Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ZA23-0046
PUBLIC HEARING NOTICE ZA23-0046 •Site Plan for Clariden Ranch School located on a property described as Lot 7, Block 1, Clariden Ranch Phase III, an addition to the City of Southlake, Denton County, Texas and located at 100 Clariden Ranch Road., Southlake, Texas. Current Zoning: “S-P-2” Generalized Site Plan District. SPIN Neighborhood #1 •Current Zoning: “S-P-2” Generalized Site Plan District •The purpose of this request is to consider the approval of a Site Plan to add a covered walkway between existing buildings on the site. Dear Property Owner: Your property has been identified as being within 300 feet of the above referenced Site Plan application. A public hearing will be held by the City of Southlake Planning and Zoning Commission on August 17, 2023 at 6:30 pm in the Town Hall Council Chambers at 1400 Main Street, Southlake, Texas. Please note that this letter and its attachments constitute written notice about the proposed Zoning Change. If you wish to register your opposition or support to this action, you may complete and send the Notification Response Form to the Planning & Development Services Department. You are encouraged to follow the request through final action because changes are often made during the review process. Please contact the Planning and Development Services Department if you have any questions: Project Contact: Reagan Rothenberger, Phone: (817) 748-8602 | Dept. Phone: (817) 748-8621 CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817) 748-8621 www.cityofsouthlake.com Planning and Zoning Commission Thursday, August 17, 2023 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZA23-0046 – Site Plan for Clariden Ranch School Meeting Date: August 17, 2023 at 6:30 PM PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Preliminary Plat referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s) whose name(s) are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817) 748-8621 REF.REF.J J J J GENERAL NOTES 1.REFER TO CIVIL, LANDSCAPE AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. 2.ALL EXTERIOR MOUNTED EQUIPMENT SHALL BE WEATHERPROOF TYPE. 3.ALL EXTERIOR ELECTRICAL OUTLETS SHALL BE WEATHERPROOF GFI TYPE. 4.ALL EXTERIOR LIGHTING SHALL BE CONTROLLED VIA CONTACTORS (PHOTOCELL ON/TIME CLOCK OFF) UNLESS OTHERWISE NOTED. 5.EMPTY CONDUIT SHALL BE CAPPED AT EACH END AND HAVE PULL STRING UNLESS OTHERWISE NOTED. 6.REFER TO ELECTRICAL FLOOR PLANS AND ARCHITECTURAL ELEVATIONS FOR EXTERIOR BUILDING MOUNTED LIGHTING LOCATIONS. 7.PROVIDE LARGE RADIUS 90 DEGREE SWEEPING BENDS FOR ALL U.G. CONDUITS. 8.THE ACRONYM "AHJ" AS INDICATED ON THIS PROJECT STANDS FOR "AUTHORITY HAVING JURISDICTION" 9.THE WORD "PROVIDE" MEANS: FURNISH, INSTALL AND MAKE FINAL CONNECTION TO THE EQUIPMENT PER THE EQUIPMENT MANUFACTURER'S SPECIFICATIONS, REQUIREMENTS, UL, NEC AND AHJ. 10.COORDINATE ALL SERVICES REQUIREMENTS WITH UTILITY COMPANIES AND INCLUDE ALL WORK REQUIRED IN BID. 11.UTILITIES INFORMATION ARE APPROXIMATELY SHOWN. FIELD VERIFY ALL LOCATIONS AND SITE CONDITIONS PRIOR TO BID/CONSTRUCTION. 12.PROVIDE FOR ALL EXPENSES TO RELOCATE/REMOVE EXISTING UTILITIES INCLUDING BUT ARE NOT LIMITED TO POWER, TELEPHONE, CABLE, ETC. PER UTILITY COMPANIES SPECIFICATIONS AND REQUIREMENTS. PROVIDE UNDERGROUND PULL BOXES AS REQUIRED. 13.VERIFY ALL SITE WORK REQUIRED TO BE DONE SUCH AS EXCAVATIONS, TRENCHES, CAISSONS, WALLS, ETC. FIELD SURVEY THE EXISTING SITE IN ORDER TO GAIN KNOWLEDGE OF THE EXISTING SITE CONDITIONS & ALL U.G. PIPING ON THIS PARTICULAR SITE. THE ENGINEERS ASSUME NO RESPONSIBILITY FOR DETERMINING ANY EXISTING U.G. PIPING LOCATIONS, SIZE, DEPTH OR HAZARD. CONTACT AND COORDINATE WITH THE UTILITY COMPANIES PRIOR TO DIGGING. 14.COORDINATE ALL ELECTRICAL UTILITY WORK WITH TRI-COUNTY ELECTRIC REPRESENTATIVE DANIEL BRADDOCK. EMAIL: DBRADDOCK@TCECTEXAS.COM; DIRECT: 817-752-8213; MOBILE: 817-475-6525. 15.FOR ALL UNDERGROUND ELECTRICAL FEEDERS ENCASE IN RED CONCRETE WITH A MINIMUM COVER OF 2'-0". 16.PROVIDE A MINIMUM OF 72 HOURS ADVANCED WRITTEN NOTICE TO OWNER FOR ANY NECESSARY UTILITY SERVICE DISRUPTIONS AND OBTAIN OWNER'S WRITTEN RESPONSE PRIOR TO PROCEEDING. 17.INSTALLED LIGHTING SYSTEMS AND LIGHTING CONTROLS SHALL ADHERE TO 2021 IECC REQUIREMENTS; PROVIDE NECESSARY CONTROL DEVICES, CONTROL WIRING, POWER SUPPLIES, RELAYS, ETC. AS REQUIRED TO MEET ALL REQUIREMENTS. PRIOR TO HAVING THE FINAL INSPECTION REQUESTED OR PERFORMED, THE GENERAL CONTRACTOR SHALL PROVIDE WRITTEN EVIDENCE TO THE PROJECT ARCHITECT THAT THE LIGHTING CONTROL SYSTEMS HAVE BEEN TESTED TO ENSURE THAT CONTROL HARDWARE AND SOFTWARE ARE CALIBRATED, ADJUSTED, PROGRAMMED AND IN PROPER WORKING CONDITION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND MANUFACTURER'S INSTRUCTIONS. THE GENERAL CONTRACTOR SHALL PROVIDE FOR ALL LIGHTING SYSTEMS REQUIRED FUNCTIONAL TESTING IN ACCORDANCE WITH 2021 IECC REQUIREMENTS BASED ON THE APPLICABLE CONTROL TYPE. THE GENERAL CONTRACTOR SHALL PROVIDE DOCUMENTS CERTIFYING THAT THE INSTALLED LIGHTING CONTROLS MEET DOCUMENTED PERFORMANCE CRITERIA OF THE 2021 IECC SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY; ALSO PROVIDE COPY OF INFORMATION PROVIDED TO OWNER TO PROJECT ARCHITECT. 18.ALL UNDERGROUND ELECTRICAL RACEWAY TO HAVE TRACER WIRE WITH TEST STATION OR LOCATABLE TAPE. VERIFY TEST STATION AND/OR LOCATABLE TAPE WORK AS INTENDED AFTER INSTALLATION. GYM ARTS LOWER SCHOOL ADMIN UPPER SCHOOL STEAM S2 S2 S2 (TYP.) (TYP.) (TYP.) (TYP.) E1D- 3 1 1 1 S2 2 KEY NOTES PROVIDE OUTDOOR RATED JUNCTION BOX FOR ROUGH-IN OF FUTURE GATE POWER. PROVIDE (1) CONDUIT FOR POWER AND (1) CONDUIT FOR DATA. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH TECHNOLOGY PLANS PRIOR TO ANY WORK AND PROVIDE FOR ACCORDINGLY. 1 SERVE CANOPY LIGHTS FROM EXISTING WALL PACKS AT STEAM BUILDING WITH CIRCUIT UPSH-1. 2 DATE: JOB NO. © WRA Architects, Inc. 2021 REVISIONS: WRA Architects, Inc. 12377 Merit Drive Suite 1800 Dallas, Texas 75251 214.750.0077 voice 214.750.5931 fax www.wraarchitects.com 7/7/2023 3:05:15 PMMEP100 Overall Site Plan -MEP 07/07/2023 2311SECURITY UPGRADES100 CLARIDEN RANCH RD. SOUTHLAKE, TX 760924141 Lindbergh Drive Addison, Texas 75001 Ph: 214.428.7744 Fax: 214.428.7770 www.mezaengineeringinc.com MEZA ENGINEERING, INC. Texas Registered Engineering Firm F-345 Project:23014.000 TRUE NORTH 1" = 40'-0"1 Overall Site Plan - MEP No. Date 2 3 4 5 6 A B C G J D E F H K R1 R2 2.9 4.1 4.5 A.1 .1 .2 .3 .4 .5 1 R1 R2 R6 R7 F2 F1 C14 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 GA GB GC C2 2 S211 1 S211 C1 G2.4 G3 G4 PONCE FUE SS E N G I N EE R I N G Project No. TX REG. # F-12125 Dallas, TX 752193333 Lee Parkway, Suite 475 469-310-2850 www.ponce-fuess.com DATE: JOB NO. © WRA Architects, Inc. 2021 REVISIONS: WRA Architects, Inc. 12377 Merit Drive Suite 1800 Dallas, Texas 75251 214.750.0077 voice 214.750.5931 fax www.wraarchitects.com 21044 7/7/2023 4:23:18 PMS210 OVERALL CANOPY ROOF PLAN 07/07/2023 2311SECURITY UPGRADES100 CLARIDEN RANCH RD. SOUTHLAKE, TX 760921" = 20'-0" 1 CANOPY ROOF - OVERALL No. Date STATEOFTEXASREGISTEREDPROFESSIONALENGINEERLUCAS G. PONCE 91119