Loading...
Item 9A - ExhibitsBabendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Signage & Wayfinding Design Specialists 1 Site Signage Presentation March 27, 2023 PZ & Sign Board Comments Incorporated Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 2 Plat Plan LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 3 Sign Location Plan 01 14 12 15 16 22 09 23 19.1 19.3 19.2 17 13 07 21A 04 05 03 BA02 08 06 ENTRANCE4 ENTRANCE3 ENTRANCE2 ENTRANCE1 18 03.1 03.3 03.2B A 21B LEGEND New Sign and Foundation Remove and Replace Remove Sign and Base Existing Sign to Remain Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 4 Location 01 Secondary Monument Originally Proposed to Sign Board & PZ Highland Road Front Elevation Scale: 1/2"=1'-0"1 421 / 441 EMERGENCY Entrance 41'-6"Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white6"10'-0" 8'-4" 5'-9 1/2"5 1/2"5'-2"8'-2 1/2"Secondary Monument Internally-Illuminated Total Sign Area: 8'-3" height x 10'-0" wide = 82.5 sq ft area per side Panel Area: 5'-2" height x 8'-4" wide = 43 sq ft area per side Logo Area: 1'-6" height x 5'-9 1/2" wide = 8.6875 sq ft (20.2% of sign face) Stone Surround: 10" surround to match architecture Illumination: Internally-illuminated letters8"New Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 5 Location 01 Option A.2 Secondary Monument Highland Road Front Elevation Scale: 1/2"=1'-0"1 421 / 441 EMERGENCY Entrance 4 Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white Secondary Monument Internally-Illuminated Total Sign Area: 7'-2" height x 8'-8 1/2" wide = 62.4 sq ft area per side Panel Area: 4'-6" height x 7'-3" wide = 32.7 sq ft area per side Logo Area: 1'-3 1/2" height x 5'-9 1/2" wide = 7.48 sq ft (22.8% of sign face) Stone Surround: 8 3/4" surround to match architecture Illumination: Internally-illuminated letters 8'-8 1/2"4'-6"7'-2"5 1/4"5'-0" 7'-3 1/8"1'-3 1/2"8"4 3/4"New Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 6 16'-6"3'-4 3/4"Location 01 - DETAIL Property Line Location 01 - DETAIL Secondary Monument Highland Road Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 7 Location 02 Vehicular Directional Service & Delivery Ambulance EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Hospital Professional Bldg. Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base Replacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 8 Location 03 Vehicular Directional Service & Delivery Ambulance EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Back Elevation Scale: 3/4"=1'-0"2 Service & Delivery Ambulance EMERGENCY Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 9 Location 03.1 Emergency Letters Front Elevation Scale: 3/16"=1'-0"3 EMERGENCY Front Elevation Scale: 1"=1'-0"1 Side Section Scale: 1 1/2"=1'-0"2 5'-9 3/4"8"1 Center Between Columns 1 Center on Canopy FaceNew SignExisting Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 10 Front Elevation Scale: 3/16"=1'-0"2 AMBULANCE Front Elevation Scale: 1"=1'-0"1 Side Section Scale: 1 1/2"=1'-0"2 5'-11 3/4"8"Center on Canopy Face1 1 Center Between Columns Location 03.2 Ambulance Letters Existing SignExisting Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 11 Location 03.3 Monument Letters Existing Sign South Elevation Scale: 1/4"=1'-0"2 North Elevation Scale: 1/4"=1'-0"3 Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 11'-0"7'-2"10"1'-6"4'-6"4'-6"8'-6" 1 1 2 4" 9'-6"3'-6" Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 12 Location 04 Secondary Monument Originally Proposed Sign Board & PZ Highland Road Front Elevation Scale: 1/2"=1'-0"1 421 / 441 Entrance 3 EMERGENCY1'-6"Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white6"10'-0" 8'-4" 5'-9 1/2"5 1/2"5'-2"8'-2 1/2"Secondary Monument Internally-Illuminated Total Sign Area: 8'-3" height x 10'-0" wide = 82.5 sq ft area per side Panel Area: 5'-2" height x 8'-4" wide = 43 sq ft area per side Logo Area: 1'-6" height x 5'-9 1/2" wide = 8.6875 sq ft (20.2% of sign face) Stone Surround: 10" surround to match architecture Illumination: Internally-illuminated letters8"New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 13 Location 04 Option A.1 Secondary Monument Highland Road Front Elevation Scale: 1/2"=1'-0"1 EMERGENCY Entrance 3 421 / 441 1'-6"Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white6"10'-0" 8'-4" 5'-9 1/2"5 1/2"Secondary Monument Internally-Illuminated Total Sign Area: 7'- 3" height x 10'-0" wide = 73 sq ft area per side Panel Area: 5'-2 3/4" height x 8'-4" wide = 43.6 sq ft area per side Logo Area: 1'-6" height x 5'-9 1/2" wide = 8.6875 sq ft (20% of sign face) Stone Base: 8 3/4" base to match architecture Illumination: Internally-illuminated letters8"7'-3"5'-2 3/4"New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 14 Location 04 Option A.2 Secondary Monument Highland Road Front Elevation Scale: 1/2"=1'-0"1 421 / 441 EMERGENCY Entrance 3 Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white Secondary Monument Internally-Illuminated Total Sign Area: 7'-2" height x 8'-8 1/2" wide = 62.4 sq ft area per side Panel Area: 4'-6" height x 7'-3" wide = 32.7 sq ft area per side Logo Area: 1'-3 1/2" height x 5'-9 1/2" wide = 7.48 sq ft (22.8% of sign face) Stone Surround: 8 3/4" surround to match architecture Illumination: Internally-illuminated letters 8'-8 1/2"4'-6"7'-2"5 1/4"5'-0" 7'-3 1/8"1'-3 1/2"8"4 3/4"New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 15 16'-6"3'-4 3/4"Property Line Location 04 - DETAIL Location 04 - DETAIL Secondary Monument Highland Road Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 16 Location 05 Vehicular Directional Hospital Service & Delivery EMERGENCY Ambulance Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Professional Bldg. Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 17 North Elevation Scale: 3/32"=1'-0"2 Front Elevation Scale: 1/4"=1'-0"1 Total Sign Area: 8'-0" height x 31'-0" wide = 248 sq ft area Illumination: Internally-illuminated 31'-0"8'-0"3'-11"1'-2 3/4"Existing logo Replacement internally-illuminated building-mounted letters 22'-7" Location 06 Building-Mounted Logo Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 18 Location 07 Vehicular Directional Professional Bldg. Hospital EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 19 North Elevation Scale: 3/32"=1'-0"2 Front Elevation Scale: 1/2"=1'-0"1 Total Sign Area: 4'-0" height x 15'-6" wide = 62 sq ft area Illumination: Internally-illuminated 15'-6"4'-0"1'-11 1/2"7 3/8"Existing logo Replacement internally-illuminated building-mounted letters Location 08 Building-Mounted Logo Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 20 Front Elevation Scale: 1/2"=1'-0"1 421 Total Sign Area: 3'-4" height x 10'-0" wide = 33 sq ft area Illumination: Non-illuminated 1/8" thick applied flat-cut logo and text Front Elevation Scale: 1/4"=1'-0"2 421 10'-0"3'-4"8'-8"2'-3"8"1'-1 1/8"4 1/8"Location 09 Entrance Originally Proposed to Sign Board & PZ New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 21 Front Elevation Scale: 1/2"=1'-0"1 421 Total Sign Area: 2'-3" height x 8'-8" wide = 19.5 sq ft area Illumination: Non-illuminated 1/2" thick applied flat-cut logo and 1/4” text stud mounted. Front Elevation Scale: 1/4"=1'-0"2 421 8'-8"2'-3"8"1'-1 1/8"4 1/8"Location 09 Option A.1 Entrance New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 22 Location 12 Building-Mounted Logo Front Elevation Scale: 1/2” = 1’ -0”1 Total Sign Area: 3'-0" height x 15'-2 7/8" wide = Approx. 46 sq ft area Illumination: Internally-illuminated Internally-illuminated building-mounted logo 15'-2 7/8"3'-0"2'-1"Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 23 Location 13 Building-Mounted Logo Front Elevation Scale: 1/2” = 1’ -0”1 Total Sign Area: 3'-0" height x 15'-2 7/8" wide = Approx. 46 sq ft area Illumination: Internally-illuminated Internally-illuminated building-mounted logo 15'-2 7/8"3'-0"2'-1"Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 24 Location 14 Vehicular Directional Professional Bldg. Hospital EMERGENCY Exit Hwy. 114 Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 25 Location 15 Vehicular Directional Exit Hwy. 114 EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 26 Location 16 Vehicular Directional EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Professional Bldg. Hospital Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 27 Location 17 Vehicular Directional Professional Bldg. Exit Hwy. 114 Hospital Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround 9"1/8"1/8"6"3"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Painted aluminum base New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 28 Location 18 Remove & Do Not Replace Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 29 Location 19 Primary Monument Hwy. 114 Access Road 421 / 441 Entrance 2 EMERGENCY Front Elevation Scale: 3/8"=1'-0"1 Primary Monument Internally-Illuminated Stone veneer to match existing Double-faced internally-illuminated sign panel Double-faced internally-illuminated EMERGENCY panel, red and white8"2'-3"15'-0" 12'-6" 8'-8 1/2"12'-0"7'-5"10"8"Total Sign Area: 12'-0" height x 15'-0" wide = 180 sq ft area per side Panel Area: 7'-5" height x 12'-6" wide = 92.7 sq ft area per side Logo Area: 2'-3" height x 8'-8 1/2" wide = 19.6 sq ft (21.1% of sign face) Stone Surround: 15" surround to match architecture Illumination: Internally-illuminated letters New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 30 Location 19 - DETAIL Primary Monument Hwy. 114 Access Road Location 19 - DETAIL 41'-1 0 3/4"10'-6 7/8"Property Line Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 31 LOCATION OPTION 19.3 Location 19 Primary Monument Hwy. 114 Access Road Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 32 Front Elevation - Sign 21A Scale: 1/2"=1'-0"1 Front Elevation - Sign 21B Scale: 1/2"=1'-0"2 Entrance 1 Total Sign Area - Sign 21A: 3'-1/4" height x 17'-0" wide = 51.35 sq ft area Logo Area: 2'-10 1/2" height x 11’-1 1/2" wide = 31.98 sq ft (62% of sign face) Illumination: Internally-illuminated letters Total Sign Area - Sign 21B: 1'-3" height x 8'-3 1/4" wide = 10.34 sq ft area Illumination: Non-illuminated letters 17'-0" 11'-1 1/2"3'-0 1/4"1'-5"7 3/4"2'-10 1/2"Existing internally illuminated logo Replacement flat letters Flat letters on stone wall8'-3 1/4"1'-3"Sign 21A Sign 21B Location 21 Water Wall Monument New Sign Replacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 33 Location 22 Vehicular Directional Professional Bldg. Hospital EMERGENCY Front Elevation Scale: 3/4"=1'-0"1 Side Elevation Scale: 3/4"=1'-0"2 Total Sign Area: 5'-0" height x 4'-0" wide = 20 sq ft area per side Panel Area: 3'-4" height x 4'-0" wide = 13.33 sq ft area per side Illumination: Non-illuminated, reflective Emergency vinyl Does Not Meet City of Southlake Code • 4 sq ft sign panel per face (13.33 as shown) • 10 sq ft total sign area (20 as shown) • 3’ maximum height (5’ as shown) • If visible from the street, 6” stone surround If not visible from the street, 6” sign structure surround4"9"1/8"1/8"6"3"1'-1"1"3'-4"4'-6"4'-0" Internal Site Vehicular Directional Non-Illuminated Reflective vinyl EMERGENCY field and text Painted aluminum base Replacement SignReplacement Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 34 Front Elevation - Option A Scale: 1/2"=1'-0"1 Next 2 Rights 3'-9"11'-0"Front Elevation - Option B Scale: 1/2"=1'-0"2 Medical Center Next 2 Rights 3'-9"11'-0"Location 23 City of Southlake Wayfinding New SignNew Sign Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 35 Location 23 Babendure Design Group 8140 Walnut Hill Ln. #950 Dallas, Texas 75231 214.265.1960 www.babendure.com Methodist Southlake Medical Center March 27, 2023 36 Existing Blue H