Item 7 - PresentationSite Plan for Bicentennial Park Pickleball Court
ZA22-0023
ZA22-0023
APPLICANT:Parkhill |Schrickel Rollins
OWNER:City of Southlake
REQUEST: Approval of a Site Plan for the Bicentennial Park Pickleball Court.
LOCATION: 450 W. Southlake Blvd.
Aerial View
Proposed Site Plan
Proposed Site Plan
Championship
Court
Office/Restroom
Building
Proposed Landscape Plan
Building Floor Plan
Building Elevations
South Wall Elevation
South wall subject to articulation requirements due to length and visibility from Southlake Blvd.
Note that some articulation is provided with pilasters.
Photometric Study Findings & Variances
Average
footcandle
reading exceeds
the permitted 30
footcandle
average.
5700K LED when
maximum
temperature
permitted is
4300K.
Photometric Calculations
Photometric Calculations
Area of
most
intense
lighting.
Summary of Variances
Variance to southern façade articulation under Zoning Ordinance No.480,Section 43.19.d.1.c:“Horizontal and Vertical Articulation:No wall shall extend for a distance greater than three (3)times the height of the
wall without changing height by a minimum of 15%of the wall’s height,and such change shall continue for a minimum
distance equal to at least 25%of the maximum length of either adjacent plane.”The two offsets provided do not meet
the minimum depth or width.
Variance to Lighting Ordinance No.693-C,Section 5(b):“The maximum outdoor computed or
measured illumination level on a property shall not exceed 20 foot candles outdoors at any point,except that lighting
under canopies (such as service stations)shall not exceed 30 foot candles.”The proposed average intensity is
approximately 50 footcandles,however the proposed lighting generally conforms to standard athletic field lighting
throughout Bicentennial Park.Furthermore,lighting spillage to non-commercial sites is unmeasurable,as the nearest
residential home is approximately 1,000 feet from the proposed site.
Variance to Lighting Ordinance No. 693-C, Section 4(b): “Luminaires on poles over 42 inches in height
and exterior wall mounted light fixtures shall be either high pressured sodium lights or neutral or warm correlated color
temperature Light Emitting Diode (LED) lights (temperature equal to or less than 4300 degrees Kelvin) or other lights
giving a similar soft lighting effect.”The proposed lighting type is LED and is 5700 degrees kelvin.
Site Photographs
Surrounding Property Owner Responses
For:
Opposed:
Undecided:
Questions?