Loading...
Item 6B - Plans1 Site: 1201 E. State Highway 114 Suite #110 Grapevine, TX 76092 22-1193-R07 SITE # 20C0010 Date: 11.28.2022 Prepared for: SIR Brand Book 2 CRITICAL ISSUES Page OVERALL FINDINGS SUMMARY • TWO (2) WALL SIGNS ALLOWED PER TENANT • STANDARD CAPITAL GRILLE SIGN TYPES ALLOWED • NO ISSUSES W/ ILLUMINATION • ALLOWED 87.5 SF PER ELEVATION BASED ON CODE FORMULA • MULTI-TENANT CENTER SIGN EXISTS • ONLY TWO (2) SIGNS ALLOWED BUT FOUR (4) ARE PROPOSED • CURRENTLY PROPOSING OVER THE SF ON EAST ELEVATION • CODE ALLOWS ONE (1) PROJECTING SIGN IN ADDITION TO THE TWO (2) MAX WALL SIGNS • CODE ALLOWS SEPARATE MONUMENT SIGNS BUT LL UNLIKELY DUE TO EXISTING MULTI-TENANT SIGN • CITY DOES OFFER SIGN VARIANCE PROCESS. THESE ARE TYPICALLY SUPPORTED AS LONG AS IT’S NOT TOO EXCESSIVE. THE PROCESS IS MIN. 2-3 MONTHS AND REQUIRES BOTH VARIANCE BOARD AND CITY COUNCIL • MAIN VEHICULAR TRAFFIC OFF STATE HWY 114 AND NORTH ELEVATION WOULD OFFER DECENT VISIBILITY TO THESE TRAFFIC LANES ALTHOUGH THERE ARE ALSO TREES THAT BLOCK SOME ANGLES • WE RECOMMEND TRIMMING OR REMOVING TREE ON WEST SIDE ELEVATION THAT WILL PARTICULARLY BLOCK VISIBILITY OF WEST SIDE SIGN Overall Findings Summary / Critical Issues 3 Vicinity Map and S/C Plan View Page AERIAL VIEW SCALE: NTS2 VICINITY MAP SCALE: NTS1 SITE LOCATION 4 Site Plan Page SITE PLAN SCALE: NTS1 SQUARE FOOTAGE CHART SIGN “A” = 12.35 Sq. Ft. SIGN “B” = 82.39 Sq. Ft. EAST ELEVATION ALLOWED = 91 PROPOSED = 94.97 SIGN “C” = 77.29 Sq. Ft. WEST ELEVATION ALLOWED = 91 PROPOSED = 77.29 A B C E1 SIGN “D” = 46.72 Sq. Ft. NORTH ELEVATION ALLOWED = 50.63 PROPOSED = 46.72 D F G E2 9,306 SF 5 Elevations Page EAST ELEVATION RENDERING (MAIN ENTRY) SCALE: 3/32” = 1' - 0"1 FIELD OF VISIBILITY AQTY: ONE (1) SIGN AREA = 82.39 Sq. Ft. HALO ILLUMINATED CHANNEL LETTERS SCALE: 1/4” = 1' - 0"B 36” OAH36” OAH36” OAH ±20’ - 5” AFF±20’ - 5” AFF±20’ - 5” AFF12' - 4 1/2”12”-“P”8”“T”QTY: ONE (1) SIGN AREA = 12.35 Sq. Ft. FACE ILLUMINATED CHANNEL LETTERS SCALE: 3/8” = 1' - 0"A B E1 MAX SF ALLOWANCE = .7 PER 1 LF .7 X 130 = 91 SF ALLOWED SIGN CANNOT EXCEED 75% OF WIDTH 48.41 X .75 = 36.3’ MAX WIDTH 130’ - 0” OAL of Frontage 36’ - 2 1/2” OAL of Signage36’ - 2 1/2” OAL of Signage36’ - 2 1/2” OAL of Signage B A 12’ - 4 1/2” OAL of Signage12’ - 4 1/2” OAL of Signage12’ - 4 1/2” OAL of SignageEQEQEQ EQEQEQ ±11’ - 0” AFF±11’ - 0” AFF±11’ - 0” AFFEQEQEQ 21 1/4" “T” 36"36' - 2 1/2" OAL Sign E2 48’ - 5”48’ - 5”48’ - 5” 12’ - 4 1/2”12’ - 4 1/2”12’ - 4 1/2” 12” OAH12” OAH12” OAH 18’ - 8” OAL CANOPY18’ - 8” OAL CANOPY18’ - 8” OAL CANOPY25”25”25”EQEQEQ 6 Elevations Page WEST ELEVATION RENDERING SCALE: 3/32” = 1' - 0"1 QTY: ONE (1) SIGN AREA = 77.29 Sq. Ft. HALO ILLUMINATED CHANNEL LETTERS SCALE: 1/4” = 1' - 0"C19 3/4" “T” 30”31' - 0” OAL Sign 31’ - 0” OAL of Signage31’ - 0” OAL of Signage31’ - 0” OAL of Signage EQUALEQUALEQUAL C ±20’ - 7 1/2” AFF±20’ - 7 1/2” AFF±20’ - 7 1/2” AFF30” OAH30” OAH30” OAH FIELD OF VISIBILITY 125' - 0” OAL of Frontage MAX SF ALLOWANCE = .7 PER 1 LF .7 X 130 = 91 SF ALLOWED SIGN CANNOT EXCEED 75% OF WIDTH 46 X .75 = 34.5’ MAX WIDTH C EQUALEQUALEQUAL 46' - 0” 7 Elevations Page NORTH ELEVATION RENDERING SCALE: 3/32” = 1' - 0"1 QTY: ONE (1) SIGN AREA = 46.72 Sq. Ft. S/F CABINET W/ ROUTED-OUT PUSHED-THRU LETTERS SCALE: 1/2” = 1' - 0"D 9’ - 0” 9’ - 0” OAL of SignageOAL of Signage 9’ - 0” OAL of Signage D FIELD OF VISIBILITY 72' - 4” OAL of Frontage MAX SF ALLOWANCE = .7 PER 1 LF .7 X 72.33 = 50.63 SF ALLOWED D 4”4”4” 9' - 0”14”50”8”7 1/2”58” OAH SIGN9' - 8” OAL SIGN ±18’ - 7” AFF±18’ - 7” AFF±18’ - 7” AFF50” OAH50” OAH50” OAH ±17’ - 9” TO TOP OF AWNING±17’ - 9” TO TOP OF AWNING±17’ - 9” TO TOP OF AWNING4”4”4” 8 Details Page 12' - 4 1/2” SPECIFICATIONS • Faces: 1/2” white acrylic, shoulder cut • Returns: 3” deep, .063” aluminum painted Benjamin Moore Studio Finishes “Silver Metallic” Silver-20 • Backs: .063” aluminum • Mounted flush to existing canopy face • Interior painted w/ White light enhancement paint • Illumination: 176 GEMM2471-W1 LEDs • NOTE: Primary power supplied to location by GC Wall detail TBV Blocking to be provided by GC New letterset to utilize existing wiring and location of power supplies QTY: ONE (1) SET SIGN AREA = 12.35 Sq. Ft. INTERNALLY ILLUMINATED TRIMLESS CHANNEL LETTERS SCALE: 3/4” = 1' - 0"A END VIEW 3” NIGHT TIME VIEW12”-“P”8”“T”NOTE: ELECTRICAL PENETRATIONS MUST MATCH PREVIOUS SET 9 Details Page SPECIFICATIONS • Faces: .125” Aluminum painted black • Returns: .063” Aluminum painted black • Backs: 3/16” clear polycarbonate • Mounted to fascia w/ 1-1/2” standoffs painted black • Interior painted w/ White light enhancement paint • Illumination: 176 GEMM2471-W1 LEDs • NOTE: Primary power supplied to location by GC Wall detail TBV Blocking to be provided by GC QTY: ONE (1) SET SIGN AREA = 82.39 Sq. Ft. HALO ILLUMINATED CHANNEL LETTERS SCALE: 3/8” = 1' - 0"B NIGHT TIME VIEW 3” 1 1/2” 21 1/4" “T” 36"36' - 2 1/2" OAL Sign END VIEW 10 Details Page30” - “P”31' - 0” END VIEW 1 1/2" 3” SPECIFICATIONS • Faces: .125” Aluminum painted black • Returns: .063” Aluminum painted black • Backs: 3/16” clear polycarbonate • Mounted to fascia w/ 1-1/2” standoffs painted black • Interior painted w/ White light enhancement paint • Illumination: 176 GEMM2471-W1 LEDs • NOTE: Primary power supplied to location by GC Wall detail TBV Blocking to be provided by GC QTY: ONE (1) SET SIGN AREA = 77.50 Sq. Ft. HALO ILLUMINATED CHANNEL LETTERS SCALE: 3/8” = 1' - 0"C19¾”“T”NIGHT TIME VIEW 11Page 3" CHANNEL LETTER (LED Halo-Lit) SECTION DETAIL SCALE: 3" = 1' - 0"1 Metal studs 16” O.C. (typ) .063 aluminum returns Zinc plated, flathead countersunk screws Gyp Board (Interior) pop rivets .125” aluminum face Paint interior with light enhancement paint LED strip lighting, VHB mounted to back 3/16” clear polycarbonate back Secondary low voltage wiring Conduit bushing Liquid tight conduit LED enclosure, waterproof box with removable cover Cut-off switch LED (12v) power supply Leave a gap at the bottom of letters for water to escape ¼-20, threaded stud and rivunt. Hardware to use will depend on wall conditions, per survey to be done U.L. LABELS REQUIRED INSTALL IN ACCORDANCE W/ NATIONAL ELECTRIC CODES NOTE: All primary electrical to sign location to be provided by others. A dedicated circuit with NO shared neutrals and a ground returning to the panel is required for installation. This sign is intended to be installed in accordance with Article 600 or the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All power supplies to be Ground-Fault Interrupted (GFI) Signage to have a dedicated branch circuit, three (3) wires (Line, Neutral and Ground) Wire sizes to be a minimum of 12 Ga. THHN copper wire. Gauge of wire is determined by the length of run and amperage as per NED Article 300 Voltage should read no more than 3 volts between ground and neutral Conduit can not be used as ground path Power to sign to be done by a electrical contractor or licensed electrician Ground wire must be continuous and go from sign to panel board ground bus. ®ALL COMPONENTS TO BE APPROVED 1 Dedicated 20 Amp Circuit at 120 Volts (Ea) 1½" Aluminum clips Aluminum spacers Blocking (wood or metal) behind fascia to be provided by G.C. Primary electrical (120v) provided by G.C. with 10’-0” whips Details B C 12 Details Page SPECIFICATIONS • 3” deep s/f aluminum cabinet • Face and returns painted black (satin finish) • Letters are 3/4” white (1/2” proud) pushed-thru acrylic • Border/dots are 1/2” thick FCOs painted silver (color TBD) • Mounted to flush to fascia • Interior painted w/ White light enhancement paint • Illumination: 176 GEMM2471-W1 LEDs NOTE: Primary power supplied to location by GC Wall detail TBV Blocking to be provided by GC QTY: ONE (1) SET SIGN AREA = 46.72 Sq. Ft. S/F CABINET W/ ROUTED-OUT PUSHED-THRU LETTERS SCALE: 1/2” = 1' - 0"D NIGHT TIME VIEW END VIEW 3”9' - 0”14”50”8”7 1/2”58” OAH Sign4”4”9' - 6” OAL Sign 4”4” 13 Details Page QTY: TWO (2) SIGN AREA =.90 Sq. Ft. Ea NON ILLUMINATED ALUMINUM WALL PLAQUE SCALE:3/4” = 1' - 0"E2 SPECIFICATIONS • 5/16" ALUMINUM BRUSHED W/ GLOSS CLEAR COAT • BEVEL: 1/4" X 3/4" DEEP OVERALL FROM FACE TO WALL • COPY: GLOSS BLACK - RECESSED • MOUNTING: OPTION 1: TO GRANITE OR METAL USED DOUBLE SIDED VHB TAPE OPTION 2: TO POROUS SURFACE USE 1/8" STUDS W/ EXTERIOR SILICONE E1 16"8 1/8"3/4"3/4" END VIEW OPTION 1 END VIEW OPTION 2 14 Tenant Panel Page ± 30” F MULTI-TENANT MONUMENT SIGN QTY: TWO (2) TENANT PANELS ON D/F MULTI-TENANT MONUMENT SCALE: 1” = 1' - 0"F SPECIFICATIONS • Use existing faces • 1st surface black vinyl • Exact panel location TBV ± 7’ - 0”± 1’ - 6”MONUMENT SIGN LOCATION F 15 MONUMENT SIGN LOCATION MULTI-TENANT MONUMENT SIGN QTY: TWO (2) TENANT PANELS ON D/F MULTI-TENANT MONUMENT SCALE: 1” = 1' - 0"G SPECIFICATIONS • New aluminum faces paint to match existing (TBV) • 1st surface white vinyl • Exact panel location TBV ± 6’ - 0”± 1’ - 0”G G