Loading...
ZBA23-0019PUBLIC HEARING NOTICE ZBA23-0019 Dear Property Owner: A request for a Special Exception Use has been filed with the Board of Adjustment of the City of Southlake. The purpose of the hearing is to consider a request for a Special Exception Use, per Ordinance No. 480, as amended, Section 44.12(2) for an accessory structure greater than the size permitted on a property described as Lot 8, Block 1, Vermilion Addition – Southlake, an addition to the City of Southlake, Tarrant County, Texas, and located at 128 Vermilion Court, Southlake, Tarrant County, Texas. Current Zoning: “SF-1A” Single Family Residential District. SPIN District #11. The purpose of this request is to seek approval of a Special Exception Use to permit a is for a new garage that will cause the aggregate size of accessory buildings on the lot to exceed the maximum permitted 3%. It is estimated that the coverage exceeds the maximum permitted by approximately 150 square feet. If you wish to register your views on the matter, you may complete and send the enclosed Notification Response Form to the Planning & Development Services Department. You are encouraged to follow the requested action through final approval because changes are often made during the review process. Please note that this letter and its attachments constitute written notice about the proposed Variance. Please contact the Planning and Development Services Department if you have any questions: Project Contact: Reagan Rothenberger, E-mail: rrothenberger@ci.southlake.tx.us, Phone: (817) 748-8602. Dept. Phone: (817) 748-8621 CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817) 748-8621 Fax: (817) 748-8077 www.cityofsouthlake.com Board of Adjustment Thursday, August 24, 2023 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZBA23-0019 SEU for 128 Vermillion Ct. Meeting Date: August 24, 2023 at 6:30 PM Fill out: Owner: _____________________________ Address: ____________________________ City, State, Zip Code: __________________ PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Variance referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s) whose name(s) are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817)748-8621 Fax: (817)748-8077 E-mail: rrothenberger@ci.southlake.tx.us GarageGarageGarageGarageCarportCarportCarportCarportDateProject #IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. BUILDER TO VERIFY ALL ASPECTS OF PLANS PRIOR TO CONSTRUCTION.THESE DOCUMENTS ARE THE PROPERTY OF FARRIS DESIGN GROUP, LLC, THEY ARE NOT TO BE REPRODUCED OR REUSED, IN WHOLE IN OR PART, WITHOUT WRITTEN PERMISSION OF FARRIS DESIGN GROUP,LLC.HOUSE PLANSREMODELSADDITIONSLIGHT COMMERCIAL817-454-6043farrisdesigngroup@gmail.comSheet006 -29 -20231280 -1 -0623New Garage128 Vermillion CourtSouthlake, TxBuilding Area ScheduleNameAreaGarage896 SFCarport384 SFUnconditioned1280 SFTotal1280 SFSheet ListSheetSheet Name0 Cover0.1 Site Plan1 Floor Plan & Slab Plan2 Exterior Elevations3 Roof Plan & Electrical Plan & Building Section X XXX X X X X X X X X XX X XXX X X X X X X X X X XXXXXX XXX X X X X X X X X X X X X X X X X X XX XXX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XX X X X X X XX X XNORTH 5' - 0"40' - 0"5' Utility Easement40' Building Line15' Utility Easement15' - 0"20' - 0"20' Building Line10' P.A. & U.E.20' Building Line20' - 0"10' - 0"40' Building Line10' Utility Easement10' - 0"40' - 0"Southlake, Tx128 Vermilion Court128 VERMILION COURT30.045.030.033.225.828.688.825' - 0"Edge of PavementExisting FenceExisting Conc. Existing Conc. WalkExisting Single Story Residence32' - 0"72' - 0"40' - 5"40' - 0"New Conc. DriveNew Garage12' - 0"20' - 0"A/C UnitA/C Unit20' - 0"20' Building LineExisting PoolExistingD rainageExistingDrainageExistingDrainageExistingDrainage32' - 0"64' - 0"Existing FenceE x is tin g D ra in a g e E x i s t i n g D r a i n a g e 0° 00' 00"322.92'NE90° 00' 00"144.64'NE90° 00' 00"105.25'NER=L=67.00'71.63'0° 00' 00"268.57'NEscale1" = 20'-0"Site PlanDateProject #IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. BUILDER TO VERIFY ALL ASPECTS OF PLANS PRIOR TO CONSTRUCTION.THESE DOCUMENTS ARE THE PROPERTY OF FARRIS DESIGN GROUP, LLC, THEY ARE NOT TO BE REPRODUCED OR REUSED, IN WHOLE IN OR PART, WITHOUT WRITTEN PERMISSION OF FARRIS DESIGN GROUP,LLC.HOUSE PLANSREMODELSADDITIONSLIGHT COMMERCIAL817-454-6043farrisdesigngroup@gmail.comSheet0.106 -29 -20231280 -1 -0623New Garage128 Vermillion CourtSouthlake, Tx Wall TypesExterior2 x 4 Wood Framed Wall w/ Masonry VeneerNOTE: EXTERIOR WALL DIMENSIONS ARE AS FOLLOWSMASONRY FINISHTO THE EXTERIOR FACE OF MASONRYSection3GarageGarageGarageGarage10'-0" Plate Ht.CarportCarportCarportCarport10' Plate Ht32' - 0" OVERALL40' - 0" OVERALL32' - 0" OVERALL40' - 0" OVERALL1' - 4"29' - 4"1' - 4"1' - 4"10' - 8"3' - 0"15' - 0"7' - 0"3' - 0"12' - 0"28' - 0"10' - 0"15' - 0"7' - 0"1' - 4"10' - 8"12' - 0"28' - 0"AtticAccess13142200AServiceNOTE: THIS SLAB PLAN IS ISSUED TO AID THE CONTRACTOR WITH OFFSET DIMENSIONS. IT IS NOT AN ENGINEERED FOUNDATION PLAN.Drop andSlope Slab32' - 0" OVERALL40' - 0" OVERALL40' - 0" OVERALL32' - 0" OVERALL1' - 4"3' - 4"1' - 2"8' - 4"9' - 2"3' - 4"10 1/2"27' - 6 1/2"12' - 5 1/2"Masonry Ledge Masonry Ledge Drop andSlope SlabMasonry sits on Carport Slab12' - 5 1/2"27' - 6 1/2"1' - 10"16' - 4"1' - 10"10' - 2"1' - 10"9"30' - 6"9"12' - 5 1/2"3 1/2"26' - 6"9"Building Area ScheduleNameAreaGarage896 SFCarport384 SFUnconditioned1280 SFTotal1280 SFDoor ScheduleMark QuantitySizeType CommentsWidth Height1 2 3' - 0" 8' - 0" Ext. Entry2 1 16' - 0" 8' - 0" Overhead Door3 1 8' - 0" 8' - 0" Overhead Door4 1 10' - 0" 8' - 0" Overhead DoorDateProject #IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. BUILDER TO VERIFY ALL ASPECTS OF PLANS PRIOR TO CONSTRUCTION.THESE DOCUMENTS ARE THE PROPERTY OF FARRIS DESIGN GROUP, LLC, THEY ARE NOT TO BE REPRODUCED OR REUSED, IN WHOLE IN OR PART, WITHOUT WRITTEN PERMISSION OF FARRIS DESIGN GROUP,LLC.HOUSE PLANSREMODELSADDITIONSLIGHT COMMERCIAL817-454-6043farrisdesigngroup@gmail.comSheet106 -29 -20231280 -1 -0623New Garage128 Vermillion CourtSouthlake, Txscale1/4" = 1'-0"Floor Planscale1/4" = 1'-0"Slab & Plumbing Layout Fin FlrFin Flr10' -0" Plate Ht10' -0" Plate Ht8' -0" Head Ht8' -0" Head Ht10:1223' - 7" OVERALL HEIGHTBrick ColumnBrick1012101224Fin FlrFin Flr10' -0" Plate Ht10' -0" Plate Ht8' -0" Head Ht8' -0" Head Ht10:1210121012Brick ColumnBrick131Fin FlrFin Flr10' -0" Plate Ht10' -0" Plate Ht8' -0" Head Ht8' -0" Head Ht10:12BrickBrick Column10121012Fin FlrFin Flr10' -0" Plate Ht10' -0" Plate Ht8' -0" Head Ht8' -0" Head Ht1012101210:12BrickDateProject #IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. BUILDER TO VERIFY ALL ASPECTS OF PLANS PRIOR TO CONSTRUCTION.THESE DOCUMENTS ARE THE PROPERTY OF FARRIS DESIGN GROUP, LLC, THEY ARE NOT TO BE REPRODUCED OR REUSED, IN WHOLE IN OR PART, WITHOUT WRITTEN PERMISSION OF FARRIS DESIGN GROUP,LLC.HOUSE PLANSREMODELSADDITIONSLIGHT COMMERCIAL817-454-6043farrisdesigngroup@gmail.comSheet206 -29 -20231280 -1 -0623New Garage128 Vermillion CourtSouthlake, Txscale1/4" = 1'-0"Front Elevationscale1/4" = 1'-0"Right Elevationscale1/4" = 1'-0"Left Elevationscale1/4" = 1'-0"Rear Elevation GFIGFI20AGFIGFI220 50A20A220 50A3GDOGDO3BBBBBBWPWP 20A20ABBATTICGDOBGDOEAVEGFIWP220 50A20AWP 20ABATTIC3Section310' PLATE HT10' PLATE HT10' PLATE HT10' PLATE HT10' PLATE HT10' PLATE HT10' PLATE HT10' PLATE HT10:1210:1210:1210:12RIDGEHIPHIPHIPHIPFin FlrFin Flr10' -0" Plate Ht10' -0" Plate Ht8' -0" Head Ht8' -0" Head HtGarageGarageGarageGarage10'-0" Plate Ht.CarportCarportCarportCarport10' Plate HtAttic Space131101210121' - 0"200AServiceNOTE:Interior outlets & switches @ 46" AFFM4' Light in AtticSWITCHELECTRICAL PLAN LEGENDEAVE OUTLETGFI OUTLETWATER PROOF OUTLET220V 50Amp OUTLETGARAGE DOOR OPENER OUTLETRECESSED CAN LIGHT FIXTUREWALL MOUNTED LIGHT FIXTUREL.E.D. LIGHT FIXTURE (8' & 4' Lengths)ELECTRICAL PANEL20Amp OUTLETWATER PROOF 20Amp OUTLETEMPTY BOX FOR LOW VOLTAGEATTIC OUTLETWALL MOUNTED MOTION ACTIVATED LIGHT FIXTUREM3-WAY SWITCHNOTES: VERIFY LOCATION OF DATA AND PHONE OUTLETS, AND A/V EQUIPMENT WITH BUILDER AND OWNER PRIOR TO CONSTRUCTION.DateProject #IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO VERIFY AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. BUILDER TO VERIFY ALL ASPECTS OF PLANS PRIOR TO CONSTRUCTION.THESE DOCUMENTS ARE THE PROPERTY OF FARRIS DESIGN GROUP, LLC, THEY ARE NOT TO BE REPRODUCED OR REUSED, IN WHOLE IN OR PART, WITHOUT WRITTEN PERMISSION OF FARRIS DESIGN GROUP,LLC.HOUSE PLANSREMODELSADDITIONSLIGHT COMMERCIAL817-454-6043farrisdesigngroup@gmail.comSheet306 -29 -20231280 -1 -0623New Garage128 Vermillion CourtSouthlake, Txscale1/4" = 1'-0"Roof Planscale1/4" = 1'-0"Electrical & Lighting Layoutscale1/4" = 1'-0"Building Section