Loading...
SB Item 5 - PlansLEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" 123456 T.O.P. 182' -6" PENTHOUSE 192' -0" 50' - 0"4' - 0"30' - 0"2' - 0"50' - 0"4' - 0"2' - 0"30' - 0" ARCHITECTURAL LIGHTING AT BASE OF COLUMN; TYP. SOFFIT LIGHTING LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" ADACABAA T.O.P. 182' -6" PENTHOUSE 192' -0"10/11/2021 ▪ 21415.0000BUILDING ELEVATIONS -SIGNAGE SOUTH FACADE - FACING DIVISION STREET WEST FACADE - FACING STATE STREET SIGNAGE ZONES INDICATED IN YELLOW. PRIMARY ZONES LOCATED AT TOP OF BUILDING, SECONDARY ZONES SHOWN AT PRECAST BAND SEPARATING LEVEL ONE AND TWO. SIGN NOTES: 1. KEY TENANT SIGNAGE PLACEMENT ZONES IDENTIFIED ON WESTERN AND SOUTHERN BUILDING FACADES. NO PRIMARY TENANT SIGNS ARE ENVISIONED TO OCCUR WITHIN THE NORTHERN AND EASTERN BUILDING FACADES. 2. BUILDING MOUNTED SIGNS WILL COMPLY WITH SOUTHLAKE SIGNAGE ORDINANCE NO. 704. 3. BUILDING SIGNS WILL BE A MAXIMUM OF 14" TALL AND WILL MATCH IN CHARACTER, FONT AND GENERAL APPEARANCE TO THE PHASE 1 BUILDING. 50'-0" 4'-0" 30'-0" 2'-0" SIGNAGE ZONES INDICATED IN YELLOW. PRIMARY ZONES LOCATED AT TOP OF BUILDING, SECONDARY ZONES SHOWN AT PRECAST BAND SEPARATING LEVEL ONE AND TWO. ARCHITECTURAL LIGHTING AT BASE OF COLUMN ALONG SOUTH FACADE; TYP. FIXTURE TYPE TO BE IN-GROUND 'LED' ASYMMETRICAL WALL-WASHER. CANOPIES / SUN SHADING DEVICES C-1 ALUMINUM COMPOSITE CANOPY MT-1 METAL PANEL CANOPY SYSTEM EXTERIOR BUILDING MATERIALS MP-1 METAL PANEL ACM-1 INSULATED ALUMINUM COMPOSITE METAL PANEL MS-1 METAL SCREEN WITH PERFORATED METAL PANEL C-1 ARCHITECTURALLY EXPOSED CONCRETE PC-1 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 1 PC-2 INSULATED PRE-CAST CONCRETE WITH INTEGRAL COLOR PC-3 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 2 PC-4 PRE-CAST CONCRETE WITH INLAID BRICK PC-5 PRE-CAST CONCRETE; PAINTED TO MATCH EXISTING CW ALUMINUM CURTAIN WALL SYSTEM WW ALUMINUM WINDOW WALL GL-1 INSULATED VISION GLASS GL-2 INSULATED SPANDREL GLASS GL-3 INSULATED VISION GLASS MATERIALS LEGEND LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" ADACABAA T.O.P. 182' -6" PENTHOUSE 192' -0" 03 A06-01 04 A06-01 05 A06-01 GL-2 CWGL-1PC-3WW 17' - 10" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 7' - 4" 10' - 0" GL-1PC-2 MP-1 92' - 0"9' - 6"82' - 6"PC-2 O P B2 B2 B2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 O1 O1 O1 O2 O2 O2 O1 O1 O1 QN2N2N2N2P1 Q2 Q2 Q24'-0"50'-0"2'-6"30'-0" SIGNAGE ZONES INDICATED IN YELLOW. PRIMARY ZONES LOCATED AT TOP OF BUILDING, SECONDARY ZONES SHOWN AT PRECAST BAND SEPARATING LEVEL ONE AND TWO. 11 10 9 8 7 J2 J2 J1 J1 J1 J2 J1 J2 J1 J2 J1 J1J2J1J2 J2J1 J1 J2J1 J1 K C1 C C C D HL4'-0"50'-0"2'-6"30'-0" LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" 123456 T.O.P. 182' -6" PENTHOUSE 192' -0" 6.1 CW MP-1 C-1 PC-1 CW GL-2GL-1 PC-3 4' - 6" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 17' - 4" GL-2 PC-2GL-1 28' - 0"64' - 0"92' - 0"PC-2GL-3 A B3 B B B DF J2 J2 J2 J1 J1 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 G J2 10 50'-0"4'-0"2'-6"30'-0" DATE JOB SHEET ISSUES KEYPLAN REVISIONS 9/12/2022 2:46:37 PMSOUTHLAKE OFFICE 209/12/22 21415.0000 09/12/2022 SIGNUnnamed601 STATE STREET, SOUTHLAKE, TX 76092CORGAN 401 N. Houston St Dallas, TX 75202 T: 214-748-2000 2 02/18/2022 50% CONSTRUCTION DOCS 1 10/25/2021 DESIGN DEVELOPMENT 3 03/11/2022 ISSUE FOR PERMIT 4 5/2/2022 ISSUE FOR CONSTRUCTION 5 6 7 8 9 10 P O 3/32" = 1'-0"02 WEST ELEVATION (Signage) SIGN NOTES: 1. KEY TENANT SIGNAGE PLACEMENT ZONES IDENTIFIED ON WESTERN AND SOUTHERN BUILDING FACADES, NO PRIMARY TENANT SIGNS ARE ENVISIONED TO OCCUR WITHIN THE NORTHERN AND EASTERN BUILDING FACADES. 2. BUILDING MOUNTED SIGNS WILL COMPLY WITH SOUTHLAKE SIGNAGE ORDINANCE NO. 704. 3. BUILDING IDENTIFICATION SIGNS WILL BE A MAXIMUM OF 14" TALL AND WILL MATCH IN CHARACTER. FONT AND GENERAL APPEARANCE TO THE PHASE 1 OF THE BUILDING. 3/32" = 1'-0"01 SOUTH ELEVATION - FACING DIVISION STREET CANOPIES / SUN SHADING DEVICES C-1 ALUMINUM COMPOSITE CANOPY MT-1 METAL PANEL CANOPY SYSTEM EXTERIOR BUILDING MATERIALS MP-1 METAL PANEL ACM-1 INSULATED ALUMINUM COMPOSITE METAL PANEL MS-1 METAL SCREEN WITH PERFORATED METAL PANEL C-1 ARCHITECTURALLY EXPOSED CONCRETE PC-1 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 1 PC-2 INSULATED PRE-CAST CONCRETE WITH INTEGRAL COLOR PC-3 INSULATED PRE-CAST CONCRETE WITH INLAID BRICK 2 PC-4 PRE-CAST CONCRETE WITH INLAID BRICK PC-5 PRE-CAST CONCRETE; PAINTED TO MATCH EXISTING CW ALUMINUM CURTAIN WALL SYSTEM WW ALUMINUM WINDOW WALL GL-1 INSULATED VISION GLASS GL-2 INSULATED SPANDREL GLASS GL-3 INSULATED VISION GLASS MATERIALS LEGEND LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" ADACABAA T.O.P. 182' -6" PENTHOUSE 192' -0" 03 A06-01 04 A06-01 05 A06-01 GL-2 CWGL-1PC-3WW 17' - 10" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 7' - 4" 10' - 0" GL-1PC-2 MP-1 92' - 0"9' - 6"82' - 6"PC-2 O P B2 B2 B2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2 O1 O1 O1 O2 O2 O2 O1 O1 O1 QN2N2N2N2P1 Q2 Q2 Q24'-0"50'-0"2'-6"30'-0" SIGNAGE ZONES INDICATED IN YELLOW. PRIMARY ZONES LOCATED AT TOP OF BUILDING, SECONDARY ZONES SHOWN AT PRECAST BAND SEPARATING LEVEL ONE AND TWO. 11 10 9 8 7 J2 J2 J1 J1 J1 J2 J1 J2 J1 J2 J1 J1J2J1J2 J2J1 J1 J2J1 J1 K C1 C C C D HL4'-0"50'-0"2'-6"30'-0" LEVEL 1 100' -0" LEVEL 2 122' -0" LEVEL 3 136' -0" LEVEL 4 150' -0" LEVEL 5 164' -0" ROOF 178' -0" 123456 T.O.P. 182' -6" PENTHOUSE 192' -0" 6.1 CW MP-1 C-1 PC-1 CW GL-2GL-1 PC-3 4' - 6" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 9' - 4" 0' - 8" 4' - 0" 0' - 8" 17' - 4" GL-2 PC-2GL-1 28' - 0"64' - 0"92' - 0"PC-2GL-3 A B3 B B B DF J2 J2 J2 J1 J1 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 J1 J1 J1 J2 J2 J2 G J2 10 50'-0"4'-0"2'-6"30'-0" DATE JOB SHEET ISSUES KEYPLAN REVISIONS 9/12/2022 2:46:37 PMSOUTHLAKE OFFICE 209/12/22 21415.0000 09/12/2022 SIGNUnnamed601 STATE STREET, SOUTHLAKE, TX 76092CORGAN 401 N. Houston St Dallas, TX 75202 T: 214-748-2000 2 02/18/2022 50% CONSTRUCTION DOCS 1 10/25/2021 DESIGN DEVELOPMENT 3 03/11/2022 ISSUE FOR PERMIT 4 5/2/2022 ISSUE FOR CONSTRUCTION 5 6 7 8 9 10 P O 3/32" = 1'-0"02 WEST ELEVATION (Signage) SIGN NOTES: 1. KEY TENANT SIGNAGE PLACEMENT ZONES IDENTIFIED ON WESTERN AND SOUTHERN BUILDING FACADES, NO PRIMARY TENANT SIGNS ARE ENVISIONED TO OCCUR WITHIN THE NORTHERN AND EASTERN BUILDING FACADES. 2. BUILDING MOUNTED SIGNS WILL COMPLY WITH SOUTHLAKE SIGNAGE ORDINANCE NO. 704. 3. BUILDING IDENTIFICATION SIGNS WILL BE A MAXIMUM OF 14" TALL AND WILL MATCH IN CHARACTER. FONT AND GENERAL APPEARANCE TO THE PHASE 1 OF THE BUILDING. 3/32" = 1'-0"01 SOUTH ELEVATION - FACING DIVISION STREET 299' B-B 327' B-B 419' B-B120'-0" 480'-0"VISIBILITY TRIANGLE 480'-0"VISIBILITY TRIANGLE 120'-0" 480'-0"VISIBILITY TRIANGLE 120'-0"F V SIGN SIGN SIGN A01-12 01 A01-12 06 Sim 5 STORY OFFICE BUILDING BUILDING HEIGHT: 80' TOTAL AREA: +/- 151,077 GSF FF: 638.35 ASL = 100'-0" L1 FFE EXISTING OFFICE BUILDING D I V I SI ON S TRE E TSTATE ST REETTRANSFORMER; REF. ELECT.KNOX BOX FDC DUMPSTER ENCLOSURE EXISTING PARKING 5 LEVEL GARAGE FIRE PUMP ROOM FIRE COMMAND CENTER NEW PARKING ADDITION 5 LEVEL GARAGE KNOX BOX KNOX BOX GENERATOR 8" BURNISHED BLOCK SCREENWALL (7'-4" TALL) FULLY GROUTED CELLS RESERVE STREETKNOX BOX DATE JOB SHEET ISSUES KEYPLAN REVISIONS 9/12/2022 2:51:17 PMA01-01 SITE PLAN SOUTHLAKE OFFICE 202/18/22 21415.0000 09/12/2022 A01-01SITE PLAN601 STATE STREET, SOUTHLAKE, TX 76092CORGAN 401 N. Houston St Dallas, TX 75202 T: 214-748-2000 2 02/18/2022 50% CONSTRUCTION DOCS 1 10/25/2021 DESIGN DEVELOPMENT 3 03/11/2022 ISSUE FOR PERMIT 4 5/2/2022 ISSUE FOR CONSTRUCTION 5 6 7 8 9 10 P O GARAGE ADDITION PARKING COUNT Level Count GARAGE LEVEL 1 45 GARAGE LEVEL 2 53 GARAGE LEVEL 3 53 GARAGE LEVEL 4 53 GARAGE LEVEL 5 53 PARKING TOTAL: 257 1" = 30'-0"1 SITE PLAN PLAN NN SITE TOTAL AREA: BUILDING AREA: FAR: PARKING EXPANSION: BIKE STORAGE: LOADING SPACES: +/- 2.3 ACRES +/- 151,000 GSF 1.5 257 SPACES 15 SPACES 1 SITE METRICS 1 1 5/9/2022 CITY COMMENT RESPONSES