ZA22-0008-DSP
PUBLIC HEARING NOTICE
ZA22-0008
• Development Plan and Site Plan for Verizon Expansion on property described
as Tracts 1C1A, 1C1B, 1C2 and 1F, James B. Martin Survey, Abstract No. 1134,
City of Southlake, Tarrant County, Texas, and located at 747 W. S.H. 114,
Southlake, Texas. SPIN Neighborhood #1.
• Current Zoning: “NR-PUD”, Non-Residential Planned Unit Development
District.
• The purpose of this request is to seek approval of a Development Plan and
Site Plan for a Verizon data center on approximately 25.15 acres .
Dear Property Owner:
Your property has been identified as being within 300 feet of the above referenced Site Plan
application.
If you wish to register your opposition or support to this case, you may complete the attached
Notification Response Form and either mail to the Planning & Development Services Department
(address listed at the top of notice), email a copy to the project case planner (e-mail listed at the
bottom of the notice) or fax a copy to the department (fax number listed at the top of the notice).
You are encouraged to follow the requested action through final approval because changes are
often made during the review process.
Please contact the Planning and Development Services Department if you have any questions:
Project Contact: Dennis Killough, E-mail: dkillough@ci.southlake.tx.us Phone: (817) 748-8072
Dept. Phone: (817) 748-8621
CITY OF SOUTHLAKE
PLANNING & DEVELOPMENT SERVICES
1400 Main St.; Suite 310
Southlake, TX 76092
Phone: (817)748-8621
Fax: (817)748-8077
www.cityofsouthlake.com
Planning and Zoning Commission
Thursday, February 17, 2022
6:30 PM
Town Hall Council Chambers
1400 Main Street
Southlake, Texas
Notification Response Form
ZA22-0008:
Development/Site Plan for Verizon Expansion
Meeting Date: February 17, 2022 at 6:30 PM
Fill out:
Owner: _____________________________
Address: ____________________________
City, State, Zip Code: __________________
PLEASE PROVIDE COMPLETED FORMS VIA MAIL, FAX OR HAND DELIVERY
BEFORE THE START OF THE SCHEDULED PUBLIC HEARING.
Being the owner(s) of the property so noted above, are hereby
in favor of opposed to undecided about
(circle or underline one)
the proposed Development/Site Plan referenced above.
Space for comments regarding your position:
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
Signature: _______________________________________ Date: ______
Additional Signature: _______________________________ Date: ______
Printed Name(s): _____________________________________________
Must be property owner(s). Otherwise contact the Planning Department. One form per property.
Phone Number (optional): ______________________________________
Direct questions and mail responses to:
City of Southlake
Planning & Development Services
Notification Response
1400 Main St; Ste 310
Southlake, TX 76092
Phone: (817) 748-8621
Fax: (817) 748-8077
STATE HWY
1
1
4 TYLERSTW
E
L
F
O
R
D L
N
BROADGATE LNS
T H
W
Y 11
4
IDLEWILD CTSTOCKTON D RCOPPERFIELDST
O R C H A R D H I LLDR
STOCKTONSHADYO
A
K
S
D
R
N
W
HIT
E C
H
A
P
E
L B
L
V
D
W DOVE RD
SWEET STMARSHALLRD
L
I
NDENL
NM
A
R
S
H
A
LL
R
DROUNDHOLLOWLN
LILLY
MAGNOL IA
W DOVE RD WK
I
R
K
WO
O
D
B
L
V
D
W KIRKWOOD BLVDTDAMERITRADE LN
AMELIAISLANDWKI
RK
WO
O
D
B
L
V
DM U R P H Y D R
METAIRI
EL
N
SAVANNAH TRL
CHARLE STON DR PATHJAM ESTOWN LN
975 935 865 825
940
2
82
5
2
73
5
28012814 455445443439
415413411409407405
4032
8
0
22810281 240040228084
2
8
4162950
504
508
5 1 6
5 2 0
5 2 4
505
509
5 1 7
52152653 0540570
525
529
5
3
3
537
5 6 9
5 7 3
5 7 7
58128012
2
9
9 1211251291331373005
30013004
409405403401309
305
301
2 1 7
213
209
205
201200
204
208
212
3003044 0 0404408412416420421417413409405403400402
4 0 4
4 0 6
410414418422405409413417
216685
600
2
2
0
1
422
701
105 125
4 0 6 417
4
1
928072
8
0
5
2
8
0
3
4
2
0
422
40445445645828062
8
0
4452 42644644845
04534514494474 4 1
2
8
1
3
281128092
8
0
7
2805
280
3
1 5 023012300
2304
2308
2305
2309401280428022815500437
4
3
1
4
23
4
2
1
427
425
4
3
5
4
3
3
429
440
541
442107
512 513
2520116106
50023552816 4254
2
0
4
2
12800 4 1 6
2798
2
8
1
9
281
8
1
0
5
01
0
5
1
747
850974
901905 813 809 8 0 5 8 0 1
700701705709
704708701705
230023082304231224013010
8 0 0 24053000
100
2217
2221
2225
2229
2220
2224
2228104108112116200204208212216
217 213 209 205
224228232225229233982
704 7
0
0240924132501804800808
809 805 801
808 804812900816904
905 817 813
812816
901
900904
904 900 820
905 901 817 813 809 805 801
812816 808 804 800
25092505Vicinity Map
®0 920 1,840460Feet
ZA22-0008Development Plan/Site Plan for Verizon Expansion
747 W. S.H. 114
SPINESLOPEFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL
FL
FL FL FL FL FLFLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FLFLFLFLFLFLFLFL FL FL FL FL
FL
FL
FL
FL
FLFLFLFLFLFLFLFLFLFLFLFLFLFLFL15' SANITARY SEWER
EASEMENT
JAMES B. MARTIN SURVEY
ABSTRACT NO. 1134
KIRKWOOD BOULEVARDSTATE HIGHWAY NO. 114L=317.44'
R=4843.00'
Δ=3°45'20"
CB=N26° 18' 30"W
CL=317.39
L=695.83'
R=4831.00'
Δ=8°15'09"
CB=N32° 18' 42"W
CL=695.23
S61°48'53"W
12.00
N67°59'18"E
12.00
L=32.63'
R=4831.00'
Δ=0°23'13"
CB=N21° 49' 06"WN24°20'45"W 807.00'S65°38'13"W
1
0
2
8
.
9
0
'S34°06'40"E 470.25'L=204.44'
R=4843.00'
Δ=2°25'07"
CB=N23° 13' 16"W
CL=204.42
L=1054.91'
R=1778.00'
Δ=33°59'40"
CB=S17° 06' 50"W
CL=1039.51
L=303.19'
R=2101.00'
Δ=8°16'06"
CB=S29° 58' 37"E
CL=302.93S25°50'34"E 200.00'L=206.33'
R=1424.00'
Δ=8°18'07"
CB=S29° 59' 37"W
CL=206.15
L=695.83'
R=4831.00'
Δ=8°15'09"
CB=N32° 18' 42"W
CL=695.23
100-YR FULLY DEVELOPED FLOODPLAIN PER
KIRKWOOD BRANCH WATERSHED STUDY BY
HALFF ASSOCIATES DATED FEBRUARY 2021.
EXISTING
POND
R7
2
.0'R36.0'
R 2 4.0'R9.0'
R30.
0
'R30.0 'R 26.0'R 2 6.0'R55.0 'R25.0'R 6 1.0'R 2 5 .0'R 24.0
'
R
3
6.0'
R
3
6
.
0
'
R36.0'R36.0 'R24.0 'R30.0'
R30.0'R30.0 'R3
0.0'
R5.0'
(TYP.)R36.0 'R24.0'
R 30.0'R30.0'72.0'8.4'126.0'55.3'90.0'8.4'54.0'7.0'
81.0'
7.0'
72.0'
POD 2
DATA CENTER
36,500 SF
1-STORY
BUILDING HEIGHT: 24 FT
POD 1
DATA CENTER
36,500 S.F.
1-STORY
BUILDING HEIGHT: 24 FT
OPERATION
11,200 SF
1-STORY
BUILDING HEIGHT: 24 FT
DALLAS MTA, L.P.
ZONED = NR-PUD
L.U.D. = MIXED USE
PROPOSED
RETAINING WALL
HEIGHT ±9.5 FT
PROPOSED
RETAINING WALL
HEIGHT ±7 FT
PROPOSED
RETAINING WALL
HEIGHT ±3.5 FT
PROPOSED
RETAINING WALL
HEIGHT ±7 FT
x
xxx
x
x
x x
x
x x x x
x
x x x
x
x
x
x
x x x x
x
30.4'356.1'
T
O
EX. FI
R
E
H
Y
D
R
A
N
T
EQUIPMENT YARD
PROPOSED
RETAINING WALL
HEIGHT ±13 FT
MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT MECHANICALUNIT10987612345MECHANICALUNIT
MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10 9 8 7 6 12345MECHANICALUNIT
KIRKWOOD HOLLOW ADD.
ZONED = RPUD
L.U.D.= MEDIUM DENSITY
RESIDENTIAL
10' WATER
EASEMENT
10' WATER
EASEMENT
20' BUFFERYARD
TYPE C
20' BUFFERYARD
TYPE D
SPINE 17,000 SF
x
x
x x x x
x
x
x
x
36.0'24.0'48.0'36.0'30.0'133.3'269.4'
102.7'36.0'36.0'36.0'26.2'36.0'
18.0'
203.8'25.8'294.8'36.0'67.5'
121.5'
26.0'36.0'24.0'36.0'36.2'9.0'TYP.9.0'
TYP.
30.4'18.0'143.3'88.8'75.9'85.1'25.1'48.0'41.5'144.2'268.8'
72.0'
19.3'
94.3'
x
x x
x
xxxx
x
xxxx
x
x
x
POD 5
DATA CENTER
36,500 S.F.
1-STORY
BUILDING HEIGHT: 24 FT
POD 4
DATA CENTER
36,500 S.F.
1-STORY
BUILDING HEIGHT: 24 FT
POD 3
DATA CENTER
36,500 S.F.
1-STORY
BUILDING HEIGHT: 24 FT 68.2'24.0'30.0'66.0'46.3'143.5'269.4'30.4'143.5'69.0'24.0'30.6'144.2'84.1'143.5'143.5'143.5'68.2'144.2'35.4'101.3'PROPOSED DRIVEWAY LOCATION
PER TXDOT SH 114 FRONTAGE
ROAD PLANS DATED 4-17-2020
PROPOSED
TURN LANE
PROPOSED
SWITCHGEAR
LOCATION
PROPOSED
ACCESS GATE
PROPOSED
ACCESS GATE
8' TALL ALUMINUM
ORNAMENTAL
PERIMETER FENCE
PROPOSED
ACCESS GATE
PROPOSED
DUMPSTER
5' SIDEWALK
5' SIDEWALK
PROPOSED 10'
METAL FENCE
PROPOSED 10'
METAL FENCE
8' TALL ALUMINUM
ORNAMENTAL
PERIMETER FENCE
8' TALL ALUMINUM
ORNAMENTAL
PERIMETER FENCE
8' TALL ALUMINUM
ORNAMENTAL
PERIMETER FENCE
EXISTING
CONCRETE
PAVEMENT
EXISTING
CONCRETE
PAVEMENT
CONNECT TO EX.
SS LINE
PROPOSED 10'
METAL FENCE
PROPOSED 10'
METAL FENCE
PROPOSED 10'
METAL FENCE
PROPOSED 10'
METAL FENCE
PROPOSED BIKE
RACK PAD
0 60'120'
GRAPHIC SCALE - 1"=60'
1
SITE PLAN
N
ENGINEER
HALFF ASSOCIATES, INC.
1201 N BOWSER RD
RICHARDSON, TX 75081
CONTACT: KAYLIE FLYNN, PE
(214) 937-3923
KFLYNN@HALFF.COM
OWNER / DEVELOPER
VERIZON WIRELESS TEXAS LLC
P.O. BOX 2549
ADDISON, TX 75001
DALLAS MTA LP
P.O. BOX 2549
ADDISON, TX 75001-2549
OVERALL SITE PLAN
SOUTHLAKE NEW BUILD
LOT 1R, BLOCK 1 SOLANA ADDITION
24.35 ACRES
SITUATED IN THE
J.B. MARTIN SURVEY ABSTRACT NO. 1134
CITY OF SOUTHLAKE, TARRANT COUNTY, TEXAS
JANUARY, 2022
LEGEND
6" THICK 3500 PSI CONCRETE PAVEMENT
6" THICK 3500 PSI CONCRETE PAVEMENT
8" THICK 3500 PSI CONCRETE PAVEMENT
BUILDING ENTRANCE/EXIT
PROPOSED LIGHT
x
PARKING ANALYSIS CHART
TOTAL PARKING REQUIRED 97
TOTAL PARKING PROVIDED 131
HANDICAP PARKING REQUIRED 4
HANDICAP PARKING PROVIDED 7
SITE DATA SUMMARY CHART
PHASE I FUTURE PHASES TOTAL
ANTICIPATED DEVELOPMENT SCHEDULE 2022 TBD
ZONING "NR-P.U.D.
LAND USE DESIGNATION MIXED USES
GROSS/NET ACREAGE SF/AC 1,060,860 SF (24.35 AC)
NUMBER OF PROPOSED LOTS 1
SITE COVERAGE (%)8.86%11.00%19.86%
AREA OF IMPERVIOUS COVERAGE SF (%)301,032 SF SF (28.38%)166,859 SF (15.73%)467,891 SF (44.10%)
AREA OF OPEN SPACE SF/(%)759,828 SF (71.62%)710,041 SF (55.90%)710,041 SF (55.90%)
TOTAL BUILDING/FLOOR AREA (SF)94,000 SF 116,700 SF 210,700 SF
BUILDING USE 94,000 SF: DATA CENTER 116,700 SF: DATA CENTER 210,700 SF: DATA CENTER
NUMBER OF STORIES 1 1
BUILDING HEIGHT(S)24 FT 24 FT
SUMMARY CHART- BUFFER YARD
LOCATION/DIRECTION REQUIRED/
PROVIDED LENGTH BUFFERYARD
WIDTH/TYPE
CANOPY
TREES
ACCENT
TREES SHRUBS
NORTHEAST REQUIRED 1179.77 C/ 10 FT 29 38 115
PROVIDED 0 5 115
SOUTHWEST REQUIRED 1025.27 D/ 10 FT 35 44 158
PROVIDED 0 44 158
EXISTING TREE CREDIT SUMMARY
42 TREES @ 6"-12" DBH
16 TREES @ GREATER THAN 12" DBH
* NOTE ANY CREDITS USED IN CALCULATIONS
A. REQUIREMENTS REDUCED BY 20% DUE TO DOUBLING OF BUFFER DEPTH
B. ALL CANOPY TREES REQUIRED AND SOME OF THE ACCENT TREES REQUIRED SATISFIED BY EXISTING TREE CREDITS
SUMMARY CHART
LANDSCAPE
AREA
% OF
AREA IN
FRONT
OR SIDE
CANOPY
TREES
ACCENT
TREES SHRUBS
GROUND
COVER
(SF)
SEASONAL
COLOR
(SF)
REQUIRED 19188
75%
39 77 480 2,879 384
PROVIDED 203463 75%39 IN
PROGRESS 483 4,027 409
1/24/2022Sheet Number
Sheet Title
Scale:AS NOTED
BDLChecked By:
Drawn By:KEF
42036
Issued:
Project No.:RevisionNo.DateDescriptionSOUTHLAKE, TEXASSOUTHLAKE NEW BUILDI:\42000s\42036\002\CADD\SheetsRCH\C0.01-SP OVERALL-42036.dwgJANUARY, 2022 1201 NORTH BOWSER ROADRICHARDSON, TEXAS 75081-2275TEL (214) 346-6200FAX (214) 739-0095PRELIMINARY
KAYLIE FLYNN 135900
P.E. NO.
1/24/22DATE
THESE DOCUMENTS ARE FOR INTERIM
REVIEW AND NOT INTENDED FOR
REGULATORY APPROVAL, PERMIT, BIDDING
OR CONSTRUCTION PURPOSES. THEY
WERE PREPARED BY OR UNDER THE
SUPERVISION OF:
NAME
FOR INTERIM REVIEW ONLY
TBPE FIRM #F-312VERIZON
STATE HIGHWAY NO. 114D
O
V
E
R
O
A
D
JAMES B. MARTIN SURVEY
ABSTRACT NO. 1134
KIRKWOOD BOULEVARDSTATE HIGHWAY NO. 114SPINESLOPE TRI-COUNTY
ELECTRIC
EQUIPMENTFLFLFLFLFLFLFLFLFL
FL FL FL FLFL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL
FL
FL
FLFLFLFLFLFLFLFLFLSTATE HIGHWAY NO. 114D
O
V
E
R
O
A
D
JAMES B. MARTIN SURVEY
ABSTRACT NO. 1134
KIRKWOOD BOULEVARDSTATE HIGHWAY NO. 114EXISTING
POND
EX. 10' SIDEWALK
EX. 10' SIDEWALK
EX. 6' SIDEWALK
EX. 6' SIDEWALK
EX. 6' SIDEWALK
EX. 6' SIDEWALK
5' SIDEWALK UNDER
CONSTRUCTION
5' SIDEWALK UNDER
CONSTRUCTION
5' SIDEWALK UNDER
CONSTRUCTION
5' SIDEWALK UNDER
CONSTRUCTIONMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNIT
3
PEDESTRIAN ACCESS
PLAN
00 100'200'
GRAPHIC SCALE - 1"=100'
N
1/24/2022Sheet Number
Sheet Title
Scale:AS NOTED
BDLChecked By:
Drawn By:KEF
42036
Issued:
Project No.:RevisionNo.DateDescriptionSOUTHLAKE, TEXASSOUTHLAKE NEW BUILDI:\42000s\42036\002\CADD\SheetsRCH\EXH-PEDESTRIAN ACCESS OVERALL-42036.dwgJANUARY, 2022 1201 NORTH BOWSER ROADRICHARDSON, TEXAS 75081-2275TEL (214) 346-6200FAX (214) 739-0095PRELIMINARY
KAYLIE FLYNN 135900
P.E. NO.
1/24/22DATE
THESE DOCUMENTS ARE FOR INTERIM
REVIEW AND NOT INTENDED FOR
REGULATORY APPROVAL, PERMIT, BIDDING
OR CONSTRUCTION PURPOSES. THEY
WERE PREPARED BY OR UNDER THE
SUPERVISION OF:
NAME
FOR INTERIM REVIEW ONLY
TBPE FIRM #F-312VERIZON
JAMES B. MARTIN SURVEY
ABSTRACT NO. 1134
KIRKWOOD BOULEVARDSTATE HIGHWAY NO. 114L=317.44'
R=4843.00'
Δ=3°45'20"
CB=N26° 18' 30"W
CL=317.39
L=695.83'
R=4831.00'
Δ=8°15'09"
CB=N32° 18' 42"W
CL=695.23
S61°48'53"W
12.00
N67°59'18"E
12.00
L=32.63'
R=4831.00'
Δ=0°23'13"
CB=N21° 49' 06"WN24°20'45"W 807.00'S65°38'13"W
1
0
2
8
.
9
0
'S34°06'40"E 470.25'L=204.44'
R=4843.00'
Δ=2°25'07"
CB=N23° 13' 16"W
CL=204.42
L=1054.91'
R=1778.00'
Δ=33°59'40"
CB=S17° 06' 50"W
CL=1039.51
L=303.19'
R=2101.00'
Δ=8°16'06"
CB=S29° 58' 37"E
CL=302.93S25°50'34"E 200.00'L=206.33'
R=1424.00'
Δ=8°18'07"
CB=S29° 59' 37"W
CL=206.15
L=695.83'
R=4831.00'
Δ=8°15'09"
CB=N32° 18' 42"W
CL=695.23
SPINESLOPEEV EV EV LEV LEV LEV LEV LEV LEV LEV
PROPOSED
ACCESS GATE
PROPOSED
ACCESS GATEMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNITMECHANICALUNIT10987612345MECHANICALUNIT 0 60'120'
GRAPHIC SCALE - 1"=60'
4
FENCING
CONCEPT PLAN
N
LEGEND
PROPOSED 8' TALL ALUMINUM ORNAMENTAL
PERIMETER FENCE
PROPOSED 10' METAL FENCE
1/24/2022Sheet Number
Sheet Title
Scale:AS NOTED
BDLChecked By:
Drawn By:KEF
42036
Issued:
Project No.:RevisionNo.DateDescriptionSOUTHLAKE, TEXASSOUTHLAKE NEW BUILDI:\42000s\42036\002\CADD\SheetsRCH\EXH-FENCE OVERALL-42036.dwgJANUARY, 2022 1201 NORTH BOWSER ROADRICHARDSON, TEXAS 75081-2275TEL (214) 346-6200FAX (214) 739-0095PRELIMINARY
KAYLIE FLYNN 135900
P.E. NO.
1/24/22DATE
THESE DOCUMENTS ARE FOR INTERIM
REVIEW AND NOT INTENDED FOR
REGULATORY APPROVAL, PERMIT, BIDDING
OR CONSTRUCTION PURPOSES. THEY
WERE PREPARED BY OR UNDER THE
SUPERVISION OF:
NAME
FOR INTERIM REVIEW ONLY
TBPE FIRM #F-312VERIZON
GLASS
TYPE 02
METAL
PANEL
BRICK TYPE 01BRICK TYPE 02
CONCRETE
REVEAL
METAL LOUVER SCREEN
BRICK TYPE 01ARCHITECTURAL
CONCRETE PANEL
GLASS
TYPE 01
ARCHITECTURAL
CONCRETE
METAL LOUVER SCREEN
BRICK TYPE 02BRICK TYPE 01
GLASS TYPE 01
ARCHITECTURAL
CONCRETE PANEL
BRICK TYPE 02
BRICK TYPE 01
METAL LOUVER SCREEN
I N T E R I M R E V I E W O N L Y
Architect:
Arch. Reg. No.:
permit, or construction purposes.
are not intended for regulatory approval,
are released for interim review only and
These documents are incomplete, and
Date:
1 2 3 4 5 6
E
D
C
B
A
654321
A
B
C
D
E
DRAWN BY:
CHECKED BY:
COPYRIGHT:
DESIGNED BY:
CAD DWG FILE:
PROJECT NO:
SHEET TITLE
SHEET NUMBER
RECORD SET (AS−BUILTS)
CONSTRUCTION DESIGN SUBMISSION
100% SUBMISSION − POD 1
60% SUBMISSION − POD 2 (LAB)
60% SUBMISSION − POD 1
30% SUBMISSION
PRELIMINARY SUBMISSION
NETWORK COMPLIANCE SUBMITTALS DATE
This drawing was prepared solely for the use of
Verizon Wireless and must only be used by Verizon
Wireless employees, contractors, and vendors while
performing the work shown on this drawing. Any
other use of this drawing is forbidden.
REV DESCRIPTION DATE
210005
HKS, INC.
DALLAS, TX 75201
350 N SAINT PAUL STREET #100
1201 NORTH BOWSER ROAD
RICHARDSON, TEXAS 75081-2275
TEL (214) 346-6200
FAX (214) 739-0095
04/21/2021
05/24/2021
09/30/2021
STAMP
DUTCH E. WICKES
TX 12195
12/23/2021
100% SUBMISSION − POD 12 (LAB)
11/24/2021
PROGRESS SET 12/14/2021
12/23/2021
BIM 360://24453.000_VerizonVzWDataCenter˘Southlake_2021/A_VZW−SL_2021.rvt1/6/2022 3:43:37 PMSOUTHLAKE NEW BUILD500 W DOVE ROADSOUTHLAKE, TX24453.000
HKS
HKS
HKS
EXTERIOR FINISH SCHEDULE
A210 CONCEPT
1/2" = 1'-0"01 OPERATION
1/2" = 1'-0"02 TYP EQUIPMENT YARD
1/2" = 1'-0"03 POD
1/2" = 1'-0"04 EQUIPMENT YARD TYP
MATERIALS MATRIX - EXTERIOR
IMAGE Mark Material: Description Manufacturer
Model
Information Comments URL reference
WALLS
ACT-01 Architectural Concrete