Item 9D - Alternative Plans06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
1
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
LOCATIONDAVIS BLVDW SO
UT
HLAKE BLV
D
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
2
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
X-CUT FND
5/8" IRF5/8" IRF
302
307318
319
320
321
322
323
324
325
326
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
637
CURB LINE IS 3.5'
OVER PROPERTY LINE
ZONE "X"
APPARENT
PUBLIC
ACCESS
T
2" METAL PIPE
4"X4" METAL POST BASE4"X4" METAL POST BASE4"X4" METAL POST BASE
T
GMKD.R.T.C.T.WS"6
S"6 6"S S"6 6"S
6"
S
6"
S
6"
S
W W W W
GGG G G
G
G
G
SILT FENCE LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
FSFSFSFSFSFSFSFSFSFSFSFSFS
SF
S
F
SFFS
SFSFSF
'00.0225.00'LODLODDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLLODLODLO
D
LODLODLODLODLODLOD
LODLODLODDOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOL
LODDOL DOL DOL DOL DOL DOL LODLODLODLODLODDOL DOL LODSFSFSF SF SF FS FS FS FS FS FS FS FS
SFSFSFSF SFGMK
S
UTILITY
Water Line
Electric Line
Gas Line
SIGN LOCATIONDISTANCE FROM PROPERTY LINE
MONUMENT
WALL SIGN
WALL SIGN
MENU SIGN
ENTER SIGN
EXIT SIGN
50’7’
8’
44’
16’
42’
A.1
A.2
B.1
C.1
D.1
D.2
EXIT SIGN 13’D.3
DRIVE-THRU SIGN 53’D.4
SEATBACK DISTANCE FROM
FM 1968 (DAVIS BOULEVARD)
MONUMENT
WALL SIGN ENTER SIGN140’95’
30’
A.1
WALL SIGN 115’A.2
B.1
D.1
EXIT SIGN 68’D.2
EXIT SIGN 110’D.3
MENU SIGN 266’C.1 DRIVE-THRU SIGN 51’D.4
B.1C.1 D.1D.3A.2A.1
44’
53’50’
7’
16’
42’
13’
PROPERTY LINE
10’ LANDSCAPE
5’ LANDSCAPE 50’ BUILDING SETBACK
40’ BUILDING SETBACK
15’
LANDSCAPE
24’ WIDE
COMMON
ACCESS
EASEMENT
5’ X 10’
WATER
EASEMENT
90’ BUILDING
SETBACK
5’
LANDSCAPE
10’ TRAIL
EASEMENT
15’ UTILITY
EASEMENT
D.2D.4
8’
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
3
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
CHANNEL LETTER2"
N.T.S.1/4" DRAIN HOLES
LED
.125" ALUMINUM
CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT
.063" ALUMINUM2" RETURN PRIMARY ELECTRICAL(NEC 600-5) SEE ELEC. NOTES
FASTENERS ASREQ'D. BY LOCALJURISDICTION
ALUMINUMENCLOSURE
ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral
Each sign must have:
LED POWER SUPPLYLISTED BUSHING
3/16" CLEAR LEXAN™
SPACER
NORTH ELEVATION
A.1
4”
171/4”
TOTAL BUILDING SQ. FT.: 2,030
84’-7”24’16’-1”
A.1 A.1
6’-6”
9’-5”Reverse Lit Channel Letters w/ LED, Individually Mounted, Remote Transformers • Front View
For Permit
INTERNALLY ILLUMINATED REVERSE LIT CHANNEL LETTERS
QUANTITY: ONE (1)
Overall Height: 6’ - 6”
Overall Length:9’-5”
Total Sq.Ft.: 61
Face/Returns: Aluminum Finish
Backs: Clear Lexan Backs
Illumination: White premium LED
NOTES:
• Individually Mounted
• WHITE interiors for increased illumination
“BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters
HTEAO CORPORATE STANDARD SIZE REQUIREMENT
Signature background wood to enhance HTeaO Texas logo signage.
9’-5”6’-6”
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
4
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
CHANNEL LETTER2"
N.T.S.1/4" DRAIN HOLES
LED
.125" ALUMINUM
CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT
.063" ALUMINUM2" RETURN PRIMARY ELECTRICAL(NEC 600-5) SEE ELEC. NOTES
FASTENERS ASREQ'D. BY LOCALJURISDICTION
ALUMINUMENCLOSURE
ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral
Each sign must have:
LED POWER SUPPLYLISTED BUSHING
3/16" CLEAR LEXAN™
SPACER
SOUTH ELEVATION SOUTH ELEVATION
8’-8”
10’-1”
6’
A.2
84’-7”
24’
307318
319
320
321
322
323
324
325
326
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
637
CURB LINE IS 3.5'
OVER PROPERTY LINE
ZONE "X"
T
D.R.T.C.T."6
S"6 6"S S"6 6"S
6"
S
6"
S
6"
S
SILT FENCE
FSFSFSFSFSFSFS
SF
S
F
SFFS
SF'00.0225.00'DOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLLODLODLO
D
LODLODLODLODLODLOD
LODLODLODDOL DOL DOL DOL DOL DOL DOL DOL DOL DOL DOLSFSFSFSFSFFSFSFSFS
Reverse Lit Channel Letters w/ LED, Individually Mounted, Remote Transformers • Front View
For Permit
INTERNALLY ILLUMINATED REVERSE LIT CHANNEL LETTERS
QUANTITY: ONE (1)
Overall Height: 6’
Overall Length:8’ - 8”
Total Sq.Ft.: 52
Face: .125 Aluminum Aluminum Finish
Returns: .063 Aluminum Aluminum Finish
Backs: Clear Lexan Backs
Illumination: White premium LED
NOTES:
• Individually Mounted
• WHITE interiors for increased illumination
“BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters
8’-8”
6'
A.2A.2
35/8”
157/8”
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
5
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
MONUMENT SIGN15’
LANDSCAPE
PROPERTY
LINE
24’ WIDE
COMMON
ACCESS
EASEMENT
5’ X 10’
WATER
EASEMENT
90’ BUILDING
SETBACK
X-CUT FND
5/8" IRF5/8" IRF
302
APPARENT
PUBLIC
ACCESS
T
2" METAL PIPE
4"X4" METAL POST BASE4"X4" METAL POST BASE4"X4" METAL POST BASE
GMK WW W W W
GG G G
G
G
G LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD
FSFSFSFSFSFS
SFSF
LODLODDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOLDOL DOL DOL DOL DOL
LODDOL DOL DOL DOL DOL DOL LODLODLODLODLODDOL DOL LODFS FS FS
SFSFSFSF SFGMK
B.1
16’
SIGN LOCATION
B.1 FRONT VIEW SIDE VIEW
FOOTING SPECIFICATION
2"
N.T.S.
1/4" DRAIN HOLES
LED
.125" ALUMINUM
CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT
.063" ALUMINUM2" RETURN
ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral
Each sign must have:
LED POWER SUPPLY
LISTED BUSHING
.19" CLEAR LEXAN™
SPACER
Monument Sign • Reverse Lit Channel Letters w/ LED
For Permit
INTERNALLY ILLUMINATEDREVERSE LIT CHANNEL LETTER
QUANTITY: (2) One per side
Overall Height: 5'-6”
Overall Length: 7'-11 5/8”
44Total Sq.Ft.:
Face: .125 Aluminum
Returns: .063 Aluminum
Illumination: White premium LED
NOTES:
• Individually Mounted
• WHITE interiors for increased illumination
•
All paint two-stage automotive acrylic
“BORN IN TEXAS 2009” Non Illuminated Flush Mounted FCO Letters
Monument Sign •Cabinet Box Double Sided • Internally Illuminated
For Permit
QUANTITY: (1) One
Cabinet Height: 8’-0”
Cabinet Width: 10’
Total Sq. Ft.: 80
Pipe: 6” Sq. Steel Tube
.125 Aluminum
.2” Steel Angle
Face:
Structure:
3M Premium Print VinylFirst Surface:
7”2”
CONCRETE FOOTING4000PSI
6” STEEL SQ TUBE1/4” THICK
7’-115/8”5’-6”2
11’-6”2”2”
NOTES:
“190” Cut out Letters Internally Illuminated8’10’6’6”1’-6”5’-6”8”171/2”6”
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
6
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
MENU SIGNC.1
C.1
T
Externally Illuminated Menu Sign
For Permit
QUANTITY: ONE (1)
Overall Height: 7'-3”Menu Height:5'-0 3/4"Menu Length: 7’-6 1/2"
38.2otal Sq.Ft.:
Face: .125" Aluminum
Framming:
NOTES:
• The structure must be beige painted
1" Sq. aluminum Angle
Pole: 4" Sq. Steel Tube
Menu board: 3/16" PVC
3’-113/4”
2’
13”
2”
14”
7’-61/2”
5’51/4”
7’-3”
1” Sq. Angle Aluminum Framing
SIDE VIEWFRONT VIEW
4” Steel Sq. Tube
.5 Steel Plate
ULTIMATE SHEAR (IN CONCRETE)
Anchor
Diameter
Embedment
Depth
Concrete
Compressive Strength
3,000 psi
5/16” 1-3/4” 3,045 lbs.
3/8” 2-1/2” 5,955 lbs.
10% higher than wedge
28% higher than sleeve
1/2" 3” 11,960 lbs.
equal to wedge
22% higher than sleeve
QTY: 6
Pole Street Light Outdoor
For Permit
OUTDOOR ILLUMINATION
QUANTIT :TWO (2)
Wattage:65W
Voltage:120V 60Hz
Brightness:6670 lm
Waterproof:IP65
Material:Aluminum
PackageDimensions: 7.8" x 4.7" x 9.8”
Certification:Certified by UL, DLC Premium,
RoHS Compliant
2
2
1
12’-5”
ALL HTEAO STANDARD MENU SIGNAGE
06/13/23
Architect Firm: NA
Architect: NA
Engineer: NA
Construction Co: NA
General Contractor: NA
Design Leader: Kat Sullon
Design Team:
Design Coord:
3D Rendering:
Design View
Print Mgr: Christina H
Finishing Mgr: Gerry G
CNC: David
Paint:
Admin: Marie Cuellar
Project Mgr: Mark Song
Assist Project Mgr: Victor Martins
Master Electrician: Tomas Eggers
Fabrication Mgr: Elizabeth Wright
Installation Mgr: Mike R.
3D SCAN
AERIAL
FIELD
CL PROVIDED
AS NOTED
7
PERMIT SET
HTEAO SIGN PACKAGE • 190 DAVIS BLVD, SOUTHLAKE, TX 76092
• 3’-0” x 14“ x 7”
• Cabinet painted with two-stage automotive acrylic
• Cabinet Color : Black
• Interior painted for increased illumination: white
• Face: 3/16” White Acrylic 7328
• First Surface Fill: 3M Black Matte Cast Vinyl
• Retainers: 1 1/2” Aluminum Angle
• Pipe: 4” Sq. Aluminum Pipe
• Total Sq. Ft.: 3.9
Illuminated Cabinet • Double Sided • Typical Section
For Permit
N.T.S.
CABINET • INTERNALLY ILLUMINATED • TYPICAL SECTION
.063’’ ALUMINUM SIDE
.063’’ ALUMINUM SIDE
1 1/2” RETAINERS 1 1/2” RETAINERS
.125’’ ALUMINUM BAR
3/16’’ WHITE ACRYLIC 7328
LED
3/16’’ WHITE ACRYLIC 7328
LED
ELECTRICAL NOTESSign Company DOES NOT provide primary electrical to sign.Power to the sign must be done by a licensed electrical contractor or licensed electrician.1. A minimum of one dedicated 120V 20A circuit2. Junction box installed within 6 feet of sign3. Three wires: Line, Ground, Neutral
Each sign must have:
LED POWER SUPPLY
BLACK CAST VINYL
BLACK CAST VINYL DIRECTIONAL SIGNS41“41“
14”14”
D.1 D.2 D.3 D.4
36”36”
41“
14”
36”
ULTIMATE SHEAR (IN CONCRETE)
Anchor
Diameter
Embedment
Depth
Concrete
Compressive Strength
3,000 psi
5/16” 1-3/4” 3,045 lbs.
3/8” 2-1/2” 5,955 lbs.
10% higher than wedge
28% higher than sleeve
1/2" 3” 11,960 lbs.
equal to wedge
22% higher than sleeve
QTY: 4
D.1
D.2
D.3
D.4