Loading...
ZA22-0059-ZCP PUBLIC HEARING NOTICE ZA22-0059 • Zoning Change and Concept Plan on property described as Tract 8B, John J. Freshour Survey Abstract No. 521, located at 2260 Johnson Road, Southlake, Tarrant County, Texas. Current Zoning: “AG” Agricultural District. Proposed Zoning: “SF-1A” Single Family Residential District. • Current Zoning: “AG” Agricultural District • Requested Zoning: “SF-1A” Single Family Residential District • Purpose: The purpose of this request is to seek approval of a zoning change to “SF-1A” Single Family Residential District and a concept plan for the 1.5-acre property for one single family residence. Dear Property Owner: Your property has been identified as being within 300 feet of the above referenced Zoning Change application. A public hearing will be held by the City of Southlake Planning and Zoning Commission on January 5, 2023 at 6:30 pm in the Town Hall Council Chambers at 1400 Main Street, Southlake, Texas. Please note that this letter and its attachments constitute written notice about the proposed Zoning Change. If you wish to register your opposition or support to this action, you may complete and send the Notification Response Form to the Planning & Development Services Department. You are encouraged to follow the request through final action because changes are often made during the review process. Please contact the Planning and Development Services Department if you have any questions: Project Contact: Reagan Rothenberger, Phone: (817) 748-8602 | Dept. Phone: (817) 748-8621 CITY OF SOUTHLAKE PLANNING & DEVELOPMENT SERVICES 1400 Main St.; Suite 310 Southlake, TX 76092 Phone: (817) 748-8621 Fax: (817) 748-8077 www.cityofsouthlake.com Planning and Zoning Commission Thursday, January 5, 2023 6:30 PM Town Hall Council Chambers 1400 Main Street Southlake, Texas Notification Response Form ZA22-0059– Zoning Change and Concept Plan for 2260 Johnson Road Meeting Date: January 5, 2023 at 6:30 PM PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY BEFORE THE START OF THE SCHEDULED PUBLIC HEARING. Being the owner(s) of the property so noted above, are hereby in favor of opposed to undecided about (circle or underline one) the proposed Preliminary Plat referenced above. Space for comments regarding your position: ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________________________________________ Signature: _______________________________________ Date: ______ Additional Signature: _______________________________ Date: ______ Printed Name(s): _____________________________________________ Must be property owner(s) whose name(s) are printed at top. Otherwise contact the Planning Department. One form per property. Phone Number (optional): ______________________________________ Direct questions and mail responses to: City of Southlake Planning & Development Services Notification Response 1400 Main St; Ste 310 Southlake, TX 76092 Phone: (817) 748-8621 Fax: (817) 748-8077 11/28/22, 3:52 PM F2C5F914-56C0-4FC8-87A2-ED68E5E5592D.jpeg https://mail.google.com/mail/u/0/#inbox?projector=1 1/1 Dates: Project Start Date: Project Information: CAD File Name: Designed By: This drawing checked by: Sheet Number:The Madhani ResidenceProject No:2037Christopher D. Hough Madhani V4CD DV.pln A1-01Project Status:Construction Documents2260 JOHNSON ROADSOUTHLAKE, TX, 76092596 North KimballSuite 100Southlake, Texas 76092817 ¥ 988 ¥ 9680 (OFFICE)www.HeritageDesignStudio.comoffice@HeritageDesignStudio.comJune 16th, 2021 Date of Issue: Monday, December 19, 2022Design Version No: Version 4File last saved on: 12/19/22, 11:11 AM /Users/shawn/Heritage Office Dropbox/Heritage Data/ PROJECTS/FINISHED PROJECTS/2137 Madhani/ ArchiCAD/Madhani V4CD DV.pln File Path: Project Version Number: Version 4 Sheet Name:SITE PLAN FOR CONSTRUCTION 12-19-22 S 8 5 ° 5 0 ' 5 9 " W 3 5 .3 5 ' S 88° 49' 52" W 120.83' N 89° 36' 41" W 23.81'S 44° 24' 31" W 12.48'N 0° 21' 30" W356.89'N 89° 23' 2" E188.09'S 0° 27' 30" E345.14'15'-71/2"3'-111/2"11'-8"31'-21/2"26'-81/2"31'-21/2" 48'-0"48'-0" 20'-0" 20'-0"124'-75/8"23'-13/8"103'-11/4"50'-25/8" 45'-7/8"46'-87/8"40'-0"101'-103/8"35'-0"76'-33/4" 65'-0"8'-81/4"63'-0"5'-0"14'-0" (TYP.)4'-0"35'-0"28'-0"14'-0"28'-0" 20'-0"20'-0"20'-0" 91'-93/4"167'-13/4" 6'-0"32'-41/8"Rad. = 25'-0"Rad. = 25'-0" Rad. = 3'-0"Rad. = 3'-0" Rad. = 5'-0"Rad. = 5'-0" 40' FRONT YARD SETBACK 20' SIDE YARD SETBACK 50' FRONT/SIDE YARD SETBACK 40' REAR YARD SETBACK EMBEDDED LED DRIVEWAY UP LIGHTS @ 10'-0" O.C. 24"x24" 8' COLUMN W/ STUCCO EXTERIOR 7'-6" WROUGHT IRON FENCE PER SECTION 39.5.c.4 SLIDING MOTOR COURT GATE - TO BE SELECTED BY OWNER TREES TO BE REMOVED TREES TO BE REMOVED CONCRETE MOTOR COURT W/ BRICK BORDER CONCRETE DRIVE & MOTOR COURT EXISTING DRAIN EXISTING DRAIN EXISTING DRAIN TREE TO BE PRESERVED TREE TO BE REMOVED STORM ROOM EXISTING CONCRETE SIDEWALK (VARIABLE WIDTH) PROPOSED NEW CONCRETE SIDEWALK TREE TO BE PRESERVED EXISTING CONCRETE SIDEWALK FIRE HYDRANT 7'-6" WROUGHT IRON FENCE PER SECTION 39.5.c.4 7'-6" WROUGHT IRON FENCE PER SECTION 39.5.c.4 EXISTING WATER METER TO BE RELOCATED OUTSIDE OF PROPOSED DRIVEWAY JOHNSON ROAD RANDOL MILL AVENUEPER SF-1A ZONING 66,727 SQ. FT. (1.53 ACRES) 20% MAX LOT COVERAGE 40' FRONT SETBACK 20' SIDE SETBACK 40' REAR SETBACK *50' SETBACK ALONG RANDOL MILL EXISTING STORAGE BUILDING - TO BE REMOVED POOL - BY OTHER PROPOSED 2-STORY RESIDENCE COVERAGE SUMMARY LOT SQUARE FOOTAGE: 66,727 SQ. FT. RESIDENCE COVERAGE: 7,950 SQ. FT. % OF LOT COVERED: 11.9% FOUNTAIN F.F.E. +1'-9" A/C A/C A/C A/C POOL EQUIP. DN 3 RISERS @ 7" EACH TO -1'-9" DN 3 RISERS @ 7" EACH TO -1'-9" DN 3 RISERS @ 7" EACH TO -1'-9" JOHNSON ROAD (VARIABLE WIDTH RIGHT-OF-WAY) 70' RIGHT-OF-WAY DEDICATION EASEMENT RANDOL MILL AVENUE(VARIABLE WIDTH RIGHT-OF-WAY)70' RIGHT-OF-WAY DEDICATION EASEMENT (LOT INFORMATION) JOHN J. FRESHOUR SURVEY ABSTRACT NUMBER 521 TRACT 8B TARRANT COUNTY LOT 1, BLOCK A JOHNSON ADDITION (OWNER) SOHAIL MADHANI DOC. NO. D221023335 O.P.R.T.C.T. OWNER = JOHNSON PLACE HMO ASSOC INC. ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 1, BLOCK 5, OPEN SPACE JOHNSON PLACE ESTATES CABINET A, SLIDE 12309 P.R.T.C.T. OWNER = SOBHA REDDY SIVAPRASAD REDDY ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 4 BLOCK 5 JOHNSON PLACE ESTATES CABINET A, SLIDE 12309 P.R.T.C.T. OWNER = JOANNA HOOKSTRATTEN ZONING = AG L.U.D. = LOW DENSITY RESIDENTIAL DOCUMENT NO. D199278336 O.P.R.T.C.T. OWNER = ROGER ALDINGER ZONING = SF-1A L.U.D. = LOW DESNSITY RESIDENTIAL DRAKE ESTATES LOT 3 AND 4A VOL. 124, PG. 68 P.R.T.C.T. OWNER = PAULUS TANDANG ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 1, BLOCK 8 MYERS MEADOW ADDITION OWNER = BENJAMIN NG ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 2, BLOCK 8 MYERS MEADOW ADDITION OWNER = ROBERT AND MAI WILLIAMS FAMILY TRUST ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 3, BLOCK 8 MYERS MEADOW ADDITION OWNER = MILLENNIUM PROPERTY ACQUISITIONS SERIES LLC ZONING = RPUD L.U.D. = MEDIUM DENSITY RESIDENTIAL LOT 4, BLOCK 8 MYERS MEADOW ADDITION RESIDENTIAL DRIVEWAY, GRAVEL RESIDENTIAL DRIVEWAY, CONCRETE RESIDENTIAL DRIVEWAY, CONCRETE673'672'671'670'669'668'667'666'664'665'663'W W T T TC C L L L F.H. SCALE: 1" = 20' 1 CONCEPT PLAN 0 10'20'40' PROJECT LOCATION LINE LEGEND PROPERTY LINE SETBACK LINE EASEMENT LINE 7'-6" WROUGHT IRON FENCE NOTE: CIVIL GRADING & DRAINAGE NOT PART OF, TO BE COMPLETED BY LICENSED CIVIL ENGINEER CASE NUMBER: ZA22-0059 LOCATION MAP (NOT TO SCALE) OWNER INFORMATION SOHAIL MADHANI 2401 SALMON RUN LANE EULESS TX 76039 SITE DATA SUMMARY EXISTING ZONING PROPOSED ZONING LAND USE DESIGNATION GROSS ACREAGE NET ACREAGE PERCENTAGE OF SITE COVERAGE PROPOSED BUILDING AREA (FOOT PRINT) NUMBER OF STORIES MAXIMUM BUILDING HEIGHT 66,727 SQ. FT. 65,179 SQ. FT. LOW DENSITY RESIDENTIAL SF-1A AG 11.9% 7,950 SQ. FT. 2 STORIES 34'-115/8" TO MIDPOINT OF HIGHEST PITCHED ROOF 40'-10" TO HIGHEST RIDGE