSUE NAME 5310 HARVEST HILL RD. SUITE 136 DALLAS, TX 75230 (972) 788-1010 www.obrienarch.com ISSUE LOG DATE DESCRIPTION 01/11/2021 ISSUE FOR BID & PERMIT 04/05/2021 ISSUE FOR CONSTRUCTION 11/11/2021 11:31:50AMC:\Users\billy.batac\Documents\A_202048 - GMi_ARCH_2020_Billy.Batac.rvt01/11/21 A1.10 GMI HEADQUARTERS 202048 OWNER REVIEW ARCHITECTURAL SITE PLAN 350 S. NOLEN DR. SOUTHLAKE, TEXAS 76092 A DEVELOPMENT OF: 350 S. NOLEN DR., SOUTHLAKE TEXAS 76092 1" = 20'-0"1 ARCHITECTURAL SITE PLAN NORTH 11 2 2 2 2 2 2 2 22 2 2 2 2 2 2 2 22 2 2 7 7 13 13 REVISION LOG DATE DESCRIPTION DELTA 03/18/2021 RESPONSE TO CITY COMMENTS 1 04/05/2021 ISSUE FOR CONSTRUCTION 2 09/21/2021 ASI #5 7 11/03/2021 TRUCK DOCK FENCE 13 Sign variance 03 A1.21 1' - 0" (STEEL PANEL) 2' - 6" (STEEL PANEL) 2' - 6" (STEEL PANEL) 2' - 6" (STEEL PANEL) 2' - 6"1' - 0" (CONCRETE PLINTH) 12' - 0" LENGTH10"1' - 4"10"02 A1.212' - 0"(CONCRETE PLINTH)3' - 0" DEPTH2' - 0"(4x) RECESSED UPLIGHTS SET WITHIN CONCRETE PLINTH -EACH ONE CENTERED AT EACH STEEL PANEL (3x) EMBED PLATES SET WITHIN CONCRETE PLINTH AT EQUAL SPACING TO PROVIDE WELD POINTS FOR SIGN MOUNTING. GRIND ALL WELDS AND EXPOSED EDGES SMOOTH. 2' - 3"EQ.EQ.EQ.2' - 3"2"6"6"2"(4X) 2" DIA. PVC PIPE AT EQUAL SPACING TO DRAIN TO RIVER ROCK BORDER 2' - 0" (CONCRETE PLINTH) 12' - 0" LENGTH 2' - 0" 03 A1.21 CONCRETE PLINTH W/ (3x) EMBED PLATES EQUALLY SPACED 1/2" THICK X 1'-0" WIDE CORTEN STEEL PANELS FRAMING TOP AND BOTH SIDES. GRIND ALL WELDS AND EXPOSED EDGES SMOOTH. (4x) INTEGRATED UPLIGHTS RECESSED WITHIN CONCRETE PLINTH -EACH ONE CENTERED AT EACH STEEL PANEL 1/2" THICK CORTEN STEEL PANELS WITH LETTER CUT OUTS. COORDINATE WITH OWNER TO PROVIDE CORRECT LOGO AND PLACEMENT. GRIND ALL WELDS AND EXPOSED EDGES SMOOTH. 5'-10 1/2"1'-0"12'-0" 11 3/4"10'-0 1/2"11 3/4" 2'-6 1/4" 2'-6" 2'-6" 2'-6 1/4" FINISH FLOOR 100' - 0" T.O. SIGN 106' - 10 1/2" T.O. BASE 101' - 0" 3' - 0"2"10"2' - 0"6"6" CONCRETE PLINTH OVER SREAD FOOTING (4x) RECESSED UPLIGHTS WITHIN CONCRETE PLINTH - EACH ONE CENTERED AT EACH STEEL PANEL 1/2" THICK CORTEN STEEL PLATES WITH LETTER CUTOUTS FRAMED BY 1/2" THICK X 1'-0" WIDE STEEL TOP AND BOTH SIDE PANELS. GRIND ALL WELDS AND EXPOSED EDGES SMOOTH. (3x) EMBED PLATES SET EQUALLY SPACED WITHIN CONCRETE PLINTH -WELD TO STEEL SIGNAGE. GRIND ALL WELDS AND EXPOSED EDGES SMOOTH. EQ.EQ. 2" DIA. PVC PIPE TO DRAIN ON EACH SIDE TO 24" WIDE RIVER ROCK BORDER 10"1' - 4"10" 24" WIDE BLACK RIVER ROCK BORDER AT ALL SIDES OF CONCRETE PLINTHFINISH FLOOR 100' - 0" T.O. SIGN 106' - 10 1/2" T.O. BASE 101' - 0" BACK FRONT PROVIDE SEALANT AT PERIMETER OF SIGN & CONCRETE A 1 2 2'-0"CLEAR OPENING - V.I.F.30'-0"V.I.F.15'-8 1/2"32" CLR. 4'-0"SLIDING GATE - CLOSED POSITION32'-0" TOTAL WIDTHDIRECTION TO OPEN GATESLIDING GATE - OPEN POSITION32'-0" TOTAL WIDTHFIRE LANE, REF. CIVIL30'-0" LANE WIDTH5 A1.21 6'-8" 4'-4" 1 2 CLR. 4'-0"4"4" 8" WIDE SCREEN WALL ELECTRICALLY- OPERATED SLIDING GATE A 7 7.3 DIRECTION TO OPEN GATE12'-2" 7'-4" 7 A1.21 2'-0" 24'-0"SLIDING GATE - CLOSED POSITION26'-0" TOTAL WIDTHSLIDING GATE - OPEN POSITION26'-0" TOTAL WIDTH2" 2'-4" 32" 7 7.3 12'-2" 7'-4" 8" WIDE SCREEN WALL ELECTRICALLY- OPERATED SLIDING GATE CHRISTOPHER SEAN O'BRIEN ARCHITECT REGISTRATION NO. 24878 COPYRIGHT © 2020 O'BRIEN THESE DRAWINGS, OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM, BY ANY METHOD, FOR ANY PURPOSE, WITHOUT THE PRIOR WRITTEN CONSENT FROM O'BRIEN SHEET NO. ISSUE DATE PROJECT # ISSUE NAME 5310 HARVEST HILL RD. SUITE 136 DALLAS, TX 75230 (972) 788-1010 www.obrienarch.com ISSUE LOG DATE DESCRIPTION 01/11/2021 ISSUE FOR BID & PERMIT 04/05/2021 ISSUE FOR CONSTRUCTION 11/11/2021 11:31:51AMC:\Users\billy.batac\Documents\A_202048 - GMi_ARCH_2020_Billy.Batac.rvt09/21/21 A1.21 GMI HEADQUARTERS 202048 MONUMENT SIGN DETAILS & GATE PLANS 350 S. NOLEN DR. SOUTHLAKE, TEXAS 76092 A DEVELOPMENT OF: 350 S. NOLEN DR., SOUTHLAKE TEXAS 76092 1/2" = 1'-0"01 MONUMENT SIGN PLAN 1/2" = 1'-0"02 MONUMENT SIGN FRONT ELEVATION 1/2" = 1'-0"03 MONUMENT SIGN SECTION PLAN NORTH TRUE NORTH 7 1/8" = 1'-0"4 ENLARGED SITE PLAN @ NORTH GATE 1/8" = 1'-0"5 PARTIAL WEST ELVN @ NORTH GATE 1/8" = 1'-0"6 ENLARGED SITE PLAN @ SOUTH GATE 1/8" = 1'-0"7 PARTIAL WEST ELVN @ SOUTH GATE 13 REVISION LOG DATE DESCRIPTION DELTA 09/21/2021 ASI #5 7 11/03/2021 TRUCK DOCK FENCE 13