Item 6B - PlansDates:
Project Start Date:
Project Information:
CAD File Name:
Designed By:
This drawing checked by:
Sheet Number:The Madhani ResidenceProject No:2037Christopher D. Hough
Madhani V4CD DV.pln
A1-01Project Status:Construction Documents2260 JOHNSON ROADSOUTHLAKE, TX, 76092596 North KimballSuite 100Southlake, Texas 76092817 ¥ 988 ¥ 9680 (OFFICE)www.HeritageDesignStudio.comoffice@HeritageDesignStudio.comJune 16th, 2021
Date of Issue:
Wednesday, December 21, 2022Design Version No: Version 4File last saved on:
12/21/22, 4:16 PM
/Users/shawn/Heritage Office Dropbox/Heritage Data/
PROJECTS/FINISHED PROJECTS/2137 Madhani/
ArchiCAD/Madhani V4CD DV.pln
File Path:
Project Version Number:
Version 4
Sheet Name:SITE PLAN
FOR
CONSTRUCTION
12-21-22
S 8 5 ° 5 0 ' 5 9 " W
3 5 .3 5 '
S 88° 49' 52" W
120.83'
N 89° 36' 41" W
23.81'S 44° 24' 31" W
12.48'N 0° 21' 30" W356.89'N 89° 23' 2" E188.09'S 0° 27' 30" E345.14'N 88° 49' 52" E
188.71'15'-71/2"3'-111/2"11'-8"31'-21/2"26'-81/2"31'-21/2"
48'-0"48'-0"
20'-0"
20'-0"124'-75/8"23'-13/8"103'-11/4"50'-25/8"
45'-7/8"46'-87/8"40'-0"101'-103/8"35'-0"76'-33/4"
65'-0"8'-81/4"63'-0"5'-0"14'-0" (TYP.)35'-0"28'-0"14'-0"28'-0"
20'-0"20'-0"20'-0"
91'-93/4"167'-13/4"
6'-0"32'-41/8"5'-0"10'-0"15'-0"
5'-0"
1 1 '-11/2 "5'-0"Rad. = 25'-0"Rad. = 25'-0"
Rad. = 3'-0"Rad. = 3'-0"
Rad. = 5'-0"Rad. = 5'-0"
40' FRONT YARD
SETBACK
20' SIDE YARD SETBACK
50' FRONT/SIDE YARD
SETBACK
40' REAR YARD SETBACK
EMBEDDED LED DRIVEWAY
UP LIGHTS @ 10'-0" O.C.
24"x24" 8' COLUMN W/
STUCCO EXTERIOR
7'-6" WROUGHT IRON FENCE
PER SECTION 39.5.c.4
SLIDING MOTOR COURT
GATE - TO BE SELECTED BY
OWNER
CONCRETE MOTOR COURT
W/ BRICK BORDER
CONCRETE DRIVE & MOTOR
COURT
EXISTING DRAIN
EXISTING DRAIN
EXISTING DRAIN
STORM ROOM
EXISTING CONCRETE SIDEWALK
(VARIABLE WIDTH)
PROPOSED NEW 5'
CONCRETE SIDEWALK
EXISTING CONCRETE
SIDEWALK
FIRE HYDRANT
7'-6" WROUGHT IRON FENCE
PER SECTION 39.5.c.4
7'-6" WROUGHT IRON FENCE
PER SECTION 39.5.c.4
EXISTING WATER METER TO BE
RELOCATED OUTSIDE OF
PROPOSED DRIVEWAY BY OWNER
RIGHT-OF-WAY DEDICATION
(1,548 SQ. FT.) (BY THIS PLAT)
5' UTILITY EASEMENT (BY THIS
PLAT)
15' UTILITY EASEMENT (BY THIS
PLAT) 15' WATER EASEMENT
15' UTILITY EASEMENT (BY THIS
PLAT) 15' WATER EASEMENT
PROPOSED NEW WATER
METER LOCATION
JOHNSON ROAD RANDOL MILL AVENUEPER SF-1A ZONING
66,727 SQ. FT. (1.53 ACRES)
20% MAX LOT COVERAGE
40' FRONT SETBACK
20' SIDE SETBACK
40' REAR SETBACK
*50' SETBACK ALONG RANDOL MILL
EXISTING
STORAGE
BUILDING - TO BE
REMOVED
POOL -
BY
OTHER
PROPOSED 2-STORY
RESIDENCE
COVERAGE SUMMARY
LOT SQUARE FOOTAGE: 66,727 SQ. FT.
RESIDENCE COVERAGE: 7,950 SQ. FT.
% OF LOT COVERED: 11.9%
FOUNTAIN
F.F.E. +1'-9"
A/C
A/C
A/C
A/C
POOL
EQUIP.
DN 3 RISERS @ 7"
EACH TO -1'-9"
DN 3 RISERS @ 7"
EACH TO -1'-9"
DN 3 RISERS @ 7"
EACH TO -1'-9"
JOHNSON ROAD
(VARIABLE WIDTH RIGHT-OF-WAY)RANDOL MILL AVENUE(VARIABLE WIDTH RIGHT-OF-WAY)(LOT INFORMATION)
JOHN J. FRESHOUR SURVEY
ABSTRACT NUMBER 521
TRACT 8B
TARRANT COUNTY
(OWNER)
SOHAIL MADHANI
DOC. NO. D221023335
O.P.R.T.C.T.
OWNER = JOHNSON PLACE HMO ASSOC INC.
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 1, BLOCK 5, OPEN SPACE
JOHNSON PLACE ESTATES
CABINET A, SLIDE 12309
P.R.T.C.T.
OWNER = SOBHA REDDY
SIVAPRASAD REDDY
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 4 BLOCK 5
JOHNSON PLACE ESTATES
CABINET A, SLIDE 12309
P.R.T.C.T.
OWNER = JOANNA HOOKSTRATTEN
ZONING = AG
L.U.D. = LOW DENSITY RESIDENTIAL
DOCUMENT NO. D199278336
O.P.R.T.C.T.
OWNER = ROGER ALDINGER
ZONING = SF-1A
L.U.D. = LOW DESNSITY RESIDENTIAL
DRAKE ESTATES
LOT 3 AND 4A
VOL. 124, PG. 68
P.R.T.C.T.
OWNER = PAULUS TANDANG
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 1, BLOCK 8
MYERS MEADOW ADDITION
OWNER = BENJAMIN NG
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 2, BLOCK 8
MYERS MEADOW ADDITION
OWNER = ROBERT AND MAI WILLIAMS
FAMILY TRUST
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 3, BLOCK 8
MYERS MEADOW ADDITION
OWNER = MILLENNIUM PROPERTY
ACQUISITIONS SERIES LLC
ZONING = RPUD
L.U.D. = MEDIUM DENSITY RESIDENTIAL
LOT 4, BLOCK 8
MYERS MEADOW ADDITION
RESIDENTIAL
DRIVEWAY,
GRAVEL
RESIDENTIAL
DRIVEWAY,
CONCRETE
RESIDENTIAL
DRIVEWAY,
CONCRETE673'672'671'670'669'668'667'666'664'665'663'W
W
T
T
TC
C
L
L
L
F.H.
W
SCALE: 1" = 20'
1 CONCEPT PLAN
0 10'20'40'
PROJECT LOCATION
LINE LEGEND
PROPERTY LINE
SETBACK LINE
EASEMENT LINE
7'-6" WROUGHT IRON FENCE
NOTE: CIVIL GRADING & DRAINAGE NOT PART OF, TO BE
COMPLETED BY LICENSED CIVIL ENGINEER
CASE NUMBER: ZA22-0059
LOCATION MAP
(NOT TO SCALE)
OWNER INFORMATION
SOHAIL MADHANI
2401 SALMON RUN LANE
EULESS TX 76039
SITE DATA SUMMARY
EXISTING ZONING
PROPOSED ZONING
LAND USE DESIGNATION
GROSS ACREAGE
NET ACREAGE
PERCENTAGE OF SITE COVERAGE
PROPOSED BUILDING AREA (FOOT PRINT)
NUMBER OF STORIES
MAXIMUM BUILDING HEIGHT
66,727 SQ. FT.
65,179 SQ. FT.
LOW DENSITY RESIDENTIAL
SF-1A
AG
11.9%
7,950 SQ. FT.
2 STORIES
34'-115/8" TO MIDPOINT OF
HIGHEST PITCHED ROOF
40'-10" TO HIGHEST RIDGE
668669670671672673663664665666667669669
10003 TECHNOLOGY BLVD. WEST
DALLAS, TX 75220
972-620-8204
REGISTRATION NO: F-1629
0
SCALE: 1" =
20 20 40
20'
R
Know what's below.
Call before you dig.
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE,
OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER
UTILITIES.
N
700
698
STRAND
1
10003 TECHNOLOGY BLVD WEST | DALLAS TEXAS 75220 | 972 620 8204 | STRANDAE.COM
December 20, 2022
Keith Martin
Landscape Administrator
City of Southlake
1400 Main Street, Suite 460
Southlake, TX 76092
RE: Tree Preservation Plan – 2260 Johnson Road; Case No.: ZA22-0059
This memo is an acknowledgement that our current design is not in compliance with the City of Southlake Ordinance
585-E, Sec.7.2.a and Table 2.0 – Existing Tree Cover Preservation Requirements. We respectfully ask for a
variance from the existing code.
Ordinance 585-E: Sec.7.2.a
Table 2.0 – Existing Tree Cover Preservation Requirements. Minimum percentage of the existing tree cover to be
preserved = 70%
Variance Proposal:
Current existing tree cover constitutes for 4.9% of the lot coverage. Proposed development at 2260 Johnson Road
for a Low-Density Residential use would require a removal of 3 out of 8 existing trees from within the property. Such
action would result in the preserving 60.4% of the existing tree cover. We are asking to have the current proposed
tree preservation to be accepted.
We truly appreciate the consideration for this variance and understand that environmental sustainability and
stewardship and protecting the remaining natural resources in the city to maintain and enhance the quality of life of
the residents and businesses is a high priority for the City of Southlake. Please feel free to contact me if you have
any questions.
Respectfully,
Carlos Casas, PE
Senior Project Manager
Civil Engineering Department